OPT. ALARM HARNESS PR 1 3-WAY VALVE LOUVERS STAGING BR R/O 3 T/W 4 Y 5 BL 6 5 P 6 P 7 BR/W 8 R 9 R/BK R/W 10 G 12 GY 10 BK/W 8 BK 6 P 4 BR/W 2 2 BL X1 1 PR 11 GY 12 W/BK 1 W X8 F4 3 W 1 Y X13 F2 7 GY R/BK BL 5 R/BK 6 BR 7 CONTROLLER F5 Y 1 BR/W 3 BL 4 PR 5 6 R/W 7 BR BK 8 Y/G 9 BL/BK GY/W 2 GY/W 1 10 O/R 4 X2 F6 R 1 MODBUS MODULE CONNECTIONS FUSE AMPS F2 = F4 = F5 = F6 = Y 3 2 X7 4 BL 1 R 2 O/BK 3 R 4 POOL SUP SENSO R O/R Y 1 P 2 5 BK 4 PR 3 PR 2 P 1 P INLET SENSOR 10K/20K G W 10K 4 3 2 BK 1 R X12 8 BK/R W 3 1 X11 X4 X9 Y 6 BR 7 24V COM OPT. MODBUS HARNESS SYSTEM PUMP RELAY COIL R 120V W P Y S3/S4 Y S1/S2 60VA Y 2 BL 3 2 Y 3 BL CKT. BREAKER PR G BR 1HP UNIT MAX PUMP BR BR BR CHASSIS GROUND W ON/OFF SWITCH GY/W 4 AC PUMP RELAY 120VAC COIL Y 4 Y 5 Y 6 BL 1 R/O 2 R/W 3 1 2 2 BK/W 4 1 O 2 O/BK R/W T W 11 P BL 8 PR 10 Y 4 Y 5 Y O/ BK R Y R R Y R 1 1 2 3 13 GY 14 T/W 12 15 R/W 3 2 1 6 5 4 TEST LWCO PROBE RESET G LWCO 24VAC 3 PR Y BL BL PR 3 2 1 6 6 CONNECTION BOARD 2 1 2 1 2 1 2 O/BK 1 O 2 1 2 O 1 O/BK O BL O/BK R 16 BR/W 1 R 120V R SILENCING SWITCH 1 DIGITAL HARNESS HI-LIMIT PR PR Y BL 2 1 C 2 NC C NO AUXILLIARY 2 3 GY ALARM RELAY 120VAC COIL ALARM BELL O 2 3 G GROUNDING OPTION JUMPER LOW VOLT HARNESS 1 R/BK Y R/BK R/O Y R/O 1 2 3 6 Y 2 3 O O/BK 1 2 R/O Y R/O 3 1 2 3 R/W Y R/W 1 2 S1 S2 S3 S3 S4 1 2 3 4 5 6 STAGE #1 STAGE #2 BURNER #1 HSI GROUND 1 GY GY 1 3 GY GY 3 5 G G 5 2 GY G G GY 3 1 BK HI HI STAGE #3 STAGE #3 R R LO LO R 2 3 W 3 G NEU GND W 4 NEU GND G 4 BK/ W BK BK 1 3 G G 3 BK/R 5 BK R BK/ W HI LO 120V G TO PWR HI/LO SPEED RELAY 120VAC COIL W 4 BK/W ! DANGER TO PREVENT ELECTRICAL SHOCK THIS HEATER MAY BE CONNECTED TO MORE THAN ONE BRANCH CIRCUIT. MORE THAN ONE DISCONNECT SWITCH MAY BE REQUIRED TO DE-ENERGIZE THE EQUIPMENT FOR SERVICING. BK BK W W 50VA 60VA 75VA 100VA FIELD OPTIONS WIRE COLOR REFERENCE BL GAS VALVE XFMR 1 BK 1 TO 2 3 W 3 XFMR W MODBUS ADAPTER FACTORY OPTIONS BL CIRCUIT BREAKER G TO CONNECTION BOARD 2 W 120V 3 BK BK/ BK/ W R MAIN UNIT HARNESS 2 G 120V W BLOWER RELAY 120VAC COIL 1 BL 2 1 4 GY/W 1 1 STAGE #4 BURNER #2 HSI GROUND GY/W BK 2 GY/W 6 GY/W 1 4 P 1 LO - GAS O BL R 2 5 P 5 4 HI-GAS O/R BL 11 W/BK T BL CHASSIS GROUND O/BK 12 T FLOW SWITCH BK R MAIN UNIT O BLOCK FLUE COM SWITCH NO AIR PROVE COM SWTICH S1 LOW GAS SWITCH STAGE #1 3 R/BK 5 BK/R 4 LOW VOLTAGE HARNESS T O/BK NC BL IGNITER W 1 2 O/BK 24V BK 2 GY/W 6 120V W/R 2 3 120V BK G BR/ W BK W 120V/60Hz NEUTRAL SUPPLY LINE GROUND 1 BK 3 W BK 1 G 2 3 W 24V W CONTROLLER XFMR 120V IND-DHW PUMP RELAY COIL R 120V 24V GROUND 13 12 O O/BK 1 2-SPD BLOWER O G BK Y FLOW SWITCH 12 BL/BK 15 14 BL Y 2 4 NOTE: NUMBER OF GAS VALVES VARIES BY MODEL BR MAIN POWER HARNESS O BL LWCO 1 BL CONSULT FACTORY DISPLAY Y BR Y/G IDENTIFICATION PLUG MODEL SPECIFIC X10 7 R/BK 4 18 X6 X5 6 W/R W/BK 2 GY 16 BK/R 5 R/O X3 T 19 17 BR/W 10 O/R T 20 12 R BOILER/POOL HEATER SAFETY OUTLET SENSOR 3 W/BK 8 CASCADE MODBUS 1 3 Notes: 1. All wiring must be installed in accordance with : local, state , provincial and national code requirements per either N.E.C. in USA or C.S.A. in Canada. 2. If any original equipment wire as supplied with the appliance must be replaced , it must be replaced with wire having same wire gauge (AWG) and rated for a minimum of 105°C 3. Actual connector block locations may vary from those shown on diagrams . Refer to actual components for proper connector block locations when using diagrams to trouble shoot unit . OPT. ALARM DIGITAL HARNESS 4 PR BL 2 Y LOW VOLT HARNESS + + + ALARM 1 + CONTACTS 2 TO MONITORING DEVICE 3 + RUNTIME + CONTACTS 4 OPEN + 3-WAY 5 + OPEN 24V CLOSE CLOSE VALVE CN4 6 + COM COMMON 7 + S1 STAGE #1 8 S1 9 + + S2 CONNECT STAGE #2 10 TO + S2 11 TERMINAL STAGE #3 12 + S3 #19 S3 13 + (LOUVER 14 + S4 STAGE #4 RELAY) + S4 15 COM FIELD CN5 16 + LOUVER PROVING PROVE + SWITCHSUPPLIED 17 + LINE WIRING LOUVER RELAY R 18 M + COIL 19 + NEU TANK 20 AQUASTAT + AQUASTAT 21 CN3 TANK SENSOR 22 + TANK + SENSOR 23 24 + SHIELD CN6 + A UNITS 25 B 26 + SHIELD + 27 FROM 0- 10V DC IN 28 + +0-10V BMS + -BMS IN COMMON 29 0- 10V DC OUT TO 30 + +0-10V + -RATE OUT COMMON BMS 31 MOD 32 + SHIELD CN1 + A BUS 33 + B 34 BMS SHIELD 35 + CN2 POOL OUT SAFETY OUTDOOR BK DOOR 10K 1 + SENSOR SUPPLY AIR G + 10K 20K 2 + SYS SUPPLY R 3 10K/20K W 10K SENSOR 10K + 10K 4 + SYS RETURN POOL/BOILER 10K 5 CN1 + SENSOR10K FROM 6 0-10V DC IN + 0-10V SYS PUMP 7 COMMON + - PUMP IN OUTPUT 8 CN2 ~~~~ ~~~~ ~~~~ FIELD WIRING TO MONITORING DEVICE BL BL Y Y W = WHITE T=TAN BK = BLACK Y=YELLOW PR=PURPLE BR=BROWN BL=BLUE G=GREEN P=PINK GY=GRAY R=RED O=ORANGE Y/G = YELLOW WITH GREEN STRIPE LBL20082 REV A
© Copyright 2026 Paperzz