Field Loading Test on Micropile Foundation regarding the Effect of Prestress IWM2003 in Seattle Kinya Miura: GeoMechanics Group, Faculty of Engineering, Toyohashi University of Technology We conducted two series of loading tests for the effect of prestress. Model loading tests on the footings reinforced with Prestressed Micropiles got an idea of prestressing micropiles Field loading tests on the footings reinforced with Prestressed Micropiles made sure of the idea Details of the tests are in the two conference papers distributed A measure for the improvement of bearing capacity by micropiles qv FT-MP-Test R= Qv/As qv FT-Test MP-Test + The ratio R was calculated from three types of loading tests: calling “Index of Network Effect” Improvement Ratio, R Improvement observed in laboratory loading tests 2.4 2.0 MP-FD-Test S-R-Type, n=8, =0deg., L=100 mm 1.6 Dense 1.2 R=1 0.8 Medium 10% 5% Relateve Displacement, Loose 20% Sv/D Confining effect by micropile group Confining effect is enhanced by positive dilatancy of ground material, but not by negative dilatancy. Prestress (tension) in MPs To overcome the disadvantage of negative dilatancy, the idea of prestress occurred. Laboratory Loading Tests Model footing for applying prestress Normalized Vertical Load, qv (kPa) Test results for medium dense sand ground 150 k = 0.0 Medium ground 0.57 0.41 0.36 0.17 100 Total Load carried by FT-PSMP 0 -50 Vertical Load on Micropiles Qmp/Af (kPa) -Qmp0/Qmpmax=0 50 0 2 4 6 8 10 150 100 -Qmp0/Qmpmax=0 50 0.57 0 -50 0 2 4 6 8 Load by micropile group start with negative values 10 Base Pressure qv - Qmp/Af (kPa) 150 0.57 100 0.41 0.36 0.17 50 0 -50 -Qmp0/Qmpmax=0 0 2 4 6 8 10 Vertical Displacement, Sv (mm) Load by footing base base pressure is enhanced by the prestress. Test results for medium dense sand ground 150 k = 0.0 Medium ground Sv/B = 5% 100 qf Normalized Vertical Load, qv (kPa) 50 qv Qmp/Af 0 0.0 0.1 0.2 0.3 0.4 0.5 0.6 150 Sv/B = 10% 100 qv Bearing capacity was improved even under small displacement and on non-dilative soil ground qf 50 Qmp/Af 0 150 0.0 0.1 0.2 0.3 0.4 0.5 Sv/B = 20% 0.6 qv 100 qf 50 Qmp/Af 0 0.0 0.1 0.2 0.3 0.4 0.5 Prestresss Ratio, -Qmp0/Qmpmax 0.6 Ratio R was greater than 1.3 Field Loading Tests The boring log and the Nvalue of the upper 10 meters is presented The subsoils were fill, loam, cemented clay, sandy clay, and fine sand, respectively. The fill, loam and clay were soft and rather uniform mechanically; the N-values are less than 5. Plan view of test site Illustration of Micropile (MP) The micropile was 3 m long, 100 mm in diameter, with a steel core-rod of 32 mm in diameter (a) S-MP (b) FT-MP/FT-PSMP Application of prestress with jacks Loading in vertical direction (FT-MP/FT-PSMP test) Loading in horizontal direction (sectional view) Setup for horizontal loading Load, P (kN) FT loading test 4 3 2 200 200 160 150 120 100 80 50 40 0 0 1 Elapsed time, t (hour) 0 0 Residual deformation Elastic deformation 50 100 150 200 Pmax = 210 kN, Smax = 181.43 mm 250 Load, P (kN) S-MP loading test 120 160 200 5 4 3 2 40 30 32 24 24 18 16 12 8 6 0 0 1 Elapsed time, t (hour) 6 Pmax = 30 kN, Smax = 28.69 mm 12 18 24 30 0 0 Settlement, S (mm) 80 Load, P (kN) Settlement, S (mm) 40 Settlement, S (mm) 5 250 Settlement, S (mm) Loading test on FT and MP Residual deformation Elastic deformation 8 16 24 32 40 Load, P (kN) Vertical loading test on FT-MP and FT-PSMP Load, P (kN) FT-MP loading test 240 360 180 240 120 120 60 0 0 2 0 0 Py = 240 kN Pult = 560 kN 120 240 360 480 600 Load, P (kN) Elapsed time, t (hour) Settlement, S (mm) 60 120 180 FT-PSMP loading test 240 300 Pmax = 600 kN Smax = 227 mm Py = 240 kN Pult = 600 kN 8 6 4 600 300 480 240 360 180 240 120 120 60 0 0 2 Elapsed time, t (hour) 0 0 Settlement, S (mm) 4 480 Smax = 243 mm Residual deformation Elastic deformation Load, P (kN) 6 300 Residual deformation Elastic deformation 120 240 360 480 600 Load, P (kN) 60 Settlement, S (mm) 8 600 Settlement, S (mm) Pmax = 560 kN 120 180 240 300 Effect of prestress on bearing capacity of FT with MP group Load (kN) 0 100 200 300 400 500 600 700 0 50 Settlement, S (mm) 100 FT-PSMP 150 200 250 FT 300 FT+8MPs FT-MP The bearing capacity of FT reinforced with MPs is remarkably increased. The bearing capacity of prestressed MP group (FTPSMP) is 7% higher than FT-MP group. Settlement of MP group is reduced 16.4% due to prestress (FT-PSMP). Horizontal loading test on FT-MP and FT-PSMP Pmax = 30 kN 2 1 16 18 12 12 8 6 4 0 0 Elapsed time, t (hour) 6 0 0 6 max = 27.45 mm 12 18 24 30 Load, P (kN) Horizontal displ, S (mm) 12 18 FT-PSMP horizontal loading test 24 30 5 4 3 2 1 Elapsed time, t (hour) Pmax = 30 kN max = 13.84 mm 30 20 24 16 18 12 12 8 6 4 00 6 12 18 24 30 0 0 Horizontal displacement, S (mm) 3 24 Residual deformation Elastic deformation Load, P (kN) 4 20 Horizontal displacement, S (mm) 5 30 Horizontal displ, S (mm) Load, P (kN) FT-MP horizontal loading test 6 Residual deformation Elastic deformation 12 18 24 30 Load, P (kN) Effect of prestress on horizontal movements Horizontal load (kN) 0 5 10 15 20 25 30 0 Horizontal displacement (mm) 5 10 15 FT-PSMP 20 25 FT-MP 30 The effect of prestress on horizontal movement control was significant. The lateral movement was increased rather linearly with load in the nonprestress group (FT-MP). y = 13.84 mm in the prestressed group (FTPSMP). Conclusions (Laboratory Tests) The bearing capacity of footing is improved by the interaction between footing, subsoil and micropile group, and induce confining effect on the subsoil. The prestress is effective to enhance the confining effect, even at the beginning of loading and on non-cohesive soil ground, such as loose sand and soft clay. Conclusions (Field Tests) The effect of prestress on the improvement of bearing capacity is significant: vertical bearing capacity was increased by 7% in prestressed MP group (FT-PSMP) than in the nonprestressed MP group (FT-MP). Coefficient of subgrade reaction was remarkably improved. (more than twice in both vertical and horizontal directions) 1.86×104 kN/m3 (FT-MP), 3.97×104 kN/m3 (FT-PSMP) in Vertical 1.01×103 kN/m3 (FT-MP), 1.71×104kN/m3 (FT-PSMP) in Horizontal Thank you for your attention! End of the presentation
© Copyright 2026 Paperzz