TECHNICAL REVIEW: AIR PERMIT BY RULE Permit No.: Project No.: 119373 211056 Company Name: ExxonMobil Oil Corporation Unit Name: Beaumont Refinery Sru 1 GENERAL INFORMATION Regulated Entity No.: Customer Reference No.: Account No.: City/County: RN102450756 CN600920748 JE-0067-I Beaumont, Jefferson County CONTACT INFORMATION Responsible Official/ Primary Contact Name and Title: Technical Contact/ Consultant Name and Title: APD Reviewer: Mr. Robert Chavez PBR No(s).: 106.262 Project Type: Date Received by TCEQ: Date Received by Reviewer: Physical Location: Ms. Britney E Head Environmental Section Supervisorpermitting & Programs Mr. Jahi White Environmental Advisor GENERAL RULES CHECK Is confidential information included in the application? Is this registration certified? Is this an APWL site? Are there any upstream or downstream affects associated with this registration? Is planned MSS included in the registration? Are there affected NSR or Title V authorizations for the project? Is each PBR > 25/250 tpy? Are PBR sitewide emissions > 25/250 tpy? Are there permit limits on using PBRs at the site? Is PSD or Nonattainment netting required? YES Do NSPS, NESHAP, or MACT standards apply to this registration? Does NOx Cap and Trade apply to this registration? Is the facility in compliance with all other applicable rules and regulations? X Permit by Rule Application May 19, 2014 June 25, 2014 1795 Burt St Phone No.: Fax No.: (409) 757-6269 (409) 757-6899 Email: BRITNEY.E.HEAD@EXX ONMOBIL.COM Phone No.: Fax No.: (409) 757-6342 (409) 757-6905 Email: JAHI.Y.WHITE@EXXON MOBIL.COM NO X COMMENTS X X X X X If yes, what is the number(s): NSR#49138; several PBRs; Title V: O02000 (all not directly associated) Site has been to public notice N/A X X X X X This site is not one of the 28 named sources and emissions are below the federal significance as major sources levels. Therefore, PSD and NA review and netting are not required. NSPS VV, MACT CC Site is not in the HGA In compliance with all rules and regulations. Company is in compliance with Ch. 115 requirements DESCRIBE OVERALL PROCESS AT THE SITE ExxonMobil owns and operates the Beaumont Refinery SRU#1 located near Beaumont, Jefferson County. The refinery operates three Claus sulfur recovery units that covert a hydrogen sulfide feed to elemental sulfur and water. The recovered sulfur is sold as product. The three sulfur recovery units feed to two amine tail gas treating units for the removal of hydrogen sulfide. The exhaust gases from the tail gas units are sent to a thermal oxidizer. MSS emissions are included. TECHNICAL SUMMARY - DESCRIBE HOW THE PROJECT MEETS THE RULES PBR 106.262 Compliance Demonstration The emission point(s) associated with the facilities or changes to facilities are located at least 100 ft from the nearest off-site receptor. The total new or increase emissions will comply with the applicable hourly and annual emission limits as represented in the table below. There are no changes to or addition of any pollution abatement equipment. Visible emissions to the atmosphere, from any point or fugitive source, do not exceed 5.0% opacity in any six-minute period. This registration is not for authorization for construction or to change a facility authorized under another section of this chapter or under standard permit. Fugitives: Emissions are calculated using AP-42 emission factors. ESTIMATED EMISSIONS EPN / Emission Source VOC NOx CO PM10 PM 2.5 lbs/hr tpy lbs/hr tpy lbs/hr tpy lbs/hr tpy lbs/hr tpy Fugitives <0.01 0.03 TOTAL EMISSIONS (TPY): 0.03 MAXIMUM OPERATING SCHEDULE: Hours/Day Days/Week Weeks/Year 1 SO2 Other lbs/hr tpy lbs/hr tpy Hours/Year 8,760 TECHNICAL REVIEW: AIR PERMIT BY RULE Permit No.: Project No.: 119373 211056 Company Name: ExxonMobil Oil Corporation Unit Name: Beaumont Refinery Sru 1 TECHNICAL REVIEWER APD Reviewer: Mr. Robert Chavez PBR No(s).: 106.262 PEER REVIEWER FINAL REVIEWER SIGNATURE: See Hard Copy. PRINTED NAME: Mr. Robert Chavez Mr. Mark McDonald Ms. Anne M. Inman, P.E., Manager DATE: July 3, 2014 July 3, 2014 July 7, 2014 BASIS OF PROJECT POINTS POINTS Base Points: 1.5 Project Complexity Description and Points: Complete in <14 days 1.0 Technical Reviewer Project Points 2.5 Assessment: Final Reviewer Project Points Confirmation: 2
© Copyright 2026 Paperzz