08 Membrane Brochure

MEMBRANE SOLUTIONS
PURIFYING THE WATERS OF THE WORLD
EXPERIENCE !
Enaqua has been designing and fabricating MF, UF, NF and RO systems for over 20 years. Our engineering and design team
have in excess of 100 years of experience – going back to the early days of spiral membrane technology where our founder was
in charge of the US Governments proving grounds at Roswell, NM. This experience ensures that the project is completed to the
highest standards. In addition to the design and technology experience, Enaqua has substantial experience in operating RO
systems. We utilize this operating experience to design and manufacture the system with the operator in mind. We have helped
many of our friends in the industry, including assistance on a 50 MGD seawater desalination project in California.
DESIGN PHILOSOPHY !
Enaqua’s design philosophy is simple and relatively unique in the industry. Each system is individually optimized, and every
project is customized to meet the customer’s requirements as opposed to making the customer adapt to a standard design. We
build systems conservatively to minimize operational issues and ensure long term reliable performance. Robust control systems
are utilized that continually monitor and control each system. Touch screen interfaces are typically used for system operation and
control, use of variable frequency drives and energy recovery systems are utilized where applicable to minimize power usage and
operating costs.
SPIRAL UF vs. HOLLOW FIBER UF
Significant advancements have been in ultrafiltration membrane products over
the last decade. These advancements have been driven by technological benefits,
the need to reuse wastewater, and stricter regulations regarding the treatment of surface
water for use as potable water. Through this developmental stage, no clear technology, membrane
type, or configuration has emerged as a leader in the field.
WATER TO
FILTER IN
FILTERED
WATER OUT
Membranes are available in numerous configurations including hollow fiber, plate and frame, and spiral. The hollow fiber
membranes suffer from fiber breakage issues, with thousands and thousands of fibers susceptible to breakage on each and
every project. Plate & frame configurations do not have this issue, however they are not as efficient in packaging membrane area.
Both the hollow fiber and the plate & frame have the disadvantage of being proprietary in nature, with the end user locked into
the manufacturer for replacements for the life of the product. Enaqua believes that the spiral UF configuration offers the best
combination of membrane technology, simplistic design, cost effectiveness and low O&M costs.
THE ALTERNATIVE TO MBR’s
In the current state of the art wastewater treatment plant, the trend is to move away from tried and true biological processes and
move to Membrane Bio-Reactors (MBR’s). Although MBR’s are a novel and very functional process they are quite expensive
to install and operate. Enaqua has teamed with manufacturers of standard package plants and Sequencing Batch Reactors to
provide turnkey biological and tertiary treated water that may be used for reuse. The use of SBR’s plus Enaqua’s ENPURE Microor Ultra-filtration membrane systems is a cost effective and low maintenance option to MBR technology.
The Enaqua Advantage
Spiral UF Systems specifically designed for wastewater
Designed for simple operation
Non-proprietary membranes used on all projects
Skid mounted for easy installation
No membrane fibers to break or repair
Brackish and seawater desalination
Touch screen operator Interface
Energy recovery for seawater and brackish RO applications
SCADA control systems available
Designed and manufactured in the USA
Custom designed systems for each application
MEMBRANE SOLUTIONS
PURIFYING THE WATERS OF THE WORLD
Enaqua Membrane Solutions and Systems cover a broad range of applications. Below is a partial list of recent membrane solutions:
Client: Problem: Discovery Lands, Hawaii
Highly brackish feed water needed for potable and
irrigation use.
Enaqua Solution: 1.44 MGD (5,451 m3/day), Turnkey System included
AFP™ Non-Contact UV, SCADA and Energy
Recovery – Well drilling and local site installation and
coordination with consulting engineers.
Client: Problem: Ramona Municipal Water District
Municipal wastewater for class A reuse – disposal of
concentrate needed to be minimized.
Enaqua Solution: 720,000 GPD (2,726 m3/day) Enaqua Enpure UF
Membrane Solutions plus Enaqua AFP Non-Contact
UV combined with a RO Membrane concentrate
recovery system.
Client: National Park Service – US Govt.
Problem: Highly brackish well water – low power requirement.
Enaqua Solution: A unique gravity fed RO system utilizing full SCADA
control including telemetry systems to open and
close valves and other devices from water source to
membrane system. Full water storage and electrical
work including MCC’s designed and manufactured by
Enaqua.
Client: Problem: EPCOR/Primary Power, LLC
Recovery of wastewater and production of boiler feed
water.
Enaqua Solution: 86,400 GPD (327 m3/day) Utilized RO Concentrate
recovery system.
Client: Problem: Continuous Coatings
Recover water and separate spent metals from an
industrial process wastewater stream.
Enaqua Solution: 43,200 GPD (163.5 m3/day) Recover feed water
consisting of process rinse water from a metal
fabrication factory – system design included Enpure
UF and RO membranes.
Client: Problem: CDM/Frito Lay/Pepsi
Feed water source is microfiltered effluent from a
potato chip factory to be reused.
Enaqua Solution: 864,000 GPD (3,2730 m3/day) System includes UV
disinfection and high recovery RO system.
Client: Problem:
Sudarshan Chemical Industries
Lead Acetate was being used in a manufacturing
process and diluted – costly purified water was being
discharged.
Enaqua Solution: 15,000 GPD (57 m3/day) Membrane system to recover
the expensive lead acetate and reconentrate it from
.5% solution to 6%. By product recovery of DI water
stream.
Client: Problem: Hualalai Development
Resort needed expansion of system by 1 MGD ( 3,784
m3/day)
Enaqua Solution: Unique gravity fed RO System including turnkey
filtration and controls.
Client: Problem: Kukio Resort
Hawaiian resort required a new system capable of
expanding to 2 MGD (7,568 m3/day) – source of water
was far away.
Enaqua Solution: Unique gravity fed system including Enpure Filtration,
RO and SCADA.
Client: Westin Hotels Maui
Problem: Hawaiian resort required seawater from a deep well.
Enaqua Solution: 288,000 GPD (1,090 m3/day) Seawater desalination
system including AFP Non-Contact UV System,
filtration- using full SCADA control and energy
recovery.
Client: Problem: El Cid Hotels
Brackish water with high levels of H2S04, and
fluctuation salinity of 2,000-15,000 ppm.
Enaqua Solution: 144,800 GPD (545 m3/day) Membrane System
includes degasification and AFP Non-Contact UV
disinfection.
Spiral wound UF Membrane Solutions by Enaqua offer a number of advantages over rival technologies...
Enaqua ENPURE
Plate & Frame
Hollow Fiber
No Fibers to break
4
4
6
Can be made with a variety of membranes and spacer materials
4
4
6
Multiple suppliers – eliminating sole source issues
4
6
6
High Velocity flow for fouling reduction
4
6
6
Over 30 years of installed expertise
4
6
6
Simple – no blowers and vacuum pumps
4
6
6
PURIFYING THE WATERS OF THE WORLD
2446 CADES WAY
VISTA CA 92081 USA
T: +1.760.599.2644
F: +1.760.599.2642
E: [email protected]
www.enaqua.com
©1985-2009 ENAQUA. All rights reserved. All trademarks acknowledged as belonging to their owners, AFP, AFP840, Activated
Flouropolymer, Enaqua, XUV, Enpure, Enlight, the AFP840 Logo, Enaqua Logo and Enpure Logos and marks are Trademarks of Enaqua.