Product Specification Sheet –Glazed Operable Wall AllVu Series 3550 Centre Tracking Operable Wall Frameless Glass Wall Project Name: [insert] Wall Location: [insert] Opening Dimensions: [insert] Overhead support Structure: [insert] Product Description: Frameless glazed operable walling as shown on the plans shall be HUFCOR Series 3550 as furnished and installed by an authorised representative of HUFCOR. Operation: Panels shall be top supported, and fitted with a one point suspension system, panels will be hinged in groups of two. The panels shall be manually moved into position and secured by the setting of a footbolt on each panel. The design of the interlocking footbolt ensures that it must be set before the next panel group can be positioned and secured. Panels shall be stored in a centre stacking configuration at either end of the opening. No floor track shall be used. Tracking: Hufcor System 5, Heavy duty centre tracking extruded aluminium system. Each panel to have a single, 4 wheeled carrier, complete with moulded polymer tyres and hardened steel bearings, the carrier is positioned centrally along the width of each panel. [weight to 120kgs per panel] Tracks to be installed from overhead structure [refer to drawings for track installation method] Panels: Panels shall be 40mm thick and shall be up to 1200mm wide[subject to wind loadings if applicable]. The top and bottom rails shall be manufactured from a one-piece extruded aluminium section and incorporate (if required) two continuous runs of non PVC thermoplastic sweep seals. The glass shall be affixed to the rails with stainless steel rods through holes in the glass to prevent slippage. Friction or adhesive fixing of the glass to the rail shall not be accepted. The glazing shall be in accordance with Australian Standard AS 1288-2006 and AS1170.2. The top rail shall incorporate coated steel fixing blocks for carrier bolts and the bottom rail shall permit fitting of concealed footbolts and locks. The whole door system shall been strength tested and comply with AS-4420-1996 Product Specification Sheet –Glazed Operable Wall AllVu Series 3550 Centre Tracking Operable Wall Frameless Glass Wall Basic Panels shall be equal in module to a maximum of 1200mm wide or as nominated. Full height access door panel shall be up to a maximum of 1060mm and fitted with Hufcor (standard) hardware. Maximum height: 12mm glass 3200mm 15mm glass 3500mm All as nominated in AS 1288-2006 [subject to design wind pressures] For heights beyond those nominated a Certificate of Compliance-Design to the Building Regulations 2006, forming part of the building Act 1993, must be provided. Glazing: The panel frames shall be factory glazed as: (Please delete unwanted option and add glass type and thickness) 12mm Toughened to AS- 2008 15mm Toughened to AS- 2008 (Please delete unwanted options) Clear: available in 12mm and 15mm thicknesses Grey: available in 12mm only Bronze: available in 12mm only Green: available in 12mm only The glazing is to be in accordance with Australian Standard AS 1288-2006 for Span / 60 as a minimum, the glass must be designed to withstand human impact and where applicable, wind loadings. The exposed aluminium shall be: (Please delete unwanted options) Powder coated to selected colour Satin natural anodised Colour anodised to selected colour Available Accessories/Options (Please delete unwanted options) Thumb turn floor lock Keyed floor lock Vertical edge trims and polybond- bulb draught seals Hufcor Group Australia – Branch Offices: QLD (07) 3718-7300; NSW (02) 9707-0700; VIC (03) 9338-7400 SA; (08) 8340-8147; WA; (08) 9455-2822 New Zealand: 0011-(64) 4586-7162 Website: www.hufcor.com.au Product Specification Sheet –Glazed Operable Wall AllVu Series 3550 Centre Tracking Operable Wall Frameless Glass Wall Jamb Starter Options (Please delete unwanted options) Leaving a 50mm gap at storage end to permit the movement of the closure panel into the storage area. Overlapping the opening. Storage area door Non sliding Pivot panel mounted to the track and floor creating a free travelling full height closure or door. Hinged Flipper panel Available Accessories/Options for Pivot or Door Panel: (Please delete unwanted options) Thumb turn floor lock Keyed floor lock Side Fix Patch c/w lever handles Vertical edge trims and polybond draught seals or clear bulb seals. Satin Stainless Steel Pull Handles (32mm dia x 300mm) or as nominated. Substitute free pivoting floor spindle with 90degree single action hydraulic floor spring Substitute free pivoting floor spindle with 180degree double action hydraulic floor spring Optional Jambs: Aluminium wall jambs for fitment to the structural wall at each end of the opening. [if required.] (Please delete unwanted options) 100mm x 45mm concealed fixed 75mm x 35mm concealed fixed “L” wall mounted angle “C” wall mounted channel Warranty: The movable glass wall shall be fully guaranteed by the manufacturer against defects in workmanship or materials for a period of 12 months from date of installation. The manufacturers guarantee shall not exceed that of the glass supplier if such supplier’s guarantee is less than that provided above Tolerances: The maximum permissible overhead structural deflection under load shall be 3mm. Floors shall be level in the path of the partitioning to a tolerance not exceeding + 3mm. The general contractor shall be responsible for rectification of floors outside this tolerance. Jambs shall be plumb, the maximum variation of opening width shall be + 5mm. Hufcor Group Australia – Branch Offices: QLD (07) 3718-7300; NSW (02) 9707-0700; VIC (03) 9338-7400 SA; (08) 8340-8147; WA; (08) 9455-2822 New Zealand: 0011-(64) 4586-7162 Website: www.hufcor.com.au
© Copyright 2026 Paperzz