PDL LS45 LS 55 Feb 2010

Product
Description
List
LS-45 & LS-55 Luminescence
Spectrometers
Table of Contents
Page
Introduction ...................................................................................................................................... 2
LS-55 Fluorescence Spectrometer .................................................................................................. 3
LS-45 Fluorescence Spectrometer
4
Sampling Accessories ...................................................................................................................... 5
Thermostated Cell Holders
5
Well Plate Reader Accessory
5
Total Emission Accessory
6
Front Surface Accessory
6
LC Flow Cell Accessory
6
Sipper Cell and Pump Accessory
6
Low-temperature Accessory
6
Remote Fiber Optic Accessory
6
Fluorescence Liquid Autosampler
7
Polarization
7
Software Upgrades and Add-On Software Applications .................................................................. 8
Intracellular Ion Measurements ........................................................................................................ 9
Intracellular lon Filter Guide
9
Intracellular Ion Accessory
9
Intracellular Ion Filter Sets
9
Cells for Fluorimetry ....................................................................................................................... 10
Reference Materials and Test Samples ......................................................................................... 10
Sources, Detectors, Attenuators, Filters and Septa ....................................................................... 11
Recommended Minimum Computer Configuration ........................................................................ 11
PerkinElmer Life and Analytical Sciences
710 Bridgeport Avenue
Shelton, CT 06484-4794
U.S.A.
(800) 762-4000 or
Tel.:(+1) 203-925-4602
Fax: (+1) 203-944-4902
FLR-PDL9
Product Description List is subject to change without notice.
February 2009
1
Introduction
Fluorescence Spectroscopy is an analytical technique used for a wide variety of
applications including cuvette based and plate based measurements. PerkinElmer offers
accessories and software that are designed to satisfy the needs of the many different
application fields.
The LS-55 is the gold standard for automated chemical and biological research. It is a
scanning Fluorescence Spectrometer covering the wavelength range of 200–800 nm
with the excitation monochromator and 200–900 nm with the emission monochromator.
The instrument has variable slits on both the excitation (2.5 to 15nm) and emission (2.5
to 20 nm) monochromators. The instrument can measure fluorescence, time resolved
fluorescence, phosphorescence and luminescence. Therefore this instrument can be
used for a wide range of applications and accessory options and serves as a base for
the application systems.
The LS-45 provides affordable performance for routine analyses. It is a scanning
Fluorescence Spectrometer covering the wavelength range of 200–800 nm with the
excitation monochromator and 200–900 nm with the emission monochromator. The
instrument has fixed slits (10 nm) on both the excitation and emission monochromators.
Both instruments are fully computer controlled systems using FL WinLab. FL WinLab,
a Windows based software package, controls the instrument, sampling accessories,
data collection and data processing. The software provides specific applications such as
Scan, Synchronous scanning, Time Drive, Ratio Data Collection, ICBC Calibration, Well
Plate Reader and 3D view.
FLR-PDL9
Product Description List is subject to change without notice.
February 2009
2
LS-55 Fluorescence Spectrometer
Application:
Fluorescence spectrometer that can be configured with software and
accessories to address a wide range of application requirements.
L2250107 (220-240V)
L2250117 (110V)
Description:
Versatile, computer controlled Fluorescence spectrometer; incorporates a
8.3 watt, pulsed xenon source for fluorescence and phosphorescence
decay time measurements.
Excitation 200–800 nm and emission 200–900 nm with zero order
selectable. Standard PMT covers 200–650 nm; R928 or R955 PMT
optionally available for full range. Synchronous scanning with constant
wavelength or frequency difference included. Excitation spectra are
automatically corrected. Uses holographic excitation grating for reduced
stray light levels.
Variable excitation 2.5–15 nm and emission 2.5 to 20 nm slits in 0.1 nm
increments. Scan speeds can be selected in 1 nm increments from 101500 nm/minute.
Includes Single-position, water-thermostatted cell holder and Septum
injector
Incorporates a software-controlled filter wheel in the emission
monochromator with 290, 350, 390, 430 and 515 nm cutoff filters, 1% T
attenuator and clear beam.
Includes automated polarization accessory that consists of 2 filter
wheels; each wheel containing a horizontal and vertical polarizing element.
Polarizer positions are software controlled and can be manually set or
automatically controlled for polarization, anisotropy or G-factor
Includes sample compartment purge nipple to allow dry air or nitrogen to
be blown into the sample area to prevent the optics fogging for low
temperature applications.
FL WinLab Software Package, Windows based software controls
the instrument, sampling accessories and data collection. The software
provides specific applications such as Scan, Time Drive, Ratio Data
Collection, ICBC Calibration, Well Plate Reader and 3D view.
1V and 10 mV analog output.
L2250107 Configured for operation with 220-240 VAC, 50/60 Hz.
L2250117 Configured for operation with 110 VAC, 50/60Hz
System Components:
LS-55 Spectrometer including Users Guide
FL WinLab Software including Users Guide
RS232C Cable
Single-position, water-thermostatted cell holder
Not Included
B0631104
B0631107
FLR-PDL9
Personal Computer and Printer – See computer section for configurations
Recommended Consumables and Spare Parts for the LS-55:
Rectangular Cell, OS, 10 x 10 mm, PTFE Lid - 10 x 10 mm pathlength,
Special Optical Glass, 3.5 mL volume. Set of 2
Rectangular Cell, QS, 10 x 10 mm, PTFE Lid - 10 x 10 mm pathlength. In
Far UV fused silica, Quartz SUPRASIL, 3.5 mL volume. Set of 2.
Product Description List is subject to change without notice.
February 2009
3
LS-45 Fluorescence Spectrometer
Application:
Luminescence spectrometer that can be configured with software and
accessories to address a wide range of application requirements.
The LS-45 spectrometer is NOT suitable for polarization
and Bioluminescence measurements.
L2250106 (220-240V)
L2250116 (120V)
Description:
Versatile, computer controlled Fluorescence spectrometer;
incorporates a 9.9 watt, pulsed xenon source for fluorescence and
phosphorescence decay time measurements.
Excitation 200–800 nm and emission 200–900 nm with zero order
selectable. Standard PMT covers 200–650 nm; R928 or R955 PMT
optionally available for full range.. Synchronous scanning with constant
wavelength or frequency difference included. Excitation spectra are
automatically corrected.
Fixed excitation and emission slits (10 nm). Scan speeds can be
selected in 1 nm increments from 10-1500 nm/minute.
Manual 1%T attenuator for signal attenuation and validation
FL WinLab Software Package, Windows based software controls the
instrument, sampling accessories and data collection. The software
provides specific applications such as Scan, Time Drive, Ratio Data
Collection, ICBC Calibration and 3D view.
1V and 10 mV analog output.
L2250106 Configured for operation with 220-240 VAC, 50/60 Hz.
L2250116 Configured for operation with 110 VAC, 50/60Hz
System Components:
LS-45 Spectrometer including Users Guide
FL WinLab Software including Users Guide
RS232C Cable
Single-position, water-thermostatted cell holder
L2250162
Accessory PCB Kit for the LS-45. Allows the LS-45 to be used with the
PTP-1 (L2250150), biokinetic (L2250145) and Sipper (L2250135)
accessories
Requires installation by a service engineer
Not Included
Personal Computer and printer– See computer section for configurations
B0631104
Recommended Consumables and Spare Parts for the LS-45:
Rectangular Cell, OS, 10 x 10 mm, PTFE Lid - 10 x 10 mm pathlength,
Special Optical Glass, 3.5 mL cell volume. Set of 2
B0631107
FLR-PDL9
Rectangular Cell, QS, 10 x 10 mm, PTFE Lid - 10 x 10 mm pathlength. In
Far UV fused silica, Quartz SUPRASIL, 3.5 mL volume. Set of 2.
Product Description List is subject to change without notice.
February 2009
4
Sampling Accessories
Thermostated Cell Holders
L2250140
Single position thermostated Cell Holder - Cell holder for a 10 mm pathlength cell,
water thermostated. This cell holder is included with the instrument.
L2250141
Single position thermostated Cell Holder - Cell holder for a 10 mm pathlength cell,
water thermostated with stirrer. . Includes 6 stirrer fleas (04978499).
L2250134
Four position Thermostated Automatic Cell Changer with Stirrer for LS55 - Cell holder
accommodates four 10 mm pathlength cell or four microcells with four adapters
(L2250139). All positions are stirred simultaneously. Includes six stirrer fleas
(04978499).
This accessory is NOT compatible with the LS-45
L2250145
Bio-Kinetic Accessory - Magnetically stirred single cell holder; water thermostated.
Includes a built-in temperature sensor (range 0 to 100 C) and an event marker.
Thermostatable by means of an external water bath (not included). Accommodates
10 mm pathlength cuvettes. Includes 6 stirrer fleas (04978499).
If stirring capability is required, LS-45 requires accessory PCB kit (L2250162)
L2250150
PTP-1 Single Position Research Peltier Controller for fluorescence. Temperature
range 0 to 100 C. Includes Biokinetic Accessory (L2250145) which includes stirring,
event marking and temperature sensing as an integral part of the accessory as well
as controller box. Control is either via the keypad or TempScan software (L225B009).
Please note that this accessory requires a source of liquid cooling such as the PCB
150 Peltier Chiller Bath (N1015158). Voltage supply selectable between 110 and
240V
If stirring capability is required, LS-45 requires accessory PCB kit (L2250162)
N1015158
PCB 150 Peltier Chiller Bath. Can be used either with the Water thermostated cell
holders (L2250140, L2250134, L2250145) or as a cooling device for the PTP-1
Research Peltier (L2250150) Temperature range 20 to 60 C
04978499
Magnetic Stirrer Fleas - Package of 6.
Well Plate Reader Accessory
L2250042
Well Plate Reader Accessory - For measuring fluorescence or phosphorescence in 6,12-, 24-, 48-, or 96-well plates or for luminescence microdensitometry of TLC plates
and electrophoresis gels. Controlled by the computer. Silica excitation and emission
fibers for measurement above 260nm excitation and emission. Includes one pack of
white microplates.
Plate reader provides top reading facility only and can be used for fluorescence and
time-resolved fluorescence/ phosphorescence. It cannot be used to measure chemior bio- luminescence.
This accessory is NOT compatible with the LS-45
6005290
Optiplate 96 well plate with flat bottom, white. Pack of 50
6005299
Optiplate 96 well plate with flat bottom, white. Pack of 200
6005270
Optiplate 96 well plate with flat bottom, black. Pack of 50
6005279
Optiplate 96 well plate with flat bottom, black. Pack of 200
FLR-PDL9
Product Description List is subject to change without notice.
February 2009
5
Total Emission Accessory
L2250101
Total Emission Accessory - Enhances sensitivity by automatically placing a mirror in
front of the emission grating. Essential for high sensitivity bio- and
chemiluminescence measurements using cuvette holder. Requires, but does not
include installation by a PerkinElmer Service Engineer (N0207173).
This accessory is NOT compatible with the LS-45
N0207173
Service Installation
Front Surface Accessory
52123130
Front Surface Accessory - For flat samples, powders and turbid samples. Includes
two Powder Sample Holders (52123164). Adjustable for optimizing sensitivity.
52123164
Powder Sample Holder - Used with front surface accessory (52123130).
52123814
Synthetic Fused Silica Window - For Powder Sample Holder
LC Flow Cell Accessory
L2250138
LC Flow Cell Accessory – Includes 1.3 mm square section, 16 L volume synthetic
fused silica flow cell (L2151247), 0.4 mm FEP inlet tube (L2151202); and 0.7 mm
FEP outlet tube (L2151203).
L2151202
0.4 mm ID FEP Inlet Tube to Flow Cell – Used as inlet tube for L2250138. Package
of five.
L2151203
0.7 mm ID FEP Tube - Used as outlet tube for L2250138 and inlet tube for L2250135.
Sipper Cell and Pump Accessory
L2250135
Sipper Cell and Pump Accessory for the LS-55 – Includes 1.5 mm square section, 25
L volume synthetic fused silica flow cell (L2251223) and computer controlled
peristaltic pump. Fitted with 0.7 mm FEP inlet tube (L2151203) and 1.0 mm FEP
outlet tube (L2151204). Uses pump tubing 04974155. For LS-45 requires accessory
PCB kit (L2250162). Requires, but does not include, installation by a PerkinElmer
Service Engineer (N0207173).
L2151203
0.7 mm ID FEP Tube - Used as outlet tube for L2250138 and inlet tube for L2250135.
L2151204
1.0 mm ID FEP Tube - Used as outlet tube to L2250135
N0207173
Service Installation for Sipper Accessory
Low-temperature Accessory
L2250136
Low-temperature Accessory - For measuring fluorescence or phosphorescence at
liquid nitrogen temperature. Includes a pack of five sample tubes (52126027).
This accessory is not compatible with the LS-45
52126027
Low-temperature Sample Tubes - For Low-Temperature accessory. Pack of five.
Remote Fiber Optic Accessory
L2250144
FLR-PDL9
Remote Fiber Optic Accessory – Allows you to take the measurement at the sample
rather than taking the sample to the instrument. Includes bifurcated synthetic fused
silica fiber optics (1 meter long, 280 to 800 nm range) and optical mount to
spectrometer.
Product Description List is subject to change without notice.
February 2009
6
Fluorescence Liquid Autosampler
L2250156
Fluorescence Liquid Autosampler – Allows user to make unattended measurements
of liquid samples. Includes S10 liquid autosampler (N2020010), autosampler software
(L225B004) and a semi-micro flow-through cell (B0631133).
09410077
USB to RS232 Adapter
Provides additional RS232 port utilizing a USB port on the PC
B3140617
S10 / AS-93Plus Autosampler Sample Tray
Sample tray with 90 locations (13mm diameter) for 6ml or 8ml sample
tubes.
B3140618
S10 / AS-93Plus Autosampler Sample Tray
Sample tray with 60 locations (16mm diameter) for 15ml sample tubes.
B3140621
S10 / AS-93Plus Autosampler Sample Tray
Sample tray with 21 locations (30mm diameter) for 50ml sample tubes
location for a wash tube.
and 1
B3001647
S10 / AS-93Plus Autosampler Sample Tray
Sample tray with 29 sample locations (16mm diameter) for 15ml sample
Tubes, 9 locations (30mm diameter) for 50ml sample tubes and 1 location for a
wash tube.
B0193235
Sample Tube, 6mL, Package of 500.
Polypropylene with screw cap.
B0508901
Sample Tube, 8mL, Package of 1000.
Polypropylene without screw cap.
B0193233
Sample Tube, 15 mL. Package of 500.
Polypropylene with screw cap.
B0193234
Sample Tube, 50mL. Package of 500.
Polypropylene with screw cap.
Polarization
The LS-45 is NOT suitable for polarization measurements
With the LS-55, polarizations measurements can be performed with two different system
configurations. The first configuration takes a measurement every 10 sec and is included as standard
with the LS-55. The second configuration takes a measurement every 40 msec. and requires
modification of the LS-55 for fast filters
The LS-55 fast filter configuration consists of 1 x N1870195 Fast Filter Accessory Kit, 1 x Fast Filter
Accessory Drive Unit, 1 x L2250030 Polarization Filter Kit plus installation.
N1870195
FLR-PDL9
Fast Filter Accessory Kit – Includes the Fast Filter Accessory Board and Software
(L2250019) and one drive unit (L2250146). Requires, but does not include
Polarization Filter Kit (L2250030) and the Fast Filter Accessory Drive Unit
(L2250146). Requires, but does not include installation by a PerkinElmer Service
Engineer (N0207177)
Please note that the polarizer drive must be removed from the LS-55 to
accommodate this accessory (the L2250030 polarizer elements can be mounted
in two drive units)
Product Description List is subject to change without notice.
February 2009
7
L2250146
Additional Fast Filter Accessory Drive Unit - Required for updating N1871095 to allow
polarization or both excitation and emission filters to be used. Requires filter set.
Requires, but does not include installation by a PerkinElmer Service Engineer
(N0207173).
L2250030
Fast Filter Polarization Filter Kit - Consists of two (2) pairs of polarizing filters each
set at 0 and 90 degrees to the vertical. Enables polarization values to be measured
every 40 msec. Requires two (2) drive units (L2250146). Installation by a
PerkinElmer Service Engineer is included unless a drive unit is required.
N0207177
Service Installation for the Fast Filter Accessory Kit (N1870195).
N0207173
Service Installation for the Fast Filter Accessory Drive Unit(s) (L2250146) or
Excitation and emission polarizers (L2250100)
Software Upgrades and Add-On Software Applications
L2258000
FL WinLab Version 4.00.02 Software – For registered users of earlier versions of FL WinLab
Windows based software controls the instrument, sampling accessories and data collection.
The software provides specific applications such as Scan, Time Drive, Ratio Data Collection,
ICBC Calibration, Well Plate Reader and 3D view. Included in LS50B computer-ready, PC
systems and specified update kits. Includes Software User´s Guide.
L225B004
Auto Sampler (ASP) Application takes luminescence intensity, polarization, or
anisotropy values from samples acquired with the Perkin-Elmer AS93 plus or S10
autosampler accessory.
All data acquisition, autosampler and sipper (if fitted) accessory control is coordinated
by the application. Application methods specify autosampler vial set and order of
sampling, pump control options including return of precious samples to vial after
measurement and rinsing between samples. The results are stored in TAB-delimited
text format convenient for third-party post-run processing software (e.g.
spreadsheets). Concentration data may be entered for any standard samples for later
calculation of concentrations for unknowns by third-party software
L225B005
Short Phosphorescence Decay Routine for collecting decay data and calculating
single or dual exponential lifetimes.
L225B009
TempScan software for use with the L2250150 PTP-1 Accessory only. Allows
excitation, emission or synchronous scans to be collected at regular temperature
increments. Data produced are single scans as well as a 3d data set which allows a
curve of fluorescence intensity at a particular wavelength to be plotted against
temperature. For highest accuracy, the external sample temperature probe accessory
(L2250147) is recommended.
FLR-PDL9
Product Description List is subject to change without notice.
February 2009
8
Intracellular Ion Measurements
Intracellular lon Filter Guide
Filter/Dye
nm/nm Mono.
Ion
FURA-2
340/380 Excitation
Ca++
Or
340/365 Excitation
Ca++ with IBP
Mag-FURA-2
340/380 Excitation
Mg++
BCECF
495/440 Excitation
pH
SNAFL-2
514/550 Excitation
pH
INDO-1
405/480 Emission
Ca++
SNARF-1
580/640 Emission
pH
If using 2 filter sets which use the same monochromator, for example FURA2 and BCECF, only one (1)
drive unit (L2250146) is required. Both dyes can be monitored simultaneously.
If using 2 filter sets which use different monochromators, for example BCECF and INDO-1, two (2)
drive units are necessary - one for excitation and one for emission. The 2 dyes cannot be measured
simultaneously.
Intracellular Ion Accessory
N1870195
Fast Filter Accessory Kit – Includes the Fast Filter Accessory Board and Software
(L2250019) and one drive unit (L2250146). Requires, but does not include a filter set
(see below). Requires, but does not include installation by a PerkinElmer Service
Engineer (N0207177)
This accessory is NOT suitable for the LS-45
N0207177
Service Installation for the Fast Filter Accessory Kit.
L2250146
Fast Filter Accessory Drive Unit – Second drive unit, Requires Fast Filter Accessory
Kit (N1871095) to allow both excitation and emission filters to be used. Requires filter
set. Requires, but does not include installation by a PerkinElmer Service Engineer
(N0207173).
N0207173
Service Installation for the Fast Filter Accessory Drive Unit(s)
Intracellular Ion Filter Sets
L2250021
Filter Set - FURA 2 (Excitation)
L2250022
Filter Set – BCECF (Excitation)
L2250023
Filter Set - SNAFL-2 (Emission)
L2250024
Filter Set - INDO-1 (Emission)
L2250025
Filter Set – SNARF-1 (Emission)
FLR-PDL9
Product Description List is subject to change without notice.
February 2009
9
Cells for Fluorimetry
B0631104
Rectangular Cell, OS, 10 x 10 mm, PTFE Lid - 10 x 10 mm pathlength, Special
Optical Glass, 3.5 mL cell volume. Set of 2.
B0631107
Rectangular Cell, QS, 10 x 10 mm, PTFE Lid - 10 x 10 mm pathlength. In Far UV
synthetic fused silica, Quartz SUPRASIL, 3.5 mL cell volume. Set of 2.
B0631110
Rectangular Cell, OS, 10 x 10 mm, with PTFE Stopper - 10 x 10 mm pathlength,
Special Optical Glass, 3.5 mL cell volume. Set of 2.
B0631113
Rectangular Cell, QS, 10 x 10 mm, with PTFE Stopper -10 x 10 mm pathlength,
Quartz SUPRASIL, 3.5 mL cell volume. Set of 2.
B0631124
Ultra-Micro Cell, QS, 10 x 2 mm, with PTFE Stopper - 10 x 2 mm pathlength, Quartz
SUPRASIL, Chamber volume 100 µL. Fill volume 120 L.
B0631123
Micro Cell, QS, 5 x 5 mm, without Lid - 5 x 5 mm pathlength, Quartz SUPRASIL,
600 µL cell volume. Set of 2. Requires micro cell adapter (L2250139).
B0631142
Micro Cell, QS, 5 x 5 mm, with PTFE Stopper NS 5 - 5 x 5 mm pathlength, Quartz
SUPRASIL, with PTFE Stopper NS 5, 850 L cell volume. Set of 2. Requires
micro cell adapter (L2250139).
L2250139
Micro Cell Adapter - Adapter allows 5 mm pathlength micro cells to be used in any of
the cell holders. Package of 4.
B0631132
Semi-Micro Cell, magnetically stirred, QS, 4 x 4 mm - 4 x 4 mm pathlength, Quartz
SUPRASIL. Used in any stirred cellholder, 500 µL cell volume, requires stirrer fleas,
(04978499).
L2250008
Coverslip Holder Accessory – Designed for 10 mm round coverslips with thickness of
0.155 to 0.185 mm. Package of 4. Requires (but does not include) a 10 mm
pathlength cell with lid (not stopper).
B0631125
Semi-Micro Cell, QS – 10 x 4 mm, with PTFE Stopper, Temperature Controlled. 10 x
4 mm pathlength, Quartz SUPRASIL, with PTFE Stopper, 1.4 mL cell volume.
Horizontal inlet/outlet tubes for thermostatting.
B0631133
Semi-Micro Flow-Through Cell, QS, - 3 x 3 mm, Screw fitting Inlet/Outlet Tubes
3 x 3 mm pathlength, Quartz SUPRASIL, 100 µL cell volume. Compact with
2 screw connectors and FEP tubing.
Reference Materials and Test Samples
52019600
Luminescence Sample Blocks –Set of six, including Europium for testing
phosphorescence
1 = Anthracene + Naphtalene (360+290/402+330 nm),
2 = Ovalene (342/482 nm),
3 = p-Terphenyl (295/338 nm),
4 = Tetraphenyl-butadien (348/422 nm),
5 = Europium (Phosphorescence, 335/613 nm)
6 = Rhodamin B (562/573 nm)
52124965
Phosphorescence Sample Block Included in 52019600.
L2251293
Sealed water cuvette - Sealed 10 mm pathlength cell containing high purity water for
Raman band measurements.
CP364460
Ovalene sample block. Part of the 52019600 set.
FLR-PDL9
Product Description List is subject to change without notice.
February 2009
10
Sources, Detectors, Attenuators, Filters and Septa
L2251157
Replacement Pulsed Xenon Source for LS-45 and LS-55 (can also be used with the
LS30, LS40, LC240 and LS50/50B instruments)
04969486
Replacement Festoon bulb for LS-45 and LS-55 (can also be used with the LS30,
LS40, LC240 and LS50/50B instruments)
52124966
R928 Red-sensitive sample Photomultiplier (PMT) – For measurements up to 900
nm.
L6020281
R955 Red-sensitive sample Photomultiplier (PMT) - For measurements up to 900
nm. This PMT offers better performance in the UV (200-250 nm) than the R928
C6850012
Diffuser plate - For carrying out emission correction between 200nm and 350nm.
52126319
Attenuator, 1%Transmission 50mm square.– Included with LS-45;
52126320
Attenuator, 2%Transmission 50mm square.
52123926
Attenuator 8% Transmission 50mm square
52123887
Attenuator 33% Transmission 50mm square
02639507
Manual Cut-Off Filter 290nm, 5x5cm – Wavelength filter Included in LS-55 filter
wheel
02639508
Manual Cut-Off Filter 310nm, 5x5cm
02639505
Manual Cut-Off Filter 350nm, 5x5cm - Wavelength filter Included in LS-55 filter wheel
02639509
Manual Cut-Off Filter 390nm, 5x5cm - Wavelength filter Included in LS-55 filter wheel
L2151164
Manual Cut-Off Filter 530nm, 5x5cm
L2251286
Septum Injector Body – Included with LS-55
L2251287
Septum Injector Cap .– Included with LS-55
04961071
Spare septa - For standard septum injector and Luminometer accessory L2250037.
Package of 3.
Recommended Minimum Computer Configuration
Minimum processor speed
Intel Core 2 Duo
Minimum RAM
1.0 GB (2 x 512MB)
Minimum hard disk space
160 GB
Screen resolution
1024 x 768 SVGA
CD ROM / Floppy disk required ?
Yes - CD-RW / No - Floppy
Communications
RS232-C
Operating systems supported
Windows XP Professional SP2
Other software required
FL WinLab 4.00.03
Please note that PerkinElmer reserves the right to supply equivalent or enhanced versions of
products resold by PerkinElmer, such as computers, in response to model changes by the
manufacturer.
FLR-PDL9
Product Description List is subject to change without notice.
February 2009