ChromaSense Light Instructions Model: TSCH Figure 3 Figure 1

Installation and Operating Instructions
C
®
ChromaSense Light Instructions
®
US
Model: TSCH
NOTE: This device is not designed to work with the TSC-250.
2. Select a location to mount the TSCH module. The TSCH
module requires a 120V outlet nearby to power the light.
ChromaSense Option:
3. Route the light cable (25’ provided) from the TSCH module to
the hole for the light. Plug the cable into the TSCH module.
Plug the other end into the light and mount the light into the
ceiling, by folding the spring clips back while inserting it into
the mounting hole.
The ChromaSense Light features a white light for general
lighting of the steam shower. The white light, neutral in color, is
equivalent to approximately a 50 watt down light. The ChromaSense module may be connected to a non-powered light switch
to operate the white light from outside the steam room.
Figure 3
The ChromaSense Light system is designed to work with the
Steamist TotalSense TSG generators and with all versions of
the TSC Spa Controls. The white light will work independently
with just a non-powered light switch but the multicolored
ChromaSense Capability can only function with the TSC spa
control.
Control Cable
Connections
Although a single light should be adequate for most home
steam showers it is possible to gang multiple lights/modules
together for additional light. Please contact Steamist for ganging
instructions.
Auxiliary
Light Switch
Power Supply
Connection
Light
Connecttion
Figure 1
4. (Optional) Connect the auxiliary light switch terminals on the
TSCH module to a non-powered light switch located outside
the steam shower. This switch must not be connected to
power and the switch must be in a separate box from any
other light switches. For this connection, use any suitable low
voltage wire 18-24 gauge (Customer suppied)(Figure 6).
5. Connect the control cable (35’ provided) to the rest of the
Total Sense system.
6. Connect the 12 volt power supply to the TSCH module and
plug when the rest of the system has been installed.
7. After everything is fully tested apply silicone (provided)
around the fixture to seal it.
Diagnostics Lights (Figure 4):
ChromaSense Installation:
1. Select a location in the ceiling for the ChromaSense light
installation and make a 3-1/2” hole for the light in this location
(Figure 2).
Figure 2
1. The Red power LED will be lit whenever the power adapter is
plugged into the wall.
2. The green LED 2 will flash when it is communicating to the
TSC Spa Control.
3. LED 3 is not used.
25' Cable
Figure 4
01/15
-1-
LED 3
POWER
1
2
8 BIT
MASTER
J7
9 BIT
SLAVE
SW1
J6
J7
LED 2
1
2
8 BIT
MASTER
9 BIT
SLAVE
LED 3
J6
SW1
LED 2
3 ½"
POWER
To TSCH module
(Figure 3)
Pub. No. 322-A
Installation and Operating Instructions
Figure 5 - Wiring Diagram
Models: TSCH
Steamist 8 Conductor Light Cable
Standard Speaker Wire
120V
Control Cable
TSCH
TSS-IN
Invisible
Speakers
.
.
.
.
.
.
.
.
..
.
.
..
.
.
.
.
.
.
..
.
.
..
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. .
.
.
.
.
.
. .
.
.
TSS-CL
Classic
Speaker
.
.
TSCH
Light
.
Auxilary
Light Switch
(Customer Supplied)
.
.
TSMU
.
Control
Cable
Standard Speaker Wire
.
.
.
.
.
.
.
.
120V
.
.
.
.
.
..
. .
.
.
.
.
.
. .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Control
Cable
.
. .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. .
.
.
.
.
.
.
.
.
.
.
.
.
TSA
.
.
.
Control Cable
.
.
.
.
.
.
.
.
.
1
2
STOP
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
MEMORY 2
.
.
MEMORY 1
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. .
.
.
.
.
.
.
.
.
. .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
120V
TSC Spa
Control
Version 3.0 or
Higher
.
.
.
.
.
.
.
.
.
Aroma
Injection Tubes
.
ESSENTIAL OIL
.
respiratory
ESSENTIAL OIL
IM
.
restore
.
.
.
TSX-220
Control
.
.
.
Wireless
Receiver
.
.
.
Control
Cable
.
.
.
.
.
. .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Control Cable
.
.
. .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Aroma
Injection Tee
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
TSG
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Shown with other Spa Options
Figure 6 - Auxilary Light Connection (Optional)
Non-powered low voltage
wires (Customer supplied)
From auxilary
Light Swtich
®
East Coast Office: 25 E. Union Ave., East Rutherford, NJ 07073 • Tel: 800-577-6478 • Fax: 201-933-0746
West Coast Office: Tel: 800-355-6478 • Fax: 661-940-1617
01/15
-2-
Pub. No. 322-A