INTRUDER ALARM CONTROL EQUIPMENT
Banham
Range of Control Equipment
(with Downline Diagnostic Facility)
Control Panel Code
G24
Grade 2 Class 2
G76
Grade 3 Class 2
G280
Grade 3 Class 2
Alarm Points (In Panel)
8
8
8
Max Number of Alarm Points (Fully Expanded)
24
76
280
Remote Keypads/TMZ Modules
Alarm Point Expansion Modules (Wireless / Wired)
4
1
9
7
16
36
Downline Diagnostic/Maintenance Facility
yes
yes
yes
Full Proximity/Tag/Keyswitch or Shunt Lock Setting
yes
yes
yes
Individual Tag Users
15
100
500
Number of Door Access Controls
3
5
15
Programmable Part/Night Sets
3
7
14
Independent Area Sets
4
8
14
Event Log Memory (events)
500
2000
2500
On Board Programmable Outputs
yes
yes
yes
1.5 amp
2.5 amp
2.5 amp
On Board Power Supply
Tag Readers in Place of Remote Keypads
Full Standby Battery Backup
3
15
15
yes
yes
yes
Panel dimensions: G24: H297 x W250 x D82 G76/G280: H390 x W305 x D100
F22K
C22K
E.TAG
Flush mounted Xpander range
keypad incorporating full English
text on a 16 character LCD
providing full proximity keyfob/
card operation. Available in either
polished or satin, brass or chrome.
Grade 2/3 Class 2.
Back box H105 x W142 x D35
Cover plate H125 x W158
Standard Xpander range
keypad (surface mounted)
incorporating full English text on
a 16 character LCD providing full
proximity keyfob/card operation.
Grade 2/3 Class 2.
H100 x W145 x D35
Keyfob designed to be placed on
a keyring and be programmed to
enable operation of an intruder
alarm keypad (3 supplied
per system).
Grade 2/3 Class 2.
26W x 55L
ZEM/TMZ
ANNO HYBRID ZEM
RPBB
SUR
8/2 alarm point expansion
module incorporating 4/1
programmable outputs.
Grade 2/3 Class 2.
H173 x W126 x D31
28 wireless alarm point expansion
module suitable for connecting to the
G76 xpander range and above.
Images of detector
equipment overleaf.
Double push portable
remote panic button.
Grade 2 Class 2.
range approx 100m
subject to environment.
H166 x W46 x D30
Device for setting and unsetting
a defined area with onboard
fault indicator lights.
Grade 2/3 Class 2.
H100 x W40 x D24
RX2
ETR
PSU/ZEM
2 channel remote receiver used in conjunction
with the Banham double push remote panic
button transmitter.
Grade 2/3 Class 2.
H103 x W317 x D32
External quality card/TAG reader with
2m of connection screened cable
manufactured to IP66 Standard.
Grade 2 Class 4.
H85 x W85 x D20
8 alarm point expansion modules incorporating a local psu.
CAC
Door access control unit which fully integrates with the
Xpander range of intruder control equipment. This facility
provides the following options:
• Connection for either internal or external readers.
• Lock release facility which will accommodate most
PS1
PS1-4
1 amp power supply unit
housed in a metal box to provide
additional auxiliary current, with
internal mains and battery fault
indicator lamps.
Grade 2/3 Class 2.
H388 x W240 x D86
1·4 amp power supply unit
housed in a metal box to provide
additional auxiliary current, with
internal mains and battery fault
indicator lamps.
Grade 2/3 Class 2.
H335 x W363 x D90
scenarios ranging between 12v, 24 DC through to
AC mechanisms.
• Key/Card fob control which is compatible with the
intruder alarm system.
• Lock open timer between 0-250 seconds.
• Door open timer between 0-250 seconds.
• Local alarm output facility for audible warning.
• Request to exit button.
• On board 2.5 amp power supply facility.
Grade 2 Class 2.
H390 x W305 x D100
DETECTION EQUIPMENT
BAN CXPIR
BAN 36ODT
BAN TMD
Commercial quality PIR detector
with super quad logic and
anti-masking technology.
Grade 3 Class 2.
H115 x W70 x D52.3
Detection area 15m x 15m
BAN 815DT
Combined PIR & PIR microwave detector
with anti mask facility. This unit can
provide a sequential confirmed signal.
Grade 3 Class 2.
12m x 12m (detection pattern)
H180 x W75 x D40
Detection area 15m x 13m
BAN FLEXGUARD
Dual technology detector incorporating
both PIR and microwave technology and
anti mask technology. This device
is suitable for particularly harsh
environments and allows the microwave
technology to be isolated when unset.
Grade 3 Class 2.
H128 x W65 x D45 15m x 85 deg
AX100S
BAN BX80
BAN T1PIR
Mini infra red photoelectric beam.
10m internal device.
H15 x W16 x D12
Mounting plate. H42 x W24 x D2
Controller. H94 x W45 x D29
BAN SQPIR
FC
SHATTERSWITCH
HC
Heavy duty magnetic
reed contact.
Grade 2/3 Class 2.
L44 x W34 x D10
SC
Acoustic sensor with dual technology.
Grade 2 Class 2.
Range: 2m
H33 x W100 x D24
SM
NOTE: Please contact your security design consultant for
further information if required. All measurements in mm
unless otherwise stated.
Intelligent PIR detector with
quad logic.
Grade 2 Class 2.
H112 x W66 x D46
Detection area 15m x 15m
Advanced acoustic sensor with
pattern recognition technology.
Grade 2 Class 2.
H100 x W56 x D20
Seismic vibration detector.
Grade 3 Class 2.
Range: 2m
H85 x W23 x D26
Static double push panic
button (surface mounted)
available in brass, stainless
steel or white.
Grade 2/3 Class 2.
H83 x W65 x D30
BAN T2PIR
SHATTERPRO
VIBRATION SENSOR
PANIC BUTTON
Twin beam infra red
photoelectric beam.
H167 x W67 x D66.5
100m internal 40m external
Standard PIR detector with quad logic.
Grade 2 Class 2.
H97 x W62 x D44
Detection area 12m x 12m
Sequential confirmation detector with
quad logic utilising two independent
detection alarm points which combined
provide a detection coverage area of
12m x 12m or 18m x 18m.
Grade 2 Class 2.
H125 x W72 x D44.5
Detection area 12m x 15m
Flush magnetic reed contact.
Grade 2/3 Class 2.
20mm dia x 25mm dia flush x D1
AX130T
External quality infra red detector that
provides a multi layered horizontal barrier
that projects either side of the device
(12 metres per side).
Grade 2 Class 4.
H232.7 x W55 x D68.7
PMB
Dual technology detector integrating
a PIR detector with quad zone logic and
microwave technology which combine
to provide a greater degree of immunity
to false alarms.
Grade 2 Class 2.
H125 x W70 x D48.6
Detection area 12m x 12m
Dual technology detector integrating
PIR and ultrasonic detection coverage
to provide a greater degree of immunity
to false alarms.
Grade 2 Class 2.
H123 x W72 x D57
Detection area 12m x 12m
Mounting height: min 2.4m x 7.5m dia max 4.5m x 9m dia
Dual technology break
glass detector.
Grade 3 Class 2.
H98 x W62 x D21.8
Infra red photoelectric
beam (surface).
H196 x W78 x D83
Flush version. H114 x W70 x D30
Range: 60m internal
30m external
BAN D115
BAN P9DT
Ceiling mounted dual technology
detector integrating PIR and
microwave technology with anti
mask facility to provide a greater
degree of immunity to false alarms.
Grade 2/3 Class 2.
TP
Ionisation/Optical
low profile
smoke detector.
100 dia x D55
Surface magnetic reed contact.
Grade 2/3 Class 2.
L60 x W14 x D14
HT
Fixed temperature
heat detector
above 60º C.
100 dia x D55
PIR - Passive infra red technology,
which measures temperature change.
Rate of rise
heat detector
rapid increase in
temperature.
100 dia x D55
DUALTEC - Combines passive infra red and microwave technologies,
which measure temperature change along with movement.
WARNING EQUIPMENT
SELF-ACTUATING SIREN
Shield shaped self-actuating siren unit with a polycarbonate translucent cover
incorporating a high powered strobe unit and twin pulsing red comfort LED’s
including standby battery. Option of white or black covers.
Grade 2/3 Class 4.
(120dB at 1m) H285 x W295 x D65
ISAS
ER
Mini intra integrated strobe and
self actuating siren device enclosed
in a polycarbonate housing with a
strobe lens including standby battery.
Grade 2/3 Class 4.
(115 dB at 1m) H176.5 x W112.5 xD44.9
16 ohm internal sounder device.
Grade 2/3 Class 2/3.
(12w) H110 x W110 x D58
FIRE SOUNDER
ISIR
On-board fire sounder designed
to be mounted on to a fire detector.
(86 dB at 1m) dia 106 x D25
105 dB at 1m internal
warning device.
Grade 2 Class 2.
H55 x W107 x D32
ANNO 85 WIRELESS & HYBRID (WIRELESS & WIRED)
INTRUDER ALARM SYSTEMS
If you are concerned about the detrimental effect a hard-wired security alarm could have on the aesthetics of your
property then our wireless burglar alarm could provide the ideal solution. It also allows for additional alarms to be
added to out-buildings such as garages and sheds.
For those looking for a wireless alarm system, our wireless range provides a number of advantages, including
a wireless portable panic button and wireless external self actuating siren.
We can supply shock sensors, movement detectors and even acoustic detectors to provide a complete security
package. We can also implement an individual key fob system to improve the level of access control you have over
your property.
For clients who have existing systems that need to be taken over, we can also provide a hybrid solution of wired
and wireless equipment.
All of our security alarm systems can be designed with your specific requirements in mind, while we will also liaise
with your insurers to ensure you comply with their expectations. We also put particular emphasis on meeting the
current ACPO and European Standards, and the quality of our service has been recognised with the Metropolitan
Gold Award for Alarm Performance & by the NSI.
Control Panel
with Built-In Sounder
Panel Dimensions:
H160 mm x W220 mm x D55mm
External Wireless
Self-Actuating Siren
with Flashing Strobe
H285mm x W282mm x D63mm
Magnetic Reed Contact
Remote Keypad with Blue LCD Display
H115 mm x W30 mm x D35mm
(wireless)
H100 mm x W145 mm x D35mm
(always hardwired)
Grade 2 Wireless Digital
Passive Infra Red Movement Detector
H117 mm x W69 mm x D50mm
(wireless)
Wireless Seismic Vibration Sensor
H115 mm x W30 mm x D35mm
(wireless)
Wireless Optical Smoke Detector
with Built-In Sounder
120mm Dia x D53mm
(wireless)
Double Press Handheld Wireless Personal
Attack Hold-Up Alarm Digital Transmitter
H60 mm x W40 mm x D15mm
Keyfob
H54 mm x W26 mm x D2mm
Handheld Remote Digital Setting Device
H60 mm x W40 mm x D15mm
BANHAM AFTER SALES SERVICE
Annual Routine Maintenance Inspection
All Banham Intruder alarms can be designed to comply with BS 8243:2010,
EN50131-1/PD 6662 and the requirements laid down by the National Security
Inspectorate (NSI). It may be a requirement of your insurance policy that your
system is covered by a routine maintenance contract, for which you may be
eligible for a discount on your contents insurance cover. Depending on your
requirements, we offer a number of contract options:
is available 24 hours a day with attendance within 4 hours if required. All
our engineers are equipped with onboard portable computers, which relay
real-time information relating to your service requirements. Details of the
visit are then instantly relayed back to our control centre.
AN IMPORTANT FEATURE OF THE INSPECTION IS THE CHECKING
OF THE BATTERIES, AND CONTACTS WITHIN THE SYSTEM,
WHICH ARE REPLACED AS NECESSARY FREE OF CHARGE.
1 maintenance visit a year:
Systems without remote signalling (bells only) require just one visit.
2 maintenance visits a year:
If your system in connected to the Alarm Receiving Centre (ARC) for Police
response, it is a Police and NSI requirement that the system must be subject
to two inspection visits per annum. (One can be remote providing the system
is not Grade 3).
Automatic Remote Maintenance (ARM)
Using ARM Banham can verify that your entire security system is fully
functional providing complete peace of mind in your security arrangements.
You can choose one of your two annual inspections to be carried out
using ARM.
Secure and Convenient
ARM enhances your security by constantly checking on the electrical status
and functional capability of the alarm system.
Formal reporting
At a pre-set time, the control panel will call the host server and upload a full
report on the status of your system. This report may be printed and copied
to you, if required. Regular reporting by your alarm system to Banham takes
the inconvenience out of service visits, and ensures the system is always
operating at its peak performance level.
Optional extended warranty:
This contract provides free service for the maintenance of intruder alarm
system 24 hours a day, to include parts and labour, and a lifetime guarantee
on systems connected to the ARC on a full Police monitored contract (subject
to conditions).
What is involved in your maintenance inspection?:
Calls are pre-booked by Banham and notified well in advance to give clients
the opportunity to contact us, if the pre-arranged date is inconvenient.
During the maintenance visit, the intruder alarm is tested to ensure that
it is functioning correctly. Any developing fault found would be rectified
accordingly at no charge other than for replacement components which are
outside the 12 month guarantee period. Our emergency service department
Full Signalling and Warning Analysis
The correct operation of signalling equipment to the Alarm Receiving Centre
is reassured along with a full test of the external sounders, initiated by the
user.
Latest Technology
ARM software incorporates both BS 8243:2010 and EN 50131-1:2006 / PD 6662
to conform with the current Police and European requirements on false alarm
reduction and system design.
Detector performance analysis
All detectors are regularly checked to ensure your complete protection.
Regular reminders to walk-test the system are given, which includes an
automated system health check.
THE BANHAM GUARANTEE:
We are the only alarm service provider to guarantee not to raise your annual maintenance and monitoring charges above the annual rate of inflation, and
offer a lifetime guarantee on any system connected to the ARC on a full police monitored contract.
Charges: None of our communication devices utilise premium rate lines. Technical phone support and remote resets are free for maintained customers.
Monitoring Options
Banham provides 24 hour monitoring for all types of alarm systems
through our own in-house Alarm Receiving Centre (ARC). We monitor
systems including Intruder, Fire, CCTV, Panic, Freezer, Medical, Power Failure,
Vaults, Opening and Closing Management, Flood Warning, Access Control,
Ambient Temperature, Humidity Level, Machinery monitoring, Controlled
Environment Monitoring. You can choose your own level of response:
1) Fully Monitored System with keyholder and 24 hour Police response:
If your alarm system is activated and a confirmed signal is received by our
ARC (subject to the response level), the Police will be automatically notified
and will respond. A confirmed signal means that the system must generate
two independent alarm activations before the call can be passed on for a
Police Response. Our ARC controllers will contact the premises to verify the
activation. If the private passcode for the premises cannot be confirmed
within a set time, the Police response will be confirmed to continue. The ARC
will also contact keyholders nominated by the client to advise of an alarm
activation of any kind.
2) Keyholder Response only:
Clients who do not require Police response but would like the added
security of either themselves or their nominated keyholders being
contacted following an alarm activation, can have the system more-or-less
designed to meet their own requirements, subject to insurer’s approval if
necessary. Temporary monitoring is also an option, but is only available
through a digital communicator connection. If you are unable to provide
private keyholders, Banham can undertake this service through their own
professional keyholding company CMS Keyholding. Our team of keyholders
on motorbikes are available 24 hours a day, 365 days a year and are ready to
respond to any emergency situation.
3) Keyholder Response with PAB to Police:
Clients who do not want their system fully connected to the Police but who
want the extra peace of mind of being able to reach the Police in an absolute
emergency can opt to have just their Panic Button connected for a Police
response - this option is only available through a Digital Communicator
connection. (Note: Banham can also provide ‘bells only systems’ with a Panic
Button only to the Police, subject to a telephone line being connected).
ALARM RECEIVING CENTRE (ARC)
Communication Devices
Choose what type of communication link
your alarm system has to our ARC.
Banham provides 24 hour monitoring for
all types of alarm systems.
Business & Offices
Residential
DUV/G
Dualcom Vodafone is a dual path
communication link between your
property and the ARC. The normal
landline (any analogue service
provider) and also the Vodafone/
PAKNET/GPRS radio network combine
to provide an increased level of
security. This is actively promoted
by both Crime Prevention Officers
and insurance companies alike. The
unit requires an aerial, the location of
which is subject to an engineer site
environment test.
Keyholding
Response
Emergency
Services
EM2
EMIZON IP is a dual path alarm signalling
service utilising a broadband connection.
EMIZON IP continuously monitors the
connection between the intruder alarm
and the Alarm Receiving Centre. In the
event of the IP network path being
compromised either accidentally or
deliberately, then signalling will be sent
via the wireless GPRS Network.
24hr Engineer Response
Police Response
SIA 3
As standard at installation all communications systems are installed with SIA 3 communication
protocol which provides an itemised audit trail of events following an activation.
This service is free for the first year with continuation subject to client approval thereafter.
DC
Digital Communicator is a single path
communication link between your
property and the ARC, which can utilise
any network provider, either an existing
standard analogue broadband line or an
exclusive dedicated out going only line
for increased security.
CA
BT Redcare offers the same features as
Digital Communicator but if a line fault
occurs, a warning will be displayed in our
ARC, which is then subject to Keyholder
response only unless preceded by an
intruder activation. Please note however
that this option can only be used with a BT
analogue line.
GPRS
Single Path GPRS Communicator utilising a
world sim for improved network coverage.
Ideal for locations where a PSTN or IP wired
infrastructure is not available.
CMS Keyholding
Keyholding / Alarm Response
Clients who do not require Police response but would like the added security and
peace of mind of either themselves or their nominated keyholder being contacted
following an alarm activation, can have the system more-or-less designed to meet
their own requirements, subject to insurer’s approval if necessary. Temporary
monitoring is also an option. The Police policy described opposite is therefore not a
requirement. For further details of the available options, our security surveyors will
be able to advise you.
Monitored Alarms with Keyholder Response Only
With monitored systems, the ARC will contact keyholders nominated by the client
to advise of an alarm activation of any kind. If you are unable to provide private
keyholders, Banham can undertake this service through their wholly owned
subsidiary, CMS Keyholding (Tel: 020 7627 0344). CMS provide a team of professional
keyholders on motorbikes available 24 hours a day, 365 days a year ready to respond
to any emergency situation.
Tel: 020 7627 0344
INFORMATION RELATING TO THE DESIGN AND
INSTALLATION OF YOUR INTRUDER ALARM SYSTEM
Compliance with the ACPO Policy BS 8243:2010
In an effort to reduce the number of wasted Police visits to sites
following false alarms, the Association of Chief Police Officers (ACPO)
have introduced certain design and operational requirements in
order to help relieve Police resources.
In brief, these requirements cover three separate aspects of the
intruder alarm, which are as follows:-
Compliance with European Standards
EN 50131-1:2006 / PD 6662 (BS 8243:2010)
From 1st June 2012, systems that require NSI Certification
must be designed and installed to comply with
BS 8243:2010 EN 50131-1:2006 / PD 6662. This will include
the requirement for an insurance risk assessment to be
undertaken, which will assist in determining the grade of
the system and equipment required for the premises.
(BS 8243:2010 Released 2010
implemented in July 2012)
Alarm Unsetting
Statistics suggest that 94% of Police visits to site are generated by
incorrect operation of the alarm keypad. In order to combat this
problem ACPO insist that all systems must be unset via a single
action method, such as a keyfob or keyswitch. We recommend the
proximity keyfob as being the most user friendly and efficient of the
available options. Clients who are unconvinced that this requirement
is workable for them and who at point of survey insist upon designing
the system for code number operation must understand that:A Where an intrusion occurs via a final exit, all means of alarm
confirmation will be isolated. This means that the whole property
will be vulnerable with the only action available being that of
keyholder response.
B Systems of a similar design, but with keyfob operation, will only
have entry/exit routes devices disabled. All other devices are then
available to provide the first and second activation necessary to
support the confirmed alarm signal.
For 8 consecutive years Banham have
been awarded the coveted Metropolitan
Police Gold & Silver Awards for the
low number of false Police activations,
highlighting the quality of our installations.
Confirmed Alarm Signals
Since the introduction of the October 2001 ACPO Policy all new
intruder alarm systems connected to the ARC must be designed to
provide a confirmed alarm signal before the Police will respond.
This means that the system must generate two independent
alarm activations before the call can be passed to the Police as a
confirmed alarm. Banham achieve a confirmed alarm signal by using
a sequential format i.e. two devices activating in sequence. We find
this to be the most user friendly means of conforming with the ACPO
Policy BS 8243:2010.
Police Response to Intruder Alarms
ACPO categorise all monitored intruder alarms into the following
response levels:Immediate Response.
The Police will attend on the assumption that an offence is taking
place, but against a background of competing urgent calls and
available Police resources.
No Police attendance.
Following two false Hold up / Panic Alarms or three false confirmed
Intruder Alarms within a 12 month period, the occupier will be
advised by the Police that the system will have response withdrawn
to this particular signal (Hold up / Panic or Intruder Alarm). Response
will be reinstated once the following conditions have been met.
The Police will require a written application from Banham Alarms
supported by evidence that the system has been free of false
alarms for three (3) months, and the cause of the false alarms has
been rectified.
As an alternative to the lack of Police response and subject to
approval by insurers, it is possible to employ a professional
keyholding company in the event of alarm activations and in the
absence of Police response. For further details please contact our
subsidiary company, CMS Keyholding on 020 7627 0344. They can
offer a guaranteed response with the added peace of mind that
whatever the circumstances on site, their Key Guard will co-ordinate
matters and ensure the continued security of the premises.
ACPO demand that a site safety hazard letter is signed and returned
by the client advising them of any known or potential site hazards
which may endanger the safety of any officers who attend site.
Application for a Unique Reference Number (URN) will begin once
this has been received together with payment of the Police charge.
ENVIRONMENTAL RESPONSIBILITIES:
The Banham Group understand the importance of sustainability & protecting the environment. All Banham Group companies are committed to
ensuring that their operational and business responsibilities are in compliance with current British & EU legislation, including the safe dismantling &
disposal of equipment such as batteries.
BANHAM ALSO PROVIDE
THE FOLLOWING SERVICES & PRODUCTS
EMERGENCY LOCKSMITHS
•
REGISTERED KEY DOOR LOCKS
•
WINDOW LOCKS
•
SECURITY GRILLES
•
COLLAPSIBLE GATES
•
ROLLER SHUTTERS / GARAGE DOORS
•
SAFES AND GUN CABINETS
•
SECURITY DOORS
•
FIRE ALARMS
•
AUDIO ENTRY SYSTEMS
•
VIDEO ENTRY SYSTEMS
•
ACCESS CONTROL SYSTEMS
•
CCTV SYSTEMS WITH DIGITAL RECORDING / ARC MONITORING / REMOTE VIEWING
•
KEYHOLDING / ALARM RESPONSE SERVICE
•
KEY DELIVERY SERVICE
•
CLOSE PROTECTION AND SURVEILLANCE
•
RAID CONTROL SYSTEMS
•
DNA DETECTION SYSTEMS
•
CONCIERGE SERVICES
South of England Showroom
20 Chertsey Street, Guildford, Surrey GU1 4HD
Tel: 01483 301400 Fax: 01483 302323
Head Office & Administration
10
Pascal Street,
20 Thornsett
Road,London
London, SW8
SW18 4SH
4EF
Tel: 020 7622 5151 Fax: 020 7498 2461
Web: www.banham.co.uk
Email: [email protected]
Thames Valley Showroom
36 High Street, Maidenhead, Berks SL6 1QE
Tel: 01628 784151 Fax: 01628 784926
Central London Showroom
233/235 Kensington High Street, London W8 6SF
Tel: 020 7622 5151 Fax: 020 7376 1232
Also at:
Brighton Tel: 01273 818311
Winchester Tel: 01962 870999
North London Showroom
51 Golders Green Road, Golders Green NW11 8EL
Tel: 020 8905 5405 Fax: 020 8209 0042
CERTIFICATE NO. 113
CERTIFICATE NO. SP203-001279
CERTIFICATE NO. CFSA 006