CO2 Level Display Lua4RC Application 2 INTRODUCTION This script displays the CO2 level in ppm measured by the CO2 sensor on the main screen of the Room Controller. HARDWARE REQUIREMENTS Qty VT8600 Series Part Number Description v1.0.# or newer Room Controller SOFTWARE REQUIREMENTS Files File name Lua4RC_010_00.lua Version Comment Lua script, used in UP1(User Program 1) v.1.0 VISUAL ALERT When the CO2 level reaches “Max CO2” setpoint (default value is 1200ppm) two alternating messages shows on the Room Controller’s main screen (“High CO2 Alarm” and “CO2: *0000 PPM”). See Configuration menu screen 7 (7 /9), for “Max CO2” setpoint value. *actual CO2 level HIGH CO2 Alarm 7/9 Configuration Econo. min pos. 0% Econo. max pos. 100% Viconics Technologies Inc. 028-6097-00 Min fresh air 0 I/s Max fresh air 0 I/s Min CO2 800 PPM Max CO2 1200 PPM 9245 Langelier Blvd. Saint-Leonard, Quebec, Canada, H1P 3K9 I +1 514 321 5660 www.viconics.com March 2015 3 WIRING DIAGRAM 7 8 9 10 11 12 Common RC (24 Vac) UO 12 UO 11 UO 10 UO 9 - W2 RH BO 8 - W1 C (Common) BO 4 - G RC (24 Vac) BO 3 - Y1 BO 2 - Y2 BO 1 - Aux VT8600 Sensor 19 20 21 22 23 24 24 Vac Transformer 24 VAC UI 24 UI 23 - OS UI 22 - SS Common UI 20 - RS UI 19 - CO2 Common UI 17 COMM ON UI 16 BACnet REF BACnet - BACnet + 13 14 15 16 17 18 VT8300 Universal Inputs UI19 Viconics Technologies Inc. 028-6097-00 CO² Sensor 9245 Langelier Blvd. Saint-Leonard, Quebec, Canada, H1P 3K9 I +1 514 321 5660 www.viconics.com March 2015 4 FEEDBACK AND REFERENCES We hope that this application document, script example and associated information (the “information”) is valuable to you. Your use of this information, however, is at your sole risk. All information is provided “as -is”, without any warranty, whether express or implied, of its accuracy, completeness, fitness for a particular purpose, title or non-infringement, and none of the third-party products or information potentially mentioned in the work are authored, recommended, supported or guaranteed by Viconics Technologies inc.. Viconics Technologies inc. shall not be liable for any damages you may sustain by using/installing/modifying this information, whether direct, indirect, special, incidental or consequential, even if it has been advised of the possibility of such damages. Further, Viconics Technologies can not guarantee updates, sustaining or support for the information. If any kind of support is given in relation to this application note, it will be done “without prejudice” and with no implied warranty. DISCLAIMER We hope that this application document, script example and associated information (the “information”) is valuable to you. Viconics does not test the program using any actual equipment, and therefore, your use of this information is at your sole risk. All information is provided “as -is”, without any warranty by Viconics, whether express or implied, of its accuracy, completeness, fitness for a particular purpose, title or non-infringement, and none of the third-party products or information potentially mentioned in the work are authored, recommended, supported or guaranteed by Viconics Technologies inc.. All Lua Scripts are furnished free of charge. Viconics Technologies inc. shall not be liable for any damages you may sustain by using/ installing/modifying this information, whether direct, indirect, special, incidental or consequential, even if it has been advised of the possibility of such damages. Further, Viconics Technologies can not guarantee updates, sustaining or support for the information. If any kind of support is given in relation to this application note, it will be done “without prejudice” and with no implied warranty. Viconics Technologies Inc. 028-6097-00 9245 Langelier Blvd. Saint-Leonard, Quebec, Canada, H1P 3K9 I +1 514 321 5660 www.viconics.com March 2015
© Copyright 2026 Paperzz