TECHNICIAN`S REFERENCE GUIDE IMPORTANT! Track LighT with

DIAGNOSTIC GUIDE
Check
Solution
Monitor will not
power On.
1.
Check supply line voltage to TB1
terminal board.
If no voltage is present check supply
line fuse or circuit breaker in facility.
Monitor LED:
Green: Power ON.
2.
Check batteries (two 1.5 VAC, AAA
batteries) in Remote Control.
3.
4.
Amber: Power is On
(Standby) No signal.
6.
Track Monitor screen
is black.
Monitor picture is
“fuzzy” or “blurry”
when on Cable or PC
mode.
No Audio
If weak or dead replace batteries.
2. HDMI cable has no
“Repeater”.
Install the recommended HDMI Repeater and
Voltage Inserter.
Press Power switch on Monitor.
Monitor LED should be green.
Press Monitor Power switch.
If Monitor is powered but no signal is
present the LED will be Amber.
3. loose or not properly
Cable connections are
Repair connections.
Check all connections and
harnesses from supply line voltage
to Power Supply board and 12
VDC from Power Supply board to
Monitor.
Correct or replace connections or
harnesses.
4. on the “Repeater”.
Check for 12 VDC output on Power
Supply board between +V and
Gnd. terminals.
If no voltage present replace Power
Supply board.
Monitor has no
picture, picture is
not clear, or various
colored lines appear.
Substitute a known good 12 VDC
Monitor and check operation.
1.
2.
Check all cables and the
connections in track and flex arms
to assure they are good.
Correct connections or replace
damaged cables.
1.
Check ground wire connected to
the Line Power terminal board
(TB1).
Assure ground connection is secure.
If HDMI is being used, a repeater
is required.
Install a repeater in the HDMI Line.
3.
Adjust Monitor settings.
Refer to Corrections for Monitor
Distortion on this reference.
4.
Check all harnesses and
connections.
Correct connections and / or replace
problem harnesses.
5.
Assure good cable TV signal is
being supplied to system using a
known good Monitor or TV.
Contact cable supplier to correct
signal problems related to supplier.
6.
Too many connections on cable(s)
between video source and monitor.
Only 1 (One) cable per input between
source and monitor is recommended.
7.
Cable is below minimum
recommended specification for
optimal output.
Assure cable specifications meet
or excede the recommended cable
specifications.
1.
Check the Volume control on the
PC, and the Monitor.
Turn up volume on the PC and the
monitor.
Check all connections and cables
on the Audio.
Assure all connections are secure
and the cables are good. The 3.5mm
audio must be connected to a PC
Sound Card or an Audio Source.
Solid Red, Blue, Green, or Yellow
colors appear with picture.
Power needs to be cycled
Monitor drifts when
released from desired
position.
Light will not operate
when any function is
selected.
Monitor pivot joint tension
Adjust pivot joint tension on monitor mount
(complete instructions in User’s Guide).
Light is in Auto On mode
1. and flex arm is positioned
above horizontal plane.
Lower flex arm so that it is below the
horizontal plane. Light will come on.
2. Bulb is burned out or bad
Replace bulb or socket.
3. Power to light is Off.
Turn on power at source.
4. Fuse is open or blown.
Replace F1 fuse (refer to wiring diagram.)
5. Transformer open or
Check continuity. If open winding(s) replace
transformer.
6. Wire broken within light
Replace light harness(es).
7. Light control PCB
Replace PCB with known good one.
1. Faulty bulb
Replace bulb.
2. Facility Power is low.
Power should be 115 VAC (+/- 10%).
malfunctioning.
arm, flex arm or pivot joint.
malfunctioning.
Lighthead illuminates
but not a correct
intensity.
Lighthead shield is clouded
3. (may be due to using too
120 VAC
1.5 Amp
50/60 Hz
Transformer
Solid White Screen.
Check connections and channels
1. on tuner.
Head End of Track
12 VDC
Monitor
Power
Connects
to Facility
PC, DVD,
TV, etc.
Cycle power on the “Repeater” by unplugging
the “Voltage Inserter” power cord from the
outlet and plugging it back in.
1. requires adjustment.
socket.
Foot End of Track
Light Flex Arm
Suspension
Tube
Monitor Flex Arm
Additional
Suspension
Tube
Bulb
Light
Head
Connect to
Monitor
Connections (Monitor)
(Basic Connections Shown)
Replace Shield assembly.
strong disinfect / cleaning
solution.
Light is out of focus,
not producing a sharp
pattern.
1.
Light is out of focus.
Adjust light for desired focus. Focus is set
at factory at 27" (69 cm). See instructions on
opposite side or in User’s Guide.
For a clean appearance, attach all connectors to the monitor even though some may not be attached to the source.
Monitor Tension Adjustment
Adjustment
Nut
For additional setups refer to the Quick
Installation Guide (003-1928-00).
+
TECHNICIAN’S REFERENCE
GUIDE
Repair or replace the faulty
harness(es).
Broken wires in the VGA
harnesses produce these results:
1. Red wire = No red color on
Monitor.
Blue wire = No blue color on
Monitor.
Green wire = No green color on
Monitor.
2. Check connections.
No picture when on
Satellite or Digital
Tuner.
input.
connected.
If the substituted Monitor functions,
replace Monitor.
There is no signal coming from the
video source.
2.
Solution
Set monitor to HDMI input.
If Monitor LED is Amber colored
there is no signal to the monitor.
2.
No HDMI video and /
or audio present on
the monitor
Check
1. Monitor is not on HDMI
Black: Power OFF.
5.
Condition
User
Connections
Track Light with MONITOR
Model 153830-00X
Repair connections.
Use the satellite remote to change
satellite channels.
Repeater
An electronic device that receives and retransmits a signal at a higher power, or onto the other
side of an obstruction, so the signal can cover longer distances.
Voltage Inserter
A power supply that is used to by-pass the output power from an electronic device (DVD Player)
because the load may require more power than the device can supply.
•
•
IMPORTANT!
Keep this guide with this unit.
Fold and return to the plastic
envelope for storage.
Remove handle & cover.
While holding mount, turn adjusting screw to increase (+) or decrease (-) the tension.
NOTE
For Tension Adjustments at the Arm, Yoke, and Lighthead
pivots refer to the User’s Guide (003-1926-00).
DA2243i
003-1927-00 Rev. B
G
H RA
ER B
O TO E
PE
N
Condition
DIAGNOSTIC GUIDE
Correction for Monitor Distortion [continued]
(Adjustments on Monitor)
(If necessary, do this step last).
Correction for Monitor Distortion [continued]
(Adjustments on PC)
Monitor and remote control are manufactured by Exorvision.
Reference Exorvision’s literature for information on these components.
2.) Manually Adjusting Clock and Phase
Clock: To minimize any vertical bars or stripes visible on the back-
ground screen. The horizontal screen will also change.
www.Exorvision.com
Phase: Allows removal of any horizontal noise and to sharpen character images.
retraced to prevent the image from flickering.
The entire image area of most monitors is
refreshed approximately 60 times per second.
Click Start
Note
Click Control Panel
Double Click Display
Go to PC SETUP
Press ENTER (on remote).
Navigate to CLOCK and change setting
one or two increments to 49 or 51.
Navigate to PHASE and change setting
to sharpen image.
Note
Remote requires two
AAA 1.5 V batteries.
4.) Refresh Rate: The frequency with which the video screen is Click Settings
Go to OPTION
Check monitor and readjust if
necessary.
PICTURE AUDIO TIME OPTION LOCK CHANNEL
TECHNICIAN’S REFERENCE
GUIDE
Track Light with MONITOR
Model 153830-00X
On Settings Tab click Advanced
H-Pos50
V-Pos
AB
R E
G ER
H TO N
PE
O
Remote Control and Monitor
IMPORTANT!
Keep this guide with this unit.
Fold and return to the plastic
envelope for storage.
50
Clock50
Phase50
Auto Adjust
Press MENU (on remote) to exit.
© Midmark Corporation 2009
Correction for Monitor Distortion
(Adjustments on PC)
5.) Video Card: An expansion board that plugs into the PC to give display capabilities
3.) Screen Resolution: The setting that determines the amount of information
that appears on your screen, measured in pixels.
Note
Low Resolution, such as 640 x 480, makes items on the screen appear large, although the screen area is small
If the Monitor or PC adjustments do not clear up the distortion the Video Card may need replaced or a VGA Booster
may be required. Contact your dealer.
High Resolution, such as 1024 x 768, makes the overall screen area large, although individual items appear small.
Click Start
Click Settings
Click Control Panel
Double Click Display
Drag the Slider and then click Apply. When prompted to apply setting, click OK.
(The screen will turn black for a moment).
On the Monitor tab, in the Screen Refresh Rate list,
click a new refresh rate.
Light Focus Adjustment
Check the monitor manufacturer’s documentation in regards to the
settings the monitor supports.
Correction for Monitor Distortion (Adjustments on Monitor)
1.) Auto Adjust: Automatically adjusts the available options for the best
viewing of the PC settings (Using the Remote Control).
Go to MENU (Use Arrow Keys to navigate to various positions)
1. Pry Off
Cover
3. Adjust
Focus
PICTURE AUDIO TIME OPTION LOCK CHANNEL
Go to OPTION
Go to PC SETUP
Press ENTER (on remote).
OSD Language
Transparency
English
Off
PC Setup
Closed Caption
Restore Default
PICTURE AUDIO TIME OPTION LOCK CHANNEL
Go to AUTO ADJUST.
To start AUTO ADJUST press
ENTER (on remote)
(This only takes a few seconds).
Equipment Alert
H-Pos50
V-Pos
50
Clock
50
Phase
50
Auto Adjust
A higher Refresh Frequency reduces any flicker on your
screen, but choosing a setting that is too high for the monitor can
make the display unusable and cause damage to the hardware.
Note
Your monitor and video card determine how much you can change your
screen resolution.You may not be able to increase the resolution above a
certain level. Only the recommended screen resolutions are listed.
Once your screen resolution changes, you have 15 seconds to confirm the change.
Click Yes to confirm the change; click No or do nothing to revert to your previous
setting.
Dual Monitors
(Assure Correct Monitor is Identified)
Right click on monitor screen & go to Properties
Click Settings..........Press Identify....... Choose Monitor
2. Position light at desired distance from
target (ex. wall) and turn light on.
Adjustment Range
21 to 39 in.
(53 to 99 cm)
Factory Setting
27 in. (69 cm)