Canadian

SECTION 28 13 00
ACCESS CONTROLS
Display hidden notes to specifier. (Don't know how? Click Here)
Copyright 2007 - 2017 ARCAT, Inc. - All rights reserved
PART 1 GENERAL
1.1
1.2
1.3
SECTION INCLUDES
A.
Access Control Systems:
1.
Single entry access keypad and proximity reader (LiftMaster Model KPR2000).
2.
Wireless access control keypad (LiftMaster Models KPW5, KPW250).
3.
Stand-alone keypad access control system (LiftMaster Model MINIkey).
4.
Commercial universal receiver with antenna (LiftMaster Model STAR1000).
5.
Wireless single push-button control station (LiftMaster Model WPB1LM3).
6.
Wireless 3-button control station (LiftMaster Model WPB3LM3).
7.
Passport stand-alone proximity card reader (LiftMaster Model PPLX).
8.
Passport receiver and remote access control (LiftMaster Model PPWR).
B.
Telephone Entry Control Systems:
1.
Single tenant telephone entry systems (LiftMaster Model EL1SS).
2.
Office building or gated residential community telephone entry systems (LiftMaster
Model CAPXL Connected Access Portal - High Capacity).
3.
Residential and light commercial telephone entry control system (LiftMaster Model
EL25).
4.
Commercial and gated community telephone entry system (LiftMaster Model EL2000).
C.
Parking Control Systems:
1.
High-performance, DC-powered barrier gate operator and accessories (LiftMaster
Models MADCBB, MATDCBB).
2.
High-speed, DC-powered barrier gate operator and accessories (LiftMaster Models
MASDCBB, MASTDCBB).
RELATED SECTIONS
A.
Section 03 30 00 - Cast-in-Place Concrete.
B.
Section 26 05 00 - Common Work Results for Electrical.
C.
Section 27 32 00 - Voice Communications Terminal Equipment.
D.
Division 16 - Requirements for electrical connections.
REFERENCES
A.
Underwriters Laboratories (UL):
1.
UL 325 - Standard for Safety for Door, Drapery, Gate, Louver, and Window Operators
and Systems.
2.
UL 991 - Standard for Tests for Safety-Related Controls Employing Solid-State
Devices.
B.
NFPA 70 - National Electrical Code.
28 13 00-1
1.4
1.5
1.6
C.
FCC Regulations.
D.
Canadian Department of Communications.
SUBMITTALS
A.
Submit under provisions of Section 01 30 00 - Administrative Requirements.
B.
Submittals:
1.
Manufacturer's Data: Submit copies of the following:
a.
Product data sheets and system description.
b.
Installation instructions.
c.
Authorized dealer certificate and certified training certificates of installers who
will be working on this project.
d.
Block diagrams.
e.
Equipment list.
2.
Shop Drawings: Submit the following:
a.
Access system layout and locations, including size requirements.
b.
Detailed wiring diagrams of access equipment.
c.
Load calculations of all equipment for proper sizing of electrical provided by the
customer and standby emergency generator circuits.
3.
As-Built Drawings: Update shop drawings to create final as-built drawings. Submit 3
copies and digitally in AutoCAD 14 or later format on a CD (3 copies).
4.
Operation Data: Include 3 copies of the software administrator and operator manuals.
5.
Maintenance Data: Include maintenance and repair procedures.
C.
Submittals:
1.
Product Data: Equipment list, system description, electrical wiring diagrams for
installation, and manufacturer's data sheets on each product to be used, including:
a.
Preparation instructions and recommendations.
b.
Storage and handling requirements and recommendations.
c.
Installation methods.
2.
Shop Drawings: Submit shop drawings showing layout, profiles, and product
components, including anchorage, edge conditions, and accessories.
a.
Operation, installation, and maintenance manuals including wiring diagrams.
b.
Risers, layouts, and special wiring diagrams showing any changes to standard
drawings.
DELIVERY, STORAGE, AND HANDLING
A.
Store products in manufacturer's unopened packaging with labels intact until ready for
installation.
B.
Schedule delivery of parking control equipment so that spaces are sufficiently complete that
operators can be installed upon delivery.
C.
Owner will provide, on-site, a secure, dry, locked storage area for all equipment delivered
under this scope of work.
QUALITY ASSURANCE
A.
Quality Assurance:
1.
Manufacturer: The access control system shall be from a single-source manufacturer
that specializes in telephone entry control systems with a minimum of 5 years of
experience.
2.
Installer: Company specializing in access control systems with a minimum of 3 years
of experience on systems of similar size and scope. Technicians working on project
28 13 00-2
must have been certified on the hardware and software used for this project.
B.
1.7
PROJECT CONDITIONS
A.
1.8
Assurance:
1.
Perform installation by factory authorized contractor specifically trained in gate
operation systems of the type found within this section.
2.
Provide documentation of maintenance and repair service availability for emergency
conditions.
3.
Provide quarterly maintenance for 1 year following substantial completion of the
project.
Maintain environmental conditions (temperature, humidity, and ventilation) within limits
recommended by manufacturer for optimum results. Do not install products under
environmental conditions outside manufacturer's absolute limits.
WARRANTY
A.
Manufacturer's Standard Warranty:
1.
Access Control System Warranty: 1 year limited warranty.
2.
Telephone Entry System Warranty: 1 year limited warranty.
3.
Telephone Entry/Access and Perimeter Control System: 2 years limited warranty.
PART 2 PRODUCTS
2.1
2.2
MANUFACTURERS
A.
Acceptable Manufacturer: LiftMaster, which is located at: 300 Windsor Dr.; Oak Brook, IL
60523; Toll Free Tel: 800-282-6225; Fax: 630-516-8412; Email:request info
([email protected]); Web:LiftMaster.com
B.
Substitutions: Not permitted.
C.
Requests for substitutions will be considered in accordance with provisions of Section 01 60
00 - Product Requirements.
ACCESS CONTROL SYSTEMS
A.
Single Entry Access Keypad and Proximity Reader: LiftMaster KPR2000 Single Entry
Access Control Keypad and Proximity Reader.
1.
Performance:
a.
Operating Voltage: 12V to 24V DC.
b.
Current Draw: 25 mA idle; 60 mA peak.
c.
Proximity Card Reader: HID 26-bit and 30-bit Wiegand format.
d.
Industry standard 125 kHz.
e.
Read Range - Proximity: 1 to 2-1/2 inches (25 mm to 64 mm).
f.
Weatherization: Meets or exceeds IP68.
g.
Operating Temperature: -4 degrees F (-20 degrees C) to 140 degrees F (60
degrees C).
h.
Operating Humidity: 10% to 90% non-condensing.
2.
Construction: Zinc-alloy enclosure.
3.
Dimensions: Surface mount, 5 inches H x 3-1/5 inches W x 1-1/10 inches D (127 mm
H x 81 mm W x 28 mm D).
4.
Standard Features:
a.
Stand-alone controller and pass-through mode.
b.
Selectable ASCII keypad mode, or 26-bit card keypad mode.
c.
Controls access for up to 2,000 users (card only, card or PIN, card and PIN).
28 13 00-3
5.
d.
Integrated alarm buzzer.
e.
Additional alarm output (20A).
f.
Rugged vandal-resistant backlit metal enclosure.
g.
One programmable relay output (2A, form A).
h.
Timed or latch mode to hold door/gate open (1 to 99 second timer).
i.
Supports second keypad configuration for in and out same door or gate.
j.
Block enrollment capability.
k.
Program cards included for rapid programming.
l.
Anti-tamper alarm (1 to 3 minute timer).
Accessories:
a.
Low-Profile Access Pedestal (LiftMaster Model PED42).
b.
High-Profile Access Pedestal (LiftMaster Model PED64).
c.
12V DC, 2A Power Supply (LiftMaster Model PS12D2A).
d.
HID 26-Bit Proximity Card, or Key Fob.
e.
HID 30-Bit Proximity Card, facility code 2 (LiftMaster Model SNACPH32).
f.
HID 30-Bit Proximity Card, facility code 9 (LiftMaster Model SNACPH39).
g.
HID 30-Bit Proximity Key, facility code 2 (LiftMaster Model SNACPKH32).
h.
HID 30-Bit Proximity Key, facility code 9 (LiftMaster Model SNACPKH39).
B.
Wireless Keypad Controls: LiftMaster KPW5 Wireless Access Control Keypad.
1.
Standard Features:
a.
Up to 5 access codes and 10 unique temporary PINs that can be set for 1 to 9
uses
b.
Designed to work exclusively with Security+ 2.0.
c.
Combines the simplicity of wireless installation with the robust feature sets of
higher-priced keypad controllers.
d.
High-impact polycarbonate front cover for rugged outdoor environment.
e.
Electronics are fully sealed and meet NEMA 4X water protection requirements.
f.
Allows for removal of a single PIN while maintaining full access for other users.
g.
Up to 500-foot (152 m) range (open field).
h.
Blue Backlit metal keypad for ease of use under low-light conditions.
2.
Dimensions: Surface mount, 6 inches H x 4-3/10 inches W x 1-3/4 inches D (153 mm
H x 109 mm W x 45 mm D).
3.
Power: 9V Lithium battery.
4.
Enclosure: Surface-mount, vandal-resistant plastic and weather-resistant enclosure.
C.
Wireless Commercial Keypad: LiftMaster KPW250 Wireless Access Control Keypad.
1.
Standard Features:
a.
Up to 250 access codes and 10 unique temporary PINs, that can be set for 1 to
9 uses..
b.
Compatible with Security+ 2.0 and Security+, as well as Linear Multi-Code 300
MHz,
c.
Combines the simplicity of wireless installation with the robust feature sets of
higher-priced keypad controllers.
d.
Zinc-alloy metal front cover for tough environments,
e.
Electronics are fully sealed and meet NEMA 4X water protection requirements.
f.
Allows for removal of a single PIN while maintaining full access for other users.
g.
Up to 500-foot (152 m) range (open field).
h.
Blue backlit metal keypad for ease of use under low-light conditions.
i.
Keypad lighted when motion is detected.
2.
Dimensions: Surface mount, 6 inches H x 4-3/10 inches W x 1-3/4 inches D (153 mm
H x 109 mm W x 45 mm D).
3.
Power: 9V Lithium batteries.
4.
Enclosure: Surface-mount, vandal-resistant plastic and weather-resistant enclosure.
D.
Stand-Alone Keypad Access Control System: LiftMaster MINIkey Self-Contained Keypad
28 13 00-4
System for Door and Gated Entrances.
1.
Standard Features:
a.
Control system shall be configured to allow either 4 or 5-digit codes activating
the primary and/or auxiliary relay of the remote keypad when scheduled or
required.
b.
Lighted keypad.
c.
Capacity: 500 names.
d.
Relay Hold: Codes can be configured to latch relays open until they are
unlatched by a second entry code to close.
e.
Programmable Relay Times: Each relay independently programmable to
activate from 2 to 255 seconds.
f.
Time Clock: Access can be denied by preset times on dealer-supplied time
clock.
g.
Variable Entry Code Length: 4 or 5 digits.
h.
Password Protection: Database information protected with 6-digit password.
i.
Non-Volatile Memory: In event of power failure, database information is
retained in memory allowing immediate start-up and operation when power is
restored.
j.
Strikes and Outs: Management specifies from 1 to 9 wrong entry codes entered
consecutively before the system stops accepting codes for a 3-minute period.
k.
Programming: Direct programming using built-in keypad.
l.
Lightning Protection: Installer shall provide external surge suppressors in
addition to surge protection inherent in the entry system.
2.
Remote Keypad: For applications that require an entry and exit keypad, or for control
of a secondary entry point, provides remote keypad unit that connects directly to the
main unit.
3.
Dimensions:
a.
Surface Mount: 4-1/2 inches H x 4-1/2 inches W x 3-1/2 inches D (114 mm H x
114 mm W x 89 mm D).
b.
Flush Mount: 4-3/4 inches H x 4-3/4 inches W x 3 inches D (121 mm H x 121
mm W x 76 mm D).
4.
Power:
a.
12V AC.
b.
13.5V DC.
5.
Enclosure:
a.
Vandal-resistant housing with stainless steel faceplate and side-lit metal
keypad.
b.
Wall mount.
c.
Pedestal mount.
E.
Wireless Receiver for Gate and Commercial Door Operators: LiftMaster STAR1000
Commercial Access Control Receiver.
1.
Standard Features:
a.
Security+ 2.0 Technology provides 2x the radio range of standard remotes.
b.
Compatible with HomeLink wireless control system.
c.
1,000 remote capacity to support large quantity remote control requirements.
d.
Single and block addition.
e.
Supports suspending and unsuspending of remote controls to withhold and
reinstate access.
f.
Designed for outdoor environments.
g.
Duplicate memory module included that may be removed for programming
additional receivers or for safe storage.
h.
9-inch (229 mm) antenna included.
2.
Passport Remote Controls: Model and description (315 MHz).
a.
LiftMaster PPV1 Passport 1-Button Remote.
b.
LiftMaster PPV3 Passport 3-Button Remote.
28 13 00-5
3.
4.
5.
6.
7.
8.
9.
10.
c.
LiftMaster PPK1 Passport 1-Button Mini Remote.
d.
LiftMaster PPK3 Passport 3-Button Mini Remote.
e.
LiftMaster PPK1PH Passport 1-Button Mini Proximity Remote.
f.
LiftMaster PPK3PH Passport 3-Button Mini Proximity Remote.
g.
LiftMaster PPLV1 Passport Lite 1-Button Remote.
h.
LiftMaster PPLK1 Passport Lite 1-Button Mini Remote.
i.
LiftMaster PPLK1PH Passport Lite 1-Button Mini Proximity Remote.
Security+ 2.0 Remote Controls: Model and description.
a.
LiftMaster 811LM 1-Button Encrypted DIP Remote Control.
b.
LiftMaster 813LM 3-Button Encrypted DIP Remote Control.
c.
LiftMaster 890MAX 3-Button Mini Remote Control.
d.
LiftMaster 893MAX 3-Button Remote Control.
e.
LiftMaster 895MAX 3-Button Premium Remote Control.
f.
LiftMaster 877MAX Keyless Entry.
Dimensions: Surface mount, 6 inches H x 4-1/8 inches W x 1-7/8 inches D (152 mm H
x 105 mm W x 48 mm D).
Power: 9 to 30V AC and 9 to 34V DC.
Enclosure: Surface-mount, vandal-resistant plastic and weather-resistant enclosure.
Relay Output Type: One form A relay contact. Common and normally open contacts.
Operating Temperature: -40 degrees F (-40 degrees C) to 149 degrees F (65 degrees
C).
Operating Humidity: 10% to 90% non-condensing.
Storage Temperature: -40 degrees F (-40 degrees C) to 185 degrees F (85 degrees
C).
F.
Wireless Push-Button Controls: LiftMaster WPB1LM3 Wireless Single Push-Button Control
Station.
1.
Standard Features:
a.
Wireless control of a single gate.
b.
Up to 500-foot (152 m) range.
c.
Functions in the same manner as a single, or 3-button (LiftMaster Model
333LM) remote control.
d.
Use only with LiftMaster Logic 4.0 and medium-duty Logic commercial door
operators.
2.
Dimensions: Surface mount, 6-1/2 inches H x 4-5/16 inches W x 2-5/8 inches D (165
mm H x 110 mm W x 67 mm D).
3.
Power: Four AA 1.5V DC batteries.
4.
Enclosure: Surface-mount, vandal-resistant plastic and weather-resistant enclosure.
G.
Wireless Push-Button Controls: LiftMaster WPB3LM3 Wireless 3-Button Control Station.
1.
Standard Features:
a.
Wireless control of a single gate.
b.
Up to 500-foot (152 m) range.
c.
Functions in the same manner as a single, or 3-button (LiftMaster Model
333LM) remote control.
d.
Use only with LiftMaster Logic 4.0 and medium-duty Logic Commercial Door
Operators.
2.
Dimensions: Surface mount, 6-1/2 inches H x 4-5/16 inches W x 2-5/8 inches D (165
mm H x 110 mm W x 67 mm D).
3.
Power: Four AA 1.5V DC batteries.
4.
Enclosure: Surface-mount, vandal-resistant plastic and weather-resistant enclosure.
H.
Stand-Alone Proximity Access Control Device: LiftMaster PPLX Passport Stand-Alone
Proximity Card Reader.
1.
Dimensions: Surface mount, 4-1/2 inches H x 3-1/5 inches W (115 mm H x 82 mm
W).
28 13 00-6
2.
3.
4.
5.
6.
7.
I.
Power: 5 to 14V DC, 50 mA idle, 150 mA maximum.
Enclosure: Surface-mount, vandal-resistant plastic faceplate and single-gang
weatherproof outlet box.
Operating Temperature Environment Access Control Unit and Cards: Ambient temp. 40 degrees F (-40 degrees C) to 158 degrees F (70 degrees C).
Operating Humidity: 0 to 95% non-condensing.
System Components:
a.
Stand-Alone Proximity Reader (LiftMaster Model PPLX).
b.
Proximity Radio Programmer (LiftMaster Model PPRP).
c.
Power supply 12V DC 2.0A (LiftMaster Model PS12D2A).
d.
34-Bit Passport Proximity Card (clamshell) (shipped in sleeves of 50)
(LiftMaster Model PPCSC).
Standard Features:
a.
6-inch (152 mm) card reader range.
b.
Capacity: 50,000 users.
c.
Programmable Output Relay: (NO/NC). SPST solid-state relay, 1A max. at 60V
AC or DC.
d.
"Latch Mode" to hold a door or gate open.
e.
Timed anti-passback logic.
Commercial Receiver and Remote Access Control: LiftMaster PPWR Passport Credential
Radio Control Receiver.
1.
Receiver: LiftMaster PPWR Passport Receiver with Security+ 2.0.
2.
Standard Receiver Features:
a.
Security+ 2.0 Technology provides 2x the radio range of standard remotes.
b.
Compatible with HomeLink wireless control system.
c.
Supports standard 26-bit, 31-bit, 34-bit even and odd, 50-bit and Sentex 30-bit
proximity card formats.
d.
Designed for outdoor environments.
e.
Duplicate memory module included that may be removed for programming
additional receivers or for safe storage.
f.
12,000 remote capacity.
g.
9-inch (229 mm) antenna.
h.
Standard Wiegand output interface.
i.
Delete remote control not required.
3.
Passport Remote Controls: Model and description (315 MHz).
a.
LiftMaster PPV1 Passport 1-Button Remote.
b.
LiftMaster PPV3 Passport 3-Button Remote.
c.
LiftMaster PPK1 Passport 1-Button Mini Remote.
d.
LiftMaster PPK3 Passport 3-Button Mini Remote.
e.
LiftMaster PPK1PH Passport 1-Button Mini Proximity Remote.
f.
LiftMaster PPK3PH Passport 3-Button Mini Proximity Remote.
g.
LiftMaster PPLV1 Passport Lite 1-Button Remote.
h.
LiftMaster PPLK1 Passport Lite 1-Button Mini Remote.
i.
LiftMaster PPLK1PH Passport Lite 1-Button Mini Proximity Remote.
4.
Security+ 2.0 Remote Controls: Model and description.
a.
LiftMaster 811LM 1-Button Encrypted DIP Remote Control.
b.
LiftMaster 813LM 3-Button Encrypted DIP Remote Control.
c.
LiftMaster 890MAX 3-Button Mini Remote Control.
d.
LiftMaster 893MAX 3-Button Remote Control.
e.
LiftMaster 895MAX 3-Button Premium Remote Control.
f.
LiftMaster 877MAX Keyless Entry.
5.
Power: 12V to 24V DC.
6.
Enclosure: Surface-mount, vandal-resistant plastic and weather-resistant enclosure. 6
inches H x 4-1/8 inches W x 1-7/8 inches D (152 mm H x 105 mm W x 48 mm D).
7.
Operating Temperature: -40 degrees F (-40 degrees C) to 149 degrees F (65 degrees
28 13 00-7
8.
2.3
C).
Storage Temperature: -40 degrees F (-40 degrees C) to 185 degrees F (85 degrees
C).
TELEPHONE ENTRY CONTROL SYSTEMS
A.
Single Tenant Entry Telephone Access Control Systems:
1.
Acceptable Product: LiftMaster EL1SS Single Line Telephone Intercom Access
Control System; access control for 2 entry points.
2.
Enclosure:
a.
Vandal-resistant stainless steel housing and brushed stainless steel faceplate.
6-1/4 inches H x 10 inches W x 5-1/4 inches D (160 mm H x 254 mm W x 133
mm D).
3.
Performance:
a.
Power: UL listed AC/DC adapter,115V AC Input, 16V DC, 2.5A, 40W output
transformer included.
b.
Operating Temperature: -4 Degrees F (-20 degrees C) to 149 degrees F (65
degrees C).
c.
Diagnostic and status LEDs.
d.
On-board surge suppression.
e.
Bypass board included (ability to disconnect EL1SS and maintain house phone
if required).
f.
Telephone Ringer Equivalence Number (REN): 0.5B.
4.
Standard Features:
a.
Full Duplex Communications: Clear audio with echo suppression technology.
Prevents cross-talk between speaker and microphone, by allowing the higher
energy signal through.
b.
Memory Chip Capacity: (200) 4-digit codes. Each resident assigned 4-digit
entry code. One temporary entry code that expires upon use, or 24 hours.
c.
Backlit keypad and call button.
d.
Call Forwarding Dialing: Entry system supports up to 14-digit dialing.
e.
Caller ID message from call button, or when tampered with.
f.
Party Mode activates relay until cancelled.
g.
Vacation Mode locks out all but the master PIN number.
h.
Two independent 10A, form C relays, with NC/NO outputs. One relay to control
door, gate or auxiliary device; remaining relay used to control auxiliary devices
or to shunt alarm contacts, or to signal alarm condition on main relay. Activation
time between 0.5 and 8,000 seconds.
i.
Intercom Mode: Allows the unit to operate a telephone, without the need for
having a telephone line connected from a central office.
j.
Auto-call input allows a simple external contact closure to act as a call button.
k.
Auto Sensor Input: May be set to automatically dial the residence when a
vehicle approaches the property.
l.
Non-Volatile Memory: In event of power failure, database information is
retained in memory allowing immediate start-up and operation when power is
restored.
m.
Lightning Protection: Installer shall provide external surge suppressors in
addition to surge protection inherent in the entry system.
B.
Commercial and Gated Community Telephone Entry System:
1.
Acceptable Product: LiftMaster CAPXL - Connected Access Portal High Capacity.
2.
Local User Capacity: 50,000
3.
Standard Features:
a.
Programming: LiftMasterCloud.com allows control and programming through an
IP internet connection.
b.
User interface: 10" color touch display with customizable background. Search
28 13 00-8
for resident name by scrolling or using on screen QWERTY keypad.
Controllable System Relays: 4 independent relays and 4 auxiliary relays can be
set to activate doors/gates; can function as strike, control, shunt, alarm or
CCTV relays. Activation time between 1 and 300 seconds.
d.
Call Forwarding: System will dial a pre-programmed telephone number when
the tenant is not at the monitored location. Access can be granted or denied
from remote location. Call forwarding can be programmed manually as needed
or time-activated to occur at scheduled intervals.
e.
Call Waiting: Resident can answer an access call from a visitor while in the
middle of another outside call. Resident can answer an outside call if on an
access call.
f.
Automatic Gate/Door Unlock Schedule: Main or auxiliary access points can be
programmed to open at pre-defined times.
g.
Holiday Programming: Unique holiday schedules can be defined to override the
pre-defined lock/unlock schedules.
h.
Quick call input: Loop detector input initiates a call to a predefined phone
number
i.
Do Not Disturb: Assignable on tenant-by-tenant basis when programmed
manually through touch-tone telephone or by a pre-programmed schedule.
j.
Wiegand output: Pass approved credential data and guest granted data to
secondary access control system.
Unit Operating Temperature Range: 20 degrees F (-6 degrees C) to 130 degrees F
(54 degrees C). Ambient capability -20 degrees F (-29 degrees C) to 130 degrees F
(54 degrees C).
Supply Voltage:
a.
24V DC, 4A (transformer input 120V AC, 60 Hz, 5.0A).
Operating Current:
a.
4.0 A MAX (without accessories).
b.
Surge Suppression-EFT: 2 Kv power line; ESD: 15 Kb Hbm/8 Kv
direct/200VMm (compliance with UL).
Enclosure Dimensions: 18 inches H x 14 inches W by 4.5 inches D (457 mm H x 356
mm W x 114 mm D).
Enclosure Material:
a.
Front Panel: 16 gauge 316 ASTM A480 steel alloy.
b.
Enclosure: -16-gauge 304 steel alloy.
Enclosure Finish:
a.
Front Panel: Brushed stainless steel (standard).
b.
Enclosure: Light gray powder coat (standard).
System Components:
a.
LiftMaster CAP2D - Connected Access Portal - 2 Door.
b.
LiftMaster Cloud based Elevator Integration.
1)
CAPB485.
2)
CAPDC485.
3)
CAPRELAY.
c.
LiftMaster Cellular modem - CAPCELL.
d.
LiftMaster Back box and trim kit - CAPXLTK.
1)
Trim Ring: Brushed stainless steel (standard).
e.
LiftMaster LMMC-MINI HID MultiClass SE RP10 Mini Mullion reader.
f.
LiftMaster external weigand keypad - KPR2000.
g.
LiftMaster radio antenna extension kit - 86LM.
h.
LiftMaster Wifi antenna extension kit - WFAEXT.
i.
LiftMaster Quick Call input loop kit - LPEXP.
j.
LiftMaster Passport 1 Button Credentialed Transmitters.
1)
Passport Lite 1 button visor Transmitter PPLV1.
2)
Passport Lite 1 button keychain Transmitter PPKL1.
3)
Passport Lite 1 button keychain with RFID coil PPKL1PH.
c.
4.
5.
6.
7.
8.
9.
10.
28 13 00-9
k.
11.
12.
C.
LiftMaster Passport Max 3 button Credentialed Transmitters.
1)
Passport MAX 3 button visor Transmitter PPV3M.
2)
Passport MAX 3 button keychain Transmitter PPK3M.
3)
Passport MAX 3 button keychain with RFID coil PPK3PHM.
Requirements:
a.
Active SIP service (Session Initiation Protocol).
b.
Active LiftMaster Cloud subscription - offered through LiftMaster.
c.
Connection:
1)
High-speed CAT 5/6 Internet connection (10/100 mbps). Up to 325 feet
(100 m) without additional networking hardware
2)
Wifi IEEE 802.1b, 802.11b/g, and 802.11 b/g/n (200 ft maximum range).
3)
Mount: LiftMaster PED42 Pedestal; 42 inches (1067 mm) pad mount, 2
inches H x 2 inches W (51 mm H x 51 mm W) square black powdercoated pedestal.
Mount: LiftMaster PED64 Pedestal; 64 inches (1626 mm) in-ground mount, 2 inches H
x 2 inches W (51 mm H x 51 mm W) square black powder-coated pedestal.
Residential and Light Commercial Telephone Entry Control System:
1.
Acceptable Product: LiftMaster EL25 Residential and Commercial Telephone Entry
System with expanded capacity and enhanced versatility.
2.
Base Unit Includes E-Z Scan Plug-in Modules:
a.
Wiegand Input Module: Allows addition of card readers, remote keypads and
Passport receiver.
b.
RF Module: Allows access through gates/doors with standard rolling code
transmitters (915 MHz).
3.
Memory Chip Capacity: 2,000 users; programmable as directory codes, access codes
and cards.
4.
Standard Features:
a.
Remote Access Diagnostics: Unit will record the following alarms: Forced
door/gate, door/gate ajar, unit over/under voltage.
b.
Voice Prompts: Push-button provides ADA-compliant voice prompts for end
users.
c.
Line Noise Tolerance: Enhanced telephone connection to unit via modem.
d.
Legacy Database Conversion: Versa XS 4.0 software allows transfer of
information from existing Sentex system to new Sentex system.
e.
Programming: Versa XS 4.0 software allows control programming through
modem, unit keypad or direct laptop connection.
f.
Controllable System Relays: 4 independent relays can be set to activate
doors/gates; can function as strike, control, shunt, alarm or CCTV relays.
Activation time between 1 and 300 seconds.
g.
Call Forwarding: System will dial a pre-programmed telephone number when
the tenant is not at the monitored location. Access can be granted or denied
from remote location. Call forwarding can be programmed manually as needed
or time-activated to occur at scheduled intervals.
h.
Call Waiting: Resident can answer an access call from a visitor while in the
middle of another outside call. Resident can answer an outside call if on an
access call.
i.
Illuminated keypad.
j.
Non-Volatile Memory: In event of power failure, database information is
retained in memory allowing immediate start-up and operation when power
k.
is restored.
l.
Separate Call Button: Initiates phone call to resident.
m.
Distinctive Ringing: Unique double ring on resident's telephone to distinguish
between a standard call and an access request call.
n.
Entry Codes: Codes can be time-restricted or established as one-time-use only.
o.
Holiday Programming: Maximum of 16 holidays can be defined to override the
28 13 00-10
pre-defined lock/unlock schedules.
Time Zones: Software manages up to 62 separate time zones with 3 segments
each for access/no access schedules.
q.
Anti-Passback: Waits for pre-programmed period of time before code or card
can be reused.
r.
Transaction Monitoring: Maximum of 4,000 transactions (date, time, unit ID and
transaction) stored in unit are retrievable for record of on-site activities.
s.
Battery backed clock/calendar including daylight savings and leap years.
t.
Automatic Gate/Door Unlock Schedule: Main or auxiliary access points can be
programmed to open at pre-defined times.
u.
Security Lockout: Locks out all users for a programmable period of time if
several invalid code attempts are made.
v.
Alarm Calling: System dials pre-defined telephone number to notify security
personnel of the alarm condition if door/gate is forced open or held open too
long.
w.
Remote Updates: Software updates accomplished through remote computer
and modem connection.
x.
Do Not Disturb: Assignable on tenant-by-tenant basis when programmed
manually through touch-tone telephone or by a pre-programmed schedule.
y.
Lightning Protection: Installer shall provide external surge suppressors in
addition to surge protection inherent in the entry system.
z.
Auto Sensor Input: Programmable to automatically dial the residence when a
vehicle approaches the property.
Exit Reader: Provides reader for true anti-passback operation.
Camera: Integrates camera into system to provide live video directly to television or
monitor screen.
a.
Color low-lux camera compatible with DVRs.
Passport Control: Push-button remote control will operate LiftMaster Garage Door
Operators, Gate Operators and Commercial Door Operators. Requires Passport
receiver.
E-Z Scan: Cards and Passport transmitters can be programmed into the unit through
the card reader or radio receiver installed into one of the plug-in modules.
Lighted directory enclosure for paper insert with 125 names.
Dimensions for LiftMaster EL25 Surface Mount: 6 inches H x 10-1/4 inches W x 4
inches D (152 mm H x 260 mm W x 102 mm D).
Power: 12V AC at 0.75A max.
Enclosure: Vandal-resistant.
a.
Color: Nickel.
b.
Color: Silver.
c.
Color: Gray.
System Components:
a.
LiftMaster RFMODKT3 315 MHz RF Module for remote access with Passport
transmitters.
b.
LiftMaster WOMODKT Wiegand Module that supports 2 Wiegand-compatible
remote proximity card readers and keypads.
c.
LiftMaster ESSWOKSG Essex Wiegand-Compatible Keypad; single gang
mount.
d.
LiftMaster HIDWOKPRO HID Wiegand-Compatible Combination Keypad and
Proximity Reader.
e.
LiftMaster EL25DVRCAMKT DVR-Compatible Low-Lux Color Camera; 480
lines of resolution.
Mount: LiftMaster PED42 Pedestal; 42 inches (1067 mm) pad mount, 2 inches H x 2
inches W (51 mm H x 51 mm W) square black powder-coated pedestal.
Mount: LiftMaster PED64 Pedestal; 64 inches (1626 mm) in-ground mount, 2 inches H
x 2 inches W (51 mm H x 51 mm W) square black powder-coated pedestal.
p.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
28 13 00-11
D.
Commercial and Gated Community Telephone Entry System:
1.
Acceptable Product: LiftMaster EL2000 Telephone Entry for Commercial Application
and Gated Communities:
a.
Wiegand Input Module: Allows addition of card readers, remote keypads and
Passport receivers.
b.
RF Module: Allows access through gates/doors with standard rolling code
transmitters.
2.
Memory Chip Capacity: 2,000 users; programmable as directory codes (915 MHz),
access codes and cards.
3.
Standard Features:
a.
Remote Access Diagnostics: Unit will record the following alarms: Forced
door/gate, door/gate ajar, unit over/under voltage.
b.
Voice Prompts: Push-button provides ADA-compliant voice prompts for end
users.
c.
Line Noise Tolerance: Enhanced telephone connection to unit via modem.
d.
Legacy Database Conversion: Versa XS 4.0 software allows transfer of
information from existing Sentex system to new Sentex system.
e.
Programming: Versa XS 4.0 software allows control programming through
modem, unit keypad or direct laptop connection.
f.
Controllable System Relays: 4 independent relays can be set to activate
doors/gates; can function as strike, control, shunt, alarm or CCTV relays.
Activation time between 1 and 300 seconds.
g.
Call Forwarding: System will dial a pre-programmed telephone number when
the tenant is not at the monitored location. Access can be granted or denied
from remote location. Call forwarding can be programmed manually as needed
or time-activated to occur at scheduled intervals.
h.
Call Waiting: Resident can answer an access call from a visitor while in the
middle of another outside call. Resident can answer an outside call if on an
access call.
i.
Illuminated keypad.
j.
Non-Volatile Memory: In event of power failure, database information is
retained in memory allowing immediate start-up and operation when power is
restored.
k.
Separate Call Button: Initiates phone call to resident.
l.
Distinctive Ringing: Unique double ring on resident's telephone to distinguish
between a standard call and an access request call.
m.
Entry Codes: Codes can be time-restricted or established as one-time-use-only.
n.
Holiday Programming: Maximum of 16 holidays can be defined to override the
pre-defined lock/unlock schedules.
o.
Time Zones: Software manages up to 62 separate time zones with 3 segments
each for access/no access schedules.
p.
Anti-Passback: Waits for pre-programmed period of time before code or card
can be reused.
q.
Transaction Monitoring: Maximum of 4,000 transactions (date, time, unit ID and
transaction) stored in unit are retrievable for record of on-site activities.
r.
Battery backed clock/calendar including daylight savings and leap years.
s.
Automatic Gate/Door Unlock Schedule: Main or auxiliary access points can be
programmed to open at pre-defined times.
t.
Security Lockout: Locks out all users for a programmable period of time if
several invalid code attempts are made.
u.
Alarm Calling: System dials pre-defined telephone number to notify security
personnel of the alarm condition if door/gate is forced open or held open too
long.
v.
Remote Updates: Software updates accomplished through remote computer
and modem connection.
w.
Do Not Disturb: Assignable on tenant-by-tenant basis when programmed
28 13 00-12
manually through touch-tone telephone or by a pre-programmed schedule.
Lightning Protection: Installer shall provide external surge suppressors in
addition to surge protection inherent in the entry system.
y.
Auto Sensor Input: Programmable to automatically dial the residence when a
vehicle approaches the property.
Exit Reader: Provides reader for true anti-passback operation.
Camera: Integrates camera into system to provide live video directly to television or
monitor screen.
a.
Color low-lux camera compatible with DVRs.
Passport Control: Push-button remote control will operate LiftMaster Garage Door
Operators, Gate Operators and Commercial Door Operators. Requires Passport
receiver.
E-Z Scan: Cards and Passport transmitters can be programmed into the unit through
the card reader or radio receiver installed into one of the plug-in modules.
Dimensions: 15 inches H x 12 inches W x 3-5/8 inches D (381 mm H x 305 mm W x
92 mm D).
a.
Dimensions for EL2000SS: 16 inches H x 11.25 inches L x 3.25 inches D (406
mm H x 284 mm L x 83 mm D).
Power: 12V AC at 1.0A max.
Enclosure: Vandal-resistant cast aluminum alloy housing with 5-inch backlit LCD
screen that displays up to 4 lines with 20 characters per line.
a.
Enclosure for EL2000SS: Stainless steel housing.
b.
Color: Nickel.
c.
Color: Silver.
d.
Color: Gray.
e.
Color: Stainless Steel.
System Components:
a.
LiftMaster RFMODKT3 315 MHz RF Module for remote access with Passport
transmitters.
b.
LiftMaster WOMODKT Wiegand Module that supports 2 Wiegand compatible
remote proximity card readers and keypads.
c.
LiftMaster ESSWOKSG Essex Wiegand-Compatible Keypad; single gang
mount.
d.
LiftMaster HIDWOKPRO HID, Wiegand-Compatible Combination Keypad and
Proximity Reader.
e.
LiftMaster ELHTRKT EL2000 Display Heater.
f.
LiftMaster EL2000SSTKN, Trim Kit, Narrow
g.
LiftMaster EL2000SSTKW, Trim Kit, Wide
h.
LiftMaster EL25DVRCAMKT DVR-Compatible Low-Lux Color Camera; 480
lines of resolution.
Mount: LiftMaster PED42 Pedestal; 42 inches (1067 mm) pad mount, 2 inches H x 2
inches W (51 mm H x 51 mm W) square black powder-coated pedestal.
Mount: LiftMaster PED64 Pedestal; 64 inches (1626 mm) in-ground mount, 2 inches H
x 2 inches W (51 mm H x 51 mm W) square black powder-coated pedestal.
x.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
PART 3 EXECUTION
3.1
EXAMINATION AND PREPARATION
A.
Prepare surfaces using the methods recommended by the manufacturer for achieving the
best result for the substrate under the project conditions. If preparation is the responsibility of
another installer, notify Architect in writing of deviations from manufacturer's recommended
installation tolerances and conditions.
B.
Do not proceed with installation until substrates have been properly prepared and deviations
from manufacturer's recommended tolerances are corrected. Commencement of installation
28 13 00-13
constitutes acceptance of conditions.
3.2
3.3
3.4
C.
Clean surfaces thoroughly prior to installation.
D.
Prepare surfaces using the methods recommended by the manufacturer for achieving the
best result for the substrate under the project conditions.
INSTALLATION
A.
Install in accordance with manufacturer's instructions including but not limited to the
following:
1.
Mount directly to concrete pad, firmly secured, plumb and level.
2.
Mount to mounting pedestal; provide base plate.
3.
Wire in accordance with National Electric Code.
4.
Enclose all splices in easily accessible junction boxes or on terminal boards.
5.
Tag and identify all cable runs in all junction boxes.
B.
Test system and adjust to assure components and accessories are properly connected and
in working order.
C.
Wiring shall be in accordance with national electric codes and manufacturer's instructions.
Make conduit and wiring connections to existing gate and door hardware devices as
required.
D.
Install wiring for detection and signal circuit conductors in conduit. Use 22 AWG minimum
size conductors.
PROTECTION
A.
Protect installed products until completion of project.
B.
Touch up, repair or replace damaged products before Substantial Completion.
MAINTENANCE
A.
Maintain at 3-month intervals during specified maintenance period, checking external
reversing devices once per month.
END OF SECTION
28 13 00-14