Model 600/650 Pulse Output Transmitter Technical Brief The Data Industrial Model 600 (housed) and 650 (unhoused) Pulse Output Transmitter is a compact electronic device that receives input signals from any Data Industrial, non-magnetic Impeller Flow Sensor. They accumulate and “divide” it to produce an output pulse scaled to a user selectable unit of measurement; i.e. 1 pulse per gallon, 1 pulse per cubic foot, 1 pulse per 10 liters. The scale is field set from an internal 12 position dip switch. No additional calibration device is necessary. Like all Data Industrial products, the 600/650 may be used as a single purpose device, providing one output from a flow sensor; or combined with other pulse transmitters, flow monitors, analog transmitters or set point controls to provide complete data aquisition or process control from a single sensor. Applications The Model 600 is intended for use with any device that requires a scaled pulse; to log or display flow; or as the input to a flow based process control. Typical examples of these kinds of devices requiring a pulse signal proportional to flow are: • • • • • • • • Chemical Feed or Chemical Metering Pumps Batch Control Systems Mixing or Blending Systems Data Loggers SCADA Systems Energy Management Systems BTU Management Systems Central Irrigation Controllers Product Features 1. User Adjustable Scale – The user can select the units per pulse from a wide range, depending on pipe size, from the calibration charts supplied with the unit. The calibration is set by positioning a series of dip switches on the circuit board. 2. 3. 3.16" 80mm 2.36" 60mm .75 " 19mm 3 Types of Pulse Outputs – Every Model 600/650 is equipped with a TTL output. The user may also order either a dry contact mechanical relay closure, or an opto-isolated transistor closure. (See ordering information.) Adjustable Pulse Duration – To further increase the flexibility of the Model 600/650, the user may select the length of time that the relay is closed when sending an output pulse. The duration varies from 0.1 second to 1.5 seconds in increments of 0.2 seconds. Selection is by a 3 position dip switch on the circuit board. 5.92" 150mm 6.68" 169mm 2.64" 67mm 1.83" 46mm 4. L.E.D. Indicators – The input from the sensor and the output pulse are displayed by L.E.D.’s on the circuit board giving visual proof of operation. DTB-020-01 7-04 135mm 5.31" SW2- Output Pulse Width Selector Wiring Connection 121 mm 4.78" LED #2 Output Indicator 2.28" 58 mm SWI- Calibration Switch LED #1 - Input Indicator Specifications Operating Range: — Fluid velocity 1 to 30 feet per second. Small pipe option 1/4 to 8 feet per second. Division Range: — 1 to 4095 in unit increments Output Width: — 0.1 to 1.5 seconds in 0.2 second increments Power: — 12 - 30 VAC 45 mA max 12 - 40 VDC 30 mA max — Reverse and overvoltage protected to 40 VDC Transient Surpression: — Sensor and power inputs and TTL output designed to withstand 5000 volt 1/2 microsecond, 100 kHz ring wave. Temperature Range: — Operating Temperature -20° to +149°F, (-29° to 65°C). — Storage Temperature -40°F to 185°F (-40°C to 85°C). Conformal Coating: — All circuits are coated with a clear colorless coating meeting Milspec Mil-1-46058C, type AR, for humidity, moisture resistance and fungus resistance. Cable: — 8 conductor 22 AWG tinned copper with foil shield, 250” diameter, 80°C temperature rating. UL listed. 36” (90cm.) length with Molex connector. Enclosure - (Model 600): — Polycarbonate with tongue/groove polyurethane sealed cover. Meets NEMA 1,2,3,3R,4X,5,6,12 and 13 specifications. Outputs: TTL (All Models) — Open collector transistor internally pulled to 5 VDC in normal High State. Can be externally pulled to 20 VDC max. interface with CMOS or other Pulse Frequency inputs — Output High: 5 volts +/- 10% with approx. 50 k• source independence — Output Low: 0.35 volts max., sinking 1 mA sinking resistance 100 • Dry Contact Closure: (Model 600-15, 650-15) — SPST dry contact Reed relay contacts rated at 10 vA @ 0.5 A isolation 350 VDC (Model 600-16, 650-16) — DPST dry contact Reed relay conacts rated at 10 vA @ 0.5 A isolation 350 VDC Opto-Isolated Transistor: — Open Collector Output (Model 600-30, 650-30) VCE max. = 50 VDC VCE max. = 5 volts Isolation = 275 VDC ICEO = 10 nA (Leakage @ VCE = 10 volts) Ordering Information 600-XX — NEMA 4X housed version with 36” cable. 650-XX — Un-housed - circuit board only. 6X0-15 — Single dry contact relay and TTL output. 6X0-16 — Dual dry contact relay. 6X0-30 — Opto-Isolated transistor and TTL output. 07061 — 36” cable assembly with Molex connector. (Optional - cable with Molex is included in 600 mA-850 Molex kit is provided with 650.) Power Supplies — A-1026 120 VAC/12 VDC - plug-in type. — A-1016 120 VAC/12 VDC - barrier strip. Due to continuous research, product improvements and enhancements, Data Industrial reserves the right to change product or system specifications without notice, except to the extent an outstanding bid obligation exists. Please see our website at www.dataindustrial.com for specific contacts. Copyright © Data Industiral Corp. 2004. All rights reserved. P.O. Box 740, Mattapoisett, MA 02739-0740 Telephone: (508) 758-6390 Fax: (508) 758-4057 www.dataindustrial.com
© Copyright 2026 Paperzz