Quanta System Light Series Laser

DERMATOLOGY AND
AESTHETIC MEDICINE
MEDICAL DIVISION
Light Series
Clinic in a System Dermatologic Platform
Multiple Wavelengths for the higher
Challenges in Laser Applications
PERMANENT HAIR REDUCTION
DERMATOLOGICAL VASCULAR LESIONS REMOVAL
INFLAMMATORY ACNE TREATMENTS
NON-ABLATIVE SKIN TREATMENTS
SKIN REJUVENATION PROCEDURES
ABLATIVE FRACTIONAL SKIN RESURFACING
(TWAIN 2940)
This brochure is not intended for the USA market. Certain Intended Uses/Configurations/Models/Accessories are not cleared for USA
Multiple Wavelengths for the higher Challenges in Laser Applications
Light Series has been developed to
satisfy the needs of doctors and clinics,
which today can perform a wide range
of dermatologic and aesthetic applications by using a single device, instead
of purchasing different lasers.
The system can include different laser
sources, such as a long pulsed Alexandrite (755 nm), a long and short
pulsed Nd:Yag 1064 nm, a long
pulsed Nd:Yag 532 nm and long
pulsed 1320 nm.
The large variety of available handpieces, with different variable and
fixed spot sizes, gives the possibility to
perform quick treatments by choosing
an appropriate fluence.
The laser emission parameters can
PWS
LIGHT SERIES & APPLICATIONS
Light A
Alexandrite (755 nm) long pulsed
laser.
Applications:
• Permanent hair reduction of I-IV
skin phototypes
• Benign pigmented lesions removal
Light B
Nd:Yag (1064 nm) short and long
pulsed laser.
Applications:
• Permanent hair reduction of every skin phototypes
• Dermatological vascular treatments
• Skin rejuvenation procedures
Light A* (Star)
This platform combines the Light A
and Light B performances.
It operates both at 755 and 1064 nm,
be easily set allowing effective treatments of any skin type.
Light Series, via a TWAIN connector,
can be upgraded with a Er:Yag 2940
nm and IPL handpiece enhancing the
treatment flexibility and versatility.
Due to its modularity and flexibility,
the NEW Light Series allows a quick
return of investment.
allowing the treatments as described
for the Light A and B, respectively.
Light C
Combination of Nd:Yag 1064 nm
short and long pulsed and Nd:Yag
532 nm long pulsed.
In addition to the treatments
performed with Light B, Light C is
indicated for treatments such as:
• Dermatological vascular lesions
• Skin rejuvenation
• Benign pigmented lesions
Light 4 V
Combination of Alexandrite (755
nm), Nd:Yag 1064 nm short and
long pulsed and Nd:Yag 532 nm
long pulsed.
A complete system which allows to
perform all the treatments indicated
with LIGHT A, LIGHT B and LIGHT C.
Ultralight
Combination of Q-Switched
Nd:Yag 1064 and 532 nm plus
Nd:Yag 1064 nm short and long
pulsed and Nd:Yag 532 nm long
pulsed, all in one unit.
The only system with 1064 + 532,
both Q-Switched and long pulsed
Nd:Yag laser, available on the market.
In addition to the treatments
performed with LIGHT C, this system
can be used for:
• Multicoloured tattoo removal
• Benign epidermal and dermal pigmented lesions removal.
Up to four wavelengths “all in one
unit” for the maximum flexibility.
OPTIONS
Twain IPL
Light Series can be equipped, at any
treatment time, with an optional IPL,
enhancing flexibility and versatility.
Applications:
• Permanent hair reduction
• Benign pigmented lesions removal
• Skin rejuvenation procedures
• Dermatological vascular treatments
• Inflammatory acne treatments
Twain 2940
Optional for each series is an Erbium
Yag laser all built into an handpiece.
Through this module both fractional
and traditional ablative skin
resurfacing procedures are possible.
This TWAIN represents the ideal
solution for fast skin texture and
wrinkle improvement.
Nd:Yag 1320 (Light A* Star)
Optional for any long pulsed
Nd:Yag of this Series is the 1320 nm
wavelength.
Due to its higher absorption by
water and great penetration into the
dermis, it is very effective for nonablative skin treatments.
Applications:
• Ablative Fractional Resurfacing
• Skin peels
• Removal of benign skin lesions
Twain IPL handpiece
2-5 mm variable spot size handpiece
Twain 2940 handpiece
Integrated optional contact skin cooler
CLINICAL RESULTS
PERMANENT HAIR REDUCTION
BENIGN PIGMENTED LESIONS
Courtesy of E. Bonizzoni MD
Before
After 5 treatments
Before
SKIN REJUVENATION
DERMATOLOGICAL VASCULAR LESIONS
Courtesy of P. Sbano MD
Courtesy of E. Bonizzoni MD
Before
MODEL Permanent hair
reduction After
After 3 treatment
Light A
Light B
Before
Light A *
Light C
After
Light 4V
Ultralight
Twain IPL Twain 2940 Nd:Yag 1320
•••••••
••••••
•••
•
• ••••••
•
•
•
Dermatological
vascular lesions Skin rejuvenation
Fractional ablative
rejuvenation
Benign epidermal
pigmented
lesions removal
Benign dermal
pigmented lesions removal
Tattoo removal
Surgical dermatology
VISIBLE AND INVISIBLE LASER RADIATION
Avoid eye skin exposure to direct or scattered radiation
Laser product: Class 4
Aiming beam: Class 3R
CAUTION - Laser radiation
DERMATOLOGY AND
AESTHETIC MEDICINE
MEDICAL DIVISION
Light Series
MODEL Light A Light B
Light A*
Laser AlexandriteNd:Yag
Pulse width [ms] 2-100 2-100 0.3-1
2-100 3-300 0.3-1
3-300 0.3-1
up to 25
Repetition rate [Hz] up to 2 up to 2 up to 7 up to 2 up to 2 up to 7 up to 2 up to 7 1
up to 16
up to 14
up to 6 up to 16
up to 14
up to 6 up to 14
up to 6 up to 6
up to 123 @ 6 mm >800 @ 2 mm
up to 30
@ 5 mm
up to 123 @ 6 mm
>800 @ 2 mm
up to 30 @ 5 mm
>800 @ 2 mm
up to 30 @ 5 mm
up to 95
@ 2 mm
[mm] 755 Nd:Yag
[nm] Max fluence [J/cm2] 1064 long pulse1064 short pulse
Nd:Yag
Wavelength Spot size 755 Light C
1064 long pulse 1064 short pulse 1064 long pulse 1064 short pulse
532
contact or air integrated with the handpiece (1)
Skin Cooler
Electrical requirements
230 V ac; 16 A; 50/60 Hz
Dimensions and weight
480(W) x 900 (D) x 930 (H) mm; 90 Kg
(1) Optional
MODEL Light 4 V Laser Alexandrite Wavelength [nm] 755 Pulse width [ms] 2-100 Ultralight
Nd:Yag
Nd:Yag 1064 long pulse 1064 short pulse
2-100 0.3-1
532 Q-Switched Nd:Yag
1064 long pulse 1064 short pulse
up to 25 2-100 0.3-1
532 1064532
up to 25 6 ns
6 ns
[Hz] up to 2 up to 2 up to 7 1
up to 2 up to 7 1
up to 10
up to 10
[mm] up to 16
up to 14
up to 6 up to 6 up to 14
up to 6 up to 6 up to 5x5
up to 5x5
[J/cm2] Max fluence up to 123
@ 6 mm
>800 @ 2 mm
up to 30 @ 5 mm
up to 95 @ 2 mm
>800 @ 2 mm up to 30 @ 5 mm
up to 95 @ 2 mm
22
@ 2x2 mm
11
@ 2x2 mm
Repetition rate Spot size
Skin Cooler contact or air integrated with the handpiece (1)
Electrical requirements
230 V ac; 16 A; 50/60 Hz
Dimensions and weight
480(W) x 900 (D) x 930 (H) mm; 90 Kg
(1) Optional
OPTION Source
Twain 2940 Twain IPL
Er:YagIPL handpieces
Wavelength [nm] 2940
Pulse width [ms]
0.3 - 1 Spot size
Max Fluence Repetition rate
[mm] 2, 4, 9, fractional
[J/cm2] 95
[Hz] up to 6
650-1200
625-1200
590-1200
570-1200
550-1200
400-1200
5 - 240 48x13 mm2 - 25x13 mm2 up to 30 0,5
0,5 0,5 0,5 0,5 0,5 Nd:Yag 1320 (2)
Nd:Yag
1320
5 - 10
8 - 10
up to 20 @ 8 mm
up to 5
(2) Nd:Yag 1320 option available for Light A*, Light B, Light C, Light 4 V
Quanta System products are manufactured according to the International standards and have been cleared by the most important International notified
bodies. The Company is EN ISO 9001:2008 and EN ISO 13485:2012 certified. Quanta System S.p.A. was founded in 1985 and belongs to the EI. En. Group
(a public company listed in the Star segment of the Italian Stock Exchange) since January 2004. The company, divided into three business units (medical,
scientific and industrial) is specialized in manufacturing of laser and opto-electronic devices.
Quanta System S.p.A
Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy
Tel. +39 0331.376797 - Fax +39 0331.367815
[email protected]
www.quantasystem.com
QTS-LIGHTSERIES-rev005 - ROTW
Note: National local authorities may put restrictions to the parameters indicated in the above table, or may limit or remove certain intended uses.
Specifications are subject to change without notice.