Exane® 125 - RSCC Wire and Cable

Exane 125
®
Drilling Rig and
Commercial Marine Cable
Over 20 Years
of Superior
Perfomance On
Oil Rigs Around
The World
•Certified as Type “P” per
IEEE-45 STD 1998
•Listed by UL for Marine
Applications to STD UL 1309
•Meets IEC 332-3 Category A
Flame Test
•Approved by ABS, DNV,
Lloyds, USCG and Canadian
Coast Guard
•CSA listed to C22.2 No. 245
•ITS listed to the performance
requirements of IEC 92-3
Engineered Wire & Cable for Demanding Applications
• ITS listed to the performance
requirements of IEC 60092-353
EXANE® 125
The Ideal Solution for
Harsh Oil Rig Environments Found
Anywhere in the World
• Excellent Electrical Properties
•Wide Size Range (#18 AWG-1111 MCM)
(1.0 mm2-560 mm2)
• Highly Flame Retardant (VW-1, IEEE-383,
IEEE1202, FT-4, IEC 332-3 Cat. A)
•Single and Multiconductor — Up to 91 Conductors
• Flexible Stranding — Tinned Copper
Conductors — ASTM B33, B8 and B172
• Excellent Moisture Resistance
• Irradiation Crosslinked Polyolefin (Exane )
Insulation
• Superior Abrasion, Crush & High Temperature
Cut Thru Resistance
•Free Stripping without Separator over Strand
• Easy to Handle During Installation
•High Energy Irradiation Process. Produces Thermoset
Insulation Able to Withstand Thermal Overloads
• Resistant to Oilfield Drilling Muds
• Heavy Duty Arctic Grade Neoprene Jacket per
ICEA S-95-658
Note: Special wire and cable constructions available — check with factory. Product available with
blue jackets to indicate intrinsically safe circuit.
• Superior Oil and Chemical Resistance
®
• Wide Temperature Range -55°C to 125°C
• Passes Cold Bend at -55°C, and Cold Impact at
-40°C
1
EXANE® 125
EXANE® Product Line
A Unique Combination of Features.
Wire and Cable with Wide Range of World Wide Approvals.
•ITS Listed to IEEE-45-1998 & IEEE 1580-2001,
Type P
• Approved by ABS
• Listed — UL 1309 Marine Shipboard Cable
• Approved by Lloyd’s U.K., Register of Shipping
• Listed — CSA
C22.2 No. 245 Marine Shipboard Cable
• Approved by DNV
• Approved by NVE
• ITS Type Approved in accordance with IEC 92-3
and IEC 60092-353
• Approved by Korean Register of Shipping
• Meets IEC 332-3 Cat. A Flame Test
• Accepted by U.S. Coast Guard
• Meets IEEE 1202 Vertical Cable Tray Flame Test
• Meets requirements of 46 CFR Parts 110 & 111
• Listed by UL as Type CWCMC for cables with
continuously welded and corrugated aluminum
armor in accordance with UL 1309.
• Accepted by Canadian Coast Guard
Engineering Information
Ampacity Ratings Based on the
Following*
•95°C IEC 92-3 Ampacity @ 45°C Ambient in
Free Air
Electrical Values
#18 AWG Pairs and Triads
•Capacitance — pf/ft = 36
•Inductance — milli-henries/1000 ft = .126
•100°C IEEE-45 STD 1998 @ 45°C Ambient in
Free Air
•Resistance — Ohms/1000 ft @ 20°C = 6.22
•125°C ICEA Pub. P-46-426 @ 45°C Ambient in
Free Air
*Contact factory for specific installation conditions
#16 AWG Pairs and Triads
•Capacitance — pf/ft = 39
•Inductance — milli-henries/1000 ft = .117
Recommended Minimum Dynamic Bend
Radius
•Unarmored 6X Finished Cable Diameter
•Resistance — Ohms/1000 ft @ 20°C = 4.82
#14 AWG Pairs
•Armored and Armored and Sheathed Cable 8X
Finished Cable Diameter
*Contact factory for specific installation conditions
•Capacitance — pf/ft = 28
•Inductance — milli-henries/1000 ft = .104
•Resistance — Ohms/1000 ft @ 20°C = 3.05
Standard O.D. Tolerances ± 10%
Soft Metric Diameter Conversion Factor —
Inches to Millimeters: Multiply by 25.4
2
* Contact factory for special electrical requirements.
EXANE® 125
Oil Rig/Commercial Marine Cable
Single Conductor Power
RSCC DAA 1048B
Multi-Conductor Power
RSCC DAC 1048C
Conductor
Flexible stranded,
tin-coated copper
(various strandings)
Conductor
Flexible stranded,
tin-coated copper
(various strandings)
Insulation
Crosslinked
Polyolefin
Insulation
Crosslinked
Polyolefin
Inner Jacket
Neoprene
Armor
Armor
Outer Sheath
Neoprene
Sheath
Neoprene
600 & 2000 Volt
Single Conductor Power, Unarmored or Armored and
Sheathed.
600 Volt
Multi-Conductor Power Cable, Unarmored or Armored
and Sheathed.
Conductor:
Flexible, Annealed, Tinned Copper per ASTM B33, B8
and B172
Conductors:
Flexible, Annealed, Tinned Copper per ASTM B33, B8
and B172
Insulation: Exane®-125
Crosslinked Polyolefin 125°C
(Colors as Required)
Insulation: Exane®-125
Crosslinked Polyolefin 125°C
Color Code:
IEEE-45, UL1309 or as Specified by Customer
Armor:
Bronze, Tinned Copper or Aluminum Braid
Fillers:
When Required, Flame Retardant and Non-Hygroscopic
Sheath:
Heavy Duty Arctic Neoprene
Binder Tape:
Non-Hygroscopic and Non-Wicking
Inner Jacket:
Heavy Duty Arctic Neoprene
Armor:
Bronze, Tinned Copper or Aluminum Braid
Outer Sheath:
Heavy Duty Arctic Neoprene
3
EXANE® 125
Oil Rig/Commercial Marine Cable
Multi-Conductor Control
RSCC DAC 1048C
Insulation
Crosslinked
Polyolefin
Multi-Conductor Instrumentation
RSCC DAC 1048C
Conductor
Flexible stranded,
tin-coated copper
(various strandings)
Conductor
Flexible stranded,
tin-coated copper
(various strandings)
Insulation
Crosslinked
Polyolefin
Binder Tape
Drain Wires
Tin-coated copper
Inner Jacket
Neoprene
Shield Tapes
Armor
Inner Jacket
Neoprene
Outer Sheath
Neoprene
Armor
Outer Sheath
Neoprene
600 Volt
Multi-Conductor Control Cable, Unarmored or
Armored and Sheathed
600 Volt
Multi-Shielded Pairs or Triples with Overall Shield,
Unarmored or Armored and Sheathed
Conductors:
Annealed, Tinned Copper per ASTM B33, B8 and
B172
Conductors:
Annealed, Tinned Copper per ASTM B33, B8 and B172
Insulation: Exane®-125
Crosslinked Polyolefin 125°C
Insulation: Exane®-125
Crosslinked Polyolefin 125°C
Pair or Triple Assembly:
Two or Three Conductors Twisted with a Tin-Coated
Copper Drain Wire, a Helically Applied Aluminum/
Ployester Laminated Tape Shield
Color Code:
IEEE-45, UL1309 or as Specified by Customer
Fillers:
When Required, Flame Retardant and Non-Hygroscopic
Cabling:
Required Number of Pairs or Triples Cabled Together
Binder Tape:
Non-Hygroscopic and Non-Wicking
Color Code:
IEEE-45, UL1309 or as Specified by Customer
Inner Jacket:
Heavy Duty Arctic Neoprene
Fillers:
When Required, Flame Retardant and Non-Hygroscopic
Armor:
Bronze, Tinned Copper or Aluminum Braid
Overall Shield System:
Helically Applied Aluminum/Polyester Laminated Tape
Shield in Continuous Contact with Tin-Coated Copper
Drain Wire
Outer Sheath:
Heavy Duty Arctic Neoprene
Inner Jacket:
Heavy Duty Arctic Neoprene
Armor:
Bronze, Tinned Copper or Aluminum Braid
Outer Sheath:
Heavy Duty Arctic Neoprene
4
EXANE® 125
One Conductor Wire: 600 Volt
Armored and
Unarmored
Armored – “B”*
Sheathed “BN”*
NominalNominal
Conductor Overall Weight NominalWeightNominalWeight
Product Diameter DiameterLbs per DiameterLbs perDiameterLbs per
Size
Number*Inches InchesM FT InchesM FTInchesM FT
Ampacity**
ICEA IEEE-45IEC
125°C 100°C 95°C
2201C22-600V 0.030
0.090
6
14
N/A
11
2001C20-600V 0.038
0.098
8
17
12
15
1801C18-600V 0.047
0.107
11
22
16
20
1601C16-600V 0.054
0.114
13
25
23
23
1401C14-600V 0.067
0.127
18
39
37
30
1201C12-600V 0.086
0.146
27
49
45
36
1001C10-600V 0.123
0.183
45
68
58
52
8
01C8-600V
0.138 0.231 65 0.2861070.410156
90
72
64
6
01C6-600V
0.190 0.280101 0.3351500.459208
126
96
87
5
01C5-600V
0.240 0.330149 0.3851970.513263
158
109
112
4
01C4-600V
0.260 0.350170 0.4052250.533290
176
128
122
3
01C3-600V
0.285 0.375195 0.4342700.550337
195
146
137
2
01C2-600V
0.320 0.410233 0.4653050.593380
217
169
153
1
01C1-600V
0.390 0.500343 0.5504260.678525
281
194
197
1/0
01C1/0-600V
0.435 0.545408 0.6004980.728603
319
227
224
2/0
01C2/0-600V
0.480 0.590481 0.6455020.773675
354
262
248
3/0
01C3/0-600V
0.550 0.660653 0.7157050.883930
437
300
304
Note: #18 AWG through #3/0 AWG also available in 2000V rated thicknesses when required.
*Exane-125® Ordering Part Number
• Unarmored – use product number. Example: 01C262-600V.
• Armored only – add the letter B. Example: 01C262-600VB.
• Armored and Sheathed – add the letters BN.
Example: 01C262-600V BN.
**Ampacity Ratings Based on the Following
• 95°C IEC 92-3 Ampacity in Free Air @ 45°C Ambient
• 100°C IEEE-45 STD 1998 in Free Air @ 45°C Ambient
• 125°C ICEA Pub. P-46-426 in Free Air @ 45°C Ambient
**Contact Factory for sizes 4/0 AWG to 1111KCMIL.
One Conductor Power Cable: 2000 Volts (Heavy Duty)
Armored and
Unarmored
Armored – “B”*
Sheathed “BN”*
NominalNominal
Conductor Overall Weight NominalWeightNominalWeight
Product Diameter DiameterLbs per DiameterLbs perDiameterLbs per
Size
Number*Inches InchesM FT InchesM FTInchesM FT
Ampacity**
ICEA IEEE-45IEC
125°C 100°C 95°C
4/0
01C4/0-HD
0.580 0.790852 0.8459951.0131139
262
01C262-HD
0.652 0.862 982 0.91711151.0851303
313 01C313-HD
0.720
0.930
1152
0.985 1296 1.163
1507
373 01C373-HD
0.770
0.980
1354
1.035 1520 1.203 1718
444 01C444-HD
0.845
1.055
1597
1.110 1785 1.280 1995
535 01C535-HD
0.915
1.165
1935
1.220
2194 1.428 2432
646
01C646-HD
1.030 1.2702264 1.3252525 1.5332788
777
01C777-HD
1.120 1.3602734 1.4152960 1.6433304
1111
01C1111-HD
1.340 1.5803807 1.63540051.8934553
495
550
617
692
772
871
979
1101
1374
*Exane-125® Ordering Part Number
• Unarmored – use product number. Example: 01C262-HD.
• Armored only – add the letter B. Example: 01C262-HDB.
• Armored and Sheathed – add the letters BN.
Example: 01C262-HD BN.
351
407
455
516
588
662
731
822
1025
345
383
427
477
532
597
672
754
943
**Ampacity Ratings Based on the Following
• 95°C IEC 92-3 Ampacity in Free Air @ 45°C Ambient
• 100°C IEEE-45 STD 1998 in Free Air @ 45°C Ambient
• 125°C ICEA Pub. P-46-426 in Free Air @ 45°C Ambient
Contact factory for specific environmental conditions.
5
EXANE® 125
One Conductor Wire: 2000 Volt (Standard)
Armored and
Unarmored
Armored – “B”*
Sheathed “BN”*
NominalNominal
Conductor Overall Weight Nominal Weight Nominal Weight
Product
Diameter Diameter Lbs per Diameter Lbs per Diameter Lbs per
Size
Number*
Inches
Inches
M FT
Inches
M FT
Inches
M FT
Ampacity**
ICEA IEEE-45IEC
125°C 100°C 95°C
18
01C18-2KV
0.047
0.137
22
16
20
16
01C16-2KV
0.054
0.144
25
23
23
14
01C14-2KV
0.067
0.157
39
37
30
12
01C12-2KV
0.086
0.176
49
45
36
10
01C10-2KV
0.123
0.213
68
58
52
801C8-2KV0.1380.248 70 0.3031110.406150
90
72
64
601C6-2KV0.1900.300110 0.3551590.459205
126
96
87
501C5-2KV0.2400.350157 0.4052140.509265
158
109
112
401C4-2KV0.2600.370178 0.4252390.529292
176
128
122
301C3-2KV0.2850.395204 0.4502680.578338
195
146
137
201C2-2KV0.3200.430242 0.4853160.609388
217
169
153
101C1-2KV0.3900.520355 0.5754400.703528
281
194
197
1/0
01C1/0-2KV
0.4350.565428 0.6205250.748619
319
227
224
2/0
01C2/0-2KV
0.4800.610496 0.6655950.793695
354
262
248
3/0
01C3/0-2KV
0.5500.680668 0.7357800.901925
437
300
304
4/0
01C4/0-2KV
0.5800.710785 0.7659020.9311053
495
351
345
262
01C262-2KV0.652 0.802 946 0.85710751.0251244
550
407
383
313
01C313-2KV0.720 0.8701117 0.92512561.0951438
617
455
427
373
01C373-2KV0.770 0.9201319 0.97514701.1451661
692
516
477
444
01C444-2KV0.845 0.9951554 1.05017151.2201919
772
588
532
535
01C535-2KV0.915 1.0951882 1.15020571.3202258
871
662
597
646
01C646-2KV1.030 1.2102199 1.26523921.4352635
979
731
672
777
01C777-2KV1.120 1.3002686 1.35528941.5253154
1101
822
754
1111
01C1111-2KV
1.340 1.5603781 1.61540311.8454455
1374
1025
943
*Exane-125® Ordering Part Number
• Unarmored – use product number. Example: 01C262-2KV.
• Armored only – add the letter B. Example: 01C262-2KVB.
• Armored and Sheathed – add the letters BN.
Example: 01C262-2KV BN.
*** 4/0 AWG and larger are per UL1309/CSA C22.2 No. 245
18 AWG to 3/0 AWG are in accordance with IEEE 45 and
UL 1309/CSA C22.2 No. 245.
6
**Ampacity Ratings Based on the Following
• 95°C IEC 92-3 Ampacity in Free Air @ 45°C Ambient
• 100°C IEEE-45 STD 1998 in Free Air @ 45°C Ambient
• 125°C ICEA Pub. P-46-426 in Free Air @ 45°C Ambient
Contact factory for specific environmental conditions.
EXANE® 125
Two Conductor Power Cable: 600 Volt
Armored and
Unarmored
Armored – “B”*
Sheathed “BN”*
Product
Size
Number*
16
14
12
10
8
6
5
4
3
2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
02C16
02C14
02C12
02C10
02C8
02C6
02C5
02C4
02C3
02C2
02C1
02C1/0
02C2/0
02C3/0
02C4/0
02C262
02C313
02C373
02C444
02C535
02C646
02C777
Nominal Weight NominalWeight NominalWeight Ampacity**
Diameter Lbs per Diameter Lbs per Diameter Lbs per ICEA IEEE-45IEC
Inches
M FT
Inches
M FT
Inches
M FT 125°C100°C 95°C
0.352
0.380
0.416
0.490
0.590
0.688
0.785
0.868
0.918
0.988
1.153
1.258
1.348
1.560
1.695
1.792
1.968
2.110
2.250
2.490
2.698
2.905
70
80
111
156
217
316
409
550
583
682
923
1087
1271
1870
2220
2600
3100
3605
4135
4950
5860
7010
0.407
0.435
0.480
0.575
0.645
0.743
0.840
0.943
0.973
1.043
1.208
1.313
1.403
1.615
1.750
1.847
2.023
2.165
2.305
2.545
2.753
2.960
132
148
173
204
320
430
515
655
740
845
1115
1295
1490
2130
2506
2896
3430
3960
4520
5360
6330
7505
0.535
0.560
0.605
0.670
0.775
0.911
1.020
1.090
1.140
1.215
1.425
1.525
1.635
1.820
1.985
2.145
2.305
2.410
2.570
2.840
3.065
3.195
190
214
252
320
440
573
687
828
921
1059
1392
1598
1850
2600
2932
3269
4000
4650
5250
6150
7175
8400
22
33
44
64
77
111
146
153
180
196
245
278
309
382
432
481
539
599
669
741
860
968
19
31
40
49
64
85
101
110
132
149
174
199
242
265
307
358
391
442
504
566
632
684
19
26
31
44
54
74
95
104
114
130
167
190
211
258
293
325
363
405
452
508
571
641
Three Conductor Power Cable: 600 Volt
Armored and
Unarmored
Armored – “B”*
Sheathed “BN”*
Product
Size
Number*
16
14
12
10
8
6
5
4
3
2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
03C16
03C14
03C12
03C10
03C8
03C6
03C5
03C4
03C3
03C2
03C1
03C1/0
03C2/0
03C3/0
03C4/0
03C262
03C313
03C373
03C444
03C535
03C646
03C777
Nominal Weight NominalWeight NominalWeight Ampacity**
Diameter Lbs per Diameter Lbs per Diameter Lbs per ICEA IEEE-45IEC
Inches
M FT
Inches
M FT
Inches
M FT 125°C100°C 95°C
0.370
0.398
0.440
0.520
0.625
0.735
0.880
0.925
0.975
1.050
1.246
1.340
1.480
1.650
1.810
1.940
2.090
2.195
2.395
2.660
2.905
3.040
84
103
135
202
280
405
570
700
761
919
1333
1552
1867
2487
3020
3499
4103
4743 5552
6824
8016
9382
0.425
0.453
0.495
0.575
0.680
0.790
0.935
0.976
1.030
1.105
1.300
1.395
1.535
1.705
1.865
1.995
2.145
2.250
2.450
2.715
2.960
3.095
142
165
202
280
390
539
753
853
949
1006
1495
1857
2141
2741
3282
3824
4385
5081
6050
7410
8486
9883
*Exane-125® Ordering Part Number
• Unarmored – use product number. Example: 03C4.
• Armored only – add the letter B. Example: 03C4B.
• Armored and Sheathed – add the letters BN.
Example: 03C4BN.
0.550
0.580
0.620
0.700
0.849
0.955
1.105
1.144
1.200
1.275
1.500
1.625
1.765
1.965
2.123
2.285
2.435
2.540
2.745
3.005
3.250
3.850
212
245
285
375
536
697
913
1043
1125
1314
1769
2138
2500
3205
3801
4452
5077
5734
6758
8190
9353
10790
18
28
37
49
63
91
120
126
148
161
202
229
254
313
451
395
442
492
549
608
714
803
16
25
31
41
52
70
82
92
108
122
143
164
188
218
252
294
321
361
411
465
516
562
16
21
25
37
45
61
78
86
96
107
138
156
173
213
241
268
299
334
372
418
470
528
**Ampacity Ratings Based on the Following
• 95°C IEC Ampacity Regulations in Free Air @ 45°C Ambient
• 100°C IEEE-45 STD 1998 in Free Air @ 45°C Ambient
• 125°C ICEA Pub. P-46-426 in Free Air @ 45°C Ambient
Contact factory for specific environmental conditions.
7
EXANE® 125
Four Conductor Power Cable: 600 Volt
Armored and
Unarmored
Armored – “B”*
Sheathed “BN”*
Product
Size
Number*
16
14
12
10
8
6
5
4
3
2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
04C16
04C14
04C12
04C10
04C8
04C6
04C5
04C4
04C3
04C2
04C1
04C1/0
04C2/0
04C3/0
04C4/0
04C262
04C313
04C373
04C444
04C535
04C646
04C777
Nominal Weight NominalWeight NominalWeight Ampacity**
Diameter Lbs per Diameter Lbs per Diameter Lbs per ICEA IEEE-45IEC
Inches
M FT
Inches
M FT
Inches
M FT 125°C100°C 95°C
0.400
102
0.455
162
0.575
235
15
13
13
0.430
127
0.485
198
0.613
271
22
20
17
0.475
158
0.530
238
0.659
329
29
25
20
0.565
260
0.620
334
0.750
445
39
33
29
0.681
355
0.736
475
0.904
623
50
42
36
0.805
540
0.860
672
1.030
856
73
56
49
0.965
750
1.020
915
1.090 1115
96
66
63
1.020
927
1.067 1060
1.235 1277
101
74
68
1.080
1080
1.135 1162
1.300 1389
118
86
76
1.160
1155
1.215 1345
1.425 1683
128
98
86
1.376
1722
1.431 1875
1.659 2325
161
114
110
1.482
2058
1.537
2200
1.765
2739
182
131
125
1.650
2471
1.705
2643
1.935
3245
203
150
139
1.820
3238
1.875
3515
2.135
4096
250
174
170
1.995
3973
2.050
4115
2.335
4977
283
202
193
2.145
4418
2.200
4795
2.490
5450
315
235
214
2.340
5433
2.395
5680
2.685
6485
353
257
239
2.460
6276
2.515
6680
2.810
7417
393
289
267
2.650
7503
2.705
7820
2.995
8622
438
329
298
2.940
9159
2.995
9660
3.285
10484 504
372
334
3.220
10654
3.275
11193
3.565
12270 567
412
376
3.375
12730
3.430
13290
3.720
14490 638
450
423
Five Conductor Power Cable: 600 Volt
Armored and
Unarmored
Armored – “B”*
Sheathed “BN”*
Product
Size
Number*
16
14
12
10
8
6
5
4
3
2
1
1/0
2/0
3/0
4/0
05C16
05C14
05C12
05C10
05C8
05C6
05C5
05C4
05C3
05C2
05C1
05C1/0
05C2/0
05C3/0
05C4/0
Nominal Weight NominalWeight NominalWeight Ampacity**
Diameter Lbs per Diameter Lbs per Diameter Lbs per ICEA IEEE-45IEC
Inches
M FT
Inches
M FT
Inches
M FT 125°C100°C 95°C
0.440
118
0.495
192
0.620
265
15
13
13
0.467
145
0.522
225
0.650
315
22
20
17
0.525
190
0.580
278
0.710
367
29
25
20
0.620
308
0.675
393
0.805
538
39
33
29
0.748
451
0.815
550
0.980
713
50
42
36
0.925
698
0.980
830
1.150 1011
73
56
49
1.060
960
1.115 1140
1.285 1350
73
66
63
1.115
1116
1.170 1240
1.340 1505
101
74
68
1.185
1270
1.240 1470
1.450 1775
118
86
76
1.275
1477
1.335 1630
1.545 1984
128
98
86
1.545
2148
1.605 2425
1.835 2806
161
114
110
1.700
2514
1.755
2800
2.015
3266
182
131
125
1.825
3005
1.880
3305
2.140
3898
203
150
139
2.040
4046
1.095
4386
2.385
5013
250
174
170
2.210
4682
2.265
5085
2.550
5899
283
202
193
**Ampacity Ratings Based on the Following
• 95°C IEC Ampacity Regulations in Free Air @ 45°C Ambient
• 100°C IEEE-45 STD 1998 in Free Air @ 45°C Ambient
• 125°C ICEA Pub. P-46-426 in Free Air @ 45°C Ambient
*Exane-125® Ordering Part Number
• Unarmored – use product number. Example: 05C2.
• Armored only – add the letter B. Example: 05C2B.
• Armored and Sheathed – add the letters BN.
Example: 05C2BN.
Contact factory for specific environmental conditions.
8
EXANE® 125
#16 AWG Multi-Conductor Control Cable: 600 Volt
Armored and
Unarmored
Armored – “B”*
Sheathed “BN”*
Number
Nominal
of
Product Diameter
Cond. Number* Inches
4
5
7
8
10
16
20
24
37
44
60
91
04C16
05C16
07C16
08C16
10C16
16C16
20C16
24C16
37C16
44C16
60C16
91C16
0.400
0.440
0.475
0.550
0.585
0.670
0.735
0.812
0.970
1.085
1.194
1.460
Weight
Lbs per
M FT
95
115
145
181
213
307
350
443
668
735
1042
1470
Nominal
Diameter
Inches
0.455
0.495
0.530
0.605
0.640
0.725
0.790
0.875
1.025
1.140
1.249
1.515
Weight
Lbs per
M FT
162
192
225
245
300
395
475
575
785
915
1160
1750
Nominal
Diameter
Inches
0.590
0.620
0.655
0.733
0.770
0.855
0.960
1.045
1.195
1.315
1.457
1.745
Weight Ampacity**
Lbs per ICEA IEEE-45IEC
M FT 125°C100°C 95°C
235
15
13
13
265
15
13
13
300
15
11
11
371
13
11
11
406
9
8
8
545
9
8
8
635
9
8
8
755
8
7
7
1033
7
6
6
1125
6
6
6
1514
6
6
6
2119
6
6
6
#14 AWG Multi-Conductor Control Cable: 600 Volt
Armored and
Unarmored
Armored – “B”*
Sheathed “BN”*
Number
Nominal
of
Product Diameter
Cond. Number* Inches
4
5
6
7
10
12
14
20
24
30
37
44
91
04C14
05C14
06C14
07C14
10C14
12C14
14C14
20C14
24C14
30C14
37C14
44C14
91C14
0.430
0.475
0.515
0.515
0.636
0.660
0.695
0.810
0.930
0.990
1.060
1.190
1.630
Weight
Lbs per
M FT
115
158
179
199
2840
290
364
495
627
695
877
990
1980
Nominal
Diameter
Inches
0.485
0.522
0.560
0.560
0.691
0.715
0.750
0.865
0.985
1.045
1.115
1.245
1.685
Weight
Lbs per
M FT
191
225
250
265
370
400
445
630
745
865
1025
1190
2250
Nominal
Diameter
Inches
0.620
0.650
0.688
0.688
0.819
0.885
0.920
1.025
1.155
1.215
1.280
1.455
1.915
Weight Ampacity**
Lbs per ICEA IEEE-45IEC
M FT 125°C100°C 95°C
275
22
20
17
315
22
20
17
340
22
20
17
366
20
18
15
500
14
13
11
550
14
13
11
600
14
13
11
791
14
13
11
930
13
11
10
1060
13
11
10
1336
11
10
9
1510
10
9
7
2750
10
9
7
#12 AWG Multi-Conductor Control Cable: 600 Volt
Armored and
Unarmored
Armored – “B”
Sheathed “BN”
Number
Nominal
of
Product Diameter
Cond. Number* Inches
4
5
6
10
20
24
37
04C12
05C12
06C12
10C12
20C12
24C12
37C12
0.475
0.525
0.570
0.712
0.950
1.050
1.190
Weight
Lbs per
M FT
155
190
220
389
714
795
1140
Nominal
Diameter
Inches
0.530
0.580
0.625
0.767
1.005
1.105
1.245
Weight
Lbs per
M FT
138
278
320
475
840
970
1340
Nominal
Diameter
Inches
0.665
0.710
0.750
0.935
1.175
1.275
1.453
Weight Ampacity**
Lbs per ICEA IEEE-45IEC
M FT 125°C100°C 95°C
325
30
25
20
370
30
25
20
415
30
25
20
649
19
16
13
1071
19
16
13
1180
17
14
11
1743
15
12
10
**Ampacity Ratings Based on the Following
• 95°C IEC Ampacity Regulations in Free Air @ 45°C Ambient
• 100°C IEEE-45 STD 1998 in Free Air @ 45°C Ambient
• 125°C ICEA Pub. P-46-426 in Free Air @ 45°C Ambient
*Exane-125® Ordering Part Number
• Unarmored – use product number. Example: 04C16.
• Armored only – add the letter B. Example: 04C16B.
• Armored and Sheathed – add the letters BN.
Example: 04C16BN.
Contact factory for specific environmental conditions.
9
EXANE® 125
#18 AWG Instrumentation Cable – Shielded Pairs, Overall Shield: 600 Volts
Armored and
Unarmored
Armored – “B”*
Sheathed “BN”*
Number
of
Product
Pairs
Number*
1
2
3
4
5
7
8
10
12
16
18
24
01P18I/S-OS
02P18I/S-OS
03P18I/S-OS
04P18I/S-OS
05P18I/S-OS
07P18I/S-OS
08P18I/S-OS
10P18I/S-OS
12P18I/S-OS
16P18I/S-OS
18P18I/S-OS
24P18I/S-OS
Nominal
Diameter
Inches
0.340
0.565
0.641
0.694
0.715
0.811
0.950
1.010
1.071
1.179
1.225
1.438
Weight
Lbs per
M FT
68
177
225
268
285
364
444
576
655
767
890
1089
Nominal
Diameter
Inches
0.405
0.625
0.696
0.749
0.770
0.866
1.010
1.065
1.126
1.234
1.280
1.493
Weight
Lbs per
M FT
126
282
335
370
395
500
645
705
798
960
1110
1340
Nominal
Diameter
Inches
0.530
0.795
0.864
0.917
0.928
1.034
1.173
1.233
1.294
1.442
1.495
1.721
Weight
Lbs per
M FT
270
376
454
536
560
656
814
929
998
1194
1285
1688
#16 AWG Instrumentation Cable – Shielded Pairs, Overall Shield: 600 Volts
Armored and
Unarmored
Armored – “B”*
Sheathed “BN”*
Number
of
Product
Pairs
Number*
1
2
3
4
5
7
8
10
12
16
18
24
01P16I/S-OS
02P16I/S-OS
03P16I/S-OS
04P16I/S-OS
05P16I/S-OS
07P16I/S-OS
08P16I/S-OS
10P16I/S-OS
12P16I/S-OS
16P16I/S-OS
18P16I/S-OS
24P16I/S-OS
Nominal
Diameter
Inches
0.360
0.609
0.668
0.685
0.751
0.835
0.972
1.070
1.091
1.206
1.260
1.485
Weight
Lbs per
M FT
70
188
243
285
342
385
543
562
714
895
925
1288
Nominal
Diameter
Inches
0.415
0.664
0.723
0.740
0.797
0.890
1.027
1.183
1.146
1.261
1.315
1.541
Weight
Lbs per
M FT
130
296
353
395
420
540
702
730
820
1097
1170
1410
Nominal
Diameter
Inches
0.545
0.792
0.891
0.908
0.968
1.025
1.205
1.238
1.313
1.460
1.515
1.769
Weight
Lbs per
M FT
201
394
487
538
548
695
943
945
1118
1250
1370
1916
#14 AWG Instrumentation Cable – Shielded Pairs, Overall Shield: 600 Volts
Armored and
Unarmored
Armored – “B”*
Sheathed “BN”*
Number
of
Product
Pairs
Number*
1
2
3
4
5
7
8
10
12
01P14I/S-OS
02P14I/S-OS
03P14I/S-OS
04P14I/S-OS
05P14I/S-OS
07P14I/S-OS
08P14I/S-OS
10P14I/S-OS
12P14I/S-OS
Nominal
Diameter
Inches
0.390
0.658
0.685
0.755
0.815
0.930
1.040
1.090
1.140
Weight
Lbs per
M FT
83
241
250
295
350
480
550
690
755
Nominal
Diameter
Inches
0.445
0.691
0.740
0.810
0.870
0.985
1.095
1.145
1.195
Weight
Lbs per
M FT
148
335
375
425
580
645
750
805
955
*Exane-125® Ordering Part Number
• Unarmored – use product number. Example: 04P14I/S-OS.
• Armored only – add the letter B. Example: 04P14I/S-OS-B.
• Armored and Sheathed – add the letters BN. Example: 04P14I/S-OS-BN.
10
Nominal
Diameter
Inches
0.578
0.830
0.905
0.970
1.032
1.143
1.265
1.285
1.395
Weight
Lbs per
M FT
222
425
520
570
649
812
930
1026
1253
EXANE® 125
#18 AWG Instrumentation Cable –
Shielded Triads, Overall Shield: 600 Volts
Armored and
Unarmored
Armored – “B”*
Sheathed “BN”*
Number
of
Product
Triads
Number*
1
2
3
4
5
7
8
12
01T18I/S-OS
02T18I/S-OS
03T18I/S-OS
04T18I/S-OS
05T18I/S-OS
07T18I/S-OS
08T18I/S-OS
12T18I/S-OS
Nominal
Diameter
Inches
0.360
0.602
0.641
0.708
0.771
0.882
0.998
1.150
Weight
Lbs per
M FT
Nominal
Diameter
Inches
79
160
205
267
304
423
566
710
0.415
0.657
0.696
0.763
0.826
0.937
1.015
1.206
Weight
Lbs per
M FT
144
270
315
390
435
575
660
900
Nominal
Diameter
Inches
0.542
0.780
0.858
0.932
0.988
1.099
1.175
1.435
Weight
Lbs per
M FT
201
355
439
520
586
740
830
1175
*Exane-125® Ordering Part Number
• Unarmored – use product number. Example: 04T18I/S-OS.
• Armored only – add the letter B. Example: 04T18I/S-OS-B.
• Armored and Sheathed – add the letters BN. Example: 04T18I/S-OS-BN.
#16 AWG Instrumentation Cable –
Shielded Triads, Overall Shield: 600 Volts
Armored and
Unarmored
Armored – “B”*
Sheathed “BN”*
Number
of
Product
Triads
Number*
1
3
4
6
7
8
12
01T16I/S-OS
03T16I/S-OS
04T16I/S-OS
06T16I/S-OS
07T16I/S-OS
08T16I/S-OS
12T16I/S-OS
Nominal
Diameter
Inches
0.376
0.674
0.739
0.967
0.967
1.103
1.215
Weight
Lbs per
M FT
129
241
303
538
480
600
817
Nominal
Diameter
Inches
0.431
0.849
0.794
0.976
0.976
1.158
1.270
Weight
Lbs per
M FT
146
335
425
585
635
685
1018
*Exane-125® Ordering Part Number
• Unarmored – use product number. Example: 06T16I/S-OS.
• Armored only – add the letter B. Example: 06T16I/S-OS-B.
• Armored and Sheathed – add the letters BN. Example: 06T16I/S-OS-BN.
11
Nominal
Diameter
Inches
0.554
0.891
0.956
1.149
1.149
1.230
1.472
Weight
Lbs per
M FT
207
483
565
810
810
983
1284
12
Exane VFD Power Cable
®
600V
2KV
2KV (HD)
A Division of RSCC Cable Group
Armor
(Optional)
Jacket
Insulation
Power
Conductor
(X3)
Exane® VFD
Power Cable
• Three Conductor
• Rated 110°C
Sheath
(Optional)
Shield
Ground
Conductors
(X3)
RSCC Type VFD Power Cables are high performance cables,
designed for use in applications where high speed (IGBT Type)
AC drives will be utilized. Type VFD cables are flexible, and
employ an optimized Tinned Copper braid shield with an
Features
Optimized tinned copper braid with
Aluminum/Polyester laminated tape
shielding system provides 100% coverage and an effective electrostatic
shield for isolation of the high
frequency currents and potentials,
and an effective low impedance path
to ground for A.C. drive applications.
High Dielectric Strength Insulation
• Withstands Voltage Spikes (2-3X)
Symmetrical Cable Construction
• 3 Phase & 3 Ground Conductors
• Cancellation of Magnetic Fields
• Lower Ground Conductor Current
Flow
• Reduction in Common Mode Noise
Flexible Cable
• Class I Conductor and Braid Shield
High Crush and Impact Resistance
• Armored and Non-Armored
• Meets UL 2225 (Type MC) with no
Armor
Proven 30 Year Exane® Reliability
• Irradiation Cross-Linked Polyolefin
Insulation
Aluminum/Polyester laminated tape to provide exceptional
shielding characteristics. The unarmored cables are dual listed as
UL Type TC, and Marine Shipboard Cables.
Performance Standards
ITS and UL Listed as Marine
Shipboard
• UL 1309 Type X110
• IEEE 45 & IEEE 1580 Shipboard
• Un-Armored Also UL Type TC
CSA Listed as Marine Ship Board
• CSA C22.2 No 245 Type X110
ITS Listed as Marine Shipboard –
IEC 60092-353
Meets Vertical Tray Flame Tests
• IEEE 1202
• IEC 600332-3 Category A
Meets Cold Temperature
Requirements
• UL and CSA -40°C Cold
Impact Rated
• -55° C Cold Bend
Armored and Sheathed Cables
Suitable for Class I, Div. 1 & Zone 1
Unarmored Cable Suitable for Class
I, Div. 2 & Zone 2
13
• ABS, UL, CSA, Lloyds
Construction
Conductors:
Annealed, Flexible Tinned Copper,
Class I per ASTM B33, B172, UL
1309 & CSA C22.2 No. 245
Insulation:
Proprietary, irradiation cross-linked
Polyolefin (Exane®).
Circuit Identification:
Power Conductors: Dark Gray,
Red, Blue
Ground Conductors: Green
Ground Conductors:
Three segmented, Green
Insulated grounding conductors with
the same voltage rating as the circuit
conductors.
Fillers:
Flame retardant, fibrillated
Polypropylene as required.
Shield:
Overall, optimized Tinned Copper
braid with Aluminum/Polyester laminated tape providing 100% coverage.
Jacket:
Black, heavy duty, arctic grade
Neoprene. Colored Neoprene available
on request
Armor (optional):
Braided Bronze armor. Aluminum or
Tinned Copper braided armor available
on request.
Sheath (optional):
Black, heavy duty, arctic grade
Neoprene. Colored Neoprene available
on request
14
10
8
6
5
4
3
2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
1.170
1.080
0.975
0.890
0.845
0.775
0.690
0.655
0.570
0.535
0.495
0.405
0.375
0.350
0.330
0.280
0.228
0.176
29.7
27.4
24.8
22.6
21.5
19.7
17.5
16.6
14.5
13.6
12.6
10.3
9.5
8.9
8.4
7.1
5.8
4.5
3 X 6
3 X 6
3 X 6
3 X 6
3 X 6
3 X 6
3 X 8
3 X 8
3 X 10
3 X 10
3 X 10
3 X 10
3 X 10
3 X 12
3 X 12
3 X 12
3 X14
3 X 14
3 X 16
646-600V
535-600V
444-600V
373-600V
313-600V
262-600V
4/0-600V
3/0-600V
2/0-600V
1/0-600V
1-600V
2-600V
3-600V
4-600V
5-600V
6-600V
8-600V
10-600V
12-600V
2.830
2.575
2.350
3.000
2.070
1.915
1.735
1.600
1.415
1.340
1.255
1.060
0.995
0.940
0.900
0.740
0.705
0.605
0.530
0.460
Inch
71.9
65.4
59.7
76.2
52.6
48.6
44.1
40.6
35.9
34.0
31.9
26.9
25.3
23.9
22.9
18.8
17.9
15.4
13.5
11.7
mm
Nominal
Diameter
Weight
1-600V-BN
2-600V-BN
3-600V-BN
4-600V-BN
5-600V-BN
6-600V-BN
8-600V-BN
10-600V-BN
12-600V-BN
14-600V-BN
13179 646-600V-BN
11275 535-600V-BN
9196 444-600V-BN
7883 373-600V-BN
7059 313-600V-BN
5960 262-600V-BN
4968 4/0-600V-BN
4194 3/0-600V-BN
3145 2/0-600V-BN
2819 1/0-600V-BN
2435
1747
1537
1319
1201
870
661
514
373
281
3.165
2.910
2.625
2.440
2.345
2.195
2.010
1.875
1.630
1.555
1.470
1.275
1.210
1.155
1.115
0.965
0.930
0.780
0.705
0.635
Inch
Weight
80.4
73.9
66.7
62.0
59.6
55.8
51.1
47.6
41.4
39.5
37.3
32.4
30.7
29.3
28.3
24.5
23.6
19.8
17.9
16.1
10320
8892
7226
6273
5664
4869
4119
3550
2654
2414
2123
1585
1419
1253
1162
882
728
554
436
349
9878
8240
6821
5944
5212
4561
3708
3290
2463
2185
1906
1416
1256
1106
1020
765
535
400
296
249
mm lb/1,000ft Kg/Km
Nominal
Diameter
Armored & Sheathed Cables
(2) Tolerance on overall cable diameters = +/- 5%
8856
7577
6180
5297
4744
4005
3339
2818
2113
1895
1636
1174
1033
886
807
585
444
345
251
189
Part No.
VFD-3Clb/1,000ft Kg/Km
Unarmored Cables
Notes: (1) Tolerance on insulated conductor diameter = +/- 10% (= < 6 AWG)
Notes: (1) Tolerance on Insulated conductor diameter = +/- 5% (= > 5 AWG)
327.5
271.2
225.2
189.4
158.7
133.1
112.6
92.1
66.5
56.3
46.1
30.7
25.6
21.5
18.6
12.5
7.6
5.53
0.145
3.7
3.08
14-600V
12
3 X 18
0.127
3.2
1.94
14
T.C.
Insulated
Grounds
AWG Sq. mm Inches
Diameter
Over
Insulation
Part No.
VFD-3Cmm No.X AWG
Conductor
600V 3/C Type VFD Flexible Marine Variable Frequency Drive Cables
3/C Cables with AL/Polyester Tape Shield + T.C. Braid and 3 Insulated Tinned Copper Grounds
600V EXANE ® VFD
15
313
373
444
535
646
1.270
1.155
1.055
0.980
0.930
32.3
29.3
26.8
24.9
23.6
3 X 6
3 X 6
3 X 6
3 X 6
3 X 6
3 X 6
646-2KV
535-2KV
444-2KV
373-2KV
313-2KV
262-2KV
Notes: (1) Tolerance on insulated conductor diameter = +/- 5%
(2) Tolerance on overall cable diameters = +/- 5%
327.5
271.2
225.2
189.4
158.7
0.862
21.9
133.1
4/0-2KV
262
3 X 8
0.790
20.1
112.6
4/0
T.C.
Insulated
Grounds
AWG Sq. mm Inches
Diameter
Over
Insulation
Part No.
VFD-3C-HD
mm No.X AWG
Conductor
3.115
2.865
2.590
2.430
2.320
2.175
2.020
Inch
79.1
72.8
65.8
61.7
58.9
55.2
51.3
mm
Nominal
Diameter
Weight
9447
8075
6689
5813
5111
4464
3826
4/0-2KV-BN
14058 646-2KV-BN
12017 535-2KV-BN
9955 444-2KV-BN
8651 373-2KV-BN
7606 313-2KV-BN
6643 262-2KV-BN
5694
3.470
3.220
2.945
2.725
2.615
2.470
2.315
Inch
Weight
88.1
81.8
74.8
69.2
66.4
62.7
58.8
11047
9566
8034
6902
6138
5430
4734
16440
14235
11956
10272
9135
8080
7045
mm lb/1,000ft Kg/Km
Nominal
Diameter
Armored & Sheathed Cables
Part No.
VFD-3C-HD
lb/1,000ft Kg/Km
Unarmored Cables
2 KV Heavy Duty Type VFD Flexible Marine Variable Frequency Drive Cables
3/C Cables with AL/Polyester Tape Shield + T.C. Braid and 3 Insulated Tinned Copper Grounds
2KV Heavy Duty EXANE ® VFD
16
10
8
6
5
4
3
2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
1.190
1.100
0.995
0.910
0.865
0.795
0.710
0.675
0.590
0.555
0.515
0.425
0.395
0.370
0.350
0.300
0.248
0.206
30.2
27.9
25.3
23.1
22.0
20.2
18.0
17.1
15.0
14.1
13.1
10.8
10.0
9.4
8.9
7.6
6.3
5.2
3 X 6
3 X 6
3 X 6
3 X 6
3 X 6
3 X 6
3 X 8
3 X 8
3 X 10
3 X10
3 X 10
3 X 10
3 X 10
3 X 12
3 X 12
3 X 12
3 X 14
3 X 14
3 X 16
646-2KV
535-2KV
444-2KV
373-2KV
313-2KV
262-2KV
4/0-2KV
3/0-2KV
2/0-2KV
1/0-2KV
1-2KV
2-2KV
3-2KV
4-2KV
5-2KV
6-2KV
8-2KV
10-2KV
12-2KV
2.920
2.665
2.440
2.255
2.160
2.010
1.825
1.750
1.505
1.430
1.345
1.150
1.205
1.125
1.090
0.990
0.820
0.740
0.665
0.625
Inch
74.2
67.7
62.0
57.3
54.9
51.1
46.4
44.5
38.2
36.3
34.2
29.2
30.6
28.6
27.7
25.1
20.8
18.8
16.9
15.9
mm
Nominal
Diameter
Weight
8980
7691
6357
5461
4902
4154
3476
3051
2219
2004
1740
1265
1233
1056
973
785
546
452
347
295
4/0-2KV-BN
3/0-2KV-BN
2/-2KV-BN
1/0-2KV-BN
1-2KV-BN
2-2KV-BN
3-2KV-BN
4-2KV-BN
5-2KV-BN
6-2KV-BN
8-2KV-BN
10-2KV-BN
12-2KV-BN
14-2KV-BN
3.255
3.000
2.715
2.530
2.435
Weight
82.7
76.2
69.0
64.3
61.8
58.0
53.3
51.4
45.2
41.8
39.6
34.7
36.1
34.0
33.0
30.6
26.5
24.5
22.4
20.3
10425
9030
7402
6421
5829
5009
4267
3798
2876
2518
2221
1683
1664
1467
1375
1149
856
730
603
503
15515
13439
11016
9555
8675
7454
6350
5653
4280
3747
3305
2504
2476
2184
2046
1710
1274
1087
897
749
mm lb/1,000ft Kg/Km
(2) Tolerance on overall cable diameters = +/- 5%
13364 646-2KV-BN
11446 535-2KV-BN
9460 444-2KV-BN
8128 373-2KV-BN
7295 313-2KV-BN
2.285
2.100
2.025
1.780
1.645
1.560
1.365
1.420
1.340
1.300
1.205
1.045
0.965
0.880
0.800
Inch
Nominal
Diameter
Armored & Sheathed Cables
6181 262-2KV-BN
5173
4541
3303
2982
2589
1883
1835
1572
1448
1168
813
673
516
439
Part No.
VFD-3Clb/1,000ft Kg/Km
Unarmored Cables
Notes: (1) Tolerance on insulated conductor diameter = +/- 10% (= < 6 AWG)
Notes: (1) Tolerance on Insulated conductor diameter = +/- 5% (= > 5 AWG)
327.5
271.2
225.2
189.4
158.7
133.1
112.6
92.1
66.5
56.3
46.1
30.7
25.6
21.5
18.6
12.5
7.6
5.53
0.175
4.4
3.08
14-2KV
12
3 X 18
0.157
4.0
1.94
14
T.C.
Insulated
Grounds
AWG Sq. mm Inches
Diameter
Over
Insulation
Part No.
VFD-3Cmm No.X AWG
Conductor
2KV 3/C Type VFD Flexible Marine Variable Frequency Drive Cables
3/C Cables with AL/Polyester Tape Shield + T.C. Braid and 3 Insulated Tinned Copper Grounds
2KV EXANE ® VFD
17
Exane® MR
Power, Control & Instrumentation Cables
World Class Engineered Cable
Armored & Unarmored (Offshore & Land Rigs)
Inner Jacket
Mud & Oil Resistant
Outer Sheath
Mud & Oil Resistant
Armor
Conductor
Tin-Coated Copper
IEEE 1580
Drilling Fluid Resistant
1KV; 2KV; 2KV(HD); 125˚C
UL/CSA Marine Shipboard
Rated at 110˚C
Insulation
Crosslinked Polyolefin
Scope
Features
• Thermosetinsulation
• Heat,sunlight,&moistureresistant
• Extremelyflameretardant
• Easytoinstall
• Easytostrip–hasnoseparatortape
• Extremelyflexible
• FlexibleTin-coatedconductorsforimprovedterminationsand
corrosionresistance
• Pigmentedinsulationwithvividcolors
• PassestheUL2225Crush&ImpactTestrequirementsforTypeMC-HL
• Passesminus55˚Ccoldbend
• Passesminus40˚Ccoldimpact
Performance Standards
• IEEE45/1580TypeP
• UL1309X110MarineShipboardCable
• CSAC22.2No.245X110MarineShipboard
• IntertekTestingService(ETL)certifiedasTypeP
• PassesIEEE1202&FT-4,70,000Btu/hrVerticalTrayFlameTests
• PassestheIEC60332-3-22CategoryA/FFlameTest
• TypeApprovedbyABS,DNVandLloyd’sRegisterNA
• Armored&SheathedcablesaresuitableforuseinClass1,Division1and
Zone1hazardouslocations
• UnarmoredcablesaresuitableforuseinClass1,Div2&Zone2
• Passesmud&oilresistanceperIEC61892-4-AnnexD
Exane MR multi-conductor power
cables, armored & unarmored, rated
1KV, 2KV and 2KVHD are an extremely
tough construction ideally suited for use
in rugged marine/oil rig applications
exposed to drilling fluids and muds. The
Exane insulation is radiation crosslinked and provides outstanding physical
properties, resistance to abrasion,
cut-through, low and high temperatures,
drilling fluids and muds, sunlight, flame,
and moisture. Exane® MR is extremely
tough and durable and withstands
the arduous environmental conditions
experienced in offshore mobile drilling
units (MODU), FPSO’s, TLP’s and land
rigs for oil and gas drilling rigs. Exane®
MR’s 125˚C temperature rating for
short durations lends itself to handle
higher ampacity levels and higher
safety margins in the field. It’s extremely
flexible design and tightly controlled
dimensions lead to benefits regarding
lower weight, tray fill, ease of installation
and long service life in drag chains.
®
Construction
Conductor: Flexible,softannealedtinnedcopperperASTMB33&IEEE1580
Insulation: Irradiationcross-linkedPolyolefin,Exane®125˚C
Circuit Identification: Standard–VividpigmentedinsulationcolorsperIEEE1580.Optional–Dk.Gray+No’s
Fillers: Whenrequired,flameretardantandnon-hygroscopic
Inner Jacket: Black,cross-linkedchlorosulfonatedPolyethylene(CSPE).Sunlightresistant
Armor (optional): BronzeBraid–Standard.TinnedCopperBraid–Optional
Outer Jacket (optional): Black,cross-linkedchlorosulfonatedPolyethylene(CSPE).Sunlightresistant
Temperature Rating: RSCCWire&Cablerated125˚C,UL/CSA110˚C,IEEE100˚C
A Marmon Wire & Cable / Berkshire Hathaway Company
RSCC Wire & Cable LLC © 2013 • 20 Bradley Park Road • East Granby, CT 06026 USA • 800-327-7625 • Tel: 860-653-8300 • Fax: 860-653-8301 • www.exanecable.com
For more information contact the RSCC factory at 860-653-8300.
How To Handle
Cable Reels
YES
NO
Always load and store reels
upright on their flanges and
block securely.
Upended heavy reels will often
be damaged.
Reels can be hoisted with a
properly secured shaft extending through both flanges.
Do not lift by a single reel flange.
Cable or reel may be damaged.
Cradle both reel
between fork tines.
Never allow fork tines to touch
the cable surface or reel wrap.
flanges
Lower reels from a truck using a
hydraulic gate, hoist or fork lift.
LOWER CAREFULLY.
Never drop reels.
ISO 9001 REGISTERED
East Granby, CT
A Division of RSCC Cable Group
EX-125 Rev. 6 (April 2013)
20 Bradley Park Road
East Granby, CT 06026
Tel: 860-653-8300
Fax: 860-653-8301
800-327-7625
www.r-scc.com
Houston, Texas Office
RSCC
2203 Timberloch Place
Suite 132
The Woodlands, Texas 77380
Tel: 281-820-7850
Fax: 281-820-7817
© 2013 RSCC Wire & Cable LLC
A Marmon Wire & Cable
Berkshire Hathaway Company