Monitoring of energy consumption provides better energy performance Energy Meters Keep track of system performance With energy meters it gets easy Proven Sonometer™ uses patented ultrasonic technology that guarantees highly accurate and reliable measurement and long-term stability We take the lead in district energy solutions Energy meters make it easy to keep track of the energy performance of any heating, district heating or cooling system. With the increased focus on energy saving and individual billing according to consumption, this system improves customer satisfaction and retention. Danfoss SONOMETER™ energy meters use patented ultrasonic technology that guarantees highly accurate and reliable measurement and long-term stability. Core features of SONOMETER™: The SONOMETER™ 1100 is an ultrasonic static compact energy meter especially designed for heating, cooling or combined heating/cooling applications in local and district energy systems. The robust and dirt-resistant design makes it very service friendly. The meters ensure low cost of ownership in all areas. Unlimited system capability makes SONOMETER™ the perfect meter for smart metering. Data transmission by wire or radio provides simple energy data management. No hardware changes or reconfiguration are necessary for adapting to different system engineering. Core features of SONOMETER™: • MID (EN 1434) class 2 approval Leading energy efficiency worldwide • Improved radio performance District energy is an extremely efficient, low-cost, low-maintenance system for heating residential, commercial and industrial buildings. Its greatest attribute, however, is that it also provides effective solutions to help address global concerns in regard to fuel shortages, rising fuel costs and the growing impact of our energy demand on the environment. Danfoss District Energy is the leading supplier of products, systems and services for district heating and cooling (DHC), the optimum technology for urban areas, where renewable or waste energy can be converted into usable energy and distributed for heating of buildings and houses • Dedicated district heating application telegram Planning for success • Remote reading via M-Bus, L-Bus, RS 232, RS 485, Radio or optical interface • Integrated Radio 868 MHz with Open Metering Standard (OMS) • Individual remote reading (Automatic Meter Reading) with add-on modules Plug&Play • 2 communication ports (e.g. M-Bus + M-Bus) At Danfoss, we are commited to finding the right solution for district heating and cooling systems for all our customers - whatever the size, needs or requirements. As the leading total supplier to the DHC market, Danfoss District Energy provides customers worldwide a complete range of automatic controls, heat exchangers, domestic hot water systems and substations, which are applied throughout the process of generating, distributing and controlling heat to homes and buildings. The lastest generation of DIstrict Energy infrastructure enables city planners to vastly improve energy efficiency while creating a viable channel for accessing renewable sources. Safe, sustainable, scalable - District Energy is an essential component in achieving real carbon savings today. The products contribute to individual comfort, reduce energy consumption as well as providing reliable and lasting operations and guarantee minimum servicing. Dedicated to district heating and cooling Since 2003 Danfoss District Energy has strengthened its position by acquiring several leading and high performing manufacturers of substations, DHW systems and heat exchangers worldwide. Our 360 degree, fully-integrated business approach is the result of more than 30 years of specialisation within the district heating market. Doing business with Danfoss means gaining access to industry leading: • • • • • Product portfolio for district heating and cooling Consultancy and customer dedication Innovation, technical optimisation and performance Safety and reliability in cooperation Global reach with strong local representation and know-how Components: • Ultrasonic flow sensor • Calculator with integral hardware and software for measuring flow rate, temperature and energy consumption • Pair of temperature sensors Danfoss Ltd Ampthill Road, Bedford, MK42 9ER Tel: 01234 364621 Fax: 01234 219705 Email: [email protected] Website: www.heating.danfoss.co.uk Danfoss can accept no responsibility for possible errors in catalogues, brochures, and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. Part No: 157v01 12/15 www.heating.danfoss.co.uk Sonometer™ 1100 Energy Meters The SONOMETER™1100 is an ultrasonic static compact energy meter especially designed for heating, cooling or combined heating/ cooling application in local and district energy systems. Sonometer™ 500 District Heating or Community Heating Plant Substation House The SONOMETER™1100 as a compact energy meter consists of the following components: - Ultrasonic flow sensor - Calculator with integral hardware and software for measuring flow rate, temperature and energy consumption - Pair of temperature sensors Sono 3500 Sono 1100 Sono 500 The SONOMETER™500 is an ultrasonic static compact energy meter designed for heating applications in buildings, especially residential submetering (e.g. in heat interface units). The SONOMETER™500 as a compact energy meter consists of the following components: - Ultrasonic flow sensor - Calculator for measuring energy consumption, flow rate and temperatures Apartment Building Energy Meter Sizing Chart This regulation requires all those who supply and charge tenants for heating or cooling through a district heat network or communal heating system to implement metering and billing across the network. The regulations apply whether users pay for heat directly or as part of their rent or service charge. Typically, energy consumption in heat networks will be measured using an individual energy meter per final customer. In addition to the main objective of reducing CO2 emissions from UK buildings, the regulations will give consumers more control of their energy costs, set minimum standards for billing of users in heat networks, and promote better heat network management and efficiency. • 1st. approval in Europe for ultrasonic energy meter with dynamic range of qi/qp 1 : 250 in class 2 (qp 1.5 / 2.5 / 6 / 10 / 15 / 25 / 40 / 60 m³/h) • Complete dynamic range: ≥ 1 : 1500 • Lithium battery, 230 V AC or 24 V AC mains unit • Battery lifetime 11 years (16 years optional) • Unique free- beam principle - Pair of temperature sensors - M-Bus interface on board Features Features Flow Rate l/h (Litres per hour = litres per second x 3600) The energy performance of any heating, district heating and cooling system matters, even more so now that The Heat Network Regulations 2014 have been introduced into UK law. Commercial Office Building Sono 3500 CT • MID approval for ultrasonic meter with dynamic range of qi : qp 1 : 100 • M-bus communication as standard • Nominal flow range 0.6, 1.5 and 2.5 m3/h The SONO3500CT is an ultrasonic flow meter especially designed for heating, cooling or combined heating/cooling application in local and district energy systems. In combination with INFOCAL 8 it becomes an energy meter for heating or cooling. • Temperature range 15 – 90°C • Unique free - beam principle • Accuracy class 2 according to EN 1434 The SONO3500CT has been approved according to MID class 2. The approved flow meter consists of a flow sensor pipe, 4 transducers with cables and a transmitter with LCD display. • High long term stability, tested and verified at independent AGFW test • Can be configured for heating, cooling or combined heating/ cooling application Features • Battery supply with 10 years lifetime Danfoss offer a solution to suit almost every application from a domestic flat station, to a large network: • Temperature range: 5 - 130 / 150 °C • Ultrasonic 2-path flow sensor secures measurement and optimum accuracy • Communal heating and centralised boiler systems, where dwellings are supplied with heat and hot water from a central boiler. • Swirl-free flow around reflector • Improved service-friendly energy meter design • Housings with thread and flange (PN 16 / 25) • Overload temperature up to 150 °C (qp= 0.6 - 2.5 m3/h) • Lower pressure loss • District heat networks, where a central source supplies heat to mixed commercial and residential customers. • Shared offices, where energy from boilers/chillers supply rented office space. • University halls of residence, sheltered and social housing and care homes, where the user is charged for energy provided by the building owner. Meter QP Nominal Flow and Size DN Sizing Method: • Take the design maximum flow rate required for the meter • Ensure it is in litres per hour (l/h = l/s x 3600, l/h = m3/h x 1000) • Find your flow rate on the chart above • Select the smallest meter to meet the required design flow rate • Galvanically isolated digital output for easy connection to energy calculator INFOCAL 8 • Robust stainless steel reflector • 115 / 230 V mains-powered with back-up battery as standard version in case of mains power failure • Insensitive to dirt • Optional battery-powered version (up to 6 years lifetime) • Available in nominal sizes qp 0.6 / 1.5 / 2.5 / 3.5 / 6 / 10 / 15 / 25 / 40 / 60 m³/h • Fast measuring frequency 15 Hz / 0.5 Hz (230 V AC / Battery) • Approved according to MID in class 2 and 3, and PTB K 7.2 for cooling • No calming sections necessary in the inlet and/or outlet (standard installation) • Compact (standard) or remote mounting • No pressure drop • Long-term stability • Easy one-button straight forward display • Extensive readable data memory • Low pressure loss • Insensitive against dirt • Swirl - free flow around reflector • Robust stainless steel reflector
© Copyright 2026 Paperzz