GasEye tunable laser Mid – IR multi component TLS spectrometer GasEye tunable laser analyzer is a multi-component gas analyzer. It can be configured for applications in the NIR, mid-IR and IR wavelength range The measurement technology behind the GasEye allows for sensitive and selective measurements of gas concentration down to single ppb levels. The technology allows for real-time in-line measurements with a response time down to 0.1 second depending on application. The analyzer is mid-IR ready and the first to integrate interband cascade laser (ICL) technology. Airoptic has a long tradition in laser spectrometer design for industrial applications. The GasEye tunable laser gas analyzer is equipped with a self calibrating feature, making it maintenance free. The analyzer is insensitive to dust, smoke, temperature variations and optics contamination providing reliable measurements in harsh environment. Features; Real time sensing – response time below 0,5 second High selectivity – sensitive and selective measurements of gas concentration down to single ppb levels in a complex background gas matrix. GasEye tunable laser is manufactured in three different variants; o Long-Path for In-situ monitoring – reliable and representative area measurements o Cross-duct for in-line process monitoring and control Applications; Engine exhaust gas analysis Process monitoring and control in the Hydrocarbon and Chemical industry Trace components in natural gas; e.g. H2O, CO2, H2S Slip monitoring in deNOx processes Emission monitoring Combustion control Mudlogging in the Oil & Gas industry o Extractive for process monitoring in the hydrocarbon process Options; industry or for ultra sensitive Extended gas sample pressure atmospheric monitoring range Maintenance free –equipped with a self calibrating feature, minimizing the maintenance costs Robustness –reliable measurements in harsh environment, insensitive to dust, smoke, temperature variations and optics contamination Extended gas temperature range sample Additional outputs (2x Analog Out, 2x Digital out, Modbus) GasEye tunable laser Mid – IR multi component TLS spectrometer Specification Specification text Specification value Measurement principle Tunable Laser Spectroscopy Source Mid-IR ICL laser Class 1 Detection limit Depending on application Precision Depending on aplicaton Drift Neglible Minimum optometric response time 0.1 seconds Measurement range Depending on application Path Length 1 – 20 m Optical alignment Built-in red laser Factory calibrated at sample gas pressure Factory calibrated at sample gas pressure Note see table When applicable 1 atm T = 23 °C reference gas Power input 18 – 30 V Optional 100 – 240 VAC, 50 60 Hz Power Consumption 10 W Electrical Mechanical Dimensions L = 435 mm, W = 142 mm, H = 68 mm Analyzer unit Weight 2400 g Analyzer unit Environmental Ambient temperature 5 – 50 °C Ambient pressure 800 – 1200 hPa Ambient humidity RH < 85%, non condensing Communication Ethernet (RJ-45) Includes Windows Logger software Serial: RS232C standard, RS485 Analog output 4 x 4 – 20 mA measurement output Analog input 2 x 4 – 20 mA measurement input Digital output 4 x contact fault relay outputs Digital Input 2 x logical input 24 V floating Wi-Fi Windows software and web server Airoptic Ul. Rubiez 46 H 6 1 - 6 1 2 P o zn a n , P o l a n d Phone: +48 61 6272 128 Fax: +48 61 6272 129 Web: www.airoptic.pl E-mail: [email protected] Modbus TCP, RTU [option], 10/100 Base T Ethernet. Built-in Web server Modbus RTU [option] GasEye tunable laser Mid – IR multi component TLS spectrometer Measured components Gas Detection limit Range Oxygen [O2] 1 ppm 100 % Acetylene [C2H2] 20 ppb 100 ppm Ethylene [C2H4] 1 ppb 200 ppm Methane [CH4] 50 ppb 30 000 ppm Ethane [C2H6] 1 ppb 100 ppm Propane [C2H8] 15 ppb 100 ppm Buthane [C2H10] 25 ppb 200 ppm Ethanol [C2H5OH] 15 ppb 10 000 ppm Methanol [CH3OH] 15 ppb 10 000 ppm Hydrogen sulphide [H2S] 300 ppb 300 ppm Hydrogen Chloride [HCl] 100 ppb 5000 ppm Hydrogen Fluoride [HF] 10 ppb 100 ppm Nitro methane [CH3NO2] 15 ppb 150 ppm Nitric Oxide [NO] 20 ppb 10 000 ppm Nitrogen dioxide [NO2] 10 ppb 5000 ppm Nitrous Oxide [N2O] 1 ppb 10 000 ppm Carbon monoxide [CO] 100 ppb 20 000 ppm Carbon dioxide [CO2] 20 ppm 30 000 ppm Sulphur dioxide [SO2] 50 ppb 5000 ppm Moisture [H2O] 500 ppb 40 000 ppm Formaldehyde [HCHO] 1 ppb 500 ppm Ammonia [NH3] 20 ppb 4000 ppm Hydrogen peroxide [H2O2] 100 ppb 1000 ppm Airoptic Ul. Rubiez 46 H 6 1 - 6 1 2 P o zn a n , P o l a n d Phone: +48 61 6272 128 Fax: +48 61 6272 129 Web: www.airoptic.pl E-mail: [email protected]
© Copyright 2026 Paperzz