home inspection report Home. Safe. Home. Each office is independently owned and operated. | ©2013 The HomeTeam Inspection Service, Inc. All rights reserved. What is a home inspection? The purpose of a home inspection is to visually examine the readily accessible systems and components of the home. The inspectors are not required to move personal property, materials or any other objects that may impede access or limit visibility. Items that are unsafe or not functioning, in the opinion of the inspector, will be described in accordance with the standards of practice by which inspectors abide. What does this report mean to you? This inspection report is not intended as a guarantee, warranty or an insurance policy. Because your home is one of the largest investments you will ever make, use the information provided in this report and discuss the findings with your real estate agent and family to understand the current condition of the home. Our inspections exceed the highest industry standards. FAST Because we use a team of inspectors, each an expert in his or her field, our inspections are performed with greater efficiency and more expertise and therefore exceed the highest industry standards. We are pleased to provide this detailed report as a service to you, our client. TRUSTED We believe in your dream of home ownership. We want to help you get into your dream home. Therefore, we take great pride in assisting you with this decision making process. This is certainly a major achievement in your life. We are happy to be part of this important occasion and we appreciate the opportunity to help you realize your dream. We exceed your expectations. Buying your new home is a major decision. Much hinges on the current condition of the home you have chosen. That is why we have developed the HomeTeam Inspection Report. Backed by HomeTeam’s experience with hundreds of thousands of home inspections over the years, the report in your hand has been uniquely designed to meet and exceed the expectations of today’s homebuyers. We are proud to deliver this high-quality document for your peace of mind. If you have any questions while reviewing this report, please contact us immediately. Thank you for allowing us the opportunity to serve you. ACCURATE FileNumber:SAMPLEREPORT AddressofInspection:1234FifthStreet GENERALDESCRIPTION Throughoutthisreport,theterms"right"and"left"areusedtodescribethehomeasviewedfromthestreet.Asystem orcomponenthasamajorvisualdefectifitiseitherunsafeornotfunctioningandcannotbereplacedorrendered safeorfunctionalforlessthan$1,000.TheHomeTeaminspectsforevidenceofstructuralfailureandsafetyconcerns only.Thecosmeticconditionofthepaint,wallcovering,carpeting,windowcoverings,etc.,arenotaddressed.All conditionsarereportedastheyexistedatthetimeoftheinspection. Routinemaintenanceandsafetyitemsarenotwithinthescopeofthisinspectionunlesstheyotherwiseconstitute major,visuallyobservabledefects.Althoughsomemaintenanceand/orsafetyitemsmaybedisclosed,thisreportdoes notincludeallmaintenanceorsafetyitems,andshouldnotberelieduponforsuchitems. Ifreferenceismadeinthereporttoactiveleaks,moisturepenetration,moisturestainsand/orcondensationstainsitis importanttobeawareofthepotentialformoldgrowthaswaterisoneoftheessentialfactorsforitsgrowth.Moldis believedtotriggerallergicreactionsandevenserioushealthproblems.Ifyouareconcerned,contactingaqualified moldtestingcompanyisrecommended.TheHomeTeamcanprovidetheseservicesuponrequest. Theinspectedpropertyconsistedofacolonialwoodframedstructurewithstuccothatwasvacantatthetimeofthe inspection.Therewerenomajorvisualdefectsonthevisualportionsofthesiding. Theapproximatetemperatureatthetimeoftheinspectionwas70-75degreesFahrenheit,andtheweatherwassunny andclear.Theutilitieswereonatthetimeoftheinspection. Thehomewassituatedonalightlyslopedlot.Thegeneralgradearoundthehomeappearedtobeadequatetodirect rainwaterawayfromthefoundation.Theageofthehome,asreportedbytheMLSsheet,wassaidtobe104years old. Therewasaconcretewalkwayleadingtoaconcretefrontentrywayinthefrontofthehome.Therewerenomajor visualdefectsobservedinthewalkwayorthefrontentryway. remediationofstucco Minorcrackingofstucco Remediationtosiding/soffit Page2of12 FileNumber:SAMPLEREPORT AddressofInspection:1234FifthStreet Itwaspointedoutthatthereweresignsofrecentremediationtothesidingandtrim.Monitoringforcracks andrepairingpromptlywassuggestedtohelppreventdeteriorationofthestucco. Itwaspointedoutthatthereweretreesandorvegetationnearorincontactwiththehomeatthetimeof inspection.Cuttingbackthegrowthwasrecommended. Itwasnotedthatthefrontstepswereofdifferentheights.Thisisapotentialtriphazard.Repairsare recommended. DECKS Therewasawooddecklocatedinthebackofthehome.Theredidnotappeartobesignificantdeteriorationofthe wood.Awooddeckshouldbecleanedandsealedregularlytopreventdeterioration.Therewerenomajorvisual defectsobservedonthevisibleportionsofthedeckorsupportstructure. Page3of12 FileNumber:SAMPLEREPORT AddressofInspection:1234FifthStreet ROOFSTRUCTURE Theroofwasagableandvalleydesigncoveredwithasphalt/fiberglassshingles.Observationoftheroofsurfacesand flashingwasperformedfromgroundlevelwiththeaidofbinoculars.Theageoftheroofcovering,asreportedbythe buyer,wasapproximately10years.Thereweremultiplelayersofshinglesontheroofatthetimeoftheinspection. Therewasminimalcurlingandmoderatesurfacewearobservedontheroofshinglesatthetimeoftheinspection. Theseconditionsindicatetheroofshinglesinthesecondhalftheirusefullife. Thisvisualroofinspectionisnotintendedasawarrantyoranestimateontheremaininglifeoftheroof.Anyroof metal,especiallytheflashingandvalleys,mustbekeptwellpaintedwithapaintspeciallyformulatedfortheuse.There werenomajorvisualdefectsdetectedontheexterioroftheroof. Itwasnotedthattherewererepairstotherearvalleyoftheroofatthetimeofinspection.Thisareadidnot appeartobeleaking.Arooferwouldbeagoodresourceforadvisementhere. Therewasonechimney.Observationofthechimneyexteriorwasmadefromtheground,withtheaidofbinoculars. Therewerenomajorvisualdefectsobservedontheexterior. Theroofdrainagesystemconsistedofaluminumguttersanddownspouts,whichappearedtobefunctionalbutinneed ofrepairatthetimeoftheinspection.Guttersanddownspoutsshouldreceiveroutinemaintenancetoprevent prematurefailure.Therewerenomajorvisualdefectsobservedonthevisibleportionsoftheguttersordownspouts. Missingdownspout FOUNDATION Thefoundationwasconstructedofconcreteblock.Asingleinspectioncannotdeterminewhethermovementofa foundationhasceased.Anycracksshouldbemonitoredregularly.Therewerenomajorvisualdefectsobservedon thevisibleportionsofthefoundation. Therewereseveralminor,hairlinecracksobservedonthefoundation.Thecrackswere1/16-inchorlessinwidth. Thesecracksdidnotappeartohaveanystructuralsignificanceatthetimeoftheinspection. Page4of12 FileNumber:SAMPLEREPORT AddressofInspection:1234FifthStreet BASEMENT(LOWERLEVEL) Thepartialbasementpluscrawlspacewasunfinished,andcontainedthefollowingmechanicalsystems:furnaceand waterheater. Critterden Itwasnotedthatthetherewaswhatappearedtobeapastorpresentcritterdenonthefrontofthe basement.Patchingtheholeinthewallwassuggested. Itwasnotedthattherewasevidenceofwoodrotonthebasementwalls.Thesewallarenotstructural. Thebasementwasmostlydryatthetimeoftheinspection.However,thereweresomesignsofpastmoisture infiltrationonthebasementwallsandfloor,especiallyinthecorners.Propergradingandguttermaintenancewill helpreducemoistureinthebasement.Becausethebasementisbelowgrade,thereexistsavulnerabilitytomoisture penetrationafterheavyrains.Therewerenomajorvisualdefectsobservedinthebasement. Page5of12 FileNumber:SAMPLEREPORT AddressofInspection:1234FifthStreet FLOORSTRUCTURE Thevisiblefloorstructureconsistedofatongueandgroovesubfloor,supportedbytwo-inchbyten-inchwoodjoist spacedsixteeninchesoncenter.Therewasa4x8-inchcenterbeamandfour-inchsteelpostsorpiersforload bearingsupport.Therewerenomajorvisualdefectsobservedinthevisibleportionsofthefloorstructure. Supportpost Itwasnotedthattherewerecorroded/rustedsupportpostsinthebasement.Replacementofthepostsis recommended. PLUMBING Thevisiblewatersupplylinesthroughoutthehomewereplasticandcopperpipe.Thewaterwassuppliedbyapublic watersupply.Thevisiblewastelinesconsistedofcopper,castiron,andPVCpipe.Thehomewasconnectedtoa publicsewersystem.Allplumbingfixturesnotpermanentlyattachedtoahouseholdappliancewereoperatedand inspectedforvisibleleaks.Waterflowthroughoutthehomewasaverage.Waterpressurewastestedinthekitchen andfoundtobeadequate.Therewerenomajorvisualdefectsobservedinthevisibleportionsoftheplumbingsystem. Itwasnotedthattheutilitytubwasnotsecureandinpoorcondition.Replacingthetubwasdiscussedat theinspection. Thewatermeterwaslocatedinthebasement.Themainwatershutoffvalveforthehomewaslocatedadjacenttothe waterserviceentrypointinthebasement. Thegasmeterwaslocatedinthebasement.Althoughnoactualtestingwasperformedtodetectthepresenceofgas fumes,therewasnonoticeableodorofgasdetectedatthetimeoftheinspection.Ifthereareflexiblegaslinesina homeitisnowrequiredinsomemunicipalitiesthatthistypeofgaslinebebonded(Grounded). Page6of12 FileNumber:SAMPLEREPORT AddressofInspection:1234FifthStreet Behindstove Inbasementfordryer Itwasnotedthattherewereopengaslinesinthehome.Cappingthegaslinesisrecommendedforsafety reasons. Therewasa30-galloncapacity,naturalgaswaterheaterlocatedinthebasement.Thewaterheaterwas manufacturedbyA.O.Smith.Informationonthewaterheaterindicatedthatitwasmanufactured12yearsago.A temperatureandpressurereliefvalve(T&P)waspresent.Becauseofthelimebuild-uptypicalofT&Pvalves,wedo nottestthem.Anoverflowlegwaspresent.Itshouldterminateclosetothefloor.Yoursafetydependsonthepresence ofaT&Pvalveandanoverflowlegterminatingclosetothefloor.Thewaterheaterwasfunctional. Itwasnotedthattherewaswaterontheflooraroundwaterheateratthetimeofinspection.Further evaluationisneededastherewasalsoafloordrainnearthewaterheater.Thesourceofthewatercouldnot beconfirmedattheinspection.Contactingaplumberforadvisementandrepairsasneededwas recommended. ELECTRICSERVICE Theoverheadelectricservicewireenteredthehomeontheleftsidewall.Theelectricmeterwaslocatedonthe exteriorwall.TheservicewireenteredaMurrayservicepanel,locatedonthebasementwallwitha100ampand 120/240voltratedcapacity.Thebranchcircuitswithinthepanelwerecopper.Thesebranchcircuitsandthecircuit breakertowhichtheywereattachedappearedtobeappropriatelymatched.Thevisiblehousewiringconsisted primarilyoftheromextypeandappearedtobeingoodcondition.Itisrecommendedthatanynecessaryorsuggested repairsbeperformedbyalicensedelectrician. Arepresentativenumberofinstalledlightingfixtures,switches,andreceptacleslocatedthroughoutthehomewere inspectedandwerefoundtobefunctional.Thegroundingandpolarityofreceptacleswithinsixfeetofplumbing fixtures,andthoseattachedtogroundfaultcircuitinterrupters(GFCI),ifpresent,werealsotested.AllGFCI receptaclesandGFCIcircuitbreakersshouldbetestedmonthly.ThereweresomeGFCIprotectedcircuitslocatedin thehome.ThepresentandtestedGFCIswerefunctional.Allnon-functionalGFCIsshouldbereplacedwithfunctional GFCIs.InstallingGFCI'snearallwatersorcesisrecommended. Page7of12 FileNumber:SAMPLEREPORT AddressofInspection:1234FifthStreet Anyopenelectricalboxesshouldbecoveredforsafetyreasons.Therewerealsotwoprongedelectric receptaclesinthehome.Thesereceptaclesareconsideredoutdated.Upgradingtogrounded,threepronged receptaclesissuggested. Theelectricalserviceappearedtobeadequate.Alarms,electronickeypads,remotecontroldevices,landscape lighting,telephoneandtelevision,andallelectriccompanyequipmentwerebeyondthescopeofthisinspection.There werenomajorvisualdefectsobservedintheelectricalsystem. SMOKEALARMS Therewassmokealarmsfoundinthehouse.Forsafetyreasons,thesmokealarmsshouldbetestedupon occupancy.Thebatteries(ifany)shouldbereplacedwithnewoneswhenyoumoveintothehouse,andtestedona monthlybasisthereafter. Page8of12 FileNumber:SAMPLEREPORT AddressofInspection:1234FifthStreet WINDOWS,DOORS,WALLSANDCEILINGS Arepresentativenumberofaccessiblewindowsanddoorswereoperatedandfoundtobefunctionalbutinpoor condition.Theprimarywindowswereconstructedofwood,doublehungstyle,withsinglepaneglass.Allexteriordoors wereoperatedandfoundtobefunctional.Theexteriordoorlocksshouldbechangedorre-keyeduponoccupancy. Possibleproblemareasmaynotbeidentifiedifthewindowsordoorshavebeenrecentlypainted.Therewereno majordefectsobservedinthewindowsordoors. Therewerestairsinthehomethatdidnothavehandrailsorproperhandrails.Allstairsshouldhavehand railsforsafetyreasons. Basementdoor Itwasnotedthattheexteriorbasementdoorwasinpoorconditionatthebottom. Therewereseveralwindowsinthehomethatwerepaintedshut,hardtoopenorhadmissingordamaged counterweightmechanisms.Thisisapotentialsafetyhazard.Repairsarerecommended.Awindowcompany wouldbeagoodresourcehere. Page9of12 FileNumber:SAMPLEREPORT AddressofInspection:1234FifthStreet Theinteriorwallandceilingsurfaceswerefinishedwithplaster.Possibleproblemareasmaynotbeidentifiedifthe interiorwallandceilingsurfaceshavebeenrecentlypainted.Therewerenomajorvisualdefectsobservedinthe interiorwallsorceilings. FIRSTLEVEL Thefirstlevelconsistedofakitchen,diningroom,livingroom,twobedroomsandafullbath.TheHomeTeaminspects forevidenceofstructuralfailureandsafetyconcernsonly.Thecosmeticconditionofthepaint,wallcovering, carpeting,windowcoverings,etc.,arenotaddressed.Therewerenomajorvisualdefectsobservedonthefirstlevel. Therewerestairsinthehomethatdidnothaveproperhandrails.Allstairsshouldhavehandrailsforsafety reasons. Thevisibleportionsofthecabinetsandcountertopswereinserviceablecondition.Theapplianceswereturnedonto checkoperationalfunctiononly.Nowarranty,expressorimplied,isgivenforthecontinuedoperationalintegrityofthe appliancesortheircomponents.Thekitchencontainedthefollowingappliances: TheKenmorenaturalgasfreestandingrangewasinspectedanddidnotappeartobefunctional.Theaccuracyof theclock,timersandsettingsonovensarenotwithinthescopeofthisinspection. TheFrigidairerefrigeratorwasinspectedanddidappeartobefunctional.Thetemperaturesettingisnotwithinthe scopeoftheinspection.Itwasnotedthattheredidnotappeartobeawatersupplytotheicemakerinthe freezer. TheWhirlpooldishwasherwasobservedthroughacycleanddidnotappeartobefunctional(Nowater)whenset onthe"wash"and"drain"cycle. Page10of12 FileNumber:SAMPLEREPORT AddressofInspection:1234FifthStreet TheNutonerangehoodwasinspectedanddidappeartobefunctional.Theexhaustcapacityisnotwithinthescopeof thisinspection.Cleaningthefanandfiltermayincreasetheexhaustcapability. TheIn-Sink-Eratordisposalwasinspectedanddidappeartobefunctional.Theefficiencyratingisnotwithinthescope oftheinspection. SECONDLEVEL Thesecondlevelofthehomeconsistedofthreebedroomsandonefullbath Therewerenomajorvisualdefectsobservedonthesecondlevel. FIREPLACE Therefireplaceinthehome.Thevisualconditionatthetimeoftheinspectionisindicatedasfollows. Forsafetyreasons,itwasrecommendedthatthefireplaceandthechimneytowhichitisventedshouldbecleaned andre-inspected,astheremaybehiddendefects,notfullyvisibleatthetimeoftheinspection.Thefireplacewasnot testedforoperationorfunction. ATTICSTRUCTURE Theatticwasaccessedthroughadoorinthe2ndfloorhallway.Theatticabovethelivingspacewasinsulatedwith loose-fillinsulation,approximately4to6-inchesindepth.VentilationthroughouttheatticwasprovidedbyNoventing,,,, vents.Theroofstructureconsistedoftwo-inchbysix-inchwoodraftersspaced24inchesoncenterandspaced sheathing. Becauseoftheconfigurationoftheframing,whichlimitedaccess,itwasnotpossibletoinspectallareasoftheattic. Therewasnomoisturevisibleintheatticspace.Theabsenceofvisibleindicationsofmoistureisnotnecessarily conclusiveevidencethattheroofisfreefromleaks.Theonlywaytobesurearoofdoesnotleakistoinspectthe undersideoftheroofduringaheavyrain.Therewasevidenceofpastmoistureinfiltration.Therewerenomajorvisual defectsobservedintheatticorroofstructure. Page11of12 FileNumber:SAMPLEREPORT AddressofInspection:1234FifthStreet HEATINGUNITREPORT Theheating,systemwasinspectedbyTheHomeTeam.Annualmaintenanceoftheheatingequipmentisessentialfor safeandefficientperformance,whichwillmaximizethesystem'susefullife. Theresultsofourvisualandoperationalinspectionoftheheatingsystemaredescribedbelow.Periodicpreventive maintenanceisrecommendedtokeepthisunitingoodworkingcondition.ThehomewasheatedbyaDunkirknatural gasboiler,which,isapproximately9yearsold.Theunitwaslocatedinthebasementofthehome.Ithasan approximatenetheatingcapacityof187,500BTUH. NOTE:Withoutremovingtheburnerstogaincompleteaccess,andwiththelimitedviewingareaoftheheat exchanger,athoroughinspectionisnotpossible. Theheatingsystemwasfoundtobefunctionalbutdirty Dirtybolier DUCTWORK Airflowthroughoutthehousemaybebalancedbyadjustinganydampersinthesupplyducts,orbyadjustingthe supplyregisters. CONTROLS Thecontrolfortheheatingandairconditioningsystemwasa24-voltthermostatlocatedonaninteriorwallofthe home.ThethermostatwasmanufacturedbyHoneywellandwasfoundtobeinworkingorder. Page12of12
© Copyright 2026 Paperzz