A2 1000 Series Aktra II Cutoff Floodlight, 1000W HID Type: Job: Approvals: Catalog Number: - Series/Source -Wattage - Optics (Reflector) - Voltage Overall Dimensions - Mounting For Reference Only Options (Factory Installed) Finish Accessories (Field Installed) Date: Page 1 of 6 Specifications Housing Mastfitter Mount (M) Side View - The Aktra II 1000 floodlight features a cast aluminum alloy housing with integral heat dissipating fins and heavy-duty hinges. Standard unit constructed to IP54. 30.0” (76.2cm) Optics (Reflector) 17.75” (45.09cm) 4” (10.16cm) Aktra reflector system. High purity anodized aluminum reflectors assure maximum efficiency. A secondary internal reflector element reflects high angle rays back into the beam to achieve high beam utilization. Meets IES definition of cutoff distribution. Lamp Access Hinged lens frame allows convenient lamp access. Lens End View Clear tempered glass lens is secured to cast aluminum door frame by 10 retaining clips and sealed with a gasket. 19.75” (50.17cm) Socket Pre-wired grip-type mogul base socket, 4KV rated for MH, 5KV for HPS. Glass end of the lamp is held in precise photometric alignment and protected from breakage by a Stabilux socket. Ballast High power factor ballast with reliable starting down to -29°C (-20°F) for Metal Halide lamps, -34°C (-30°F) for Pulse Start Metal Halide lamps, and -40°C (-40°F) for High Pressure Sodium. Ballast has Class H, 180°C (356°F) rated insulation. Crest factor does not exceed 1.8. Capacitor and HPS ignitor are separated from the ballast core and coil to maximize life by minimizing heat. 22.5” (57.15cm) Lens Aiming 22.5” (57.15cm) Cutoff distribution achieved at 62.5° (2 times mounting height). Aiming above 63° provides semi-cutoff and non-cutoff distribution. Mounting Fixture may be specified with a cast aluminum mastfitter, suitable for mounting to a 2-3/8” O.D. vertical tenon; or formed plate steel yoke. Yoke mount allows mounting directly to any flat surface. Yoke Mount (Y) Side View Finish 31.0” (78.74cm) Standard finish shall be dark bronze UltraClad polyester powder coating, 2.5 mil nominal thickness, electrostatically applied and oven cured. All components shall be thoroughly cleaned by a 5 stage pre-treatment process including iron phosphate bath and non-chromic acid etching stages, ensuring optimum performance characteristics. Other colors may be specified. 30.0” (76.2cm) 17.75” (45.09cm) 5.0” (12.7cm) Listings ETL/cETL listed to the UL 1598 standard, suitable for Wet Locations. The quality systems of this facility have been registered by UL to the ISO 9001 Series Standards. Warranty / Terms and Conditions Bottom View - Yoke Mount, see page 5 for details. Gardco luminaires feature a 5 year limited warranty. See Warranty Information on www.sitelighting.com for complete details and exclusions. Polycarbonate lenses carry a 1 year warranty only. Some luminaires use fluorescent or high intensity discharge (HID) lamps that contain small Hg amounts of mercury. Such lamps are labeled ‘Contain Mercury’ and/or with the symbol ‘Hg’. Weight 96 lbs (43.54 kgs) EPA data shown on page 3. © 2013 Koninklijke Philips Electronics N.V. All rights reserved. Specifications are subject to change without notice. G200-118/0313 Lamps that contain mercury must be disposed of in accordance with local requirements. Information regarding lamp recycle and disposal can be found at www.lamprecycle.org. A2 1000 Series Aktra II Cutoff Floodlight, 1000W HID Type: Job: Page 2 of 6 Series/Source-Wattage Metal Halide Voltage Optics (Reflector) r A r A2M-1000 r C Pulse Start r M r 208 (Standard) r Y Yoke Mount Mastfitter Mount r 277 r 480 High Pressure Sodium r QV(2) r A2S-1000 (1) For acceptable performance, note position orientation specific nature of Pulse Start lamps. Consult factory. Options (Factory Installed) r 120 r 240 r D r A2P-1000 (1) Mounting (2) Allows field selection of 120/208/240/277 voltage. (No 480V). Certain options may require voltage selection as well. Finish Accessories (Ordered Separately) r BL Bi-Level dimming r TDB Textured Dark Bronze r F1-KIT Single Fuse Kit (120/277V) r CSR Hot Quartz Restrike r TGR Textured Gray r F2-KIT Double Fuse Kit (208/240/480V) r LQ Hot/Cold Quartz Restrike r TBK Textured Black r PX-1-TL r LQ1 Separately Wired (120V) Quartz Restrike r F1 r TWHT Textured White Heavy-Duty Cross Arm bracket with 2-3/8” pipe stub, Galvanized finish Single Fuse (120/277V) Double Fuse (208/240/480V) Textured Satin Aluminum r FB-1-TL r F2 r TSA Heavy-Duty Flat Base mount, Galvanized finish r TLR Twist Lock Receptacle (photocell by others) r TGN Textured Green r AL-10-A2 Auxiliary Polymer Lens r 50HZ 50 Hz ballast operation r A2-AIM A2 Aiming Device r WB-1 Wall bracket for mounting to flat vertical surface (bullhorn) r WB-5 Surface Mounted Wiring box r PM-1-HD Heavy-Duty Wood pole mounting kit for single fixture with one U-arm r PM-2-HD Heavy-Duty Wood pole mounting kit for two fixtures with two U-arms r PM-3-HD Heavy-Duty Wood pole mounting kit for three fixtures with three U-arms r PM-4-HD Heavy-Duty Wood pole mounting kit for four fixtures with four U-arms r RAL(*) Special Tiger Drylac powdercoat finish (*) = specify color (*) Specify RAL color number from RAL color chart. Consult factory for assistance in color selection. © 2013 Koninklijke Philips Electronics N.V. All rights reserved. Specifications are subject to change without notice. www.philips.com/luminaires G200-118/0313 A2 1000 Series Aktra II Cutoff Floodlight, 1000W HID Type: Job: Page 3 of 6 Distribution Guide & Ballast Data 1 Source Type(2) Catalog Number Reflector Lamp(3) Field Angle Beam Angle Type Envelope Based on 10% Based on 50% .ies File Name Ballast Type (4) ANSI Code Line Current Line 120 / 208 / 240 / 277 / 480 Watts MH A2M-1000 A2M-1000 A2M-1000 A C D BT37 BT37 BT37 129H x 22V 103H x 90V 80H x 28V 75H x 8V 62H x 27V 53H x 14V a2m100a.ies a2m100c.ies a2m100d.ies CWA CWA CWA M47 / H36 M47 / H36 M47 / H36 9.2 / 5.6 / 4.7 / 4.1 / 2.4 9.2 / 5.6 / 4.7 / 4.1 / 2.4 9.2 / 5.6 / 4.7 / 4.1 / 2.4 1080 1080 1080 PS A2P-1000 A2P-1000 A2P-1000 A C D BT37 BT37 BT37 129H x22V 103H x 90V 80H x 28V 75H x 8V 62H x 27V 53H x 14V a2p100a.ies a2p100c.ies a2p100d.ies CWA CWA CWA M141 M141 M141 9.0 / 5.2 / 4.5 / 3.9 / 2.4 9.0 / 5.2 / 4.5 / 3.9 / 2.4 9.0 / 5.2 / 4.5 / 3.9 / 2.4 1080 1080 1080 HPS A2S-1000 A2S-1000 A2S-1000 A C D E25 E25 E25 117H x 20V 100H x 89V 90H x 72V 62H x 7V 60H x 28V 63H x 14V a2s100a.ies a2s100c.ies a2s100d.ies CWA CWA CWA S52 S52 S52 9.5 / 5.5 / 4.8 / 4.2 / 2.5 9.5 / 5.5 / 4.8 / 4.2 / 2.5 9.5 / 5.5 / 4.8 / 4.2 / 2.5 1100 1100 1100 (1) The Aktra II 1000 accommodates a variety of other wattages and lamps. Consult factory. (2) MH = Metal Halide, PS = Pulse Start Metal Halide, HPS = High Pressure Sodium. (3) Horizontal clear lamps recommended for optimum photometric performance. (4) CWA = Constant Wattage Autotransformer. Distribution Patterns Photometric data calculated at 50’ mounting height. A2M-1000-A A2M-1000-C 0MH 1MH 2MH 3MH 0MH Z 0° P LA NE ° 90 P X L A CE AIM NT ING ER LIN E N 3 E 2 1 .5 .25 2MH 1 .5 3MH .25 A2S-1000-C 0MH 1MH 2MH 3MH 1MH 1 .5 .25 EPA Effective Projected Area in Ft2 3.4 © 2013 Koninklijke Philips Electronics N.V. All rights reserved. Specifications are subject to change without notice. www.philips.com/luminaires G200-118/0313 2MH 3MH 3 2 1 .5 .25 4MH 1MH 3 2MH 2 3MH 1 .5 .25 4MH A2S-1000-D 0MH 1MH 2MH 3MH 0MH 3 2 0MH 1MH 3 2 4MH A2S-1000-A 0MH 1MH 2MH 3MH 0MH 1MH Y A2M-1000-D 0MH 1MH 2MH 3MH 2MH 3MH 4MH 0MH 1MH 2MH 3MH 0MH 0MH 1MH 1MH 2MH 3MH 4MH 3 2MH 2 .5 1 3MH .25 4MH A2 1000 Series Aktra II Cutoff Floodlight, 1000W HID Type: Job: Page 4 of 6 Option details (Factory Installed) BL = Bi-Level Note: Suitable for HPS in any aiming position. Consult factory when specifying dimming with Metal Halide. Bi-Level provides high/low level of lamp output with 50% power consumption. Zero crossover network avoids strobing and lamp dropout. CSR = Hot Quartz Restrike CSR - Quartz restrike using a current sensing relay; extinguishes auxiliary lamp when main arc strikes. LQ = Hot/Cold Quartz Restrike LQ - Provides LiteMatic operation for fixtures with 120V or multi-tap ballasts. LQ1 - Separately wired, externally controlled emergency lighting from a separate power source. LQ1 = Separately Wired (120V) Quartz Restrike LiteMatic Operation Note: Standard 150 watt (120V) double contact bayonet base socket. Combined Quartz wattage may not exceed HID lamp wattage. Normal Start: Main and Quartz lamps both energized. LQ1 requires an Interlock (by others) to ensure HID and Quartz source are not operated at once. F1 = Single Fuse (120V/277V) Main Lamp Reaches Approximately 40% of Rated Output: Quartz lamp automatically extinguishes (combined lamp currents never exceed that of main lamp at 100% output). When Arc Extinguished: Auxiliary quartz lamp automatically energized when power is restored. Main Lamp Reaches 40% of Rated Output: Quartz lamp automatically extinguishes Consists of 1 or 2 fuse holders and 1 or 2 KTK 30 amp fuses. F2 = Double Fuse (208V/240V/480V) Note: If ordering QV ballast, voltage must be specified. TLR = Photocontrol Receptacle Photocontrol twistlock receptacle only (Photocontrol by others). 50 HZ = 50 Hz Ballast Operation (Consult Factory) Specified for applications (outside the United States) where 50 Hertz operation is standard. Accessory details (Field Installed - Shipped Separately) F1 Kit = Single Fuse Kit (120V/277V) F2 Kit = Double Fuse Kit (208V/240V/480V) PX-1-TL = Heavy duty Cross-arm Bracket 4.75” 4.5” 1.5” 1.375” Consists of 1 or 2 fuse holders and 1 or 2 KTK 30 amp fuses. Steel angle bracket with 2” pipe stub. Four gussets provide additional mounting stability. “L” base. Hot dipped galvanized. For installing floodlights on wooden or steel cross-arms. 1.875” Top View Front View © 2013 Koninklijke Philips Electronics N.V. All rights reserved. Specifications are subject to change without notice. www.philips.com/luminaires G200-118/0313 6.25” 2-3/8” O.D. PipeTenon (15.88cm) 11” (27.94cm) 4.5” 9/16” Dia. Hole (5 Places Typical) (11.43cm) 6” (15.24 cm) 3.63” (15.88cm) A2 1000 Series 4 2 Aktra II Cutoff Floodlight, 1000W HID 3 Type: 1 REV Job: DESCRIPTION DATE BY A 1.90 WAS 1.55, 3.80 WAS 3.10, ADDED LABELS (2X) 12-10-92 LAB B MODELLEDANDREDRAWNSW,REPLACED2LABELS WITHSINGLELABELPN523908,ADD"5005H34"TOMATL. SPEC, CHARTED ASSEMBLY, ADD ASSY WIP 523959 5-8-08 McA PCN# CHK BY 20324 CF 5-12-08 Page 5 of 6 Accessory details continued (Field Installed - Shipped Separately) 12.00 FB-1-TL = Flat Base Mount Steel construction, with 2” pipe stub and four gussets for heavy-duty support. 6.00 9.38 6.25” (15.88cm) 3.80 For installing .25 (3X) floodlight to flat horizontal surfaces. 1.90 A 10.5” sq. (26.67cm) .50 B 2 11.75” sq. (29.85cm) 1.50 SEENOTE 1AND2 BENDUP65° AL-10-A2 = Auxiliary Polymer Lens Auxiliary lens for Aktra II Series floodlights. PART NO. 523908 O W N Aiming device can be sighted from either side of the fixture. See Installation Instructions for details. BE N 0° D W N A2-AIM = A2 Aiming Device 9 90 ° . D D O AIMING DEVICE MOUNTED RIGHT SIDE OF FIXTURE SIGHT THRU THIS HOLE N D AIMING DEVICE MOUNTED LEFT SIDE OF FIXTURE SIGHT THRU THIS HOLE . BE C 2.16 1/4” thick impact-resistant polymer lens, 45° furnished with mounting hardware and 135° standoffs. Provides additional protection of the glass lens. Useful life is limited by UV discoloration from sunlight, mercury or metal halide lamps. ° 17/32" Dia. Hole (4 Places Typical) Hot dipped galvanized. 4.69 D 2-3/8” O.D. Pipe Tenon B WB-1 = Wall Bracket (Bullhorn) N W N APPLYLABELTOAIMINGDEVICEAFTERITISFORMED. Use in conjunction with WB-5 for surface 1. 2-3/8” 2. OBSERVEPROPERORIENTATIONOFLABELANDALIGN ARROWSWITHHOLESASSHOWN mounted wiring. Pipe O W 90 ° 1.69 .56 .50 1.34 Used in conjuntion with WB-1 for surface SYM CL conduit feed. Tapped top, back and EXCEPT bottom for 3/4” pipe or conduit. LABEL 4 1.81 5.63” ITEM NO. (14.29cm) PART NO. 1 505709 square 2 523908 .67 WB-5 = Surface Mounted Wiring Box NOTE: 90 ° BENDUP90° (21.59cm) (4 Places T ypical) D D O 8.50” 9/16” Dia. Hole D N D BE N BE .12 90.00° Cast aluminum wall bracket for vertical surfaces only. Designed to permit 7.50 mounting of floodlights on flat vertical surfaces. 3DVIEWSHOWN FORREFERENCEONLY NOTTOSCALE DONOTSCALETHISDRAWING DWNBY DATE CHK BY DATE APPROVED BY DATE LAB 3/4” NPT CF (Top, Bottom and Back) Cast aluminum wall bracket for vertical surfaces only. Designed to permit mounting of floodlights on flat vertical surfaces. UNLESSOTHERWISESPECIFIED: Dimensions are in inches andtolerancesare: .03 .XX±________ .005 .XXX±________ 1° ANGLES±________ .015THRU6INCHES FRACTIONS±________ Machine Surface Use in conjunction with WB-5 for surface CONTROLLED DOCUMENT mounted wiring. Check ERP System Screen for Latest Revision 3 Tenon DESCRIPTION QTY (5” useable AIMING,DEVICE-A2-1000 length) 1 LABEL,A2-1000-AIMING-DEVICE 1 Roughnesstobe: 6.88” 125 (17.46cm) square NOTE:DoNotScaleDrawing THE INFORMATION CONTAINED ON THIS DRAWING IS THE EXCLUSIVE PROPERTY OF WIDE-LITE, AND MAY NOT BE COPIED, COMMUNICATED OR USED BY ANYONE WITHOUT THE EXPRESS PREMISSION OF AUTHORIZED WIDE-LITE PERSONNEL. AE 8-12-92 Wiring Inspection Plate P.O. BOX 606 (78667) 5-8-08 5-8-08 .032 THICK ALUMINUM 5005 H34 B SCALE PHONE512-392-5821FAX512-753-1172 NAME Pt.No. 1:1 523959 2 AIMINGDEVICE A2-1000 ASSEMBLED WITH LABEL DWGNO. B 3.25" Deep PAGE (8.25cm) C-17001 1 OF 1 1 Galvanized steel heavy-duty wood pole mounting kits are suitable for mounting up to four luminaires with mastfitters to 6.0”-12.0” O.D. wood poles. Shipped as components for field assembly. PM-1-HD Heavy-duty wood pole mounting kit for single luminaire, with 1 U-arm shipping weight: 15 lbs (6.80 kgs) PM-2-HD Heavy-duty wood pole mounting kit for two luminaires, with 2 U-arms PM-1-HD shipping weight: 20 lbs (9.07 kgs) PM-2-HD PM-3-HD Heavy-duty wood pole mounting kit for three luminaires, with 3 U-arms shipping weight: 26 lbs (11.79 kgs) PM-4-HD Heavy-duty wood pole mounting kit for four luminaires, with 4 U-arms shipping weight: 31 lbs (14.06 kgs) © 2013 Koninklijke Philips Electronics N.V. All rights reserved. Specifications are subject to change without notice. www.philips.com/luminaires G200-118/0313 12.0” (30.48cm) 2-3/8” O.D. tenon (typical) PM-3-HD A 1611 CLOVIS R. BARKER ROAD SANMARCOS,TX78666 MATERIAL PM-4-HD REV B A2 1000 Series Aktra II Cutoff Floodlight, 1000W HID Type: Job: Page 6 of 6 Yoke Mount detail 5.0” (12.70cm) Bottom View 0.56” Dia. (1.42cm) CL 0.75” (1.90cm) 2.5” (6.35cm) 3.5” Radius (8.89cm) 5.0” (12.70cm) CL Direction of Major Light Path 0.56” (1.42cm) 3.5” (8.89cm) 0.75” (1.90cm) Notes © 2013 Koninklijke Philips Electronics N.V. All rights reserved. Specifications are subject to change without notice. G200-118/0313 Philips Lighting Company 200 Franklin Square Drive Somerset, NJ 08873 Phone: 855-486-2216 Philips Lighting Company 281 Hillmount Road Markham ON, Canada L6C 2S3 Phone: 855-486-2216 www.philips.com/luminaires www.philips.com/luminaires
© Copyright 2026 Paperzz