Double membrane Biogas storage This picture is an example of a biogas storage Project 15062 Lloyd England www.schanflex.com Double membrane Biogas storage 1. 2. 3. 4. 5. 6. 7. outer membrane Inner membrane Cord band Ventilation Ultrasonic sensor for gas volume measuring Mounting bracket Peephole A double membrane biogas storage consists of a shaped outer and inner membrane, inner membrane forms the actual delimitation of the gas storage facility. Inner membrane change the size depending of gas accumulation and taps. An air blower, which runs constantly, keeps up outer membrane, it ensures to cover the difference between the outer and inner membrane all time. Biogas storage equipped with a pressure relief device. Material used for the membranes is a polyester fabric with double-coated lacquered PVC coating. Schanflex is of course the right to ask, in the case of ordinary and gas tight covers. www.schanflex.com Documentation Volume Project name: 15062 Lloyd England Diameter: 17800 mm Outer membrane: Inner Membrane: Height: 6000 mm Height: 5000 mm Mast height over tank edge: 1300 mm Volume: 675 m³ www.schanflex.com