IAG - Industrie Automatisierungsgesellschaft m.b.H Test Cell Technology consistently advancing More than 30 years of Austrian innovation Company History IAG Industrie Automatisierungs Gesellschaft mbH was founded in 1986. From the very beginning, IAG has been active in the manufacturing of complex special-purpose machinery. IAG develops fully automatic machinery and systems for the manufacturing of brake pads and has become a global market leader in this industry. Our competent and experienced team, currently comprising a staff of approximately 100, is able to meet the most exacting customer requirements by implementing recent technologies to achieve innovative, customized solutions. 2 Experience gathered over many years in general engineering as well as in electrical engineering and control technology enable us at IAG to develop and realize highly complex solutions. IAG Test Cell Technology offers an extensive range of products for exhaust gas measurement in engine development as well as for the associated test cell environment. The high quality of our products, our flexibility in developing custom solutions and our exceptional service make us a dependable partner. IAG - Industrie Automatisierungsgesellschaft m.b.H · Industriestraße 2 · 2722 Weikersdorf · T +43 2622 21734/77 · F +43 2622 21734/85 · E [email protected] History of IAG Test Cell Technology 2002 Establishment of the Company “Artech” 2003 Development of the First VFC Pre-Filter with Integrated Pressure Regulator 2006 Integration of “Artech” into IAG Development of the VFS Pre-Filter with Multiple Gas Inlets 2007 First FTIR-Analyzing Systems are Sold 2011 Development of the FTIR-Analyzing Systems FAS05 Versa The First Combined Measurement System Delivered (Synthesis Gas Test Bench) 2014 Over 1000 Sampling Systems (PNS) are Manufactured 2015 More than 70 FTIR-Analyzing Systems are in Use 2016 Launch of FTIR-Analyzing Systems versa06 Systems and components of IAG Industrie Automatisierungs Gesellschaft are used worldwide. Industriestraße 2 · 2722 Weikersdorf · T +43 2622 21734/77 · F +43 2622 21734/85 · E [email protected] · IAG - Industrie Automatisierungsgesellschaft m.b.H 3 Our key principle is to provide you with the best customer service. IAG Service Philosophy Custom Solutions Optimum customer care is our overriding principle. This means responding to customer requirements on an individual basis and developing tailored solutions in every case. We are constantly developing customized solutions for specific usage requirements. From tailor-made modules to be integrated into existing systems, to the full development of devices and equipment exclusively branded for the customer. We have a long tradition of building engineering solutions in the areas of hardware and software. The range extends from a convenient, all-inclusive service contract that covers all maintenance and repair costs, to self-maintenance carried out by the user. This can be accomplished through the simple replacement of component groups or complete maintenance by the customer. Stefan Handler Sales and Customer Service Manager Ing. Rainer Pokorny Technical Manager Using IAG system construction kits with many common parts, only a minimal number of wearing parts are required to be able to constantly guarantee usability. We always keep a very extensive stock of replacement parts to ensure the shortest possible amount of downtime in every case. 4 IAG - Industrie Automatisierungsgesellschaft m.b.H · Industriestraße 2 · 2722 Weikersdorf · T +43 2622 21734/77 · F +43 2622 21734/85 · E [email protected] Product Overview versa06 P.6 VFS P.14 versa06 dual P.8 VFC P. 15 VFE P.19 FLS P.24 versa06 plus P.10 VFD P.16 VFH P.20 MSJ P.25 Analyzing Systems NMS P.12 LFD P.17 ADR02 P.18 LFS P.21 FILTER P.22 MGK P.26 HSV P.27 Pre-Filters / Pressure Regulators Pre-Filters Gas Feed TRE01 P.28 TRE05 P.28 TRE08 P.29 MTS P.30 Test Cell Equipment Subject to technical alterations, errors and misprints excepted. Industriestraße 2 · 2722 Weikersdorf · T +43 2622 21734/77 · F +43 2622 21734/85 · E [email protected] · IAG - Industrie Automatisierungsgesellschaft m.b.H 5 versa06 FTIR Analyzing system updates being automatically passed on to users. Calibrations are permanently stored on the device and checked once a year. Accuracy and Response: Analyzing Systems Simple Touchscreen Operation NH3 180 160 140 120 100 80 60 40 20 0 0 1000 500 NH3 IAG ppm 1500 2000 NH3 Competitor ppm N2O 25 Easy Charging for Automatic LN2 Refill 20 15 10 Easy Charging for Automatic LN2 Refill inside Based on our long lasting experience with the FTIR technology the IAG versa06 is a reliable and servicefriendly measuring system with high precision and stability. User friendliness, high dynamic, careful gas flow, easy maintenance and the flexibility of the modular IAG design are important advantages of the IAG versa06 exhaust analyzing systems. IAG versa06 stands for high availability and low operating costs, optimizing your use of resources. Based on our years of experience in treating sample gas, one of the greatest strengths is its ability to analyze even gas components that are hard to detect. Calibration: Every available analyzis method and calibration type is included in this model. The library is constantly being extended, with all 6 5 0 0 500 N2O IAG ppm 1000 1500 2000 2500 3000 N2O Competitor ppm Fast response in NH 3 measurement. Clear N2O signal down to far below 1 ppm. This data was recorded in a comparative measurement with a reference system. Both samples were taken from one sample point with a flow of 7l/Min. Careful gas flow within the device plays a central role in the detection of components that are hard to measure. The benefits of the IAG FTIR technology is based on optimized gas flow without any cold spots as well as closed loop control for pressure and temperature in the gas cell are the base for the precision of the system. As an option the flow can be adjusted and controlled. For high dynamic measurements a high speed version with a measuring rate of 5Hz is available. Communication: The options for communication with the test bench environment range from AK serial, TCP or remote desktop connection to straightforward bit parallel control. Adaptation to meet customers’ needs and providing custom solutions is our standard. IAG - Industrie Automatisierungsgesellschaft m.b.H · Industriestraße 2 · 2722 Weikersdorf · T +43 2622 21734/77 · F +43 2622 21734/85 · E [email protected] versa06 FTIR Analyzing system Sampling: The IAG versa06 can be combined with any IAG sampling modules. The options here extend from a simple heated line sucking the sample, to extensive multiple extraction systems with pressure regulators, switching units and high temperature extraction lines. All sampling modules are remotely controlled by the measurement device itself and are displayed at the device display panel. Every parameter such as temperature and switching status for the entire system can be configured and operated from a central location. Advantages + Precise Closed Loop Gas Cell Pressure Control + Short Gas Lines + High Dynamic + Automatic LN2 Refill + Easy Operation and Maintenance + Precise Measurement + Flexible Setup + Low Operating Costs + Fixed Calibration + Automatic Leak Test Analyzing Systems Safety: Reliable use of the FTIR technology requires new overall concepts of FTIR analyzing systems. The IAG versa06 includes a safety system which protects the device from damage in case of an interruption of the voltage or purge air supplies by full automatic purging. Options • Integration of Additional Analyzers e.g. for HC or O2 Measurement Service: We take care of our customers with individually tailored maintenance solutions. Our offering ranges from full service contracts covering all running costs to servicing by the user who, thanks to the IAG modular system, can carry out all maintenance work himself quickly and easily. Capable care and optimum support are ‘givens’ for our customers. • Adjustable Sample Gas Flow • High-Speed Version with 5Hz Sampling • Automatic Refill of Liquid Nitrogen • Integrated Purge Gas Generator • Cabinet Air-Conditioning for High Ambient Temperatures • Gas Removal with Condensate Reservoir Detectable Components Overview: • Integration of Sampling Systems • Various Pump Performance Available Hydrogen SulfideH2S AcetyleneC2H2 Isocyanic AcidHNCO Acetaldehyde C2H40 Methane CH4 Acrolein C3H40 Methanol CH40 AmmoniaNH3 m-Xylene C8H10 1,3 Butadien C4H6 Nitric OxideNO Benzene C6H6 Nitric OxidesNOx Carbon DioxideCO2 Nitrogen DioxideNO2 Carbon MonoxideCO Nitrous Oxide N20 Diesel- o-Xylene C8H10 Dodecane C12H26 Propanal C3H60 Ethane C2H6 PropaneC3H8 Ethanol C2H60 Propylene C3H6 Ethyl Benzene C8H10 Sulfur DioxideSO2 Ethylene C2H4 TolueneC7H8 Formaldehyde CH20 Total HydrocarbonsTHC Formic Acid CH202 Water H20 Hydrogen CyanideHCN • Optional Bag Measurement • Inert Coating • EPA 1065 Test Procedures • Special Calibration with 2 % Linearity • Zirconia Oxygen Measurement • Lambda Sensor Technical Data Dimensions: 900 x 600 x 1260 mm Sampling Rate: 1 Hz / 5 Hz Sample Flow: 8-10 l/Min or 12-15 l/Min Sample Flow 5Hz: 20-25 l/Min Sample Flow Adjustable: 3-10 l/Min or 4-15l/Min Sample Flow 5Hz Adjustable: 5-25 l/Min Purge Gas: Nitrogen 5.0 or Purified Air Detector:MCT Gas Cell: 5.11 m Path Length, 200 ml Spectral Resolution: 0,5 cm-1 Gas Cell Temperature: 190 °C Compressed Air Supply: 5 bar, Dry and Oil-Free Power Supply: 400 V / 16 A CEE Industriestraße 2 · 2722 Weikersdorf · T +43 2622 21734/77 · F +43 2622 21734/85 · E [email protected] · IAG - Industrie Automatisierungsgesellschaft m.b.H 7 versa06 dual FTIR Analyzing system Calibration: Every available analyzis method and calibration type is included in this model. The library is constantly being extended, with all updates being automatically passed on to users. Calibrations are permanently stored on the device and checked once a year. Analyzing Systems Simple Touchscreen Operation Accuracy and Response: NH3 180 160 140 120 100 80 60 40 20 0 0 1000 500 NH3 IAG ppm 1500 2000 NH3 Competitor ppm N2O 25 20 15 Easy Charging for Automatic LN2 Refill inside 10 5 0 The versa06 dual FTIR analyzing Systems offer two independent FTIR-Analyzers for simultaneous measurement at two independent sampling points. The evaluation of the two measuring circuits with the same operating surface guarantees for optimum user friendliness. The consequent 2-line gas management ensures high dynamic in both measuring circuits. Easy maintenance and the flexibility of the modular IAG design are further advantages of the IAG versa06 dual FTIR analyzing Systems. IAG versa06 dual stands for high availability and low operating costs, optimizing your use of resources. Based on our years of experience in treating sample gas, one of the greatest strengths is its ability to analyze even gas components that are hard to detect. 8 0 500 N2O IAG ppm 1000 1500 2000 2500 3000 N2O Competitor ppm Fast response in NH 3 measurement. Clear N2O signal down to far below 1 ppm. This data was recorded in a comparative measurement with a reference system. Both samples were taken from one sample point with a flow of 7l/Min. Careful gas flow within the device plays a central role in the detection of components that are hard to measure. The benefits of the IAG FTIR technology is based on optimized gas flow without any cold spots as well as closed loop control for pressure and temperature in the gas cell are the base for the precision of the system. As an option the flow can be adjusted and controlled. For high dynamic measurements a high speed version with a measuring rate of 5Hz is available. Communication: The options for communication with the test bench environment range from AK serial, TCP or remote desktop connection to straight IAG - Industrie Automatisierungsgesellschaft m.b.H · Industriestraße 2 · 2722 Weikersdorf · T +43 2622 21734/77 · F +43 2622 21734/85 · E [email protected] versa06 dual FTIR Analyzing system Advantages + Simultaneous Measurement at 2 Different Sampling Points + Precise Closed Loop Gas Cell Pressure Control + Short Gas Lines + High Dynamic + Automatic LN2 Refill + Easy Operation and Maintenance + Precise Measurement + Flexible Setup + Low Operating Costs + Fixed Calibration + Automatic Leak Test Sampling: The IAG versa06 dual can be combined with any IAG sampling modules. The options here extend from a simple heated line sucking the sample, to extensive multiple extraction systems with pressure regulators, switching units and high temperature extraction lines. All sampling modules are remotely controlled by the measurement device itself and are displayed at the device display panel. Every parameter such as temperature and switching status for the entire system can be configured and operated from a central location. Service: We take care of our customers with individually tailored maintenance solutions. Our offering ranges from full service contracts covering all running costs to servicing by the user who, thanks to the IAG modular system, can carry out all maintenance work himself quickly and easily. Capable care and optimum support are ‘givens’ for our customers. Options • • • • Detectable Components Overview: Hydrogen SulfideH2S AcetyleneC2H2 Isocyanic AcidHNCO Acetaldehyde C2H40 Methane CH4 Acrolein C3H40 Methanol CH40 AmmoniaNH3 m-Xylene C8H10 1,3 Butadien C4H6 Nitric OxideNO Benzene C6H6 Nitric OxidesNOx Carbon DioxideCO2 Nitrogen DioxideNO2 Carbon MonoxideCO Nitrous Oxide N20 Diesel– o-Xylene C8H10 Dodecane C12H26 Propanal C3H60 Ethane C2H6 PropaneC3H8 Ethanol C2H60 Propylene C3H6 Ethyl Benzene C8H10 Sulfur DioxideSO2 Ethylene C2H4 TolueneC7H8 Formaldehyde CH20 Total HydrocarbonsTHC Formic Acid CH202 Water H20 Hydrogen CyanideHCN Analyzing Systems forward bit parallel control. Adaptation to meet customers’ needs and providing custom solutions is our standard. Integration of Additional Analyzers e.g. for HC or O2 Measurement Adjustable Sample Gas Flow High-Speed Version with 5Hz Sampling Automatic Refill of Liquid Nitrogen • Integrated Purge Gas Generator • Cabinet Air-Conditioning for High Ambient Temperatures • Gas Removal with Condensate Reservoir • Integration of Sampling Systems • Various Pump Performance Available • Optional Bag Measurement • Inert Coating • EPA 1065 Test Procedures • Special Calibration with 2 % Linearity • Zirconia Oxygen Measurement • Lambda Sensor Technical Data Dimensions: 900 x 600 x 1700 mm Sampling Rate: 1 Hz / 5 Hz Sample Flow: 2 x 8-10 l/Min or 2 x 12-15 l/Min Sample Flow 5Hz: 2 x 20-25 l/Min Sample Flow Adjustable: 2 x 3-10 l/Min or 2 x 4-15l/Min Sample Flow 5Hz Adjustable: 2 x 5-25 l/Min Purge Gas: Nitrogen 5.0 or Purified Air Detector: 2 x MCT Gas Cell: 2 x 5.11 m Path Length, 200 ml Spectral Resolution: 0,5 cm-1 Gas Cell Temperature: 190 °C Compressed Air Supply: 5 bar, Dry and Oil-Free Power Supply: 400 V / 16 A CEE Industriestraße 2 · 2722 Weikersdorf · T +43 2622 21734/77 · F +43 2622 21734/85 · E [email protected] · IAG - Industrie Automatisierungsgesellschaft m.b.H 9 versa06 plus Exhaust gas Analyzing system directly in the test cell, the FTIR can only show its true strength if the overall design of the device has been developed accordingly. Analyzing Systems Simple Touchscreen Operation This has required developments ranging from a climate control unit for high and fluctuating ambient temperatures to safety switches that safeguard the device from damage in the event of an interruption to the voltage or purge air supplies. Analyzers: Our aim is to provide the ideal solution for any application and to allow every user to make use of tried and trusted measurement technology. We therefore support the option of integrating all analyzers available on the market and of combining these to achieve a complete customized system. Gas Feed: Precise gas flow within the device plays a central role in the detection of components that are hard to measure. This system is based on an optimized design, providing for the shortest possible gas flows as well as precise pressure levels and temperature conditioning. Users have the option of disconnecting analyzers individually from the gas flow without affecting the system dynamics, or to make measurements only using the FTIR with a short sampling line via a separate sample gas inlet. The use of a heated sample gas pump renders the system insensitive, within a wide range, to varying pressures at the sampling point. Easy Charging for Automatic LN2 Refill inside The versa06 plus measuring system offers a wide variety of configuration options, “plus” stands for the combination of FTIR and conventional measuring technology. The IAG versa06 plus combines in a single system the wide range of options offered by FTIR technology with the reliability of standard measurement technology. The outstanding features of the IAG versa06 plus include ease of use, large dynamic measurement range, precise gas feed, maintenance friendliness and the flexibility offered by the IAG module system. Calibration: Dependable use of FTIR technology also means specific considerations as to how a measurement device is designed. As with any measurement device that needs to be used flexibly and if necessary, 10 Communication: The options for communicating with the test cell environment range from AK serial, TCP or remote desktop connection to straightforward bit parallel control. The measurement reading can be outputted via the relevant interface, or via fully customisable analogue outputs where storage of measurement readings can be started or triggered independently by the measurement process. Adaptation to meet customers’ needs and providing custom solutions is the norm for us. Operation: The system is operated either directly using the 17” TFT touch screen or via remote desktop. The user interface of the IAG versa06 plus is structured clearly and flexibly and offers all the features users have come to expect from advanced control interfaces. Sampling: The IAG versa06 plus can of course be combined with any IAG sampling module. The options here extend from a simple heated line, serving as a suction feed for the measurement device, to extensive multiple extraction systems with pressure regulators, switching units and high temperature extraction lines. All sampling modules are remotely controlled from the measurement device itself and are also displayed in the device display panel. This means that every parameter such as temperature and switching status for the entire system can be configured and operated from a central location. IAG - Industrie Automatisierungsgesellschaft m.b.H · Industriestraße 2 · 2722 Weikersdorf · T +43 2622 21734/77 · F +43 2622 21734/85 · E [email protected] versa06 plus Exhaust gas Analyzing system Advantages + Customized Analyzing Modules + Portable Use + Precise Measurement + Flexible Setup + Low Operating Costs + Easy Maintenance Detectable Components Overview: Hydrogen SulfideH2S AcetyleneC2H2 Isocyanic AcidHNCO Acetaldehyde C2H40 Methane CH4 Acrolein C3H40 Methanol CH40 AmmoniaNH3 m-Xylene C8H10 1,3 Butadien C4H6 Nitric OxideNO Benzene C6H6 Nitric OxidesNOx Carbon DioxideCO2 Nitrogen DioxideNO2 Carbon MonoxideCO Nitrous Oxide N20 Diesel– o-Xylene C8H10 Dodecane C12H26 Propanal C3H60 Ethane C2H6 PropaneC3H8 Ethanol C2H60 Propylene C3H6 Ethyl Benzene C8H10 Sulfur DioxideSO2 Ethylene C2H4 TolueneC7H8 Formaldehyde CH20 Total HydrocarbonsTHC Formic Acid CH202 Water H20 Hydrogen CyanideHCN Analyzing Systems Service: We take care of our customers with individually tailored maintenance solutions. Our offering ranges from full service contracts covering all running costs to servicing by the user who, thanks to the IAG modular system, can carry out all maintenance work himself quickly and easily. Capable care and optimum support are ‘givens’ for our customers. + Automatic Leak Test Options • Integration of a Wide Variety of Analyzers • Direct Input Port for FTIR Measurement • Automatic Refill of Liquid Nitrogen • Integrated Purge Gas Generator • Cabinet Air-Conditioning for High Ambient Temperatures • Gas Removal with Condensate Reservoir • Integration of Sampling Systems • Automated Linearity Check Technical Data Dimensions: 900 x 600 x 1700 mm Purge Gas: Nitrogen 5.0 or Treated Compressed Air Analyzers:FTIR, NDIR, PMA, FID, CLD, TDLS etc. Compressed Air Supply: 5 bar, Dry and Oil-Free Power Supply: 400 V / 16 A CEE Industriestraße 2 · 2722 Weikersdorf · T +43 2622 21734/77 · F +43 2622 21734/85 · E [email protected] · IAG - Industrie Automatisierungsgesellschaft m.b.H 11 NMS NH3 Analyzing system Service: Another important thing to mention is the maintenance friendliness of our products. Annual maintenance can be easily done by the user and wear parts are available for very reasonable prices. Analyzing Systems Advantages + High Accuracy + Easy Setup + Low Maintenance + Compact Design + Simple Operation + IAG Filter Chamber Options Simple Touchscreen Operation • SilcoTek Surface Treatment • Gas Connections According Customers Specs Technical Data The IAG NMS measuring system is a 191 °C heated extractive diode laser ammonia detection system. This very compact and light system can be used in a wide variety of applications. Two sample gas inlets, two analogue output instrument, a built-in gas inlet pressure regulator, a heated sample gas filter, an integrated purge function, a span gas connection and any kind of communication option you might eventually like are basic technical features. Operation: Setup and operation are kept as simple as possible without sparing an operation software with all functions the advanced user would expect, including alarm parameterisation, calibration as well as open communication settings. The operation takes place via touchscreen directly at the device or via communication interfaces such as AK, RS232, Modbus or Profibus. Reponse Time: Analyzing components like NH3, which are very difficult to detect, require measuring systems that provide optimal response times. IAG has been developing heated pre-filters since 1998 and has worked ever since to create sampling modules and measuring systems with minimum internal volume, optimized gas flow, uniform heating and special surface treatment. Therefore, this system has the ability of realizing very short response times. 12 Dimensions: 530 x 350 x 340 mm Weight: 20 kg Sample Gas Connections: Swagelok 6 mm Heated Line Connections: 2 x Binder 693 Purge Gas Connection: Swagelok 6 mm Adjustable Sample Flow: 10 l/Min Filter Cartridge: 70 cm2 PTFE Bond Glass Laser Path Length: 400 mm Measuring Range: 0-2000 ppm Sampling Rate: 1 Hz Detection Limit: 0,8 ppm Accuracy: 2 % of the measured value Drift: 1 % p. 8 h, 2 % p. week Repeatability: 0,5 % Inlet Pressure: 0-3 bar rel. Power Supply: 115 VAC 60 Hz / 230 VAC 50 Hz IAG - Industrie Automatisierungsgesellschaft m.b.H · Industriestraße 2 · 2722 Weikersdorf · T +43 2622 21734/77 · F +43 2622 21734/85 · E [email protected] Ing. Gert Kain, MBA Division Manager ”You and we are working today. Together we are planning for tomorrow“ Focusing on Exhaust Analyzis The successful use of an exhaust analyzing system consists of many parameters, including precise and secure measurements, easy handling and fast response time in both measurements and after sales service. We supply all components as one single source and adapt solutions to your individual demands. The further development of the units is based on the change of your requirements. 13 VFS Sample filter Advantages + Extremely Compact + 1 to 6 Sample Gas Inlets + Up to 6 Bar Inlet Pressure + Integrated Pressure Regulator + Filter Flushing with Purge Air Outlet + Calibration Gas Feed + Control of 6 Heated Lines + Backflush Function + IAG Filter Chamber Options Pre-Filters / Pressure Controllers • • • • • • • • The VFS family with 1 until 24 sample gas inlets are the allrounders in pre-filter system. The VFS is an extremely compact, autonomous multi sample filter for flexible construction of a wide range of test set-ups. Connection to the VFS is simplified by a control unit that is integrated into the device and carries out all internal control and regulation tasks as well as communication with the test cell environment. For this reason the VFS is ideal as a replacement for older, maintenanceheavy pre-filter modules. Thanks to its versatility, it can be added to the test cell with limited modification work. - An investment that quickly pays for itself. The VFS has extremely uniform heating and an optimized gas feed that guarantees the greatest precision with measurement results. The VFS is fitted with an NC pressure regulator for max. 50 mbar outlet pressure with an inlet pressure of up to 6 bar. Furthermore the device has a backflushable filter chamber with an inbuilt purge air outlet plus a test gas inlet. All inbound sample gas lines can be separately backwashed. Control of 1 Sample Gas Pump Control of Heated/Cooled Lines Pt100 Heat Regulator Heating Control via Modbus TCP Bit Parallel Control AK Control AK Control via IAG AK Converter SilcoTek Surface Treatment Technical Data 1/2/4 Inlet Dimensions: 235 x 380 / 405 / 470 x160 mm 6E Dimensions: 245 x 535 x 160 mm 8E or 24E Dimensions: On Request Sample Gas Connections: Swagelok 8 mm Heated Line Connections: 693 6+Pe Connectors Standard Pin Assignment: 1-L, 2-TC+, 5-TC-, 6-N Communication: Bit Parallel; Modbus TCP; AK; or via System Control Panel Compressed Air Connection: 6 mm Push In/Dry and Oil-Free Compressed Air Supply: 5-6 bar Power Supply: 400 V / 3,7 kW 3 m / CEE 16 A Parameterisation is very simple to carry out via an SCP (system control panel). The SCP autonomously recognizes which device it is connected to and enables every device parameter to be set via an extremely clear, self-explanatory display on a 5.7” touch screen. The SCP is also available as a simple software tool. This means that the VFS can be connected directly to an internal network and controlled or configured from any PC. Control can optionally be bit parallel or via Modbus TCP. If an VFS is connected to an IAG measuring unit, configuration and monitoring can be carried out via the measuring unit display. 14 IAG - Industrie Automatisierungsgesellschaft m.b.H · Industriestraße 2 · 2722 Weikersdorf · T +43 2622 21734/77 · F +43 2622 21734/85 · E [email protected] VFC Sample filter Advantages + Up to 6 Bar Inlet Pressure + Backflushable + Easy to Use + Robust Piston Type Regulator + Sensitive Pressure Regulation + Long Maintenance Intervals + Easy Maintenance Options Pre-Filters / Pressure Controllers • Gas Connections according Customer Specs • Heated Line Controller • SilcoTek Surface Treatment Technical Data Dimensions: 200x210x110 mm The VFC is a universally applicable, self-supporting prefilter with an integrated pressure regulator and heat control for a heated line. Sample Gas Connections: Swagelok 8mm The VFC is a self-supporting filter/pressure regulator unit that can be quickly and easily integrated into a test set-up. If an additional filter element is required or the exhaust gas pressure is too great, the VFC is the ideal device for fast connection because of its great ease of use and the option of an additional heated line for added supply. The VFC can be supplied with an alarm output for temperature monitoring on the control centre. Inlet Temperature: max. 200 °C The backflushable ‘Normally Open’ pressure regulator reduces inlet pressures of up to 6 bar to an outlet pressure of max. 250 mbar. Naturally any IAG filter cartridge can be fitted to the VFC. Sample Inlet Pressure: max. 6 bar Output Pressure: max. 250 mbar Filter Element: A=70 cm2, Backwashable Heated Line Connection: 693 6+Pe Connector Standard Pin Assignment: 1-L,2-TC+,5-TC-,6-N Alarm Output: 711 Flange Socket Connector Pin Assignment: 1 - Internal Heating (NO) 2 - Heating Line (NO) 3 - COM Power Supply: 230V/2,3kW, 1,5m/Schuko All IAG devices can be supplied with pin assignment, gas connectors and temperature sensor type according to customer requirements. Industriestraße 2 · 2722 Weikersdorf · T +43 2622 21734/77 · F +43 2622 21734/85 · E [email protected] · IAG - Industrie Automatisierungsgesellschaft m.b.H 15 VFD Sample filter Advantages + Up to 6 Bar Inlet Pressure + Backflushable + Robust Piston-Type Regulator + Sensitive Pressure Rregulation + Long Maintenance Intervals + Easy Maintenance Options • Gas Connections according Customer Specs • Pt100 Temperature Sensor • SilcoTek Surface Treatment Pre-Filters / Pressure Controllers Technical Data Dimensions: 170 x 150 x 115 mm Sample Gas Connections: Swagelok 8 mm The VFD is a compact pre-filter including integrated pressure regulator but without built-in heat control. The VFD can be operated using any common heat controller, or it can be integrated in an IAG measuring unit. The VFD is a compact filter pressure regulator, offering an alternative to an LFD line filter with pressure regulator. Lacking a heat control of its own, it is particularly suitable for integration in existing systems, with parameterization and monitoring being performed via the control system. Sample Inlet Pressure: max. 6 bar Output Pressure: max. 250 mbar Inlet Temperature: max. 200 °C Filter Element: A=70 cm2, Backwashable Power Supply: 230V / 125 W 693 6+Pe / 600 mm Standard Pin Assignment: 1-L, 2-TC+, 5-TC-, 6-N The backflushable NO pressure regulator reduces inlet pressures of up to 6 bar to an outlet pressure of max. 250 mbar. Naturally any IAG filter cartridge can be fitted to the VFD. All IAG devices can be supplied with pin assignment, gas connectors and temperature sensor type according to customer requirements. Pressure Characteristics: 16 IAG - Industrie Automatisierungsgesellschaft m.b.H · Industriestraße 2 · 2722 Weikersdorf · T +43 2622 21734/77 · F +43 2622 21734/85 · E [email protected] LFD Line filter Advantages + Easy Filter Changing + Integrated Pressure Regulator + Backflushable + Robust + Easy Assembly + IAG Filter Chamber Options The LFD is a compact, backflushable line filter with an integrated pressure regulator. Because the heated line fitting is decoupled from the housing, the filter can be changed without closing off the heating lines. The LFD is a compact line filter with a filter fitting that is decoupled from the housing and a backflushable exhaust gas pressure regulator. It can optionally be supplied as an NO pressure regulator, reducing inlet pressures of up to 6 bar to an outlet pressure of max. 250 mbar; or as an NC pressure regulator that remains closed until a vacuum of -70 mbar relative pressure is applied on the sample gas outlet. During measurement the vacuum controller adjusts inlet pressures of up to 6 bar to max. 50 mbar on the outlet. The LFD can be coupled to an extremely compact sampling unit using an HKL (heated/ cooled line), enabling samples to be taken in a range of 50-650°C and 0-6 bar. With all IAG pre-filters, great value is placed on the highest measuring accuracy and quality. This means lasting, complete gas-tightness and compact, careful construction. Gas Connections according Customer Specs NO or NC Pressure Regulator Pt100 Temperature Sensor SilcoTek Surface Treatment Pre-Filters / Pressure Controllers • • • • Technical Data Dimensions: 200 x 120 x 110 mm Sample Gas Connections: Swagelok 8 mm Sample Inlet Pressure: max. 6 bar NO Output Pressure: max. 250 mbar NC Output Pressure: max. 50 mbar Inlet Temperature: max. 200 °C Filter Element: A=70 cm2, Backwashable Power Supply: 230 V / 200 W 693 6+Pe / 600 mm Standard Pin Assignment: 1-L, 2-TC+, 5-TC-, 6-N The filter chamber has a minimum dead volume and an extremely uniform heating system with a short warm-up time, and can accept all IAG filter elements. Heat can be regulated using any current temperature regulator. As with every IAG device, the pin assignment and type of temperature sensor can be supplied according to the customer’s wishes. Pressure Characteristics: Industriestraße 2 · 2722 Weikersdorf · T +43 2622 21734/77 · F +43 2622 21734/85 · E [email protected] · IAG - Industrie Automatisierungsgesellschaft m.b.H 17 ADR02 Exhaust gas pressure Regulator Pre-Filters / Pressure Controllers Without Cover The ADR02 is a compact, extremely robust exhaust gas pressure regulator, for use wherever accurate pressure regulation and durability are required. The ADR02 is a versatile pressure regulator that can be customized to your requirements. The scope of application extends from an unheated device with no housing (e.g. for EGR measurements) to a continuously heated, fully enclosed module for e.g. pre-cat measurements with particle load. The ADR02 can optionally be supplied as an NO pressure regulator, reducing inlet pressures of up to 6 bar to an outlet pressure of max. 250 mbar; or as an NC pressure regulator that remains closed to max. 3 bar inlet pressure until a vacuum of -70 mbar relative pressure is applied on the sample gas outlet (e.g. when the measuring device begins to pull). During measurement the vacuum controller adjusts inlet pressures of up to 6 bar to max. 50 mbar on the outlet. The conversion process from overpressure to vacuum controller and back can be carried out by the user in just a few minutes. External heating control can be carried out using any current temperature regulator. All IAG devices can be fitted with pin assignment, gas connectors and temperature sensor type according to customer requirements. And finally, fast availability and attractive prices for replacement parts make a valuable contribution to the quality and efficiency of your test cell operation. Advantages + Up to 6 bar Inlet Pressure + Optional NO or NC Pressure Regulator + Sensitive Pressure Regulation + Long Maintenance Intervals + Easy Maintenance + Robust Construction + Compact Options • • • • • • NO or NC versions Gas Connections according Customer Specs Heated Version Pt100 Temperature Sensor Powder-Coated Housing SilcoTek Surface Treatment Technical Data Dimensions without Housing: 92 x 92 x 80 mm Dimensions with Housing: 150 x 160 x 104 mm Sample Gas Connections: Swagelok 8 mm 18 Sample Inlet Pressure: max. 6 bar NO Output Pressure: max. 250 mbar NC Output Pressure: max. 50 mbar Inlet Temperature: max. 200 °C Power Supply: 230 V / 125 W 693 6+Pe / 600 mm Standard Pin Assignment: 1-L, 2-TC+, 5-TC-, 6-N IAG - Industrie Automatisierungsgesellschaft m.b.H · Industriestraße 2 · 2722 Weikersdorf · T +43 2622 21734/77 · F +43 2622 21734/85 · E [email protected] VFE Sample filter Advantages + Maintenance Free + Versatile + Robust + Compact + Low Price + IAG Filter Chamber Options • Gas Connections according Customers Specs • Pt100 Temperature Sensor • SilcoTek Surface Treatment Technical Data The VFE is a low-cost pre-filter with all the benefits of IAG filter technology. Dimensions: 150 x 145 x 105 mm Sample Gas Connections: Swagelok 8 mm The VFE is a compact, heated pre-filter offering the ultimate in measurement accuracy and user-friendliness. This means lasting, complete gas-tightness, careful gas flow and compact, careful construction. Filter Element: A=70 cm2, Backwashable Power Supply: 230 V / 125 W 693 6+Pe / 600 mm Standard Pin Assignment: 1-L, 2-TC+, 5-TC-, 6-N Pre-Filters The filter chamber has a minimum dead volume and extremely uniform heating with a fast heating-up time, and can accept any IAG filter element. The forward-facing filter fitting seal makes it quick and easy to replace filter elements. Heat can be regulated using any current temperature regulator. As with every IAG device, the pin assignment and type of temperature sensor can be supplied according to the customer’s wishes. Industriestraße 2 · 2722 Weikersdorf · T +43 2622 21734/77 · F +43 2622 21734/85 · E [email protected] · IAG - Industrie Automatisierungsgesellschaft m.b.H 19 VFH Pre-filter heated line Advantages + Maintenance-Free + IAG Filter Chamber + Integrated Heat Control + Durable + Low Price Options • • • • Alarm Output Gas Connections according Customers Specs Pt100 Temperature Sensor SilcoTek Surface Treatment Technical Data Dimensions: 225 x 170 x 115 mm Sample Gas Connections: Swagelok 8 mm The VFH is a compact, heated pre-filter offering the ultimate in measurement precision and user-friendliness. This means lasting, complete gas-tightness, careful gas flow and compact, careful construction. Pre-Filters The filter chamber has a minimum dead volume and extremely uniform heating with a fast heating-up time, and can accept any IAG filter element. The forward-facing filter fitting seal makes it quick and easy to replace filter elements. Filter Element: A=70 cm2, Backwashable Heated Line Connection: 693 6+Pe Connectors Standard Pin Assignment: 1-L, 2-TC+, 5-TC-, 6-N Alarm Output: 711 Flange Socket Connector Pin Assignment: Pin 1 - Internal Heating (NO) Pin 2 - Heating Line (NO) Pin 3 - COM Power Supply: 230 V / 2,3 kW, 1,5 m / Schuko The heat level is controlled by means of 2 heat controllers with settings made on the front panel. The VFH can optionally be supplied with an alarm output for parameter monitoring. 20 IAG - Industrie Automatisierungsgesellschaft m.b.H · Industriestraße 2 · 2722 Weikersdorf · T +43 2622 21734/77 · F +43 2622 21734/85 · E [email protected] LFS Heated line filter Advantages + Low Price + Maintenance-Free + Robust + Easy Assembly + IAG Filter Chamber Options • • • • Gas Sonnections according Customer Specs High-Temperature Sampling Pt100 Temperature Sensor SilcoTek Surface Treatment Technical Data The LFS is a compact line filter where it is possible for to change the filter without closing off the heated lines. With all IAG pre-filters, great value is placed on the highest measuring accuracy and quality. This means lasting, complete gas-tightness and compact, careful construction. The filter chamber has a minimum dead volume and an extremely uniform heating system with a short warm-up time, and can accept all IAG filter elements. Dimensions: 200 x 120 x 110 mm Sample Gas Inlet: 8 mm Stainless Tube Sample Gas Connections: Swagelok 8 mm Sample Inlet Temperature: max. 200 °C Filter Element: A=70cm2, Backwashable Power Supply: 230 V / 200 W 693 6+Pe / 600 mm Standard Pin Assignment: 1-L, 2-TC+, 5-TC-, 6-N Pre-Filters The LFS is a compact, heated line filter where, thanks to a filter fitting that is decoupled from the housing, it is possible to change the filter without closing off the heated lines. The filter fitting is decoupled from the housing and sealed on the front face, enabling the filter to be changed quickly and easily. For high-temperature sampling, the LFS is equipped with a 300 mm stainless steel corrugated hose on the inlet side. Heat can be regulated using any current temperature regulator. As with every IAG device, the pin assignment and type of temperature sensor can be supplied according to the customer’s wishes. Industriestraße 2 · 2722 Weikersdorf · T +43 2622 21734/77 · F +43 2622 21734/85 · E [email protected] · IAG - Industrie Automatisierungsgesellschaft m.b.H 21 Filter filter cartridge options Technical Data PTFE Compound Ceramic Filters: E-FP-CS Deposition: 99.00% Particles and Aerosols >0.01μm E-FP-DS Deposition: 93.00% Particles and Aerosols >0.01μm E-FP-BS Deposition: 99.99% Particles and Aerosols >0.01μm Stainless Steel Meshwork Filters: E-FP-EM-F2 Deposition: 2 μm Particles E-FP-EM-F5 Deposition: 5 μm Particles E-FP-EM-F10 Deposition: 10 μm Particles Overview of the IAG filter cartridge range. Our wide range of filter cartridges enables individual selection of the optimum filter material and appropriate deposition rate for any situation. Stainless Steel Sinter Filters: E-FP-ES-F3 Deposition: 96 % Partikel > 0.2 μm E-FP-ES-F8 Deposition: 96 % Partikel > 0.04 μm All IAG filters offer the highest quality at an attractive price: once again we guarantee the highest accuracy for your measurements for a constantly low cost. All IAG filters have a filter surface of 70 cm2 and can be installed in any IAG filter chamber. Pre-Filters 22 IAG - Industrie Automatisierungsgesellschaft m.b.H · Industriestraße 2 · 2722 Weikersdorf · T +43 2622 21734/77 · F +43 2622 21734/85 · E [email protected] Ing. Michael Waitz Software Development and Electrical Design Department Manager ”Every client is different. That is our challenge.“ We are inspired by your individual needs Easy operation and easy maintenance as well as compact design are the characteristics that distinguish our measuring systems. Small dimensions, light weight and practical form are essential details with regard to the suitability for everyday application. Individuality motivates us. Besides standards, we realize various features according to your individual needs. Tailor-made solutions are our standard and we look forward to listening to your needs. 23 FLS FTIR sampling system Advantages + Improved Safety + Easy Setup + Low Maintenance + Compact Design + Simple Operation Technical Data Dimensions: 300x460x490 mm Weight: 20kg Sample Gas Connections: Swagelok ¼” Heated Line Connections: 2x Binder 693 Purge Gas Connection: CPI Quick Connect Temperature Range: 5-200°C Adjustable Sample Flow: 2-10l/Min Filter Element: A=70 cm2 Power Supply: 115VAC 60Hz / 230VAC 50Hz The IAG FLS is the ideal additional device to your FTIR to turn it into a complete, simple and safe working measuring build-up. The IAG FLS were designed as additional devices for the simple and safe operation of FTIR analyzers. They provide a fully heated, filtered and adjustable sample gas flow through the analyzer, provided by a reliable heated sample gas pump. Setup is very simple and can be carried out in just a few minutes. Gas Feed It only needs the connection of two heated lines, one to the FTIR and one to the sampling point, network connection, power and purge gas connections. Operation can be done on the device via pushbuttons, or via the provided software which also shows all important FTIR and FLS parameters such as sample flow, gas cell pressure and system temperatures. Before and after measuring the device automatically starts purging the analyzer with nitrogen which will help to avoid costly mishaps such as corrosive probes condensing inside the gas cell. To achieve optimum measuring accuracy all gas contacted surfaces are stainless steel or PTFE with a uniform heating and minimised internal volume. 24 IAG - Industrie Automatisierungsgesellschaft m.b.H · Industriestraße 2 · 2722 Weikersdorf · T +43 2622 21734/77 · F +43 2622 21734/85 · E [email protected] MSJ Gas line switch Advantages + Long Life + Compact + Backflushable + Impervious to Particles + Simple Actuation + Easy Maintenance + Inlet Pressure up to 3 Bar Options • • • • • • • • • IAG MSJ gas line switches are impressive for their extremely compact design, lasting, complete seal tightness and maintenance-friendliness. IAG gas line switches are especially impressive because of their compactness and long life even under heavy usage conditions. As with every IAG device, special attention is paid to careful gas flow with minimal internal volume and no stub lines or undercutting, as well as uniform heating with ample performance for heating up quickly. The MSJs have an in-built heat regulator for internal heating. Control of the compressed-air balanced valve is bit parallel with 24V control voltage. The maximum line diameter for gas inlets for the MSJ 12 is 35 mm. 2 Gas Inlets 2 Gas Inlets and 2 Heating Circuits 4 Gas Inlets 8 Gas Inlets 12 Gas Inlets Gas Connections according Customer Specs Inlet Pressure 6 Bar Modbus RTU / TCP Control SilcoTek Surface Treatment Technical Data Dimensions 2 Inlets: Gas Inlets: Seperately Backflushable Dimensions 4 Inlets: The MSJ 2,4 and 8 are backflushable. The MSJ 2 can be equipped with 2 extra heating circuits for oncoming heated lines. Maximum inlet pressure for all MSJ is 3 bar. All MSJ are available in a high pressure version for max. 6 bar inlet pressure. If an MSJ is connected to an IAG measuring unit, control, parameterisation and monitoring can be carried out via the measuring unit display. 150x390x140 mm 150x300x160 mm 12-inlet Gas Inlets: Seperately Backflushable Dimensions 8 Inlets: 150x400x160 mm Gas Inlets: Seperately Backflushable Dimensions 12 Inlets: 150x390x140 mm Gas Inlets: Backflushable from Emission Bench Inlet Pressure Standard: max. 3 bar Heated Valveblock: max. 200°C Gas Feed Sample Gas Connections: Swagelok 8mm Control Connector: Sub D-15pin Pin Assignment: 1-12 Gas, Inlets/13 Com/14, 15 Alarmrelais Power Supply: 230V/250W IEC Compressed Air: Push in 6 mm, 3-5 bar Industriestraße 2 · 2722 Weikersdorf · T +43 2622 21734/77 · F +43 2622 21734/85 · E [email protected] · IAG - Industrie Automatisierungsgesellschaft m.b.H 25 MGK Compressor Sample Gas Cooler Advantages + Compact Dimensions +High Cooling Power + Stainless Steel Heat Exchanger + Status Indicatore Options • Dewpoint Sensor with Alarm Setting Technical Data IAG MGK Compressor Sample Gas Cooler. The IAG MGK Sample Gas Cooler is a highly compact device, measuring 3HE high and 400 mm deep, but also considering that as a compressor cooler unit it provides adequate power even at high ambient temperatures. All electrical and gas connectors are located on the back of the instrument, while the control panel and the condensate pump are on the front. In this way the complete system can be clearly structured, retaining all gas and energy supply connectors on the back of all units, whereas the status of the gas cooler and the proper functioning of the condensate pump can be viewed from the front panel. Dimensions: 19“x3HEx400 mm Housing: Anodized Aluminium Weight: 14kg Sample Gas Connectors: 6 mm Swagelok Sample Flow Rate: Up to 15 l/Min at 200°C Temperature Stability: +/- 0,3°C Cooling Power: ~200 W Condensate Outlet: 6 mm Swagelok Alarm Output: Binder 711 Power Supply: 230V/500 W Power Supply Connection: IEC Power Socket Gas Feed 26 IAG - Industrie Automatisierungsgesellschaft m.b.H · Industriestraße 2 · 2722 Weikersdorf · T +43 2622 21734/77 · F +43 2622 21734/85 · E [email protected] HSV UREA DISTRIBUTION Analyzing System Automatic calculation of the dot matrix: NOx uniform distribution: Application: The HSV can be connected to round exhaust systems with a diameter of 8 to 14“. The connection is made with a welded flange plate. The sampling system can be positioned and fastened on the flange through a mobile, height and inclination adjustable carrier trolley. The connection point centre height can be electronically adjusted from 500 to 1000 mm. The positioning unit can be pivoted in the range +/-30° around the vertical in order to enable a coupling to the welding flange in this angular range. Implementation: The pipe probe is positioned in the exhaust system via coupled linear drives, which run into pre-parameterized positions in the exhaust system. The probe pipe is heated to 191 °C and has a 6 mm Swagelok connection for a heated analytical line (for analysis) on the output side. In addition, it has a pressure connection for dynamic pressure measurement to determine the flow velocity as well as a thermocouple for temperature measurement at the sampling point. Operation: The operation, monitoring and parametrisation of the system can be carried out directly on the system using the touch display or via the fully configurable AK interface. Advantages Gas Feed The IAG HSV is a heated gas sampling system for analyzing the distribution of gas concentrations as well as the flow velocity and exhaust gas temperature via the cross-section of exhaust systems by means of an automatically positioned pipe probe. + Gas-tight Design + Minimal Disturbance of Gas Flow +Easy Integration into Existing Exhaust Systems + Easy Operation + Mobile on 4 Swivel Castors Technical Data Dimensions: 800 x 1200 x 1500 mm Weight: approx. 185 kg Exhaust Gas Temperature: up to 450 °C Power Supply: 230 V / 50 Hz, Schuko / 10 m Gas Connection: Swagelok 6 mm Industriestraße 2 · 2722 Weikersdorf · T +43 2622 21734/77 · F +43 2622 21734/85 · E [email protected] · IAG - Industrie Automatisierungsgesellschaft m.b.H 27 Stefan Handler Sales and Customer Service Manager ”It is the start that counts, but secure day-to-day operations are key.“ Our service doesn´t stop after the delivery Our routes are as short as they are feasible in both inside our analyzing systems and in after sales service. You are welcome to talk to the technicians directly, who know your units. The results are fast advice and rapid spare part delivery. The basics include individual service contracts from simple maintenance to all-inclusive-packages. The heart of your unit, the spectrometer, is in the best hands as well: We are a certified premium partner of MKS Instruments. TRE08 Temperature controller Advantages + High-Performance Temperature Controller for 8 Control Circuits + Max. 4 x 3 A + 4 x 15 A Options The TRE08 is a high-performance temperature ontroller for supplying long heated hoses for extensive multiple samples or even precise monitoring of multiple control circuits. The TRE08 is far more than just a temperature controller. This is partly because of its enormous performance capability – up to 63A total power consumption on 8 control circuits – and partly because of its versatility in terms of control tasks and communications options. The 8 PID control circuit can safely and precisely manage heated lines, heated/cooled lines, heated sample gas pumps or whatever else is required. Even special tasks such as fast adjustments, parameter switching etc can be carried out using the TRE08. Like all IAG modules, the TRE08 can also be controlled and configured in a wide variety of ways. If active control is needed (such as for controlling an HKL), this can be done either via bit parallel or via Modbus TCP. Depending on the configuration, the TRE08 has up to 8 freely programmable digital outputs that can be used for controlling an MSJ junction unit, for example. 8 Control Circuits max. 4 x 3 A + 4 x 15 A Control of Heated/Cooled Lines Control of Sample Gas Pumps Bit Parallel Control Control of an IAG MSJ Pt100 Temperature Sensor Technical Data Temperature Controller: PID Controller, 8 Control Circuits Parameterisation: Via Modbus TCP or via System Control Panel (SCP) Control: Modbus TCP, AK TCP, Digital Input via Sub-D or System Control Panel (SCP) Pin Assignment: Pins 1, 2, 3 - Digital in, Pin 6 - Com Alarm Output: Sub-D (9-Pin), Pins 7, 8, 9 - NO/NC 3A Heat Supply: 693 6+Pe Flange Socket Connector Standard Pin Assignment: 1-L, 2-TC+, 5-TC-, 6-N 15A Heat Supply: 694 4+Pe Flange Socket Connector Standard Pin Assignment: 1-L, 2-N, 3-TC+, 4-TCMSJ Control: Sub-D (15-Pin) Dimensions: 320 x 400 x 170 mm Power Supply: 400 V / 32 A or 63 A CEE, 3 m / Schuko Test Cell Equipment If the TRE08 is connected to an IAG measuring unit, it will be displayed in the measuring units display and can be fully monitored and configured from there. In the simplest case, the TRE08 can carry out its control functions fully autonomously and can display any interference as a digital signal. Parameterisation is then carried out either via a system control panel (SCP) or with an extremely handy configuration software package via Modbus TCP. • • • • • • Find our other basic temperature controller TRE01 and TRE05 on our homepage www.iag.at 29 TRE01 TRE05 IAG - Industrie Automatisierungsgesellschaft m.b.H · Industriestraße 2 · 2722 Weikersdorf · T +43 2622 21734/77 · F +43 2622 21734/85 · E [email protected] MTS Driver guidance system Advantages + Central Mounting Point + Extensive Range + Elegant Design + One-Hand Operation + Maintenance-Free Options • • • • • • • • Heated Version (up to -30 °C/-22°F) Aircondition (up to 50°C/122°F) 2 CAT5 Ports 8 BNC Ports 1 PG for Cable Outlet 1 Two-Pin Grounded Socket 1 12 V Socket 1 Mushroom-Style Emergency Stop Switch Technical Data The MTS is an extremely elegant and versatile driver aid/ guidance system that is also suited for use in climatic test benches. Thanks to the compact design featuring a central pillar to the ceiling, the MTS has an extremely slim and elegant appearance and requires only one mounting point, making attachment to the test bench much easier than with conventional rail systems. All lines are well protected, running inside and concealed from view. Despite its slim appearance, the MTS is stable enough to easily withstand even high winds. All main axes of movement are unlocked simultaneously, allowing the system to be positioned effortlessly with just one hand. Movement Radius: 2m Minimum Ceiling Height: 3.2 m Monitor: 22” TFT Compressed Air Supply: 6-8 bar, Dry and Oil-Free Power Supply Connection:Two-Pin Grounded Power Supply: 230 V / 2.3 kW Monitor Signal: CAT5 max. 100 m with Signal Amplifier to VGA Test Cell Equipment The monitor is mounted in a durable, heatable case featuring handles for positioning as well as operator controls and signal transfer interface, all of which are arranged ideally to facilitate work. Thanks to tremendous ease of operation and its elegant appearance, the MTS driver aid system will contribute appreciably to enhancing the working climate at your test benches. 30 IAG - Industrie Automatisierungsgesellschaft m.b.H · Industriestraße 2 · 2722 Weikersdorf · T +43 2622 21734/77 · F +43 2622 21734/85 · E [email protected] Ing. Rainer Pokorny Technical Manager ”It starts with listening. It ends with the most suitable solution.“ Understanding your needs Our customers know what they want. Our challenge starts where conventional exhaust gas measurement reaches its limits - high temperatures, high pressures, long gas lines, difficult sampling points, short response times and free choice of analyzers. Our customers‘ individual requirements drive us to create new unique products we are truly proud of. 31 IAG - Industrie Automatisierungsgesellschaft m.b.H IAG - Industrie Automatisierungsgesellschaft m.b.H · Industriestraße 2 · 2722 Weikersdorf T +43 2622 21734/77 · F +43 2622 21734/85 · E [email protected] · www.iag.at
© Copyright 2026 Paperzz