Telephone : Telefax : E-mail : Internet : LFE GmbH & Co.KG Process Analytical Instrumentation Am Germanenring 54 D-63486 Bruchköbel / Germany +49 - (0)6181 - 49 53 02 +49 - (0)6181 - 49 38 07 [email protected] www.lfe.de CONTHOS 3-PMD Paramagnetic Process Gas Analyzer Application Questionnaire The following questionnaire can help to define the analysis boundary conditions for the implementation of an LFE CONTHOS for oxygen analysis. Contact details Company: E-mail: Name: Phone: Dept.: Fax: Address: Type of sample gas / application Biogas Metallurgy Chemical other: Gas production Synthesis gas Petrochemical Installation site Installation site Indoor Ambient temperature at location Hazardous area min.: Outdoor °C norm.: Ex zone 1 °C max.: Ex zone 2 °C Ex free Gas composition and characteristics Please list all relevant gases. Please be sure to list O2 or air if it can also be present in the sample gas during measuring operation. Component min. (vol.%) normal (vol.%) max. (vol.%) Analyzer range if measured component ( for potential use in dynamic interference correction) 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Corrosive or toxic components (e.g. SO3, HF, Cl2, HCl, H2S, NH3 or HCN, COCl2) min Sample gas dew point max units °C Sample gas pressure Sample gas temperature LFE GmbH & Co.KG °C CONTHOS 3-PMD Application Questionnaire 81916611 31.07.17 Page 2 of 3 CONTHOS analyzer version CONTHOS 3E PMD CONTHOS 3F PMD Housing version Sample gas connectors 19” rack housing Field housing for tubing 6mm for tubing 6mm for tubing ¼" for tubing ¼" NPT-¼" female for tubing 6mm Housing purge connectors for tubing ¼" Power supply Standard: 100-240VAC, 50-60Hz Desired CONTHOS analyzer range(s) Begin of range Units (vol.% or ppm) End of range Range 1 to O2 Range 2 to O2 Range 3 to O2 lowest range: 0 - 1% O2 largest range: 0 - 100% O2 Interface options Digital I/O expansion 8 optically isolated digital inputs 7 floating relay contacts Serial interface RS485 with Modbus RTU Note: The digital I/O module cannot be used in conjunction with the optional serial interface module. Comments LFE GmbH & Co.KG CONTHOS 3-PMD Application Questionnaire 81916611 31.07.17 Page 3 of 3 Technical prerequisites This questionnaire assumes as a prerequisite that the sample gas and conditions presented to the CONTHOS fulfill the following: The customer must ensure that the sample gas is dry and free of particulates and aggressive components before entering the analyzer. That means an adequate sample handling system is in place. The sample gas dew point should at minimum be 10°C below ambient temperature to avoid condensation in the gas lines. The sample flow rate is between 30 - 60 l/h for optimum performance (min. 3 l/h, max. 120 l/h). The sample gas pressure does not exceed max. 300 mbar over atmospheric pressure. The CONTHOS should not be used for measuring ignitable gas mixtures. The customer must ensure compliance with applicable regulations when using the analyzer with flammable or toxic gases or when installing within hazardous areas. Measuring principle - gas composition The CONTHOS 3-PMD uses a paramagnetic sensor. This measuring principle is highly selective for oxygen analysis. Nonetheless it is necessary to provide as much of the following information as possible in order to calculate potential interferences presented by the different constituents. LFE GmbH & Co.KG CONTHOS 3-PMD Application Questionnaire 81916611 31.07.17
© Copyright 2026 Paperzz