1 Inductive sensor NBB10-30GM60-A2

Inductive sensor
NBB10-30GM60-A2
Dimensions
60
5
M30 x 1.5
36
LED(s)
Model Number
NBB10-30GM60-A2
Technical Data
Features
•
10 mm embeddable
Connection
BN
BK
L+
WH
BU
L-
Accessories
BF 30
Mounting flange, 30 mm
EXG-30
Quick mounting bracket with dead stop
General specifications
Switching element function
Rated operating distance
sn
Installation
Output polarity
Assured operating distance
sa
Reduction factor rAl
Reduction factor rCu
Reduction factor r304
Nominal ratings
Operating voltage
UB
Switching frequency
f
Hysteresis
H
Reverse polarity protected
Short-circuit protection
Voltage drop
Ud
Operating current
IL
Off-state current
Ir
No-load supply current
I0
Indication of the switching state
Functional safety related parameters
MTTFd
Mission Time (TM)
Diagnostic Coverage (DC)
Ambient conditions
Ambient temperature
Mechanical specifications
Connection type
Core cross-section
Housing material
Sensing face
Protection degree
Compliance with standards and directives
Standard conformity
Standards
PNP
NO/NC
10 mm
embeddable
DC
0 ... 8.1 mm
0.25
0.15
0.66
10 ... 30 V
0 ... 200 Hz
typ. 5%
reverse polarity protected
pulsing
≤3V
0 ... 200 mA
0 ... 0.5 mA typ. 0.1 µA at 25 °C
≤ 20 mA
LED, yellow
1140 a
20 a
0%
-25 ... 70 °C (-13 ... 158 °F)
cable PVC , 2 m
0.34 mm2
brass, nickel-plated
PBT
IP67
EN 60947-5-2:2007
IEC 60947-5-2:2007
Approvals and certificates
cULus Listed, General Purpose
cCSAus Listed, General Purpose
Products with a maximum operating voltage of ≤36 V do not bear a
CCC marking because they do not require approval.
Release date: 2011-07-14 10:56
Date of issue: 2012-02-03 083859_eng.xml
UL approval
CSA approval
CCC approval
Subject to modifications without notice
Pepperl+Fuchs Group
USA: +1 330 486 0001
www.pepperl-fuchs.com
[email protected]
Germany: +49 621 776-4411
[email protected]
Copyright Pepperl+Fuchs
Singapore: +65 6779 9091
[email protected]
1