FX4D Comfortt Series Fan Coil Sizes 019 thru 061 Product Data AIR HANDLER TECHNOLOGY AT ITS FINEST The FX4D fan coils combine the proven technology of Carrier fan coil units with Puron®, the environmentally sound refrigerant. These fan coils are loaded with popular features. Factory--installed, refrigerant--specific thermostatic expansion valves (TXV) are standard with these fan coil designs. The designs feature contoured condensate pans with rugged, drain connections, ensuring that little water is left in the unit at the end of the cooling duty cycle. The lack of standing condensate and corrosion free pans improves IAQ and product life, features homeowners appreciate. Standard features include grooved copper tubing and louvered aluminum fins. The large face areas of the refrigerant coils provide superior efficiency for high SEER and HSPF performance. Coil circuiting has also been updated to make the most of all Carrier heat pumps and air conditioners. Also units come with solid state fan controls, 1--in (25mm) thick insulation with R--value of 4.2, multi--speed motors, and fully--wettable coils. Units can accommodate factory-- and/or field--installed heaters from 3 to 30 kW. It also should be noted that the unique cabinet design of these fan coils meet new stringent regulations for cabinet air leakage -- a requirement of 2% cabinet leakage rate when tested at 1.0 inches of static pressure. The FX4D fan coil is the Puron® refrigeration design loaded with popular features. It comes in a pre--painted (taupe metallic) galvanized steel casing and is shipped with a cleanable, permanent framed filter, and a factory--supplied power plug. ArmorCoatt provides a tin plating of the indoor coil’s copper hairpins. This creates a barrier between the corrosion--causing elements and the coil. These fan coils utilize the latest in electronic commutation motor (ECM) technology through the use of high efficiency, X13, blower motors. A10009 FX4D STANDARD FEATURES S S S S S S S S S S S S S S S S S S S S S S S S S High efficiency ECM (electronic commutating motor) X--13 motors -- all sizes Integrated motor controls have replaced integrated circuit board Large, grooved tube, louvered fin coils Efficient, quiet, time--tested blower housings and diffusers Sturdy, drainable condensate pans Cabinet construction features innovations designed to prevent cabinet sweating Tested for condensate disposal in much tougher conditions than Air Conditioning and Refrigeration Institute requirements Super--thick R--4.2 insulation with vapor barrier Pre--painted galvanized steel cabinet (taupe metallic) Cabinet design meets stringent regulations for 2% cabinet leakage rate when tested at 1.0 inches static pressure Installation--flexible, multipoise units Horizontal hanging provisions on cabinet No tools required to service filter Factory--supplied, cleanable and reusable filter Newly improved filter rack area filter door insulation added for improved air seal Factory--installed heater packages available (5-- through 15--kW) 3-- through 30--kW accessory heaters -- field installed Factory--supplied power plug Easy plug--in provisions for heater installation Entry options for high and low voltage wiring hook--up Simple, 5--amp blade fuse (and a spare) to protect 40 VA transformer Easy coil inspection (removable, snap--in plug on A--coil models) Leak--preventing sweat connections Modular cabinets available on 037 through 061 sizes. Designed for manufactured housing applications. ADDITIONAL FEATURES FX4D S S S S Puron®, environmentally sound refrigerant Factory--installed Puron® refrigerant thermostatic expansion valves (TXV) Factory--installed heater packages available ArmorCoatt coil protection available 2 MODEL NUMBER NOMENCLATURE CARRIER FAN COILS 1 F 2 X 3 4 4 D 5 N 6 B 7 0 8 1 9 9 10 0 Product Type Fan Coil, Multipoise with Puron 11 0 12 0 Heating Size 000 = No Heat 005 = 5kW 008 = 8 kW 010 = 10kW 015 = 15kW Electrical N -- 208/230v, 1 ph, 60 Hz Cabinet Style B -- Modular F -- Single Piece Coil Coating 0 = Standard T = ArmorCoatt FX4D Capacity 019 = 18,000 025 = 24,000 031 = 30,000 037 = 36,000 043 = 42,000 049 = 48,000 061 = 60,000 ISO 9001:2000 the environmentally sound refrigerant Use of the AHRI Certified TM Mark indicates a manufacturer’s participation in the program For verification of certification for individual products, go to www.ahridirectory.org. REGISTERED 3 DIMENSIONS UNIT A B C D E F G H J COIL CONFIGURATION SLOPE "A" SHIPPING WT (LBS) NON TIN-COATED SHIPPING WT (LBS) TIN-COATED FX4DNF019 49 5/8" 17 5/8" 15 3/4" 15 5/8" 15 3/8" 23 1/8" 23 5/8" - 17" X - 122 122 FX4DNF025 49 5/8" 17 5/8" 15 3/4" 15 5/8" 15 3/8" 23 1/8" 23 5/8" - 17" X - 122 122 X - FX4DNF031 53 7/16" 21 1/8" 19 1/4" 19 1/8" 19 3/16" 26 15/16" 27 1/2" - 19" 146 146 FX4DNF037 49 5/8" 21 1/8" 19 1/4" 19 1/8" 15 11/16" 23 7/16" 23 1/8" - - - X 157 157 FX4DNF043 49 5/8" 21 1/8" 19 1/4" 19 1/8" 15 11/16" 23 7/16" 23 1/8" - - - X 157 157 FX4DNF049 53 7/16" 24 11/16" 22 3/4" 22 11/16" 19 1/2" 27 1/4" 26 15/16" - - - X 185 185 FX4DNF061 59 3/16" 24 11/16" 22 3/4" 22 11/16" 25 1/4" 32 15/16" 32 5/8" - - - X 201 201 NOTE: NOTE: ALLOW 21" FROM FRONT FOR SERVICE 1. SERIES DESIGNATION IS THE 14TH POSITION OF UNIT PRODUCT NUMBER 2. ALL DIMENSIONS ARE IN "INCHES" UNLESS NOTED. UNIT CONNECTION SIZES SUCTION: 018 THRU 025 - 5/8" I.D. SWEAT 030 THRU 037 - 3/4" I.D. SWEAT 042 THRU 061 - 7/8" I.D. SWEAT LIQUID: 3/8" I.D. SWEAT CONDENSATE: 3/4" FPT 22 1/16" 10 3/16" FX4D 2 1/8" 7/8", 1 3/32" 2" DIA. K.O.'S FOR HIGH VOLTAGE POWER WIRING 1 7/8" 11" 1" K.O.'S 1 1/2" 1" 1 15/16" TOP VIEW 1 3/8" J 1 3/16" MAX DISCONNECT OR CIRCUIT BREAKER LOCATION H FOR MODULAR UNITS 19" B C 15/16" NOTE: MODULAR UNITS WILL HAVE A TWO-PIECE CABINET OPTIONAL FIELD CONVERTED RIGHT SIDE RETURN OPENING (SLOPE COIL UNITS ONLY) A 7/8"DIA. K.O. FOR LOW VOLTAGE CONTROL WIRING 3/4" OUTLET AIR ALTERNATE 7/8",1 3/32",2"DIA. FOR HIGH VOLTAGE POWER WIRING OPPOSITE SIDE ALTERNATE 7/8"DIA. K.O. FOR LOW VOLTAGE CONTROL WIRING 7/8" 1 3/4" BLOWER, CONTROL, & ELECTRIC HEATER ACCESS PANEL OPENING 19 13/16" 1 1/4" 2 1/2" RIGHT SIDE VIEW INLET AIR COIL ACCESS PANEL INLET AIR 2 5/8" 4 11/16" FITTING PANEL LIQUID LINE CONNECTION SUCTION LINE CONNECTION LIQUID LINE CONNECTION 3 1/16" E LIQUID LINE CONNECTION 10 7/16" SUCTION LINE CONNECTION 10 3/4" 6 3/16" 5" OPENING 1" 9 1/2" FILTER ACCESS PANEL D SLOPE COIL DETAILS INLET AIR CONNECTION LOCATIONS SHOWN FOR UPFLOW OR HORIZ. LEFT APPLICATIONS FRONT VIEW ACCESS PANEL CONFIG. FOR SLOPE COILS DOWNFLOW OR HORIZ. RIGHT APPLICATIONS AND "A" COILS SHOWN WITH "A" COIL DETAILS CONNECTION LOCATIONS FOR UPFLOW OR HORIZ. APPLICATIONS DOWNFLOW APPLICATIONS A10032 Fig. 1 -- FX4D -- English 4 DIMENSIONS (cont.) NOTES: 1. CONDENSATE PAN DRAIN CAPS NOT SHOWN FOR CLARITY. SLOPE COIL 2. ALL DIMENSIONS ARE IN "INCHES" UNLESS NOTED. AIRFLOW 2 3/16" TYP. (2 PLACES)* 7/16" TYP. (2 PLACES)* AIRFLOW 3 1/4" F G 1" TYP. (2 PLACES)* PRIMARY DRAIN 1 1/4" SECONDARY DRAIN SECONDARY DRAIN PRIMARY DRAIN 2 7/8" 1 1/4" DOWNFLOW (FIELD CONVERTED) FX4D 7/16" TYP. (4 PLACES)* 1" TYP. (2 PLACES)* 2 9/16" 3 1/4" 2 3/16" TYP. (2 PLACES)* UPFLOW (AS SHIPPED) PRIMARY DRAIN SECONDARY DRAIN 5/16" TYP.* PRIMARY DRAIN 1 13/16" TYP.* SECONDARY DRAIN 1 1/4" 1 5/8" 5/16" TYP.* 2 1/8" 1 13/16" TYP. 1/2" TYP.* 1 1/4" 7/8" TYP.* F 1/2" TYP.* 7/8" TYP.* HORIZ. RIGHT (FIELD CONVERTED) PRIMARY DRAIN 2 3/16" TYP. (2 PLACES)* 3 1/16" 1 1/2" 5/16" TYP* 5 7/8" 1 3/16" 7/8" TYP* G 5" AIRFLOW 1/2" TYP* 4 3/4" HORIZ. LEFT (AS SHIPPED) 1 13/16" TYP* SECONDARY DRAIN F 1 5/8" 2 7/8" A-COIL * HORIZONTAL MOUNT LOCATIONS - DIMPLES PROVIDED IN TOP PANEL, AND BACK OF CABINET. IN CABINET BOTTOM. HOLES PROVIDED AIRFLOW 5/16" TYP.* 1" TYP. (2 PLACES) 7 7/8" HORIZ. LEFT (AS SHIPPED) SECONDARY DRAIN 7/16" TYP. (4 PLACES) SECONDARY DRAIN PRIMARY DRAIN PRIMARY DRAIN PRIMARY DRAIN 5/16" TYP.* SECONDARY DRAIN 1" TYP. (2 PLACES)* 3" 1/8 1 1/2" 7/16" TYP, (4 PLACES)* DOWNFLOW (FIELD CONVERTED) 3 1/16" 5 7/8" 7 7/8" 1 13/16" TYP. 1 3/16" 1/2" TYP.* HORIZ. RIGHT (FIELD CONVERTED) 7/8" TYP.* 2 3/16" TYP. (2 PLACES)* 4 3/4" 2 11/16" UPFLOW (AS SHIPPED) A10033 Fig. 2 -- FX4D -- English 5 DIMENSIONS (cont.) UNIT A B C D E F G H COIL CONFIGURATION J SLOPE "A" SHIPPING WT (Kgs) NON TIN-COATED SHIPPING WT (Kgs) TIN-COATED FX4DNF019 1260.5 447.7 400.0 396.9 390.5 587.4 600.1 - 431.8 X - 55.3 55.3 FX4DNF025 1260.5 447.7 400.0 396.9 390.5 587.4 600.1 - 431.8 X - 55.3 55.3 FX4DNF031 1357.3 536.6 489.0 485.8 487.4 684.2 698.5 - 482.6 X - 66.2 66.2 FX4DNF037 1260.5 536.6 489.0 485.8 398.5 595.3 587.4 - - - X 71.2 71.2 FX4DNF043 1260.5 536.6 489.0 485.8 398.5 595.3 587.4 - - - X 71.2 71.2 FX4DNF049 1357.3 627.1 577.8 576.3 495.3 692.2 684.2 - - - X 84.1 84.1 FX4DNF061 1503.4 627.1 577.8 576.3 641.4 836.6 828.7 - - - X 91.2 91.2 NOTE: 1. SERIES DESIGNATION IS THE 14TH POSITION OF UNIT PRODUCT NUMBER NOTE: ALLOW 533.4 FROM FRONT FOR SERVICE UNIT CONNECTION SIZES 2. ALL DIMENSIONS ARE IN "MM" UNLESS NOTED. SUCTION: 018 THRU 025 - 15.88 I.D. SWEAT 030 THRU 037 - 19.05 I.D. SWEAT 042 THRU 061 - 22.23 I.D. SWEAT LIQUID: 9.53 I.D. SWEAT CONDENSATE: 19.0 FPT 560.4 258.8 FX4D 19.0 OUTLET AIR NOTE: MODULAR UNITS WILL HAVE A TWO-PIECE CABINET OPTIONAL FIELD CONVERTED RIGHT SIDE RETURN OPENING (SLOPE COIL UNITS ONLY) A 47.6 22.2 ALTERNATE 22.23, 27.78, 50.80 DIA. K.O.'S FOR HIGH VOLTAGE POWER WIRING OPPOSITE SIDE ALTERNATE 22.23 DIA. K.O. FOR LOW VOLTAGE CONTROL WIRING 22.23, 27.78 50.80 DIA. K.O.'S FOR HIGH VOLTAGE POWER WIRING 279.4 25.4 54.0 38.1 22.23 DIA. K.O. FOR LOW VOLTAGE CONTROL WIRING J 30.2 MAX 25.4 49.2 TOP VIEW H FOR MODULAR UNITS 482.6 34.9 44.4 B C 23.8 OPENING 503.2 31.8 DISCONNECT OR CIRCUIT BREAKER LOCATION 63.5 RIGHT SIDE VIEW INLET AIR BLOWER, CONTROL, & ELECTRIC HEATER ACCESS PANEL COIL ACCESS PANEL INLET AIR 66.7 119.1 FITTING PANEL LIQUID LINE CONNECTION SUCTION LINE CONNECTION LIQUID LINE CONNECTION 77.8 E LIQUID LINE CONNECTION 265.1 SUCTION LINE CONNECTION 273.0 157.2 127.0 OPENING 25.4 241.3 FILTER ACCESS PANEL D SLOPE COIL DETAILS CONNECTION LOCATIONS SHOWN FOR UPFLOW OR HORIZ. LEFT APPLICATIONS INLET AIR FRONT VIEW ACCESS PANEL CONFIG. FOR SLOPE COILS DOWNFLOW OR HORIZ. RIGHT APPLICATIONS AND "A" COILS SHOWN WITH "A" COIL DETAILS CONNECTION LOCATIONS FOR UPFLOW OR HORIZ. APPLICATIONS DOWNFLOW APPLICATIONS A10034 Fig. 3 -- FX4D -- Metric 6 DIMENSIONS (cont.) NOTES: 1. CONDENSATE PAN DRAIN CAPS NOT SHOWN FOR CLARITY. SLOPE COIL 2. ALL DIMENSIONS ARE IN "MM" UNLESS NOTED. 11.1 TYP. (2 PLACES)* AIRFLOW AIRFLOW 55.6 TYP. (2 PLACES)* 25.4 TYP. (2 PLACES)* PRIMARY DRAIN 82.6 F G SECONDARY DRAIN 31.8 SECONDARY DRAIN PRIMARY DRAIN 73.0 31.8 82.6 55.6 TYP. (2 PLACES)* DOWNFLOW (FIELD CONVERTED) 65.1 FX4D 11.1 TYP. (4 PLACES)* 25.4 TYP. (2 PLACES)* UPFLOW (AS SHIPPED) PRIMARY DRAIN SECONDARY DRAIN PRIMARY DRAIN 8.0 TYP.* 46.0 TYP.* SECONDARY DRAIN 31.8 41.3 54.0 46.0 TYP.* 31.8 8.0 TYP.* 12.7 TYP.* 12.7 TYP.* 22.2 TYP.* F 41.3 73.0 22.2 TYP.* HORIZ. RIGHT (FIELD CONVERTED) HORIZ. LEFT (AS SHIPPED) 127.0 A-COIL * HORIZONTAL MOUNT LOCATIONS - DIMPLES PROVIDED IN TOP PANEL, AND BACK OF CABINET. IN CABINET BOTTOM. HOLES PROVIDED 3.45 DIA. HORIZONTAL HANGING HARDWARE TO BE FIELD SUPPLIED. PRIMARY DRAIN 46.0 TYP* SECONDARY DRAIN AIRFLOW 55.6 TYP. (2 PLACES)* AIRFLOW 12.7 TYP* F 22.2 TYP* G 120.6 77.8 38.1 8.0 TYP* 149.2 30.2 25.4 TYP. (2 PLACES) 200.0 HORIZ. LEFT (AS SHIPPED) SECONDARY DRAIN 11.1 TYP. (4 PLACES) SECONDARY DRAIN PRIMARY DRAIN PRIMARY DRAIN PRIMARY DRAIN 8.0 TYP.* SECONDARY DRAIN 25.4 TYP. (2 PLACES)* 79.4 11.1 TYP, (4 PLACES)* 38.1 DOWNFLOW (FIELD CONVERTED) 149.2 200.0 46.0 TYP. 30.2 77.8 12.7 TYP.* HORIZ. RIGHT (FIELD CONVERTED) 22.2 TYP.* 55.6 TYP. (2 PLACES)* 120.6 68.3 UPFLOW (AS SHIPPED) A10035 Fig. 4 -- FX4D -- Metric 7 PHYSICAL DATA FX4D ORDERING NO. FX4DNF0190,T)00 FX4DNF019005 FX4DNF025(0,T)00 FX4DNF025005 FX4DNF031(0,T)00 FX4DNF031008 FX4DNF037(0,T)00 FX4DNF037010 FX4DNF043(0,T)00 FX4DNF043010 FX4DNF049(0,T)00 FX4DNF049010 FX4DNF061(0,T)00 FX4DNF061010 FX4DNF061015 FACTORY INSTALLED HEAT (kW) --5 --5 --8 --10 --10 --10 --10 15 NOMINAL COOLING CAPACITY (Btuh) 18,000 24,000 30,000 36,000 42,000 48,000 60,000 FX4DNB031T00 --- 30,000 FX4DNB037T00 --- 36,000 FX4DNB043T00 --- 42,000 FX4DNB049T00 --- 48,000 FX4DNB061T00 --- 60,000 DIMENSIONS Height Width Depth SHIPPING WEIGHT 49 5/8--- in 1261mm 49 5/8--- in 1261mm 53 7/16--- in 1357mm 49 5/8--- in 1261mm 49 5/8--- in 1260mm 53 7/16--- in 1357mm 17 5/8--- in 447mm 17 5/8--- in 447mm 21 1/8--- in 536mm 21 1/8--- in 536mm 21 1/8--- in 536mm 24 11/16--- in 627mm 22--- 1/16--- in 560mm 22--- 1/16--- in 560mm 22--- 1/16--- in 560mm 22--- 1/16--- in 560mm 22--- 1/16--- in 560mm 22--- 1/16--- in 560mm 122 lb 55 kg 122 lb 55 kg 146 lb 66 kg 157 lb 71 kg 157 lb 71 kg 185 lb 84 kg 59 3/16--- in 1503mm 24 11/16--- in 627mm 22--- 1/16--- in 560mm 201 lb 91 kg 53 7/16--- in 1357mm 53 7/16--- in 1357mm 53 7/16--- in 1357mm 53 7/16--- in 1357mm 59 3/16--- in 1503mm 21 1/8--- in 536mm 21 1/8--- in 536mm 21 1/8--- in 536mm 24 11/16--- in 627mm 24 11/16--- in 627mm 22--- 1/16--- in 560mm 22--- 1/16--- in 560mm 22--- 1/16--- in 560mm 22--- 1/16--- in 560mm 22--- 1/16--- in 560mm 146 lb 66 kg 175 lb 79kg 175 lb 79kg 185 lb 84 kg 201 lb 91 kg 6th digit: B --- Modular cabinet, F --- Single piece cabinet 10th digit: 0 --- Standard copper coil, T --- ArmorCoatt SPECIFICATIONS MODEL FX4D 019 025 031 037 043 049 061 COIL Puronr Refrigerant TXV --- factory installed hard --- shutoff, bi--- flow type for heat pump application Metering Device TXV 2 ton 3 ton 4 ton Rows/Fins Per In. 3 / 14.5 Face Area (Sq. Ft.) 2.97 3.46 4.45 5.93 7.42 Configuration Slope A FAN CFM (Nominal) 600 800 1000 1200 1400 1600 2000 Motor Type (ECM) X--- 13 X--- 13 X--- 13 X--- 13 X--- 13 X--- 13 X--- 13 Motor Hp 1/3 1/3 1/2 1/2 1/2 3/4 3/4 FILTER 21--- 1/2--- in / 546 mm X 16--- 3/8--- in / 417 mm 19--- 7/8--- in / 505 mm 23--- 5/16--- in / 585 mm CABINET CONFIGURATION OPTIONS 1--- pc 1--- pc / Modular 8 PERFORMANCE DATA MODEL & SIZE FX4D 019 FX4D 025 FX4D 031 FX4D 037 FX4D 043 FX4D 049 FX4D 061 BLOWER SPEED Tap 5 Tap 4 Tap 3 Tap 2 Tap 1 Tap 5 Tap 4 Tap 3 Tap 2 Tap 1 Tap 5 Tap 4 Tap 3 Tap 2 Tap 1 Tap 5 Tap 4 Tap 3 Tap 2 Tap 1 Tap 5 Tap 4 Tap 3 Tap 2 Tap 1 Tap 5 Tap 4 Tap 3 Tap 2 Tap 1 Tap 5 Tap 4 Tap 3 Tap 2 Tap 1 0.10 0.20 0.30 0.40 0.50 0.60 776 683 683 631 625 956 825 825 726 631 1189 1041 1041 924 779 1363 1237 1237 1095 1014 1519 1437 1437 1257 1237 1757 1664 1664 1459 1301 2030 1811 1811 1665 1462 745 644 644 563 524 920 795 795 695 563 1151 998 998 876 693 1332 1206 1206 1058 885 1490 1403 1403 1226 1206 1725 1626 1626 1420 1241 1995 1775 1775 1632 1418 696 589 589 500 457 891 757 757 635 500 1104 944 944 817 628 1294 1160 1160 1007 773 1454 1366 1366 1191 1160 1693 1593 1593 1379 1195 1961 1740 1740 1593 1371 660 548 548 443 417 851 722 722 598 443 1050 886 886 752 571 1253 1121 1121 951 673 1419 1333 1333 1141 1121 1653 1552 1552 1336 1150 1927 1703 1703 1556 1327 609 494 494 409 367 816 674 674 543 409 1003 837 837 704 526 1207 1070 1070 888 609 1379 1294 1294 1090 1070 1614 1517 1517 1298 1102 1888 1664 1664 1507 1278 572 461 461 361 319 780 634 634 509 361 959 772 772 660 476 1157 1013 1013 824 549 1332 1245 1245 1033 1013 1576 1477 1477 1259 1039 1842 1613 1613 1453 1228 --- Airflow outside 450 cfm/ton. NOTES: 1. Airflow based upon dry coil at 230v with factory--approved filter and electric heater (2 element heater sizes 018 through 037, 3 element heater sizes 043 through 061). 2. Airflow at 208 volts is approximately the same as 230 volts because the X--13 motor is a constant torque motor. The torque doesn’t drop off at the speeds the motor operates. 3. To avoid potential for condensate blowing out of drain pan prior to making drain trap: Return static pressure must be less than 0.40 in wc. Horizontal applications of 043 -- 061 sizes must have supply static greater than 0.20 in wc. 4. Airflow above 400 cfm/ton on 049--061 size could result in condensate blowing off coil or splashing out of drain pan. 9 FX4D AIRFLOW PERFORMANCE (CFM) PERFORMANCE DATA (cont.) GROSS COOLING CAPACITIES (MBH) -- PURONr REFRIGERANT UNIT SIZE FX4D FX4D 019 FX4D 025 FX4D 031 FX4D 037 FX4D 043 FX4D 049 FX4D 061 INDOOR COIL AIR CFM EWB 72 / 22 67 / 19 525 62 / 17 72 / 22 67 / 19 600 62 / 17 72 / 22 67 / 19 675 62 / 17 72 / 22 67 / 19 700 62 / 17 72 / 22 67 / 19 800 62 / 17 72 / 22 67 / 19 900 62 / 17 72 / 22 67 / 19 875 62 / 17 72 / 22 67 / 19 1000 62 / 17 72 / 22 67 / 19 1125 62 / 17 72 / 22 67 / 19 1050 62 / 17 72 / 22 67 / 19 1200 62 / 17 72 / 22 67 / 19 1350 62 / 17 72 / 22 67 / 19 1225 62 / 17 72 / 22 67 / 19 1400 62 / 17 72 / 22 67 / 19 1575 62 / 17 72 / 22 67 / 19 1400 62 / 17 72 / 22 67 / 19 1600 62 / 17 72 / 22 67 / 19 1800 62 / 17 72 / 22 67 / 19 1600 62 / 17 72 / 22 67 / 19 1750 62 / 17 72 / 22 67 / 19 2000 62 / 17 TC 36 29 23 40 33 26 44 36 29 48 39 31 53 43 34 57 47 37 59 48 38 65 53 42 71 58 46 67 54 43 74 60 48 81 66 52 79 64 51 87 71 56 95 77 61 90 73 58 100 81 65 109 89 70 109 89 71 117 95 76 129 105 84 35 / 2 SHC 19 19 19 21 21 21 23 23 24 25 25 25 27 28 28 30 30 31 30 31 31 33 34 35 36 37 38 36 37 37 40 41 41 43 45 46 41 42 43 46 47 48 50 51 52 48 49 49 53 54 55 58 59 60 57 58 59 61 62 63 67 69 70 BF 0.00 0.01 0.02 0.00 0.02 0.02 0.00 0.02 0.03 0.00 0.03 0.03 0.00 0.04 0.04 0.00 0.05 0.05 0.00 0.03 0.04 0.00 0.04 0.05 0.00 0.05 0.06 0.00 0.03 0.03 0.00 0.04 0.04 0.00 0.05 0.05 0.00 0.04 0.04 0.00 0.05 0.06 0.00 0.06 0.07 0.00 0.03 0.03 0.00 0.04 0.04 0.00 0.05 0.05 0.00 0.02 0.03 0.00 0.03 0.03 0.00 0.04 0.04 SATURATED TEMPERATURE LEAVING EVAPORATOR (_F / °C) 40 / 4 45 / 7 50 / 10 TC SHC BF TC SHC BF TC SHC BF 33 17 0.00 28 15 0.00 24 13 0.00 26 17 0.01 22 15 0.02 17 13 0.02 20 17 0.02 16 15 0.02 12 12 0.07 36 19 0.00 32 17 0.00 27 14 0.01 29 19 0.02 24 17 0.02 19 14 0.02 22 19 0.02 17 17 0.03 13 13 0.08 40 21 0.00 35 18 0.00 29 16 0.02 32 21 0.03 26 18 0.03 21 16 0.03 24 21 0.03 19 19 0.04 15 15 0.10 43 22 0.00 37 19 0.00 31 17 0.02 34 22 0.03 28 20 0.03 22 17 0.03 26 23 0.03 20 20 0.04 16 16 0.10 47 24 0.00 41 21 0.01 35 18 0.03 37 25 0.04 31 22 0.04 25 19 0.04 29 25 0.04 23 22 0.05 18 18 0.12 51 27 0.00 45 23 0.03 38 20 0.04 41 27 0.05 34 24 0.05 27 21 0.05 31 28 0.05 25 24 0.06 20 20 0.14 53 27 0.00 46 24 0.01 38 20 0.02 42 28 0.03 35 24 0.04 27 21 0.04 32 28 0.04 25 24 0.04 20 20 0.11 58 30 0.00 51 26 0.02 42 23 0.04 46 31 0.04 38 27 0.05 30 23 0.05 35 31 0.05 28 27 0.06 22 22 0.13 63 33 0.00 55 29 0.03 46 25 0.05 50 33 0.05 42 29 0.06 33 25 0.06 38 34 0.06 30 30 0.07 24 24 0.15 60 32 0.00 52 28 0.00 44 24 0.02 47 33 0.03 40 29 0.03 31 25 0.03 36 33 0.03 29 29 0.04 22 22 0.10 66 36 0.00 58 31 0.01 48 27 0.03 52 36 0.04 44 32 0.04 35 27 0.04 40 37 0.04 32 32 0.05 25 25 0.12 72 39 0.00 63 34 0.03 53 30 0.04 57 40 0.05 48 35 0.05 38 30 0.05 44 41 0.05 35 36 0.06 28 28 0.14 71 37 0.00 62 33 0.02 52 28 0.03 56 38 0.04 47 33 0.04 37 29 0.04 43 38 0.04 34 34 0.05 27 27 0.12 78 41 0.00 68 36 0.03 57 31 0.04 62 42 0.05 52 37 0.05 41 32 0.05 47 43 0.06 38 38 0.06 30 30 0.14 85 45 0.00 74 39 0.04 62 34 0.05 67 46 0.06 56 40 0.06 44 35 0.07 51 47 0.07 41 41 0.08 33 33 0.17 81 43 0.00 71 38 0.00 59 32 0.02 64 44 0.03 54 38 0.03 42 33 0.03 49 44 0.03 39 39 0.04 30 30 0.10 89 48 0.00 78 42 0.01 65 36 0.03 71 48 0.04 59 43 0.04 47 36 0.04 54 49 0.04 43 43 0.05 34 34 0.12 97 52 0.00 85 46 0.03 71 39 0.04 77 53 0.05 65 47 0.05 51 40 0.05 59 54 0.05 47 48 0.06 37 37 0.14 98 51 0.00 86 45 0.00 73 39 0.01 78 52 0.02 66 46 0.02 52 39 0.03 60 52 0.03 48 46 0.03 37 37 0.09 105 55 0.00 92 48 0.01 78 41 0.02 84 56 0.03 70 49 0.03 56 42 0.03 64 56 0.03 51 50 0.04 40 40 0.10 116 60 0.00 102 53 0.02 86 46 0.03 92 62 0.04 78 54 0.04 62 47 0.04 71 63 0.04 57 55 0.05 45 45 0.12 See Notes following table. 10 TC 19 12 10 21 13 11 23 15 12 25 16 13 27 17 15 30 19 16 30 19 16 33 21 18 36 23 20 35 22 18 38 24 21 41 27 23 41 26 22 45 29 25 48 31 27 47 30 25 51 33 28 56 36 31 58 37 31 62 40 33 68 44 37 55 / 13 SHC 11 10 10 12 12 11 13 13 12 14 14 13 15 16 15 17 17 16 17 17 16 19 19 18 20 21 20 20 20 18 22 23 21 25 25 23 23 24 22 26 26 25 28 29 27 27 27 25 30 30 28 33 33 31 32 33 31 35 35 33 38 39 37 BF 0.01 0.02 0.24 0.02 0.03 0.25 0.02 0.03 0.26 0.03 0.04 0.26 0.04 0.05 0.28 0.05 0.06 0.29 0.03 0.04 0.27 0.04 0.05 0.29 0.05 0.07 0.30 0.03 0.04 0.26 0.04 0.05 0.28 0.05 0.06 0.29 0.04 0.05 0.28 0.05 0.06 0.29 0.06 0.07 0.31 0.03 0.04 0.26 0.04 0.05 0.28 0.05 0.06 0.29 0.02 0.03 0.24 0.02 0.03 0.25 0.03 0.05 0.27 PERFORMANCE DATA (cont) EWB --- Entering Wet Bulb _F (_C) BF --- Bypass Factor LWB --- Leaving Wet Bulb _F (_C) MBH --- 1000 Btuh NOTES: TC --- Gross Cooling Capacity 1000 Btuh SHC CORRECTION FACTOR 1. Contact manufacturer for cooling capacities at conditions other than shown in table. 2. Formulas: Leaving db = entering db --sensible heat cap. 1.09 x CFM Leaving wb = wb corresponding to enthalpy of air leaving coil (hlwb) hlwb = hewb --total capacity (Btuh) 4.5 x CFM where hewb = enthalpy of air entering coil. Direct interpolation is permissible. Do not extrapolate. 3. SHC is based on 80_F (27_C) db temperature of air entering coil. Below 80_F (27_C) db, subtract (Correction Factor x CFM) from SHC. Above 80_F (27_C) db, add (Correction Factor x CFM) to SHC. 4. Bypass Factor = 0 indicates no psychometric solution. Use bypass factor of next lower EWB for approximation. ENTERING AIR DRY-- BULB TEMPERATURE (_F) BYPASS FACTOR 79 78 77 76 75 Under 75 81 82 83 84 85 Over 85 ENTERING AIR DRY-- BULB TEMPERATURE (_C) 26 25 25 24 24 Under 75 27 28 28 29 29 Over 85 Use formula shown below Correction Factor 0.10 .098 1.96 2.94 3.92 4.91 0.20 0.87 1.74 2.62 3.49 4.36 0.30 0.76 1.53 2.29 3.05 3.82 Interpolation is permissible. Correction Factor = 1.09 x (1 --- BF) x (db --- 80) FX4D CFM --- Cubic Ft per Minute SHC --- Gross Sensible Capacity 1000 Btuh MINIMUM CFM AND MOTOR SPEED SELECTION FAN COIL SIZES FX 019 025 031 037 043 049 061 * 3 525 700 — — — — — 5 525 700 875 1050 — — — 8 525 700 875 970 1225 1400 1750 9 — — — 970 1225 1400 1750 HEATER kW 10 15 600* — 700 775* 875 875 970 920 1225 1225 1400 1400 1750 1750 18 — — — — 1225 1400 1750 20 — — 1060* 1040 1225 1400 1750 24 — — — — — 1400 1750 30 — — — — — 1400 1750 Indicates medium speed (blue). All other motor speeds at low tap. AIR DELIVERY PERFORMANCE CORRECTION COMPONENT PRESSURE DROP (in wc) AT INDICATED AIRFLOW (DRY--TO--WET COIL) FX SIZE 019 025 031 037 043 049 061 500 0.034 0.016 --- ----- ----- ----- ----- --- 600 0.049 0.027 --- ----- ----- ----- ----- --- 700 0.063 0.038 --- ----- ----- ----- ----- --- 800 --- --0.049 0.049 --- ----- ----- ----- --- 900 --- --0.059 0.059 --- ----- ----- ----- --- 1000 --- ----- --0.070 0.055 --- ----- ----- --- 1100 --- ----- --0.080 0.064 --- ----- ----- --- CFM 1200 1300 --- ----- ----- ----- ----- ----- --0.073 0.081 0.049 0.056 --- ----- ----- ----- --- 11 1400 --- ----- ----- ----- --0.063 0.038 --- --- 1500 --- ----- ----- ----- --0.070 0.043 --- --- 1600 --- ----- ----- ----- ----- --0.049 0.027 1700 --- ----- ----- ----- ----- --0.054 0.031 1800 --- ----- ----- ----- ----- --0.059 0.035 1900 --- ----- ----- ----- ----- ----- --0.039 2000 --- ----- ----- ----- ----- ----- --0.043 PERFORMANCE DATA (cont) FACTORY--INSTALLED FILTER STATIC PRESSURE DROP (in wc) UNIT SIZE FX4D 019, 025 031, 037, 043 049, 061 400 0.012 ----- 600 0.022 ----- 800 0.048 0.036 --- CFM 1200 --0.07 --- 1000 0.072 0.051 --- 1400 --0.092 0.073 1600 --0.12 0.086 1800 ----0.105 2000 ----0.13 ELECTRIC HEATER STATIC PRESSURE DROP (in wc) FX4D 019 --- 037 HEATER ELEMENTS kW 0 1 2 3 4 0 3, 5 8, 10 9, 15 20 EXTERNAL STATIC PRESSURE CORRECTION +.02 +.01 0 –.02 –.04 043 --- 061 HEATER ELEMENTS KW 0 2 3 4 6 0 8, 10 9, 15 20 18, 24, 30 EXTERNAL STATIC PRESSURE CORRECTION +.04 +.02 0 –.02 –.10 The airflow performance data was developed using fan coils with 10 ---kW electric heaters (2 elements) in the 019 through 037 size units and 15 ---kW heaters (3 elements) in the 043through 061 size units. For fan coils with heaters of a different number of elements, the external available static at a given CFM from the curve may be corrected by adding or subtracting available external static pressure as indicated above. ACCESSORY ELECTRIC HEATERS * HEATER PART NO. kW @ 240V VOLTS/ PH STAGES (kW OPERATING) KFCEH0401N03 KFCEH0501N05 KFCEH0801N08 KFCEH0901N10 KFCEH3201F20 KFCEH1601315 KFCEH2001318 KFCEH3401F24 KFCEH3501F30 KFCEH2401C05 KFCEH2501C08 KFCEH2601C10 KFCEH3301C20 KFCEH2901N09 KFCEH3001F15 KFCEH3101C15 3 5 8 10 20 15 18 24 30 5 8 10 20 9 15 15 230/1 230/1 230/1 230/1 230/1 230/3 230/3 230/3* 230/3* 230/1 230/1 230/1 230/1 230/1{ 230/1 230/1 3 5 8 10 5, 20 5, 15 6, 12, 18 8, 16, 24 10, 20, 30 5 8 10 5, 20 3, 9 5, 15 5, 15 INTERNAL CIRCUIT PROTECTION None None None None Fuse} None None Fuse Fuse Circuit Breaker Circuit Breaker Circuit Breaker Circuit Breaker None Fuse} Circuit Breaker FAN COIL SIZE USED WITH HEATING CAP.** @ 230V 018–024 018–060 018–060 018–060 030–060 036–060 042–060 048, 060 048, 060 018–060 018–060 018–060 030–060 036–060 024–060 024–060 9,400 15,700 25,100 31,400 62,800 47,100 56,500 78,300 94,100 15,700 25,100 31,400 62,800 28,200 47,100 47,100 Field convertible to 1 phase. { Field convertible to 3 phase. } Single point wiring kit required for these heaters in Canada. ** Blower Motor heat not included. ESTIMATED SOUND POWER LEVEL (dBA) * UNIT SIZE FX CONDITIONS OCTAVE BAND CENTER FREQUENCY* CFM Ext Static Pressure 63 125 250 500 1000 2000 4000 019 600 0.25 64.7 60.7 56.7 53.7 51.7 49.7 45.7 025 800 0.25 66.0 62.0 58.0 55.0 53.0 51.0 47.0 031 1000 0.25 67.0 63.0 59.0 56.0 54.0 52.0 48.0 037 1200 0.25 67.8 63.8 59.8 56.8 54.8 52.8 48.8 043 1400 0.25 68.4 64.4 60.4 57.4 55.4 53.4 49.4 049 1600 0.25 69.0 65.0 61.0 58.0 56.0 54.0 50.0 061 2000 0.25 70.0 66.0 62.0 59.0 57.0 55.0 51.0 Estimated sound power levels have been derived using the method described in the 1987 ASHRAE HVAC Systems & Applications Handbook, Chapter 52, p. 52.7. 12 ELECTRICAL DATA FOR UNITS WITH FACTORY--INSTALLED HEAT SINGLE CIRCUIT HEAT PACK FX4DNF MTR MTR VOLTS/PH/ INSTALLED Heater MODEL NO. HP FLA HZ MCA MOCP MKFCEH Amps 019005 025005 031008 037010 043010 049010 061010 061(0,T)015 1/3 1/3 1/2 1/2 1/2 3/4 3/4 3/4 2.8 2.8 4.1 4.1 4.1 6.0 6.0 6.0 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 MCA --- Minimum Circuit Amps MOCP --- Maximum Overcurrent Protection 0501N05 0501N05 0801N08 0901N10 0901N10 0901N10 0901N10 1501F15 18.1/20.0 18.1/20.0 28.9/32.0 36.2/40.0 36.2/40.0 36.2/40.0 36.2/40.0 54.2/59.9 26.1/28.5 26.1/28.5 41.3/45.2 50.4/55.1 50.4/55.1 52.8/57.5 52.8/57.5 75.3/82.4 30/30 30/30 45/50 60/60 60/60 60/60 60/60 80/90 DUAL CIRCUIT Htr. Htr. MCA MOCP MCA MOCP Amps Amps L1/L2 L1/L2 L1/L2 L3/L4 L3/L4 L3/L4 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 36.2/40.0 52.8/57.5 60/60 18.1/20.0 22.6/25.0 25/25 MODEL NO. MTR HP MTR FLA VOLTS/PH/HZ FX4DNF019(0,T)00 FX4DNF025(0,T)00 FX4DNF031(0,T)00 FX4DNF037(0,T)00 FX4DNF043(0,T)00 FX4DNF049(0,T)00 FX4DNF061(0,T)00 FX4DNB031T00 FX4DNB037T00 FX4DNB043T00 FX4DNB049T00 FX4DNB061T00 1/3 1/3 1/2 1/2 1/2 3/4 3/4 1/2 1/2 1/2 3/4 3/4 2.8 2.8 4.1 4.1 4.1 6.0 6.0 4.1 4.1 4.1 6.0 6.0 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 SINGLE CIRCUIT MAXIMUM OVERCURRENT MCA PROTECTION 3.5 15 3.5 15 5.1 15 5.1 15 5.1 15 7.5 15 7.5 15 5.1 15 5.1 15 5.1 15 7.5 15 7.5 15 * BRANCH CIRCUIT MIN WIRE SIZE* AWG 14 14 14 14 14 14 14 14 14 14 14 14 Use copper wire only. Use 75_C only in this application. When using non ---metallic (NM) sheathed cable, wire size required should be based on that of 60_C conductors, instead of wire sizes shown in table above per NEC Article 336 ---26. NOTE: If branch circuit wire length exceeds 100 ft (30 m), consult NEC 215 ---2 to determine maximum wire length. Use 2% voltage drop. FLA --- Full Load Amps 13 FX4D ELECTRICAL DATA FOR UNITS WITHOUT ELECTRICAL HEAT 14 18.0 18.0 22.5 22.5 5 5 8 8 9 9 10 10 15 15 15 18 20 20 24 24 30 30 KFCEH2401C051 KFCEH2401C052 KFCEH0801N08 KFCEH2501C08 KFCEH2901N09 KFCEH2901N09** KFCEH0901N10 KFCEH2601C10 KFCEH3001F15 KFCEH3101C15 KFCEH1601315 KFCEH2001318 KFCEH3201F20 KFCEH3301C20 15.0 13.5 11.3 11.3 11.3 7.5 7.5 6.8 6.8 6.0 6.0 3.8 3.8 3.8 1 3 1 3 1 1 3 3 1 1 1 1 3 1 1 1 1 1 1 1 1 P H A S E Fuse Fuse Fuse Fuse Ckt Bkr Fuse None None Ckt Bkr Fuse Ckt Bkr None None None Ckt Bkr None Ckt Bkr Ckt Bkr None None None INTERNAL CIRCUIT PROTECTION 109.0/120.0 62.6/69.2 86.7/95.5 50.1/55.4 — 72.3/79.9 37.6/41.5 31.3/34.6 — 54.2/59.9 36.2/40.0 36.2/40.0 18.8/20.8 32.8/36.0 28.9/32.0 28.9/32.0 18.1/20.0 18.1/20.0 18.1/20.0 18.1/20.0 10.9/12.0 Single Circuit — — — — 36.2/40.0 36.2/40.0 — — 36.2/40.0 36.2/40.0 — — — — — — — — — — — L1,l2 — — — — 36.2/40.0 36.2/40.0 — — 18.1/20.0 18.1/20.0 — — — — — — — — — — — L3,L4 Dual Circuit HEATER AMPS 208/230V 144.8/158.5 86.8/95.0 116.9/127.9 71.2/77.8 — 98.9/108.4 55.5/60.4 47.7/51.8 — 76.3/83.4 53.8/58.5 53.8/58.5 32.0/34.5 49.5/53.5 44.7/48.5 44.7/48.5 31.2/33.5 26.0/28.4 31.2/33.5 26.0/28.4 15.9/17.3 Single Circuit — — — — 53.8/58.5 53.8/58.5 — — 53.8/58.5 53.8/58.5 — — — — — — — — — — — L1,L2 — — — — 45.3/50.0 45.3/50.0 — — 22.7/25.0 22.7/25.0 — — — — — — — — — — — L3,L4 Dual Circuit Min Ampacity 208/230V* kW 22.5 18.0 208V 1 1 P H A S E L1,L2 36.2/40.0 28.9/32.0 36.2/40.0 28.9/32.0 L3,L4 HEATER AMPS 208/230V L5,L6 36.2/40.0 28.9/32.0 L1,L2 53.8/58.5 44.7/48.5 45.3/50.0 36.2/40.0 L3,L4 MIN AMPACITY 208/230V* L5,L6 45.3/50.0 36.2/40.0 — — — — 8/8 8/8 — — 10/10 10/10 — — — — — — — — — — — 6/6 8/8 L1,L2 8/8 8/8 L3,L4 8/8 8/8 L5,L6 — — — — 10/10 10/10 — — 10/10 10/10 — — — — — — — — — — — 10/10 10/10 150/175 90/100 125/150 80/80 — 100/110 60/70 50/60 — 80/90 60/60 60/60 35/35 50/60 45/50 45/50 35/35 30/30 35/35 30/30 20/20 Single Circuit 60/60 45/50 L1,L2 50/50 40/40 L3,L4 50/50 40/40 L5,L6 — — — — 60/60 60/60 — — 60/60 60/60 — — — — — — — — — — — L1,L2 117/150 97/98 115/116 94/95 — 85/109 76/77 56/90 — 88/89 78/80 78/80 83/85 54/87 59/60 59/60 85/88 66/66 85/88 66/66 67/68 Single Circuit 78/80 59/60 L1,L2 59/59 73/73 L3,L4 59/59 73/73 L5,L6 — — — — 78/80 78/80 — — 78/80 78/80 — — — — — — — — — — — L1,L2 — — — — 59/59 59/59 — — 75/76 75/76 — — — — — — — — — — — L3,L4 Dual Circuit Max Wire Length 208/230V (Ft)‡ MAX WIRE LENGTH 208/230V (FT)‡ — — — — 50/50 50/50 — — 25/25 25/25 — — — — — — — — — — — L3,L4 Dual Circuit Max Fuse/Ckt Bkr Amps 208/230V MAX FUSE/CKT BKR AMPS 208/230V — — — — 10/10 10/10 — — 10/10 10/10 — — — — — — — — — — — L3,L4 Dual Circuit L1, L2 MIN GND WIRE SIZE 208/230V 6/6 8/8 6/6 8/8 — 8/6 10/8 10/10 — 8/8 10/10 10/10 10/10 10/10 10/10 10/10 10/10 10/10 10/10 10/10 12/12 Single Circuit Min Gnd Wire Size 208/230V BRANCH CIRCUIT Includes blower motor amps of largest fan coil used with heater. Copper wire must be used. If other than uncoated (non ---plated), 75_C ambient, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the National Electric Code (ANSI/NFPA 70). } Length shown is as measured 1 way along wire path between unit and service panel for a voltage drop not to exceed 2%. ** Field convertible to 3 phase. {{ Field convertible to 1 phase, single or multiple supply circuit. NOTES: 1. For fan coil sizes 018 ---037. 2. For fan coil sizes 042 ---061. 3. Single circuit application of F15 and F20 heaters requires single ---point wiring kit accessory. 30 KFCEH3501F30†† * { 24 240V KFCEH3401F24†† HEATER PART NO. — — — — 6/6 6/6 — — 6/6 6/6 — — — — — — — — — — — L3, L4 MIN WIRE SIZE (AWG) 208/230V† 0/00 3/3 1/1 4/4 — 3/2 6/6 8/6 — 4/4 6/6 6/6 8/8 8/6 8/8 8/8 8/8 10/10 8/8 10/10 12/12 L1, L2 Dual Circuit Min Wire Size (AWG) 208/230V† Single Circuit FIELD MULTIPOINT WIRING OF 24--AND 30--kW SINGLE PHASE KFCEH3501F30†† KFCEH3401F24†† 15.0 5 KFCEH0501N052 3.8 5 KFCEH0501N051 2.3 208v 3 240v KFCEH0401N03 HEATER PART NO. kW ACCESSORY ELECTRIC HEATER ELECTRICAL DATA FX4D HEATER ELECTRICAL DATA FACTORY--INSTALLED HEATER OPTIONS* MODEL FX4DNF * 019 5 025 5 031 8 037 10 043 10 049 10 061 10, 15 For field---installed heater/fan coil combinations, see Accessory Electric Heaters. * HEATER kW PHASE 5 8 9 10 15 15 18 20 24 30 1 1 1/3 1 1 3 3 1 1/3 1/3 FUSE QTY/SIZE — — — — 2/30–2/60 — — 4/60 6/60 6/60 CKT BKR* QTY/SIZE 1/60 1/60 — 1/60 2/60 — — 2/60 — — All circuit breakers are 2 pole. When using units with 20--, 24--, and 30--kW electric heaters, maintain a 1--in. (25 mm) clearance from combustible materials to discharge plenum and ductwork and maintain a distance of 36 in. (914mm) from the unit. Use an accessory downflow base to maintain proper clearance on downflow installations. Use flexible connectors between ductwork and unit to prevent transmission of vibration. When electric heater is installed, use heat resistant material for flexible connector between ductwork and unit at discharge connection. Ductwork passing through unconditioned space must be insulated and covered with vapor barrier ACCESSORIES 1. ITEM Disconnect Kit 2. Downflow Base Kit 3. Downflow Conversion Kit { 4. 5. 6. Downflow/Horizontal Conversion Gasket Kit Horizontal Water Management Kit (25 pack) } Single--- Point Wiring Kit 7. Filter Kit (12 Pack) 8. 9. 10. Fan Coil Filter Cabinet (Fan Coil Filter Media) PVC Condensate Trap Kit (50 pack) Air Cleaner 240--- volt Conversion Kit ACCESSORY PART NO.* KFADK0201DSC KFACB0201CFB KFACB0301CFB KFACB0401CFB KFADC0201SLP KFADC0401ACL KFAHD0101SLP KFAHC0125AAA KFASP0101SPK KFAFK0112SML KFAFK0212MED KFAFK0312LRG KFAFK0412XXL FNCCABCC0014 (FILXXFNC0014) FNCCABCC0017 (FILXXFNC0017) FNCCABCC0021 (FILXXFNC0021) FNCCABCC0024 (FILXXFNC0024) KFAET0150ETK KEAVC0201240 * Factory authorized and listed, field---installed. { KFAHD0101SLP must also be purchased for downflow applications. } KFAHD0101SLP must also be purchased for downflow or horizontal applications. 15 FAN COIL SIZE USED WITH Cooling controls and heaters 3--- through 10--- kW 019, 025 031, 037, 043 049, 061 Slope Coil Units — 019, 024, 031 A--- Coil Units — 037, 043, 049, 061 All All Only with 15--- and 20--- kW Fused Heaters NA 019, 025 031 037, 043 049, 061 NA 019, 025 031, 037, 043 049, 061 All All FX4D ELECTRIC HEATER INTERNAL PROTECTION FX4D ACCESSORY KITS DESCRIPTION SUGGESTED AND REQUIRED USE 1. Disconnect Kit The kit is used to disconnect electrical power to the fan coil so service or maintenance may be performed safely. SUGGESTED USE: Units for 3-- through 10--kW electric resistance heaters and cooling controls. 2. Downflow Base Kit This kit is designed to provide a 1--in. minimum clearance between unit discharge plenum, ductwork, and combustible materials. It also provides a gap--free seal with the floor. REQUIRED USE: This kit must be used whenever fan coils are used in downflow applications. 3. Downflow Conversion Kit Fan coils are shipped from the factory for upflow or horizontal--left applications. Downflow conversion kits provide proper condensate water drainage and support for the coil when used in downflow applications. Separate kits are available for slope coils and A--coils. REQUIRED USE: This kit must be used whenever fan coils are used in downflow applications. 4. Downflow/Horizontal Conversion Gasket Kit This kit provides the proper gasketing of units when applied in either a downflow or horizontal application. REQUIRED USE: Fan coils in either downflow or horizontal applications. 5. Horizontal Applications -- Water Management Kit This kit provides proper installation of fan coils under conditions of high static pressure and high relative humidity. SUGGESTED USE: All fan coils. 6. Single Point Wiring Kit The single point wiring kit acts as a jumper between L1 and L3 lugs, and between the L2 and L4 lugs. This allows the installer to run two heavy--gauge, high--voltage wires into the fan coil rather than 4 light--gauge, high--voltage wires. SUGGESTED USE: Fan coils with 15-- and 20--kW fused heaters only. 7. Filter Kit (12 pack) The kit consists of 12 fan coil framed filters. These filters collect large dust particles from the return air entering the fan coil and prevents them from collecting on the coil. This process helps to keep the coil clean, which increases heat transfer and, in turn, the efficiency of the system. SUGGESTED USE: To replace filters in fan coils. REQUIRED USE: All units unless a filter grille is used. 8. Fan Coil Filter Cabinet This cabinet is mounted to the fan coil on the return air end and designed to slip over the outer fan coil casing. The cabinets are insulated using the same insulation as production fan coils. They are designed for the removal of particulates from indoor air using FILXXFNC00(14, 17, 21, 24) media filter cartridges. These fan coil media filter cartridge kits are designed for the removal of particles from indoor air. The cartridge is installed in the return air duct next to the air handler or further upstream. SUGGESTED USE: All fan coils. 9. Condensate Drain Trap Kit This kit consists of 50 PVC condensate traps. Each trap is pre--formed and ready for field installation. This deep trap helps the system make and hold proper condensate flow even during blower initiation. SUGGESTED USE: All fan coils. 10. Air Cleaner 240--volt Conversion Kit The AIRA electronic air cleaner comes ready for 115--v operation. REQUIRED USE: This kit is required when running 240--volt circuit to air cleaner. Edition Date: 01/10 Catalog No: FX4D---01PD Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Replaces: NEW Copyright 2010 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Printed in U.S.A. 16
© Copyright 2024 Paperzz