© Siemens AG 2009 Digital Single- and Three-Phase E-Counters for Active and Reactive Energy BETA Low-Voltage Circuit Protection The E-counters (power meters) are used to record the amount of electrical energy exported or imported. Siemens compact E-counters are designed as modular devices for alternating current and can be mounted on standard mounting rails. They comply with the counter standard EN 50470 (Part 1 and 3) and come with an LCD. Direct connection up to 80 A, transformer current connection up to .../5 A The product spectrum includes single-phase and three-phase counters for direct connection up to 80 A. Among the three-phase counters there are also versions with transformer current connection (…/5 A to 10000/5 A). The E-counters save both active and reactive energy and they all comply with accuracy class 1 (for active energy). Highlights Compliant with the new counter standard EN 50470 (Part 1 and 3) Easy-to-read LCD Versions calibrated in accordance with the new Measuring Instruments Directive 2004/22/EC (MID) can be used for invoicing purposes Exact recording thanks to accuracy class 1 (for active energy) Answers for infrastructure. © Siemens AG 2009 Single-Phase and Three-Phase Measuring Devices 7KT1 5 digital measuring devices Overview All E-counters have a pulse output (S0) and are designed for 1-tariff or 2-tariff measurements depending on the version. The calibrated versions are in accordance with the new Measuring Instruments Directive 2004/22/EC (MID). In the case of non-calibrated E-counters, the registers can be reset. At the same time the E-counters have an integrated optical interface (IrDA) for connecting communication modules. Integration of the E-counters, e.g. in energy management systems, is thus possible. Benefits Single-phase energy counters • Direct connection up to 80 A Calibrated versions (MID) A) Space for device name and approval data. B) Seal between the top and bottom of the enclosure. 2 Single-Phase and Three-Phase Measuring Devices Three-phase energy counters • Direct connection up to 80 A / Transformer current connection ... /5 A © Siemens AG 2009 Technical specifications Single-phase E-counter, direct connection up to 80 A 7KT1 530 Standards Connection • Direct connection General data • Enclosure width • Mounting • Mounting height EN 50470-1, EN 50470-3, EN 62053-23, EN 62053-31 A 80 MW mm mm 2 35 70 conductors n1 n2 2 yes T1 -- Supply (through measuring terminals) • Rated control supply voltage Un • Voltage range V AC V 230 184 ... 276 Rated frequency fn • Rated power dissipation Pv Hz VA (W) 50 ≤8 (0.6) Continuous operation Short-time operation for (1 s) V V 276 300 Continuous operation Short-time operation for (10 ms) A A 80 2400 LCD Digit dimensions digits mm x mm 7 (1 decimal point) 6x3 Tariff/tariffs Max display (continuous) Tariff/Tariffs Max display (continuous) kWh kWh kvarh kvarh 000000.0 ... 999999.9 999999.9 ... 000000.0 000000.0 ... 999999.9 999999.9 ... 000000.0 Function • Operating mode • Storage of setting and count • Tariff for active and reactive energy Overload capability • Voltage Un • Current Imax Display • Display • Active energy: 1 display, 7-digit + display import or export (arrow) • Reactive energy: 1 display, 7-digit + display import or export (arrow) Acc. to DIN 43880 Acc. to EN 60715 Single-phase loads Through (EEPROM) 7KT1 531 7KT1 533 80 (MID) -T1 + T2 000 ... 999 W, kW, MW var, kvar, Mvar 000 ... 999 • Instantaneous active power: 1 display, 3-digit • Instantaneous active power: 1 display, 3-digit 1 T1 • Current tariff 1 display, 1-digit • Display period T1/T2 1 s Measuring accuracy At 23 ±1 °C based on nominal value • Active energy and active power • Reactive energy and reactive power Acc. to EN 50470-3 Acc. to EN 62053-23 % % ±1 (B) ±2 Phase/N Phase/N V AC direct 184 ... 276 Direct connection A A A 15 0.75 0.0025 ... 80 Hz 50 Symmetrical sinusoidal 25 Measuring input • Connection type • Operating range voltage • Current Iref • Current Imin • Operating range current (Ist … Imax) • Frequency • Current waveform • Operational starting current Ist S0 interface mA Acc. to EN 62053-31 • Pulse outputs - Absorbed for active and reactive energy T1 - Absorbed only for active and reactive energy T1 and T2 • Pulse count • Pulse duration • Required voltage • Permissible current • Permitted current yes -Pulse/kWh ms V AC V DC 1000 30 ±5 ms 5 ... 230 ±5 % 5 ... 300 Pulse ON (max. 230 V AC/DC) Pulse OFF (Residual current max. 230 V AC/DC) mA µA 90 1 LED Pulse/kWh 1000 -yes Optical interfaces • Calibration from the front (accuracy check) IR interface • At the side for connecting communication modules (LAN-TCP/IP / M-Bus / Modbus RTU / RS-485 / KNX / Profibus DP-VO) Safety -- Acc. to EN 50470-1 • For indoor areas • Overvoltage category • Operational voltage • Test voltage yes yes 1.2/50 µs V kV 4 300 6 Single-Phase and Three-Phase Measuring Devices 3 © Siemens AG 2009 Single-phase E-counter, direct connection up to 80 A • Flame resistance 7KT1 530 UL 94 Class V0 Screw head Z ± POZIDRIV Blade for slotted screw mm PZ2 0.8 x 3.5 • Conductor cross-sections of operational current and main current paths - Rigid min. (max.) - Flexible with sleeve min. (max.) mm2 mm2 1.5 ... 35 1.5 ... 35 • Conductor cross-sections for S0 pulse outputs - Rigid min. (max.) - Flexible with sleeve min. (max.) mm2 mm2 0.14 ... 2.5 0.14 ... 2.5 7KT1 531 7KT1 533 Terminal connections • Lift terminals of main current paths • Lift terminals for S0 pulse outputs Ambient conditions • Mechanical environment • Electromagnetic environment M1 E2 • Operating temperature • Temperature limits for storage and transport • Relative humidity (without condensation) • Vibrations • Degree of protection Sinus amplitude at 50 Hz Installed device Front side/terminals °C -10 ... +55 -25 ... +70 °C ≤ 80 mm ± 0.075 IP51*)/IP20 * For installation in a distribution board with at least IP51 degree of protection. Technical specifications Three-phase E-counter Direct connection up to 80 A / Transformer current connection .../5 A 7KT1 543 7KT1 545 Standards Connection • Direct connection • Transformer current connection EN 50470-1, EN 50470-3, EN 62053-23, EN 62053-31 80 -- General data • Enclosure width • Mounting • Mounting height Acc. to DIN 43880 Acc. to EN 60715 MW mm mm 4 35 70 Function • Operating mode • Storage of setting and count • Tariff for active and reactive energy three-phase loads Through (EEPROM) conductors n2 2-3-4 yes T1/T2 Supply (through measuring terminals) • Rated control supply voltage Un • Voltage range V AC V 230 184 ... 276 • Rated frequency fn • Rated power dissipation Pv Hz VA (W) 50 ≤ 8 (0.6) Continuous operation: phase/phase 1 second: phase/phase Continuous operation: phase/N 1 second: phase/N V 480 V V V 800 276 300 Continuous operation Short-time operation for (0.5 s) Short-time operation for (10 ms) A A A 80 -2400 Display of rotating field error LCD Digit dimensions digits mm x mm PHASE Err 8 (1 decimal point) 6x3 Tariff/tariffs Max display (continuous) Tariff/Tariffs Max display (continuous) kWh kWh kvarh kvarh 000000.0 ... 999999.9 999999.9 ... 000000.0 000000.0 ... 999999.9 999999.9 ... 000000.0 Overload capability • Voltage Un • Current Imax Display (readout) • Connection error and phase failure • Display • Active energy: 1 display, 8-digit + display import or export (arrow) • Reactive energy: 1 display, 8-digit + display import or export (arrow) -.../5 3-4 120 -- 000 ... 999 W, kW, MW var, kvar, Mvar 000 ... 999 • Instantaneous active power: 1 display, 3-digit • Instantaneous reactive power: 1 display, 3-digit 4 A A 7KT1 540 • Display tariff identification • Transformer primary current • Display period 1 display, 1-digit Measuring accuracy At 23 ±1°C based on nominal value • Active energy and active power • Reactive energy and reactive power Acc. to EN 50470-3 Acc. to EN 62053-23 s Single-Phase and Three-Phase Measuring Devices % % T1/T2 -2 ±1 (B) ±2 5 ... 10000 © Siemens AG 2009 Three-phase E-counter Direct connection up to 80 A / Transformer current connection .../5 A 7KT1 543 7KT1 545 7KT1 540 direct 400 230 Transformer-CT-TA-TC .../5A V V A A A 15 -0.75 -5 0.05 A A A A 0.0025 ... 80 ---- -0.010 ... 6 5 ... 10000 5 Hz 50 Symmetrical sinusoidal 25 10 Measuring input • Connection type • Voltage Un phase/phase phase/N • Current Iref • Current In • Current Imin • Operating range current (Ist … Imax) • Transformer current Direct connection Transformer connection Primary current of the transformer Smallest input step • Frequency • Input ripple form • Operational starting current Ist S0 interface mA Acc. to EN 62053-31 • Pulse outputs - Absorbed for active and reactive energy T1 + T2 yes Pulse/kWh Pulse/kWh ms -500 -30 ±5 ms V AC V DC 5 ... 230 ±5 % 5 ... 300 Pulse ON (max. 230 V AC/DC) Pulse OFF (Residual current max. 230 V AC/DC) mA µA 90 1 LED Pulse/kWh 1000 • Pulse quantity - At 75 A - Can be set on transformer, see table • Pulse duration • Required voltage • Permissible current • Permitted current -100-10-1 Optical interfaces • Calibration from the front (accuracy check) 10000 IR interface • At the side for connecting communication modules (LAN-TCP/IP / M-Bus / Modbus RTU / RS-485 / KNX / Profibus DP-VO) yes • Front-accessible for data readout (acc. to EN 62056-21 over IR measuring head) ja Safety • • • • • • Acc. to EN 50470-1 For indoor areas Overvoltage category Operational voltage Test voltage 1.2/50 µs Flame resistance UL 94 Seal between the top and bottom of the enclosure (mod. 7KT1 533) V kV Class yes 4 300 6 V0 yes Terminal connections • Lift terminals of main current paths • Lift terminals for S0 pulse outputs Screw head Z ± Blade for slotted screw • Conductor cross-sections of operational current and main current paths - Rigid min. (max.) - Flexible with sleeve min. (max.) • Conductor cross-sections for S0 pulse outputs - Rigid min. (max.) - Flexible with sleeve min. (max.) POZIDRIV mm PZ2 0.8 x 3,5 PZ1 mm2 mm2 1.5 ... 35 1.5 ... 35 1,5 ... 6 1,5 ... 6 mm2 mm2 0.14 ... 2.5 0.14 ... 1.5 Ambient conditions • • • • • • • Mechanical environment Electromagnetic environment Operating temperature Temperature limits for storage and transport Relative humidity (without condensation) Vibrations Degree of protection Sinus amplitude at 50 Hz Installed device Front side/terminals °C °C mm M1 E2 -10 ... +55 -25 ... +70 ≤ 80 ± 0,075 IP51*)/IP20 * For installation in a distribution board with at least IP51 degree of protection. Single-Phase and Three-Phase Measuring Devices 5 © Siemens AG 2009 Selection and ordering data (dated 08/2009) Un Imax V AC AC A MW Order No. PS*/ P. unit Weight 1 unit approx. Unit(s) kg Digital single-phase E-counters • For direct connection, single rate 230 • For direct connection, double rate • For direct connection, double rate, calibrated version 80 4 7KT1 530 7KT1 531 7KT1 533 1 1 1 0,164 0,164 0,164 80 4 7KT1 543 7KT1 545 1 1 0,386 0,386 7KT1 540 1 0,386 Digital three-phase E-counters • For direct connection, double rate 230 • For direct connection, double rate, calibrated version • For transformer connection, double rate Transformer .../5 * You can order this quantity or a multiple thereof. Dimensional drawings 36 7KT1 530 6 36 4 5 44 64 7KT1 531 7KT1 533 Single-Phase and Three-Phase Measuring Devices 1 2 3 4 5 L1 L2 L3 L1 L2 L3 90 45 90 6 N L1L2 L3k1I1 k2I2k3 I3 72 7KT1 543 7KT1 545 45 90 3 90 2 72 7KT1 540 I202_02065 N 1 I202_02069 L I202_02068 L I202_02065 N I202_02067 L 90 90 I202_02066 L N 12345 345 6 44 64 © Siemens AG 2009 Schematics 230 V AC S0 S0 L N ~ ~ ~ + - + S0 S0 ~ ~ ~ + - + 3 1 5 4 2 3 5 4 Tariff kWh kvar kWh L1 L1 N kvar L1 L1 N L1 80 A L1 80 A N N I202_02070 I202_02071 230/400 V AC 230/400 V AC 7KT1 530 7KT1 531, 7KT1 533 S0 S0 ~ ~ ~ ~ + - + - 230 V AC L N 1 N 2 3 4 5 230 V AC L 6 N Tariff 1 N 2 S0 S0 ~ ~ ~ ~ + - + 3 4 5 6 Tariff kWh kvar kWh L1 L1 L2 L2 L3 L3 kvar L1 L1 L2 L2 L3 L3 L1 80 A L1 80 A L2 80A N L3 80A 230/400 V AC N I202_02074 I202_02072 230/400 V AC 7KT1 543, 7KT1 545 7KT1 543, 7KT1 545 To achieve the specified accuracy, the N-conductor must be connected to the counter. With single-phase connection the display lighting cannot be activated. 230 V AC L 1 N N 2 S0 S0 ~ ~ ~ ~ + - + 3 4 5 6 Tariff kWh kvar k1 L1 l1 k2 L2 l2 k3 L3 l3 6A 6A 6A k l k l k l K L K L K L L1 L2 L3 N 230/400 V AC I202_02073 7KT1 540 Single-Phase and Three-Phase Measuring Devices 7 © Siemens AG 2009 More information Digital single-phase E-counters, display presentation • Green, backlit LCD • The control button is used to select the different display levels. Power import indicator ( Power dissipation indicator ( kvarh indicator ) ) kWH indicator Selected / current rate Energy value Indicator for inductive power Is indicated when the energy result is negative Indicator for capacitive power Bar chart (in percent of Imax) Indicator for active and reactive power Device designation and approval data Control key for readout LED accuracy monitoring indicator Operation Digital three-phase E-counters, display presentation • Green, backlite LCD • The control button is used to select the different display levels. kWh Kvarh kWh indicator kvarh indicator Power import indicator ( Power export indicator ( T12 →) ←) Selected / active tariff Phase value of energy display (L1-2-3) and ΣL Phase total of energy display Indicator for inductive power Indicator for capacitive power Indicator for active and reactive power Indicator for the current transformer ratio, primary side Bar diagram (in percent of Imax) Device name and approval data LED accuracy check indicator Control button Siemens AG Industry Sector Building Technologies Division Electrical Installation Technology Postfach 10 09 53 93009 REGENSBURG GERMANY www.siemens.com/beta Subject to change without notice PDF only: (E10003-E38-9T-B2131-7600) PI 0809 En © Siemens AG 2009 The information provided in this brochure contains descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. Availability and technical specifications are subject to change without notice. All product designations may be registered trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes may violate the rights of the owner.
© Copyright 2026 Paperzz