LP SERIES-General Purpose LP2-300 (2V300AH) Specification Nominal Voltage 2V Nominal Capacity(10HR) 300.0AH Dimensions 170±2mm (6.69 inches) Length 150±2mm (5.91 inches) Width 328±3mm (12.91 inches) Container Height Total Height (with Terminal) 350±3mm (13.78 inches) Approx 17.7 kg (39.0lbs) Approx Weight Terminal T11 Container Material ABS Rated Capacity 316.0 AH/15.8A 300.0 AH/30.0A 261.0 AH/52.2A 226.8 AH/75.6A 182.1AH/182.1A (20hr ,1.80V/cell,250C/770F) (10hr,1.80V/cell,250C/770F) (5hr,1.75V/cell,250C/770F) (3hr,1.75V/cell,250C/770F) (1hr,1.60V/cell,250C/770F) Max. Discharge Current 2400A (5s) Internal Resistance Approx 0.9mΩ Operating Temp.Range Discharge : -15~500C (5~1220F) Charge : 0~400C (32~1040F) Storage : -15~400C (5~1040F) Nominal Operating Temp. Range Cycle Use 0 Applications Tele-communication central station (wired or cellular) Power system communication, military communication, etc. Network communication including: data transmission, television signal 0 25±3 C (77±5 F ) transmission, etc. Initial Charging Current less than 90.0A.Voltage Uninterruptable Power System 2.4V~2.5V at 250 C(770 F)Temp. Coefficient -5mV/0C (UPS- for Telecom) No limit on Initial Charging Current Voltage Standby Use 2.25V~2.3V at 250 C(770 F)Temp. Coefficient -3mV/0C 103% 40o C (104o F) o o 25 C ( 77 F) 100% 0o C ( 32o F) 86% Leoch LP series batteries may be stored for up to 6 months at 250 C(770F) and then a freshening charge is required. For higher temperatures the time interval will be shorter. Capacity affected by Temperature Self Discharge VdS t est ed 9 Germany Constant Current Discharge (Amperes) at 25 0C (77 0F ) F.V/Time 15min 20min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h 1.85V/cell 309.0 278.1 230.0 182.4 149.7 89.9 69.5 57.1 48.6 42.5 34.2 28.7 15.2 1.80V/cell 351.0 309.6 246.8 191.9 159.0 94.9 72.9 59.6 50.6 44.4 35.5 30.0 15.8 1.75V/cell 385.6 333.7 261.4 201.8 165.9 98.8 75.6 61.7 52.2 45.4 36.2 30.3 15.9 1.70V/cell 411.6 356.9 274.3 209.4 171.7 101.7 77.6 63.0 53.1 46.2 36.8 30.6 16.1 1.65V/cell 433.8 374.5 287.7 218.5 177.9 104.8 79.3 64.4 54.2 47.0 37.3 31.0 16.3 1.60V/cell 454.8 388.4 297.6 224.4 182.1 107.3 81.0 65.3 55.0 47.7 37.8 31.4 16.5 Constant Power Discharge (Watts) at 25 0C (77 0F ) F.V/Time 15min 20min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h 1.85V/cell 585.1 528.9 439.6 350.7 289.6 174.9 135.8 111.9 95.7 83.9 67.9 57.0 30.3 1.80V/cell 656.1 582.7 467.9 366.5 305.8 183.6 141.8 116.5 99.3 87.3 70.3 59.6 31.3 1.75V/cell 710.6 620.9 491.7 383.1 317.7 190.5 146.7 120.1 102.0 89.1 71.4 60.1 31.6 1.70V/cell 750.7 658.3 511.6 394.8 327.1 195.3 150.0 122.2 103.5 90.5 72.5 60.7 31.9 1.65V/cell 781.3 683.4 532.7 409.7 337.0 200.3 152.6 124.4 105.3 91.8 73.3 61.3 32.2 1.60V/cell 805.6 700.7 545.5 416.8 342.5 203.8 155.1 125.6 106.4 92.8 74.1 61.9 32.6 Specifications subject to change without notice. 1 Dimensions T11 Terminal Unit: mm 330±3 339±3 350±3 7 150±2 φ20 M8 110±2 170±2 Discharge Characteristics 2V Battery (V) Float Charging Characteristics Temperature:25 0 C(77 0 F) Charging Current Charge Volume 2.16 Charging Voltage 0.10CA-2.25V/cell (XCA) % 0 temperature25 C (V) 2.00 Terminal Voltage(V) 0.25 120 110 1.84 0.205C 0.4C 1.68 2.33 90 80 Charge Voltage (Constant 2.25v/cell) 0.15 2.17 70 60 0.6C 1C 1.52 After 50% Discharge 0.10 50 2.00 40 1.36 1 2 6 4 8 10 After 100% Discharge 30 2C 40 20 2 60 4 6 8 10 H Min 0.05 20 10 0 20 2.50 Charged Volume 0.20 100 0.1C 0.0525C 1.83 Charging Current 0 0 8 4 Discharge Time 12 16 20 32 28 24 36 40 Charging Time(hours) Effect of Temperature on Long Term Float Life Temperature Effects in Relation to Battery Capacity 120 Capacity(%) Float Life(year) 0.1CA 0.17CA 100 0.25CA 80 60 40 14 12 10 Charging voltage : 2.25V/cell 8 5 2 20 0 -20 0 -10 10 20 30 40 50 20 68 60 30 86 Temperature( C) Testing condition Discharging:current 0.17CA (FV 1.7V/cell); Charging:current 0.25C max, voltage 2.45V/cell; Charging volume:125% of discharged capacity. Remaining Capacity(%) 100 Capcity(%) 80 60 0 0 50% DOD 400 600 800 1000 A 250C B 60 300C 400C 40 C 20 0 30% DOD 100C 80 2 6 4 8 12 10 Storage Time(Months) Ambient Termperature: 25oC (77oF) 200 C F O 100 120 20 0 Self Discharge Characteristics Cycle Life in Relation to Depth of Discharge 100% DOD 50 122 Battery temperature 0 40 40 104 A No supplementary charge required (Carry out supplementary charge before use if 100% capacity is required.) B Supplementary charge required before use.Optional charging way as below: 1.Charged for above 3 days at limted current 0.25CA and constant volatge 2.25V/cell. 2.Charged for above 20hours at limted current 0.25CA and constant volatge 2.45V/cell. 3.Charged for 8~10hours at limted current 0.05CA . C Supplementary charge may often fail to recover the capacity. The battery should never be left standing till this is reached. 1200 Number of Cycles Sales Office China sales office: HongKong sales office: Singapore sales office: North America sales office: Europe sales office: Add:5th Floor,Xinbaohui Bldg.,Nanhai Blvd., Workshop C, 33/F, TML Tower, Add: No. 1 Tech Park Crescent, Add: 19751 Descartes, Unit A, Add: 9B Wheatstone Court. Waterwells Nanshan,Shenzhen, China. 518052 No. 3 Hoi Shing Road, Tsuen Wan, Singapore 638131 Foothill Ranch, CA 92610, USA Business Park, Gloucester, GL2-2AQ, Tel: +86-755-86036060 (100 lines) New Territories, Hong Kong Tel: +65 68636078 Tel: 949-588-5853 UK United Kingdom Fax: +86-755-26067269 Tel: +852 35786666 Fax: +65 68636079 Fax: 949-588-5966 Tel: +44(0) 1452 729428 / 1452 729696 E-mail:[email protected] Fax: +852 21170016 Email [email protected] E-mail: [email protected] Fax: +44 (0)1452-690125 Http://www.leoch.com E-mail: [email protected] Http://www.leoch.com Http://www.leoch.com E-mail: [email protected] Publication No.:LB-LP-7-17 2
© Copyright 2026 Paperzz