A solut power supply ,500KW
rupted m 50KW to 2
fro
Power
«
AUSAR ENERGY is specialized in designing, manufacturing
and supplying solar power plants integrating energy storage capabilities.
Our innovative solutions, based on reliable and well-tried technologies,
are able to meet the energy needs of countries with very high demographic
and economic growth rates while at the same time allowing
for an extremely short return-on-investment time.
»
Sensitive sites
The solar plants developed by AUSAR ENERGY provide sensitive sites with energy security,
enabling them to keep on operating when the public grid is experiencing blackouts.
Environmentally
friendly
Blackouts
free
Power
Process
industry
Financial
return
Service life
Hospitals
Server
centers
Fast
deployment
Banks
Premium
-quality
electricity
Agri-food
processing
Stealth
Evolutivity
Fiabilité
AUSAR ENERGY power plants enable sensitive sites to keep on operating when power cuts strike.
Even during long power cuts, the solar generator provides sufficient autonomy to the site without
systematically resorting to the emergency power generator. The continuity of the business processes
is ensured and the economic profitability of the site is maintained.
Thanks to the plant-integrated
power storage system, the
continuity of the energy supply
is ensured 24 hours a day, 7 days
a week. A power generator is
provided with the plant or taken
from the existing installation,
acting as a backup system when
needed even when there has
been no sunshine for a very
long period of time.
.
..
.
..
..
.
.
Flexibility and adaptability
Injection power configurable from 1.2MW to 4.8MW by step of 1.2MW.
Can supply power to high-power electric motors, pumps and lighting systems
Evolutivity
Easily adaptable to evolving needs through the simple addition of storage technical modules,
injection and photovoltaic generation
The plant has been designed so that it can be easily integrated into a newly installed public
grid. When connected, the plant injects the excess of its production to the public grid and thus
operates as an uninterruptible power supply (UPS)
Performance
The robustly designed steering algorithm is easily adaptable to meet the grid manager’s
demands
Transportation and installation
The plant is factory-preconfigured and installed inside of 20-feet containers transportable by
ship or by road.
The on-site installation of the plant simply consists in installing the solar panels, interconnecting
electricity between the containers and connecting the transformer station to the public grid.
A service life of 30 years
Deployment and maintenance
Teleprocessing and management are carried out remotely by our technical central station
No human intervention is needed under normal conditions of operation
Level 1 maintenance is carried out locally by AUSAR ENERGY-trained teams
Level 2 maintenance operations are assisted remotely by our technical central station
Uninterrupted power supply
A backup power generator ensures that power is supplied even when there has been reduced sunlight for a long period. This backup power generator can either be provided by AUSAR ENERGY or taken from the existing installation.
An environmentally friendly energy solution
From its manufacture until its end-of-life dismantling, the plant contributes to the reduction of greenhouse gas emissions
Solar power (@ 25°C – 1,000W/m2) ……………………………………… up to 12MWp
Ground surface area………………………………………………………… 2ha per 1MWp
Electrical power in stable conditions of operation…………………… 37 kVA to 1,850kVA
Maximum electric power in stable conditions of operation………… +30% during 1 minute
Alternating current characteristics:
Three-phase 50Hz / 60Hz +/- 0.1 Hz
Nominal : 380Vac / 400Vac between phases, 220 Vac / 230 Vac between phase and neutral
Maximal : 440 Vac at the head of the distribution network
Waveform : pure sinus
Harmonic distortion < 5%
Voltage stability of
+/- 3% in continuous operation
<10% for a power change of 100%
Maximum power of the backup portable generator……………………………… 3,000 kVA
Storage capacity of the batteries……………………………………..120 kWp to 6,000 kWp
Maximum number of DOD 30% battery cycles…………………………3,000 cycles / 8 years
Storage capacity per fuel cell / flywheel…………………………. project under development
Protection against :
Excess load, on-power, short-circuit, high voltage and low voltage, temperature,
excessive discharge of the battery, lightening
Local monitoring, remote monitoring and maintenance with landline phone, GPRS,
satellite or radio transmission
MTBF (Mean Time Between Failures)………………………………………… 30,000 hours
MTTR (Mean Time To Repair)………………………………………………………… 1 hour
Service life of the system…………………………………………………………… 30 years
Solar
generator
50kWp to
2.5MWp
Charge controller with MPPT
=
=
Inverter 37kW
to 1.850MW
Public grid
DC bus 480V
=
Rectifier
Power
generator
0 to 3MVA
=
Batteries
from
120kWh to
6,000kWh
=
Tél 00 33 472 756 156
[email protected]
4, chemin du Ruisseau
69130 Ecully - France
ausar-energy.com
Sensitive
sites
Three-phase
grid 440V max
Photo : Kevin Miller - Shutterstock
Rectifier