Vertical Round Accent

JOB NAME
MB3G2
Vertical Round Accent
CATALOG NUMBER
NOTES
TYPE
1
7 15/16”
10 1/2”
4 7/8”
6 3/8”
8”
Horizontal Adjustability: 358° / Vertical Adjustability: 258° Total
Order Matrix | Example: MB3G2L335B-30
A
B
A
C
Catalog Number
MB3G2 Vertical Accent
B
L1
L2
L3
C
27
279
30
309
35
41
D
blank
-DIM
Wattage
24W
34W
45W
CCT / CRI
2700K / 82 CRI
2700K / 92 CRI
3000K / 82 CRI
3000K / 92 CRI
3500K / 82 CRI
4100K / 82 CRI
D
E
F
E
Finish
W
B
SV
White
Black
Silver
F
Optic
-17
-30
-55
G
blank
-PS
-PS-27
-J
-L
G
Catalog Number
System Wattage *
Delivered Lumens **
MB3G2L1
MB3G2L2
MB3G2L3
24W
34W
45W
2500lm @ 3000K
3200lm @ 3000K
3900lm @ 3000K
* System wattage include driver and LED module consumption.
**Delivered lumen output will vary depending on CCT, CRI and optic selection.
17° Spot
30° Narrow Flood
55° Wide Flood
LED LIGHT ENGINE
--2700K, 3000K, 3500K and 4100K 82 CRI
--2700K and 3000K 92 CRI (R9 Value = 59)
--3 Step MacAdam (3 SDCM)
--LED mounted to die-cast / extruded aluminum heat sink
--50,000 hours average rated life at 70% output
OPTICS
--17° Spot, 30° Narrow Flood, and 55° Wide Flood
Adapter
Intense Single / Two Circuit 120V
Pro-Series 120V
Pro-Series 277V 2
J-Type Adapter 120V 3
L-Type Adapter 120V 3
Driver
Non-Dimming
ELV Dimming 2
ELECTRICAL SYSTEM
--120V-277V 50/60Hz input
--Class 2 power supply
--Over voltage, over current and short circuit protection: Auto recovery
--MTBF > 100,000 hours
--This product complies with IEEE C62.41 for surge endurance up to 2.5KV. Additional
surge protection recommended. Damage from power surge is not covered by warranty.
Notes:
1. Energy Star (82 CRI - 3000K, 3500K, 4100K only)
2. Dimming available in 120V only.
3. J -Type & L-Type adapters are for single circuit, consult factory for two circuit.
DIMMING
Must specify -DIM for ELV Dimming
--(ELV) reverse phase control dimmers. 120V only.
--Dimmable 100 - 10%
Accessories
Track luminaire will accommodate a maximum of (2) filter media. Accessory holder required.
TRACK COMPATIBILITY
Track luminaire is designed for use with the following track systems:
--Single Circuit/Single Neutral 120V
--Two Circuit/Single Neutral 120V
--Pro-Series Two Circuit / Two Neutral 120V
--Pro-Series Two Circuit / Two Neutral 277V
--J-Type & L-Type Adapter are for Single Circuit (Consult factory for Two Circuit)
Accessory Holder
LH1
LH1W
Accessory Holder, Black
Accessory Holder, White
Filter Media
PFL98-1
PFL98-2
PFL98-3
PFL98-4
PFL98-L
Prismatic Spread
Linear Spread
Sand Blast Spread
Soft Focus
Louver
LISTING/WARRANTY
--ETL Listed to US and Canadian standards for dry locations
--10-Year Intense LED Limited Warranty
-- ENERGY STAR® Qualified
TRACK L/M-031:16 P-31
Intense Lighting, LLC | 3340 E La Palma Ave, Anaheim, CA 92806 | Phone: 714 630-9877 | Fax: 714 630-9883
Note: Specifications and dimensions subject to change without notice. Visit us at www.intenselighting.com for the most up to date specification and photometric information.
JOB NAME
CATALOG NUMBER
NOTES
MB3G2L130
17° Spot (-17)
30° Narrow Flood (-30)
Report #: L111402101 (-17)
TYPE
L101408201 (-30)
L101408202 (-55)
80°
70°
2913
80°
70°
1738
60°
5826
50
8739
10°
20°
80°
70°
806
60°
3476
°
50
5218
40°
11652
55° Wide Flood (-55)
10°
20°
50°
2419
40°
6951
30°
60°
1612
°
40°
3225
30°
10°
20°
30°
Watts: 26.5
Lumens: 2045.69
LPW: 77.2
Watts: 24.25
Lumens: 2511.9
LPW: 103.58
Watts: 22.5
Lumens: 2412.63
LPW: 107.23
Candelas at Nadir
Candelas at Nadir
Candelas at Nadir
Degree Candela
Degree Candela
Degree Candela
0°
5°
15°
25°
35°
45°
0°
5°
15°
25°
35°
45°
0°
5°
15°
25°
35°
45°
11652.4
8851.58
2295.75
887.43
220.02
69.25
6890
6922.5
3555.5
1292.74
290.26
67.28
D
D
2655.72
2705.61
3200.23
2244.02
276.91
5.42
C
C
D
D
45o
30o
30o
APPLICATION DATA:
W and L are the outer points where
the candle power drops to 50% of
maximum. FC are the initial foot
candles at the center of the beam.
W
L
C
D
FC
L
L
Illuminated width
& length
are based upon point at which
illuminance
falls to 50% of center illuminance. Recommended spacing is based
W
L
FC
FC
W
W illuminated plane.
upon uniform illuminanceL aiming angle is the angle between
the lamp
W axis and the perpendicular to the
C
DD
DD
D
CC
DD
Beam width
Beam length
Distance to center of beam
Distance
Foot candles
DD
D
D
3030
oo
WW
WFCFC
LL
LL
CC
FC
L
0° HORIZONTAL
D
FC
W
3030o o
30
LFCFC
C
LL
FC
WW
WW
W
30° HORIZONTAL
L
D
C
FC
W
D
C
FC
C
LL
L
L
WW
W
DD
30° VERTICAL
L
D
CC
o
45o 60
4545o o
30o
o
D
C
W
L
D 6060o o
W
C
L
W
D
60° VERTICAL
C
CC
C60o
FC
LL
W
L
L
MB3G2L130-17
17° Spot
5.0’
7.5’
10’
12.5’
466
207
117
74.6
1.45
2.17
2.9
3.62
1.45
2.17
2.9
3.62
5.0’
7.5’
10’
12.5’
2.75
4.25
5.5
7
306
135
76.5
48.9
1.87
2.81
3.71
4.64
1.63
2.44
3.23
4.05
3.0’
4.0’
5.0’
6.0’
4.5
6
7.5
9
189
106
67.9
47.1
1.59
2.11
2.32
3.17
3.03
4.04
4.38
6.08
3.0’
4.0’
5.0’
6.0’
1.75 831 0.98
2.25 WW477 W 1.31
2.75 306 1.63
3.25 212
1.94
1.15
1.49
1.87
2.24
MB3G2L130-30
30° Narrow Flood
5.0’
7.5’
10’
12.5’
276
122
68.9
44.1
2.71
4.06
5.42
6.77
2.71
4.06
5.42
6.77
5.0’
7.5’
10’
12.5’
2.25
3.25
4.25
5.5
207
92.7
52.2
33.3
3.09
4.59
6.12
7.67
2.72
4.06
5.41
6.77
3.0’
4.0’
5.0’
6.0’
3.75
5
6.25
7.5
169
94.9
60.7
42.2
2.26
3.02
3.77
4.53
3.33
4.44
5.57
6.68
3.0’
4.0’
5.0’
6.0’
1.25
1.75
2.25
2.5
576
325
207
144
1.64
2.18
2.73
3.26
1.86
2.47
3.09
3.7
MB3G2L130-55
55° Wide Flood
5.0’
7.5’
10’
12.5’
106
47.2
26.6
17
4.37
6.55
8.74
10.9
4.37
6.55
8.74
10.9
5.0’
7.5’
10’
12.5’
1
1.5
1.75
2.25
119
52.8
29.8
19
3.74
5.63
7.48
9.21
4.74
7.13
9.49
11.9
3.0’
4.0’
5.0’
6.0’
2.5
3.25
4
4.75
155
87.7
56.1
39
3.13
4.12
5.18
6.22
2.12
2.81
3.52
4.21
3.0’
4.0’
5.0’
6.0’
0.5
0.75
1
1.25
325
186
119
82.5
2.84
3.76
4.72
5.69
2.32
2.96
3.67
4.4
TRACK L/M-031:16 P-32
Intense Lighting, LLC | 3340 E La Palma Ave, Anaheim, CA 92806 | Phone: 714 630-9877 | Fax: 714 630-9883
Note: Specifications and dimensions subject to change without notice. Visit us at www.intenselighting.com for the most up to date specification and photometric information.
JOB NAME
CATALOG NUMBER
NOTES
MB3G2L230
17° Spot (-17)
30° Narrow Flood (-30)
Report #: L111402101 (-17)
TYPE
L101408201 (-30)
L101408202 (-55)
80°
70°
3581
80°
70°
1863
60°
7162
50
10743
10°
20°
80°
70°
1084
60°
3727
°
50
5590
40°
14324
55° Wide Flood (-55)
10°
20°
50°
3252
40°
7454
30°
60°
2168
°
40°
4336
30°
10°
20°
30°
Watts: 34
Lumens: 2514.8
LPW: 73.96
Watts: 34.25
Lumens: 2693.53
LPW: 78.64
Watts: 32.1
Lumens: 3227.21
LPW: 100.54
Candelas at Nadir
Candelas at Nadir
Candelas at Nadir
Degree Candela
Degree Candela
Degree Candela
0°
5°
15°
25°
35°
45°
0°
5°
15°
25°
35°
45°
0°
5°
15°
25°
35°
45°
14324.5
10881.4
2822.2
1090.94
270.48
82.12
7388.2
7423.05
3812.59
1386.22
311.25
72.14
D
D
3551.58
3599.47
4249.39
2983.08
383.05
5.81
C
C
D
D
45o
30o
30o
APPLICATION DATA:
W and L are the outer points where
the candle power drops to 50% of
maximum. FC are the initial foot
candles at the center of the beam.
W
L
C
D
FC
L
L
Illuminated width
& length
are based upon point at which
illuminance
falls to 50% of center illuminance. Recommended spacing is based
W
L
FC
FC
W
W illuminated plane.
upon uniform illuminanceL aiming angle is the angle between
the lamp
W axis and the perpendicular to the
C
DD
DD
D
CC
DD
Beam width
Beam length
Distance to center of beam
Distance
Foot candles
DD
D
D
3030
oo
WW
WFCFC
LL
LL
CC
FC
L
0° HORIZONTAL
D
FC
W
3030o o
30
LFCFC
C
LL
FC
WW
WW
W
30° HORIZONTAL
L
D
C
FC
W
D
C
FC
C
LL
L
L
WW
W
DD
30° VERTICAL
L
D
CC
o
45o 60
4545o o
30o
o
D
C
W
L
D 6060o o
W
C
L
W
D
60° VERTICAL
C
CC
C60o
FC
LL
W
L
L
MB3G2L230-17
17° Spot
5.0’
7.5’
10’
12.5’
573
255
143
91.7
1.45
2.17
2.9
3.62
1.45
2.17
2.9
3.62
5.0’
7.5’
10’
12.5’
2.75
4.25
5.5
7
376
166
94
60.1
1.87
2.81
3.71
4.64
1.63
2.44
3.23
4.05
3.0’
4.0’
5.0’
6.0’
4.5
6
7.5
9
232
130
83.4
57.9
1.58
2.12
2.64
3.17
3.03
4.05
5.06
6.08
3.0’
4.0’
5.0’
6.0’
1.75 1021
2.25 WW587 W
2.75 376
3.25 260
0.98
1.31
1.63
1.95
1.15
1.49
1.87
2.24
MB3G2L230-30
30° Narrow Flood
5.0’
7.5’
10’
12.5’
295
131
73.9
47.3
2.71
4.06
5.42
6.77
2.71
4.06
5.42
6.77
5.0’
7.5’
10’
12.5’
2.25
3.25
4.25
5.5
222
99.4
56
35.7
3.09
4.6
6.11
7.68
2.72
4.06
5.41
6.77
3.0’
4.0’
5.0’
6.0’
3.75
5
6.25
7.5
181
102
65.1
45.2
2.26
3.01
3.77
4.52
3.34
4.44
5.56
6.68
3.0’
4.0’
5.0’
6.0’
1.25
1.75
2.25
2.5
618
349
222
154
1.64
2.17
2.72
3.27
1.85
2.47
3.09
3.71
MB3G2L230-55
55° Wide Flood
5.0’
7.5’
10’
12.5’
142
63.2
35.5
22.7
5.28
7.93
10.6
13.2
5.28
7.93
10.6
13.2
5.0’
7.5’
10’
12.5’
1
1.5
1.75
2.25
160
71.1
40.1
25.7
3.74
5.67
7.46
9.31
4.72
7.08
9.45
11.8
3.0’
4.0’
5.0’
6.0’
2.5
3.25
4
4.75
207
117
74.6
51.9
3.09
4.1
5.18
6.2
2.13
2.83
3.55
4.24
3.0’
4.0’
5.0’
6.0’
0.5
0.75
1
1.25
432
247
158
110
2.85
3.77
4.72
5.68
2.35
3.02
3.71
4.41
TRACK L/M-031:16 P-33
Intense Lighting, LLC | 3340 E La Palma Ave, Anaheim, CA 92806 | Phone: 714 630-9877 | Fax: 714 630-9883
Note: Specifications and dimensions subject to change without notice. Visit us at www.intenselighting.com for the most up to date specification and photometric information.
JOB NAME
CATALOG NUMBER
NOTES
MB3G2L330
17° Spot (-17)
30° Narrow Flood (-30)
Report #: L111402101 (-17)
TYPE
L101408201 (-30)
L101408202 (-55)
80°
70°
4228
80°
70°
2674
60°
8456
50
12684
10°
20°
80°
70°
1241
60°
5347
°
50
8021
40°
16912
55° Wide Flood (-55)
10°
20°
50°
3724
40°
10694
30°
60°
2433
°
40°
4966
30°
10°
20°
30°
Watts: 44.61
Lumens: 2969.06
LPW: 66.56
Watts: 40.25
Lumens: 3863.65
LPW: 95.99
Watts: 39.4
Lumens: 3689.99
LPW: 93.65
Candelas at Nadir
Candelas at Nadir
Candelas at Nadir
Degree Candela
Degree Candela
Degree Candela
0°
5°
15°
25°
35°
45°
0°
5°
15°
25°
35°
45°
0°
5°
15°
25°
35°
45°
16912
12847
3332
1288
319
101
10600
10650
5470
1989
447
104
D
D
4039.18
4217.3
4932.61
3143.31
299.95
0
C
C
D
D
45o
30o
30o
APPLICATION DATA:
W and L are the outer points where
the candle power drops to 50% of
maximum. FC are the initial foot
candles at the center of the beam.
W
L
C
D
FC
L
L
Illuminated width
& length
are based upon point at which
illuminance
falls to 50% of center illuminance. Recommended spacing is based
W
L
FC
FC
W
W illuminated plane.
upon uniform illuminanceL aiming angle is the angle between
the lamp
W axis and the perpendicular to the
C
DD
DD
D
CC
DD
Beam width
Beam length
Distance to center of beam
Distance
Foot candles
DD
D
D
3030
oo
WW
WFCFC
LL
LL
CC
FC
L
0° HORIZONTAL
D
FC
W
3030o o
30
LFCFC
C
LL
FC
WW
WW
W
30° HORIZONTAL
L
D
C
FC
W
D
C
FC
C
LL
L
L
WW
W
DD
30° VERTICAL
L
D
CC
o
45o 60
4545o o
30o
o
D
C
W
L
D 6060o o
W
C
L
W
D
60° VERTICAL
C
CC
C60o
FC
LL
W
L
L
MB3G2L330-17
17° Spot
5.0’
7.5’
10’
12.5’
676
301
169
108
1.5
2.17
2.9
3.62
1.5
2.17
2.9
3.62
5.0’
7.5’
10’
12.5’
2.75
4.25
5.5
7
444
197
111
71
1.87
2.79
3.72
4.64
1.63
2.43
3.23
4.05
3.0’
4.0’
5.0’
6.0’
4.5
6
7.5
9
274
154
98.5
68.4
1.59
2.12
2.64
3.16
3.03
4.04
5.06
6.07
3.0’
4.0’
5.0’
6.0’
1.75 1206
2.25 WW693 W
2.75 444
3.25 307
0.98
1.31
1.63
1.95
1.15
1.49
1.87
2.24
MB3G2L330-30
30° Narrow Flood
5.0’
7.5’
10’
12.5’
424
188
106
67.8
2.58
3.86
5.14
6.42
2.58
3.86
5.14
6.42
5.0’
7.5’
10’
12.5’
2.25
3.25
4.25
5.5
319
143
80.4
51.2
3.09
4.59
6.11
7.67
2.72
4.05
5.41
6.77
3.0’
4.0’
5.0’
6.0’
3.75
5
6.25
7.5
260
146
93.5
64.9
2.26
3.01
3.77
4.52
3.33
4.44
5.56
6.68
3.0’
4.0’
5.0’
6.0’
1.25
1.75
2.25
2.5
886
501
319
222
1.64
2.17
2.72
3.26
1.86
2.47
3.09
3.69
MB3G2L330-55
55° Wide Flood
5.0’
7.5’
10’
12.5’
162
71.8
40.4
25.9
5.27
7.91
10.5
13.2
5.27
7.91
10.5
13.2
5.0’
7.5’
10’
12.5’
1
1.5
1.75
2.25
182
80.9
45.7
29.2
3.75
5.63
7.47
9.36
4.73
7.12
9.45
11.8
3.0’
4.0’
5.0’
6.0’
2.5
3.25
4
5
233
131
83.9
58.4
3.18
4.23
5.34
6.37
2.1
2.81
3.51
4.19
3.0’
4.0’
5.0’
6.0’
0.75
0.75
1
1.25
498
281
180
126
2.84
3.79
4.75
5.7
2.24
3
3.68
4.37
TRACK L/M-031:16 P-34
Intense Lighting, LLC | 3340 E La Palma Ave, Anaheim, CA 92806 | Phone: 714 630-9877 | Fax: 714 630-9883
Note: Specifications and dimensions subject to change without notice. Visit us at www.intenselighting.com for the most up to date specification and photometric information.