CHEMICAL PROCESS EQUIPMENT CHEMICAL INJECTORS • Unique aspirator tip design on injector disperses chemical evenly into process stream and away from pipe walls • Designed to be mounted in any orientation • Check Valve in injectors eliminates backflow CHEMICAL INJECTORS • Injectors are ideal for high pressure applications up to 6000 psig • Standard materials available in 316 SS, CPVC & Hastelloy C 276 CHEMICAL INJECTORS (CONT.) • Model KINJ supplied standard with 1/2" NPT or 3/4” NPT process connections • Model KINJM supplied standard with 1/8" NPT or 1/4" NPT process connections • Flanged models available upon request CHEMICAL INJECTORS (CONT.) • Ball check material is ceramic in Hastelloy C-276 and CPVC models • Ball check spring material in 316 S.S. and CPVC models is Inconel. Ball check spring material in Hastelloy Injectors is Hastelloy. • "Cracking Pressure" to achieve flow through injector is less than 1 psig RETRACTABLE INJECTOR • Model KRINJ supplied standard with 1/2” NPT chemical feed port and 3/4” NPT process connection • Ball Valve assembly isolates pipeline from injector assembly when injection is not required • Compression seal holds the assembly from back pressure RETRACTABLE INJECTOR • Safety line prevents the injector assembly from being completely withdrawn and protects against blowout • Retractable injectors are ideal for applications up to 150 psig CALIBRATION GAUGES AccuRate Precision on Pump Setting Gauge THE ONE MINUTE TEST: To check the pumping rate of a chemical metering pump, isolate the chemical in the tank from the calibration gauge. Keep the isolating valve closed and observe the number of marks the fluid level passes in one minute. This will give you the actual chemical pump rate. If the rate is not the one desired, make an adjustment to the chemical pump feed rate and conduct as many one minute tests as is necessary to set the chemical pump rate to the rate desired. AccuRate PUMP SETTING GAUGE • Precision borosilicate glass sight tube delivers precision rate calibration to .0025% • Will calibrate pump rates up to 1095 gallons per day and 4140 liters per day. Clear polycarbonate shield for impact resistance is standard on all models AccuRate PUMP SETTING GAUGE • Five (5) scale options are available: • Gallons by volume (USG) & ML by volume • Gallons per day (GPD) & ML by volume • Gallons per hour (GPH) & ML by volume • Liters per day (LPD) & ML by volume • Liters per hour (LPH) & ML by volume •Fluorocarbon, Buna-N, Aflas, Teflon and Ethylene Propylene o-ring seals are standard. Other elastomers are available. AccuRate PUMP SETTING GAUGE • Tubing connector assembly on top of unit is standard on all models • Drain holes in lower end plate eliminate condensation build-up in protective shield CHOOSING THE CORRECT SIZE 30000 SERIES (old style)PUMP SETTING GAUGE • Maximum pressure is static head pressure (KENCO recommends a polycarbonate tubular shield or expanded metal shield if there is any pressure present in system). • Glass Gauge Cylinder is standard. Plastic tubing may be substituted. 30000 SERIES (old style)PUMP SETTING GAUGE • Fluorocarbon, Buna-N, Aflas, Teflon and Ethylene Propylene o-ring seals are standard. Other elastomers are available. • Gauges are available with (6) standard options on scale calibration units (GPH, LPH, GPD, LPD, GBV, & LBV). 30000 SERIES (old style)PUMP SETTING GAUGE • Nameplate on lower end plate will call out the scale units. • Gauge glass repair kits include calibrated rod to insure gauge accuracy. CALIBRATION POTS • Design utilizes a tank with shielded tubular gauge for maximum protection from glass breakage. • Provide a means for accurately checking the feed rates of a chemical metering pump. CALIBRATION POTS • Manufactured in PVC, Carbon Steel and 316 Stainless Steel as standard materials. • Individually hand calibrated to assure maximum accuracy. • Customization is always an option, give us your design criteria and we will design a gauge to fit your needs and specifications CHOOSING THE CORRECT SIZE DDC DRAW DOWN CYLINDERS • Dual Scale: • Total gauge volume in millimeters • Gallons per Hour or Liters per Hour scale for a one minute test of calibration to determine flow rate • Mylar laminated scales are protected from attack by harsh chemicals DDC DRAW DOWN CYLINDERS • Available in capacities ranging from 60 ML up to 10,000 ML • Models with threaded NPT connections on both ends or models with removable slip-on top caps available • Lightweight and extremely easy to handle 5700, 7000 & 17000INJECTION RATE GAUGES The 5700, 7000, & 17000 Rate Gauges provide a visual means for checking the contents of a bulk tank and a means for checking the injection rate of a chemical metering pump. The shield can be custom calibrated to read tank volume or any other calibration. 929 SERIES PUMP SETTING GAUGE This series of gauges provides a means for checking the pumping rate of any chemical pump under actual pumping conditions in one minute. The gauge mounts in the pump's suction line between the reservoir tank and the pump. It provides a visual gauge showing the liquid level in the reservoir in addition to a rapid means for setting the pump. The maximum pump rate for the 929 Series is 10 gallons per day, with each mark on the scale representing 1 quart per 24 hours. DRUM GAUGES KENCO drum gauges are used to measure the liquid level inventory in horizontal 55 gallon chemical storage tanks. In addition, several models come complete with a test valve to set the injection rate of a chemical metering pump. 596 599 779 779-KS 787 810 779-PB VENTED DRUM GAUGES • Volume Scale is calibrated in gallons and liters • Chemical injection rate scale is calibrated in Quarts/24 Hours and Liters/24 Hours • Models available to accommodate diaphragm operated pumps DRUM GAUGES • Can handle pump rates up to 20 gallons per day or 75 liters per day • Installs easily in 3/4" NPT outlet of drum head
© Copyright 2026 Paperzz