home inspection report Home. Safe. Home. Each office is independently owned and operated. | ©2013 The HomeTeam Inspection Service, Inc. All rights reserved. What is a home inspection? The purpose of a home inspection is to visually examine the readily accessible systems and components of the home. The inspectors are not required to move personal property, materials or any other objects that may impede access or limit visibility. Items that are unsafe or not functioning, in the opinion of the inspector, will be described in accordance with the standards of practice by which inspectors abide. What does this report mean to you? This inspection report is not intended as a guarantee, warranty or an insurance policy. Because your home is one of the largest investments you will ever make, use the information provided in this report and discuss the findings with your real estate agent and family to understand the current condition of the home. Our inspections exceed the highest industry standards. FAST Because we use a team of inspectors, each an expert in his or her field, our inspections are performed with greater efficiency and more expertise and therefore exceed the highest industry standards. We are pleased to provide this detailed report as a service to you, our client. TRUSTED We believe in your dream of home ownership. We want to help you get into your dream home. Therefore, we take great pride in assisting you with this decision making process. This is certainly a major achievement in your life. We are happy to be part of this important occasion and we appreciate the opportunity to help you realize your dream. We exceed your expectations. Buying your new home is a major decision. Much hinges on the current condition of the home you have chosen. That is why we have developed the HomeTeam Inspection Report. Backed by HomeTeam’s experience with hundreds of thousands of home inspections over the years, the report in your hand has been uniquely designed to meet and exceed the expectations of today’s homebuyers. We are proud to deliver this high-quality document for your peace of mind. If you have any questions while reviewing this report, please contact us immediately. Thank you for allowing us the opportunity to serve you. ACCURATE MasterInspector:Bill Sample AddressofInspection:123 Sample Drive, Louisville, KY Bill Sample 123 Sample Drive, Louisville, KY Page2of30 MasterInspector:Bill Sample AddressofInspection:123 Sample Drive, Louisville, KY SUMMARY Thefollowingisasummaryofourfindings.Manyofthefindingspresentedbelowdonotriseto thelevelofamajordiscrepancybutarelistedasaservicetotheclientinordertogiveafuller pictureofthestateofthehome. SafetyConcerns Atleastoneofthesmokealarmsismissingabattery Someoftheroomsinthehomeweremissingsmokealarms TheGFCIoutletlocatedintheupstairsbathroomisdefective Exposedlivewireswereobservedintheupstairsrightbedroom Exterior Crackswerepresentonthebrickcladdingofthehome Rottedwoodwaspresentaroundthefrontdoor Holeswerenotedonthebackandrightsidesofthehome'sexterior Exteriorlightfixturesareloose Thedryerventcoverismissing Plumbing Thedrainlineunderthekitchensinkleaks Electrical Missingoutletcoverswereobservedinthegarage Alightfixtureinthemasterbedroomisloose Alooseoutletwasobservedintheupstairsleftrearbedroom Oneormoreexterioroutletswerenotproperlycovered,allowingrainwatertoenterthecircuit Interior,Windows,Doors Abrokenbalusterlocatedonthestaircaseleadingtothesecondfloor Therearexteriordoorhasabrokendeadbolt Asubstancewiththecharacteristicsofmoldisvisibleinoneormoreareasoftheproperty Kitchen Thedisposalisnotoperable HVAC ThefurnacerequirescleaningandservicingbyaprofessionalHVACtechnician TheHVACsystemairfilterisextremelydirty Note-thissummaryispresentedtoassistinthepresentationofinformationandshouldneverbesolely reliedupon.Thereportshouldbereadandunderstoodinitsentirety,andtheinclusionoromissionof certainitemsinthesummarydoesnotindicateanyrelativeimportanceorspecialsignificance.Itis Page3of30 MasterInspector:Bill Sample AddressofInspection:123 Sample Drive, Louisville, KY importantforclientstoworkcloselywiththeirREALTORindevelopinganyrepairrequests.Pleasecontact HomeTeamforclarificationofanyitemsinthisreport. Page4of30 MasterInspector:Bill Sample AddressofInspection:123 Sample Drive, Louisville, KY Ahomeinspectionisintendedtoassistinevaluationoftheoverallconditionofthedwelling.Theinspectionisbased onobservationofthevisibleandapparentconditionofthestructureanditscomponentsonthedateofthe inspection.Wewillnotrenderanopinionastotheconditionofanysystemsorcomponentsofthestructurethatare concealedbywalls,floors,drywall,paneling,suspendedceilingtiles,insulation,carpeting,furnitureoranyother itemsonthepropertyatthetimeoftheinspection. Theresultsofthishomeinspectionarenotintendedtomakeanyrepresentationregardingthepresenceorabsence oflatentorconcealeddefectsthatarenotreasonablyascertainableinacompetentlyperformedhomeinspection.No warrantyorguarantyisexpressedorimplied. Youmaybeadvisedtoseekaspecialist'sopinionastoanydefectsorconcernsmentionedinthereport.Atthat time,additionaldefectsmayberevealedthatmaynothavebeenidentifiedintheinitialhomeinspection.Thisispart ofthenormalduediligenceprocess. Iftheage,conditionoroperationofanysystem,structureorcomponentofthepropertyisofaconcerntoyou,we recommendthataspecialistintherespectivefieldbeconsultedforamoretechnicallyexhaustiveevaluation. Thisinspectionreportincludesadescriptionofanymajorvisualdefects*notedduringtheinspection,alongwithany recommendationthatcertainexpertsberetainedtodeterminetheextentofthenameddefectsandotherrelated defectsandanycorrectiveactionthatshouldbetaken.Anymaterialdefectthatposesanunreasonableriskto peopleonthepropertywillbeconspicuouslydefinedassuch.Anyrecommendationsmadetoconsultwithother specialistsforfurtherevaluationasaresultofourfindingsshouldbecompletepriortotheconclusionofthe inspectioncontingencyperiod.Thismayrequireanextensionoftheperiod.TheClientwarrantstheywillreadthe entireInspectionReportwhenreceivedandshallpromptlycontactHomeTeamregardinganyquestionsorconcerns theClientmayhaveregardingtheinspectionortheInspectionReport. * MajorVisualDefect:Aproblemwitharesidentialrealpropertyoranyportionofitthatwouldhaveasignificant adverseimpactonthevalueoftheproperty,oronethatinvolvesanunreasonablerisktothepeopleontheproperty. Thefactthatastructuralelement,systemorsubsystemisnear,atorbeyondtheendofthenormalusefullifeof suchastructuralelement,systemorsubsystemisnotbyitselfadefect. Themajorityofhomeinspectionsareperformedonpre-existingstructures.Buildingtechniqueshavechanged dramaticallyovertheyears,andahomeinspectionisnotdesignedtoidentifymethodsthatwerepreviously acceptablethatmayhavebeensupersededbysuperiormethods.Wewillnotdeterminethecauseofanyconditionor deficiency,ordeterminefutureconditionsthatmayoccur,includingthefailureofsystemsandcomponentsor consequentialdamage. Itisnotuncommontoobservecracksorforcrackstooccurinconcreteslabsorexteriorandinteriorwalls.Cracks maybecausedbycuringofbuildingmaterials,temperaturevariationsandsoilmovementsuchas:settlement, unevenmoisturecontentinthesoil,shockwaves,vibrations,etc.Whilecracksmaynotnecessarilyaffectthe structuralintegrityofabuilding,cracksshouldbemonitoredsothatappropriatemaintenancecanbeperformedif movementcontinuesatanabnormalrate.Properfoundationmaintenanceiskeytothepreventionofinitialcracksor cracksenlarging.Thisincludes,butisnotlimitedtoproperwatering,foundationdrainageandremovalofvegetation growthnearthefoundation. Page5of30 MasterInspector:Bill Sample AddressofInspection:123 Sample Drive, Louisville, KY CONFIDENTIALITY Thisreportisintendedforthesole,confidential,andexclusiveuseandbenefitoftheClient(s)undera writtenHomeTeamInspectionAgreement.Thisreportisnotintendedforthebenefitof,andmaynotbe relieduponby,anyotherparty.Thedisclosureordistributionofthisreporttothecurrentowner(s)ofthe propertyinspectedortoanyrealestateagentwillnotmakethosepersonsintendedbeneficiariesofthis report.TheHomeTeamInspectionServicehasnoliabilitytoanyparty(otherthantheHomeTeamclient namedabove,forwhomthisreportwasexpresslyprepared)foranyloss,damageorexpense(including, withoutlimitation,attorneyfees)arisingfromanyclaimrelatingtothisreport. Asconditionsinahomecanchangefromthetimeoftheinspectiontothetimeofclosing,HomeTeam stronglyrecommendstheclientperformathoroughwalkthroughshortlypriortoclosing,turningonall faucets,flushingtoilets,testinggarbagedisposals,turningonthefurnaceandairconditioner,andlooking foranyleakage,signsofwaterintrusion,stains,orotherchangesthatmayhaveoccurredsincethetimeof theinspection. Anydefectsnotedinthebodyofthereportshouldbeaddressedbyaprofessionalinthatfieldwithinthe duediligenceperiod.Additionalassessmentsmayuncovermoreextensivedamageorneededrepairs. Ourrecommendationsforrepairmay,intheopinionofanotherprofessional,requirereplacementofthe part,component,oritem.Insomecases,replacementisthemorefeasibleoptiongivenvariousother factors,suchascomponentandlaborcostsanddepreciatedvalue. Anyrecommendationstocleanorservicetheheatingandairconditioningsystemsareunderstoodto includeanassessmentofHVACcomponentsatthattime.Servicinggenerallyincludescleaningthe systems,replenishingrefrigerant,andperformingmoredetailedanalysisandassessmentwhichmay revealfurtherneededrepairs. Allpicturesthatmaybeincludedaretobeconsideredasexamplesofthevisibledeficienciesthatmaybe present.Ifanyitemhasapicture,itisnottobeconstruedasmoreorlesssignificantthanitemswithno pictureincluded. Page6of30 MasterInspector:Bill Sample AddressofInspection:123 Sample Drive, Louisville, KY INTRODUCTION Asystemorcomponenthasamajorvisualdefectifitiseitherunsafeornotfunctioningandcannotbe replacedorrenderedsafeorfunctionalforlessthan$1,000.Thecosmeticconditionofthepaint,wall covering,carpeting,windowcoverings,toincludedrywalldamage,etc.,isnotaddressed.Allconditionsare reportedastheyexistedatthetimeoftheinspection.Routinemaintenanceandsafetyitemsarenotwithin thescopeofthisinspectionunlesstheyotherwiseconstitutemajor,visuallyobservabledefects.Although somemaintenanceand/orsafetyitemsmaybedisclosed,thisreportdoesnotincludeallmaintenanceor safetyitemsandshouldnotberelieduponforsuchitems.Commoncosmeticitems,suchasnailpops, tapelifts,andsettlementordrywallcracksanddamagearenotaddressedinthisreport.Theclientshould beawarethatoneofthemostcommonandseriouscausesofdeteriorationtoahomeiswaterintrusion frombothexteriorandinteriorsources.HomeTeamlooksforevidenceofdamageaswellascluesthat damagemayhaveoccurredorisimminent.However,manyfactors,includingrecentlypaintedorobscured areasorperiodsofrecentdryness/lackofrain,mayhidethosecluesfromusatthetimeoftheinspection. Additionally,someareasmayonlyshowsignsofleakageduringrainyperiods(exteriorwater)orprolonged usage(plumbing).Itisimperativethatthebuyerremainvigilantforanywaterintrusion,andifanyis experienced,thatitberepairedassoonaspossible.Routineregradingofexteriorlandscapingshouldbe accomplishedatleastannuallytohelpensureproperdrainageawayfromthehome'sfoundation. Generally,propergradingisapproximately5percent,oraboutsixinchesdeclineinthefirsttenfeetaway fromthehome.Itisnotuncommontoobservecracks,orforcrackstooccurinconcreteslabsorexterior andinteriorwalls.Cracksmaybecausedbycuringofbuildingmaterials,temperaturevariationsandsoil movementsuchassettlement,unevenmoisturecontentinthesoil,shockwaves,vibrations,etc.While cracksmaynotnecessarilyaffectthestructuralintegrityofabuilding,cracksshouldbemonitoredso appropriatemaintenancecanbeperformedifmovementcontinuesatanabnormalrate.Properfoundation maintenanceiskeytothepreventionofinitialcracksorcracksenlarging.Thisincludes,butisnotlimitedto properwatering,foundationdrainageandremovalofvegetationgrowthnearthefoundation. Ahomeinspectionisnotahomewarranty,andHomeTeamstronglyrecommendspurchasinga homewarrantyfromareputablecompanytocoveritemsthatwillfailinthecourseoftime.Consult withyourHomeWarrantyprovidertodetermineifanyspecificcomponentsrequireamoredetailed inspectionthanthatprovidedbyASHIstandards. Asareminder,accordingtothefirmofHSHAssociates,typicalannualmaintenancecostsforahomearea minimumofapproximatelyonepercentofpurchaseprice. Structuresthathavenotbeenoccupiedforaperiodoftimemaypresentuniqueproblemswhen theyarere-occupied.Somestructuralandmechanicalcomponentsandsystemsthathavenot beenusedonadailybasismaymalfunctionorpresentmaintenanceissuessoonafterbeing placedbackintodailyservice,includingplumbingsystemsanddisposals.Werunlotsofwater duringtheinspection;westopupsinksandtubslookingforleaks;weflushtoiletsaminimumof 3times.Nevertheless,avacanthomecomeswithacertainamountofriskassociatedwithit:leaks maydevelopandareoftenatdishwashers,faucetsandothersupplyconnectionsandlinesandat drainlineconnections.Thesearesometimescausedbyexcesssedimentsettlinginsupplylines anddrainlinesandbysealsandwashersdryingoutinvalves,drainfittings,andother areas.Flappervalvesandotherinternalpartsoftoiletsmaybedeterioratedandfail.Although somewhatrare,sewerlinescanbecomeobstructedandbackupseveraldaysafterthehomeisrePage7of30 MasterInspector:Bill Sample AddressofInspection:123 Sample Drive, Louisville, KY occupied.Sedimentthathardensinsideadrainlineorsewerpipethathasbeendryforan extendedperiodoftimecanbreaklooseandclogtheline.Thisisusuallyremediedbyroutine sewerauguringservice.HomeTeamrecommendscarefullymonitoringsupplyanddrainlines,and waitingatleastoneweekbeforeplacingpersonalitemsundersinkstoensureanylatentleakage problemsmanifestduringtheinitialtimeofoccupancy.Anyslowdrainsobservedduringinitial occupancyshouldbemonitoredandclearedasneeded. Therewasasignificantamountofdeferredmaintenancepresentthroughoutthepropertyandexterior groundsatthetimeoftheinspection.Thispropertyprobablyneedssignificantrenovation,remodeling, refurbishment,orrehabilitation.Whilewestrivetoprepareanaccuratereportoftheconditionofthe propertyatthetimeoftheinspection,itisvirtuallyimpossibletocompileanexhaustive,complete,or definitivelistofdefectsandareasofconcerninthesecircumstances.Duetothetime-limitednatureand generalizationsinherentwithahomeinspection-aswellasareasofthepropertynotbeingvisible,not beingaccessible,orbeingconsidereddangerousandunsafe-theinformationcontainedinthisreport shouldnotbeconstruedasanexhaustive,complete,ordefinitivelistofdefectsandareasofconcern. Renovationofthisproperty,oranypartofthisproperty,mayexposeadditionaldefects,whichwerenot notedorwerenotvisibleatthetimeoftheinspection. Theapproximatetemperatureatthetimeoftheinspectionwas75to80degreesFahrenheit,andthe weatherwascloudy.Theutilitieswerenotonatthetimeoftheinspection.Theageofthehomeappeared tobe11years. LOTANDGRADE Thehomewassituatedonaleveltoslopedlot.Thegeneralgradearoundthehomeappearedtobe adequatetodirectrainwaterawayfromthefoundation,assumingnormaldrainageanddownspout,gutter, andothersystemsarefunctioningproperly. STRUCTUREANDCLADDING Theinspectedpropertyconsistedofatwostorywood-framedstructurewithbrickandvinylcladdingthat wasvacantatthetimeoftheinspection. NOTE-Peelingpaintwaspresentontheexteriorofthehome.Inordertopreservethelifeoftheexterior surfacesandmaterials,allareasshouldbescraped,sealed,andpaintedafteranydamagedwoodis repaired.Thisisaroutinemaintenanceitem. NOTE-steellintelsabovethewindowsontheexteriorofthehomeisrustingandappearstohave expanded.Lintelssupportmasonrymaterialsabovedoorsandwindows.Keepingthelintelssealedwill helppreventrustingandexpansion.Expandedlintelscanleadtocracksinthemasonryontheoutsideof thehome.Theaffectedlintelsshouldbeproperlysealedtopreventfurtherexpansion. Rottedwoodwaspresentonthefrontdoor.Theareasshouldberepairedandfurtherevaluatedatthe timeofrepair. Page8of30 MasterInspector:Bill Sample AddressofInspection:123 Sample Drive, Louisville, KY Photo1 exampleofrottedwoodaroundthefrontdoor Crackswerepresentonthebrickveneerofthehome.Thecrackswerelocatedonthefront.The cracksarecommonanddonotusuallyhaveanystructuralsignificance.Nostructuralconcernonthebrick veneerwasnoted.Allcracksshouldbemonitoredforsignificantchangesincharacteristics.Thecracks shouldbesealedtopreventwaterintrusionbehindthebrick. Photo2 mortarcrack Holeswerenotedontherightandbacksidesofthehome'sexterior.Thisconditiondoesnothave anyeffectonthestructuralintegrityofthebuilding.Theareasshouldberepairedtopreventwater intrusion. Page9of30 MasterInspector:Bill Sample AddressofInspection:123 Sample Drive, Louisville, KY Photo4 Photo3 exampleofdamagedsiding exampleofdamagedsiding NOTE-Exteriorhosebibsdidnotfunctionwhentested.Duringwintermonthsandtimesofcolder temperatures,homeownersoftenturnoffhosebibsfromtheinteriortopreventpipesfromfreezingand bursting.Duetothepossibilityofuncontrollableleaksatthefaucethandleifactivated,HomeTeamdoes notactivateshutoffvalves.Oncetemperaturesremainsafelyabovefreezingtheclientshouldcheckthe hosebibsforproperoperation. NOTE-thedoorbelldidnotfunctionwhentested. Exteriorlightfixturesarelooseandshouldbesecured. Thedryerventcoverismissing.Theventcovershouldberepairedorreplacedtopreventbirdsorother smallanimalsfromenteringthehome. Photo5 missingdryerventcover MasterInspector:Bill Sample AddressofInspection:123 Sample Drive, Louisville, KY NOTE-Althoughthevinylonthefluechaseisnotloosethereareareasthatappeartobebuckled.These areasshouldbemonitoredforanyneededrepairsandrepairedasnecessary Photo6 buckledvinyl GASMETER Thegasmeterandmainshutoffwerelocatedontherightexteriorwall.Therewasnonoticeableodorof gasdetectedatthetimeoftheinspection. Safetynote-HomeTeamrecommendsthatallhomeswithnaturalgassupplylinesbeprotectedwithCO monitorslocatedinareaswhichwillmostimprovethesafetyofthehome'soccupants. GUTTERS Theroofdrainagesystemconsistedofaluminumguttersanddownspoutswhichappearedtobefunctional atthetimeoftheinspection.Guttersanddownspoutsshouldreceiveroutinemaintenancetoprevent prematurefailureanddrainageproblemsthatmayleadtowaterintrusion.Observationoffasciabehindthe guttersisobscuredbythegutters.Keepingthegutterscleanwillhelpreducethelikelihoodofoverflows andresultingdamagetofascia.Homeownersshouldbeawarethatguttersthathavebeendirtyorclogged foranextendedtimemayhaveledtounobservabledamagetofasciaorroofingcomponents. Waterflowfromdownspoutextensionsorsplashblocksshouldbecarriedseveralfeetfromthefoundation towardsadownslopetoensurewaterdrainswellawayfromthefoundation.Thesemeasureswillhelp ensureexcessivewaterisnotdepositedincloseproximitytothefoundation,whichcanleadtointerior waterintrusion,particularlyduringperiodsofheavyrainorwater-saturatedsoil.Aproperly-functioning drainagesystemisoneofthemostimportantitemsforextendingthelifeexpectancyofahouseandits components. Page11of30 MasterInspector:Bill Sample AddressofInspection:123 Sample Drive, Louisville, KY Photo7 gutters Severaldownspoutsweredrainingatortooclosetothebaseofthefoundation.Toreducethe likelihoodofwaterproblemsatthebaseofthehome,allroofdrainageshouldbedirectedatleastsixfeet fromthebaseofthefoundation. Photo8 severaldownspoutsaredrainingadjacentto thefoundation Page12of30 MasterInspector:Bill Sample AddressofInspection:123 Sample Drive, Louisville, KY ROOF Theroofwasagabledesigncoveredwithasphalt/fiberglassshingles.Observationoftheroofsurfacesand flashingwasperformedfromaladderattheeavesduetoexcessivepitch,andwiththeaidofanaerial drone.Therewasonelayerofshingles. Theroofshinglesexhibitedlightcurlingandmoderatesurfacewear.Severalareasweretestedforlifted edges,andliftededgeswerenotobserved.Nailpopswereobserved.Evidenceofahaileventwasnot observed. Previousrepairswerenotobserved. Theseconditionsindicatetheroofshingleswereinthesecondhalfoftheirusefullife. NOTE:Sometimesouropinionofaroofmaydifferfromthatofaninsuranceprovider/adjusterorroofer. Someinsuranceproviders/adjustersorroofersaremoreparticularthanothers.Wearetheretostatethe overallconditionoftheroof;theroofisnotconsideredtobedefectiveunlesstherearevisibleleaksand/or majordamageorwearthatindicatesfailureisimminent.Ifwenoteanymoderatetoseriouscurlingor surfacewear,liftededges,orevidenceofahailevent,werecommendgettingasecondopinionregarding theroof.DuetorecentlargeinsurancelossesinKentuckyandIndiana,manyinsuranceprovidershave beguntorequireroofreplacementsorsignificantrepairspriortoinsuringaroof.Unlesstheroofisonlya fewyearsold,itisprudenttohaveyourinsuranceproviderlookattherooftoconfirminsurability.Wedo notmakeinstallationjudgmentsregardingroofcovering,appropriatepitch,etc. Photo9 Photo10 Page13of30 MasterInspector:Bill Sample AddressofInspection:123 Sample Drive, Louisville, KY Photo11 Photo12 CHIMNEYSANDFLUES Thehomehadonefluechase.Observationofthefluechasewasmadefromthegroundwiththeaidof binoculars.Theflashingaroundtheroofpenetrationpointwasnotobservable. DRIVEWAY Aconcretedrivewayispresentinthefrontofthehome.Cracksandspallingwereobservedonthe driveway.Surfacedefectsindrivewaysdevelopandprogresswithageandareconsiderednormalaslong astheydonotcreateasafetyhazard.Sealingdefectsmayhelpslowtherateofdeterioration. GARAGE Theattachedgaragewasdesignedfortwocarswithaccessprovidedbyoneoverhead-styledoor.The garagefloorwasinfaircondition. Theautomaticgaragedooropenerwasnottested.Themotorwasnotconnectedtothegaragedoorat thetimeoftheinspection.Thegaragedoorwasopenedmanuallyandwasfunctional. Page14of30 MasterInspector:Bill Sample AddressofInspection:123 Sample Drive, Louisville, KY ATTICSTRUCTURE Theatticwasaccessedviaascuttleinabedroomclosetandwasentered. Theatticabovethelivingspacewasinsulatedwithfiberglassbattedandloosefillinsulation,approximately ten-inchesindepth. Ventilationthroughouttheatticwasprovidedbygable,soffitandroofvents.Theatticventilationappeared tobeadequate. Theroofstructureconsistedoftwo-inchbyfour-inchwoodtrussesspaced24inchesoncenterandOSB (waferboard)sheathing. Therewasnomoisturevisibleintheatticspace. Aswithallaspectsofthehomeinspection,atticandroofinspectionsarelimitedinscopetothevisibleand readilyaccessibleareas.Duetoconfiguration,partsoftheatticwerenotaccessible.Manyareasofthe roofarenotvisiblefromtheatticespeciallynearthebase,wherethelargestvolumeofwaterdrains.The presenceoractivestatusofroofleakscannotbedeterminedunlesstheconditionswhichallowleaksto occurarepresentatthetimeoftheinspection,ie,heavyraincombinedwithhighwinds.Pleasebeaware thatrainaloneisnotalwaysaconditionthatcausesaleaktorevealitself.Theconditionsthatcauseleaks tooccurcanofteninvolvewinddirection,thelengthoftimeitrains,etc. Photo13 Photo14 Page15of30 MasterInspector:Bill Sample AddressofInspection:123 Sample Drive, Louisville, KY Photo15 Photo16 Partsoftheatticshowsignsofpreviouswaterintrusion.Theareasweredryatthetimeoftheinspection. Thebuyershouldmaintainvigilanceinmonitoringtheareasforanyrecurrenceofthepreviousissueand shouldrectifyanyissuesimmediatelyuponobservingthem. ELECTRICSERVICE Theundergroundelectricservicewireenteredthehomeontherightwall.Theelectricmeterwaslocated ontheexteriorwall. Theservicewireappearedtobe120/240voltand200ampandenteredaSquareDservicepanel,located ontherightgaragewall.Themainservicedisconnectwas200-ampratedandwaslocatedinthemain panel.Thebranchcircuitswithinthepanelwerecopperandaluminum.Thesebranchcircuitsandthe circuitbreakertowhichtheywereattachedappearedtobeappropriatelymatched.Theinternal componentsoftheservicepanel,i.e.mainlugs,busbars,etcwereingoodcondition. ThevisiblehousewiringconsistedprimarilyoftheNM(non-metallic)typeandappearedtobeingood condition. Theelectricalserviceappearedtobeadequate.Asareminder,alarms,electronickeypads,remotecontrol devices,landscapelighting,telephoneandtelevisionwiringarebeyondthescopeofthisinspection. Page16of30 MasterInspector:Bill Sample AddressofInspection:123 Sample Drive, Louisville, KY Photo17 Arepresentativenumberofinstalledlightingfixtures,switches,andreceptacleslocatedthroughoutthe homeweretested.Thegroundingandpolarityofreceptacleswithinsixfeetofplumbingfixtures,andthose attachedtogroundfaultcircuitinterrupters(GFCI),ifpresent,werealsotested,althoughwedonotcheck alllightswitchesoroutletstodeterminewhichspecificoutletsorlightfixtureseachisconnectedto. TheinstallationofGFCIprotectedcircuitsand/oroutletslocatedwithinsixfeetofwater,nearkitchen countertops,inunfinishedbasementareas,garageandtheexteriorofthehomeisacommonlyaccepted practiceandrequiredbymanymunicipalities.AllGFCIreceptaclesandGFCIandAFCIcircuitbreakers shouldbetestedmonthly. Pleasenotethatelectricalcodeshavechangedthroughtheyears.Althoughthehomedoesnotneedto meetcurrentcodeforarealestatetransaction,anyworkanelectriciandoesmustmeetthecurrentcode requirements.Often,electricianswillrecommendchangesthat,inthecontextofarealestatetransaction, areconsideredupgradesratherthannecessaryrequirements.Keeptheseitemsinmindifnegotiating repairs. TheGFCIoutletlocatedintheupstairsbathroomisdefectiveandshouldbereplaced. Missingoutletcoverswereobservedinthegarage.Allswitchandoutletboxesshouldbeproperly coveredtoavoidashockhazard.Electricalrepairsshouldbeperformedbyaqualifiedelectrician. Exposedlivewireswereobservedintheupstairsrightbedroom.Thewiresshouldeitherbe disconnectedatthesourceorproperlyterminatedinanapproved,coveredelectricalbox.Consultwitha qualifiedelectricianforrepairandfurtherassessment. Page17of30 MasterInspector:Bill Sample AddressofInspection:123 Sample Drive, Louisville, KY Photo18 Exposedlivewires. Alooseoutletwasobservedintheupstairsleftrearbedroom.Thiscouldbeashockhazarddueto exposedelectricalcontacts.Theaffectedoutlet(s)shouldbereplacedbyaqualifiedcontractor. Oneexterioroutletswerenotproperlycovered,potentiallyallowingrainwatertoenterthecircuit. Outletcoversdesignedforuseinwetlocationsshouldbeinstalledonallexterioroutlets. Photo19 outletisnotproperlycovered FOUNDATION Thefoundationwasconstructedofaslabongrade.Asingleinspectioncannotdeterminewhether movementofafoundationhasceased.Anycracksshouldbemonitoredregularly. Page18of30 MasterInspector:Bill Sample AddressofInspection:123 Sample Drive, Louisville, KY Thefullslabwasnotvisibleatthetimeoftheinspectionbecauseofcarpetorotherfloorcoverings.There werenoindicationsofmoisturepresent.Therewerenomajorvisualdefectsobservedonthevisible portionsoftheslab.Pleasenotethattheconditionofanyutilitieswithinorunderaslab-on-grade,suchas plumbingorductwork,arenotwithinthescopeoftheinspection.Duetothenatureandexpenseofthese items,HomeTeamrecommendshavingdrainlinesscopedbyaplumber.Thisisparticularlyimportantin olderhomessincedrainlineproblemsarehiddenfromview. PLUMBING ThevisiblewatersupplylinesthroughoutthehomewerecopperandCPVCpipe.Watershutoffvalvesare nottestedaspartofthehomeinspectionsincewatershutoffvalvesthathavenotbeenoperatedforan extendedperiodoftimeoftenleakafterbeingoperated,andwewouldnotbeabletorepairaleakingvalve duringthehomeinspection. ThevisiblewastelinesconsistedofPVCpipe.Thefunctionaldrainageofthedrainwastelinesappearedto beadequateatthetimeoftheinspection.Thefunctionalityofwashingmachinedrainsorunder-floordrain linesisoutsidethescopeoftheinspection.Theselinesareconsideredundergroundutilitiesandare specificallyexcluded.Thelinesarenotvisibleoraccessible,andtheirconditioncannotbeverifiedduringa visiblehomeinspection.Simplyrunningwaterintofloordrainswillnotverifytheconditionofthewasteline infrastructureunderthehome.Consultwithaqualifiedplumberforacamerainspectionofthesewer lateralsifthereisanyconcernastotheconditionofthewastelinesunderthehome. Allplumbingfixturesnotpermanentlyattachedtoahouseholdappliancewereoperatedandinspectedfor visibleleaks.Waterflowthroughoutthehomewasaverage.Waterpressureappearedtobeadequate. Pleasenotethatwaterpressureanddrainageoftenchangeandfluctuateovertime,andthebuyershould monitorpressuresafteroccupancy.Higherwaterpressuresmaycauseadvanceddeteriorationofsupply systemsandcomponents,prematurefailureoffaucetsandconnections,andleaks.Ifconcernedabout excessivewaterpressure,consultwithaprofessionalplumberregardingoptions,suchasinstallationor adjustmentofaregulatoratthemainwatershutofflocation. Thisreportisnotintendedtobeanexhaustivelistofminorplumbingissues.Concealed,latentor intermittentplumbingissuesmaynotbeapparentduringthetestingperiod. Determiningwhethersupplyanddrainagesystemsarepublicorprivate(city,well,septic,etc)isnotpartof ahomeinspection.Consultwiththeseller'sdisclosureandothersourcestohelpdeterminethat information. BATHROOMSANDMISCPLUMBING Bathroomswereinspectedusingvarioustechniquestohelpidentifyanyareasofleakageordamage. Pleasenotethatbathtubsandshowersaretestedwithouttheweightofapersonintheenclosure.We attempttoidentifyareasofpotentialleakage,butsomeproblemareasmaynotbevisiblewithoutthe weightofapersonintheenclosure,ie,apersontakingashowerorbath.Anylatentdeficienciesnoted undertheseconditionsoncethehomeisoccupiedshouldbesealedtopreventwaterintrusionand damage. Thedrainlineunderthekitchensinkleaksandshouldberepairedtopreventfurtherwaterintrusion.At Page19of30 MasterInspector:Bill Sample AddressofInspection:123 Sample Drive, Louisville, KY thetimeofrepair,alldrainlinesshouldbefurtherassessed. Photo20 Drainlineleaksunderthekitchensink. NOTE-thetoiletinthehallbathroomruns.Thismaybeduetoanimproperlyseatedflappervalveorsome othercomponentthatisnotproperlysealed.Exteriorleakagewasnotobservedatthetimeofthe inspection. WATERMETER Themainwatershutoffvalveforthehomewaslocatedadjacenttothewaterserviceentrypointabovethe waterheaterinthecloset.Watershutoffvalvesarevisuallyinspectedonly.Noattemptismadetooperate themainoranyotherwatersupplyshutoffvalvesduringtheinspection.Thesevalvesareinfrequently usedandcouldleakafterbeingoperated. Photo21 Mainwatershutoff. Page20of30 MasterInspector:Bill Sample AddressofInspection:123 Sample Drive, Louisville, KY WATERHEATER A50galloncapacity,naturalgaswaterheaterwaslocatedinthecloset.Thewaterheaterwas manufacturedbyA.O.Smith,modelnumberGCV50100andserialnumberB05A046455.Informationon thewaterheaterindicatedthatitwasmanufactured11yearsago.Hotwatertemperaturewas approximately95degreesF. Atemperatureandpressurereliefvalve(T&P)waspresent.Anoverflowlegwaspresent.Itdidterminate properly.YoursafetydependsonthepresenceofaT&Pvalveandproperterminationoftheoverflowleg. Thewaterheaterwasfunctional. NOTE-codeschangeforproperwaterheaterinstallation.Asareminder,wedonotinspectforcurrent codecompliancebutforsafety.Whenawaterheaterisreplacedbyalicensedtechnicianitisnecessary forhimtobringthesetupuptothethen-currentcode.Thismayincludealteringtheconfigurationofthe waterheater,includingflueconfiguration. Photo22 GENERALINTERIOR TheHomeTeaminspectsforevidenceofstructuralfailureandsafetyconcernsonly.Thecosmetic conditionofthepaint,wallcovering,carpeting,windowcoverings,etc.,arenotaddressed. Theonlywaytotellthepresenceandrelativeconcentrationofmoldistoperformavalidmoldtest.The presenceofcertainmoldsandmoldsporesinbuildingscanresultinmildtoseverehealtheffectsinpeople andcandeterioratethestructureofthebuildingresultinginstructuraldamage.HomeTeamrecommends thatallhomesbetestedformoldtodeterminethetypeofmoldpresentinthebuilding.Clientsareurgedto obtainfurtherinformationconcerningmoldandairqualityfromthefollowingandothersources: www.doh.wa.gov/ehp/ts/IAQ/Got-mold.htmlandwww.iaqcouncil.org Waterstainswerepresentontheceilingofthehome(garage,laundryroomandhallwaycloset).The stainsappearedtobedryatthetimeoftheinspectionandshouldbemonitoredforanyfuturemoisture. Page21of30 MasterInspector:Bill Sample AddressofInspection:123 Sample Drive, Louisville, KY Mold-likegrowthisvisibleinthestructure(garage).TheEPAhashelpfulinformationthatmayassist thebuyer(http://www.epa.gov/mold/moldresources.html).HomeTeamrecommendshavingtheareas testedtodeterminepresence,typeandrelativeconcentrationofmoldspores,andprofessionally remediatedbyareputablemoldremediationcompany,whichmayincluderemovingandreplacingaffected segments.Amoldremediationcompanymayuncoveradditionalareasorissuesrequiringrepairor remediation. Photo23 moldlikegrowthinthegarage SMOKEALARMSANDCODETECTORS Smokealarmswerepresentinthehouse. Carbonmonoxidedetectorswerenotpresentinthehouse. Propertymaintenancecodesvaryfromareatoarea.Somemunicipalitiesrequiresmokealarmsinevery bedroom,whileothersonlyrequirethemoneachfloor.Similarvariedrequirementsexistwithregardto carbonmonoxidedetectors.Checkwiththelocalcodeenforcementofficerfortherequirementsinyour area.Forsafetyreasons,thealarmsshouldbetesteduponoccupancy.Thebatteries(ifany)shouldbe replacedwithnewoneswhenyoumoveintothehouseandtestedonamonthlybasisthereafter. Thetestedsmokealarmdidnothavea10-yearlithiumbatteryinstalled.Theinspectedsmokealarmdid appeartobewiredintothehomes'electricalsystem.HomeTeamtestsarepresentativesmokealarmfor batterytype,wiring,andfunctionality. Atleastoneofthesmokealarmsismissingabattery.Priortooccupancy,ensureallsmokealarms haveappropriatelychargedandfunctioningbatteriesandaretestedforproperfunctionality. Someoftheroomsinthehomeweremissingsmokealarms.Operablesmokealarmsshouldbe installedintheappropriateplacespriortooccupancy. Page22of30 MasterInspector:Bill Sample AddressofInspection:123 Sample Drive, Louisville, KY WINDOWS,DOORS,WALLSANDCEILINGS Arepresentativenumberofaccessiblewindowsanddoorswereoperatedandfoundtobefunctional.The primarywindowswerevinyl-clad,singlehungstyle,withdoublepaneglass.Allexteriordoorswere operatedandfoundtobefunctional.Theexteriordoorlocksshouldbechangedorrekeyedupon occupancy.Possibleproblemareasmaynotbeidentifiedifthewindowsordoorshavebeenrecently painted. Exteriorwindowsrequireroutinecaulkingandmaintenancetopreventwaterintrusion. NOTE-thecondition,presence,orabsenceofscreens,stormwindowsanddoorsisoutsidethescopeof theinspection.Stormwindowsimproveenergyefficiency,assistinpreventingwaterintrusion,andslowthe deteriorationofsomewindowframes. Alightfixtureinthemasterbedroomislooseandshouldbesecured. Photo24 Looselightfixture. Abrokenbalusterlocatedonthestaircaseleadingtothesecondfloor,thebalustershouldbe replacedforsafety. Therearexteriordoorhasabrokendeadbolt.Afunctioningdeadboltshouldbeinstalledforappropriate functionofthedoor. Theinteriorwallandceilingsurfaceswerepredominantlyfinishedwithdrywall.Theinteriorwallandceiling structureconsistedofwoodframing.Possibleproblemareasmaynotbeidentifiediftheinteriorwalland ceilingsurfaceshavebeenrecentlypainted. Peelingpaintwasobservedonthewallsinthemasterbathroom.Thepeelingpaintdidappeartobe causedbywater(moisture).Therewasnoevidenceofanactiveleakatthetimeoftheinspection.Any damagedareasshouldbescraped,repaired,leveledandprimedpriortoapplyingafinishcoatofpaint. Unpaintedsurfacesarehighlysusceptibletowaterintrusionanddamage. Page23of30 MasterInspector:Bill Sample AddressofInspection:123 Sample Drive, Louisville, KY NOTE-Previousrepairsareevidentinthehome'sceiling(laundryroom).Thepresenceofrepairsdoesnot indicateanycurrentorongoingissue.However,HomeTeamisnotabletoseebehindareasofrepairand isunabletodetermineifthecauseofthepreviousdamagehasbeencorrected.Monitorandcorrectas needed. FIREPLACE Therewasonefireplaceinthehome.Ahomeinspectionofthefireplaceandchimneyislimitedtothe readilyvisibleportionsonly;perASHIstandardsofpractice,theflueisnotinspected.Forsafeandefficient operationwerecommendannualinspectionsbyaqualifiedfireplaceprofessional.Aqualifiedchimney sweepwillcleantheinteriorifnecessaryusingspecializedtools,testingprocedures,mirrors,andvideo camerasasneeded,toevaluatethefireplacesystem.Ifthefireplacehasnotbeencleanedandinspected byaqualifiedfireplaceprofessionalwithinthepastyearwerecommendthisservicepriortouse.The resultsofsuchaninspectionmayrevealneededorrecommendedrepairs. Thevisualconditionatthetimeoftheinspectionwasasfollows: Aventedfireplaceinsertwithnaturalgasfuelsupplywaslocatedinthefamilyroom.Thechimney/fluewas metalmaterial.Theunitwasoperatedandwasfunctional.Besuretoreadandunderstandtheoperating procedurespriortooperatingtheunit.Therewerenomajorvisualdefectsobservedonthegasfireplace.If thefireplaceisusedforburningwood,specialprecautionsshouldbetaken,includingafullassessmentby achimneysweepforsuitabilityandanyconfigurationchangesthatshouldoccur. Often,gasfireplacesthathavenotbeenoperatedforaprolongedtimerequireanextendednumberof attemptsbeforetheywilllight.Thisisoftenduetoairinthelinesthatrequirestimetopurge. KITCHEN Thevisibleportionsofthekitchencabinetsandcountertopswereinfaircondition.Theapplianceswere operatedtocheckbasicoperationalfunctiononly.Noconsiderationisgivenregardingtheageor componentsthatmaybewornorotherwiseaffectedbywearandtearoruse.Thekitchencontainedthe followingappliances: NOTE-kitchencabinetdoorhingesareinneedofadjustment.Theseadjustmentsareusuallyrelatively simpleandonlyrequirethetighteningofscrewsoralignmentofavariableadjustmenthinge. NOTE-kitchencabinetdoorsweremissingduringthetimeoftheinspection. Thedishwasherwastestedanddidappeartobefunctional. NOTE-Thedishwashercouldnotberanthroughafullcycleduetothedrainlinesleaking. Thedisposalwasinspectedanddidnotappeartobefunctional.Theefficiencyratingandchopping/ grindingabilityoftheunitisnotwithinthescopeoftheinspection. Thedisposalisnotoperable.Consultwithaqualifiedplumberforrepairorreplacement. Page24of30 MasterInspector:Bill Sample AddressofInspection:123 Sample Drive, Louisville, KY WASHERANDDRYERCONNECTIONS Thisnoteissuppliedforinformationalpurposesonly,asmanyclientswanttoknowthetypeofdryer connectionsavailabletothem.A240voltstyleoutletforanelectricclothesdryerwasinstalledinthe laundryarea.Forsafetyreasons,noattemptwasmadetoverifythattheelectricaloutletisproperlywired orthatpowerispresent.Consultwithaqualifiedcontractorifthedesiredtypeofconnectionisnot available. Adryerventwasinstalled. Adrainforawashingmachinewaspresent. HEATINGSYSTEM-NATURALGAS TheheatingsystemwasinspectedbyaqualifiedHomeTeamprofessional.Periodicpreventive maintenanceisrecommendedtokeepthisunitingoodworkingcondition.Annualmaintenanceofthe heatingandcoolingequipmentisessentialforsafeandefficientperformance,whichwillmaximizethe system'susefullife.Theresultsofourvisualandoperationalinspectionoftheheatingsystemare describedbelow: ThehomewasheatedbyaPaynenaturalgasforcedairfurnace,modelnumberPG8MAA042090,serial number4104A26848whichis12yearsold.Thetemperaturesplitwasmeasuredatseverallocationsand wasapproximately30degreesF,whichisnormal. Theunitwaslocatedintheatticofthehome.Theflueventappearedtobeconfiguredinsuchawayasto properlyventthefluegases. NOTE-codeschangeforproperfurnaceinstallation.Asareminder,thisisavisualandfunctionalcheckof thesystemonly.WheneverafurnaceisreplacedbyalicensedHVACtechnicianitisnecessaryforhimto bringthesetupuptothethen-currentcode.Thismayincludealteringthecurrentconfigurationofthe system.Thisisafunctionaltestonly;ifacompleteandexhaustivecheckoutofallofthecomponentsofthe HVACsystemisdesired,orifyourwarrantycompanyrequiresaspecificinspectionfromtheirapproved HVACvendorlist,contactareputableandlicensedHVACcompanypriortoclosing. Page25of30 MasterInspector:Bill Sample AddressofInspection:123 Sample Drive, Louisville, KY Photo25 Photo26 Becauseofitsconditionandperformanceatthetimeoftheinspection,thefurnacerequirescleaning andservicingbyaprofessionalHVACtechnician.Atthattime,thetechnicianwilltestrefrigerantlevels, servicetheequipmenttoimproveitsperformance,andperformothertestsbeyondthescopeofthehome inspectiontoassessandidentifyanyadditionalareasthatmayrequireattention. AIRCONDITIONING TheelectricoutdoorairconditionercondensingunitwasaPayne,ModelNumberPA10JA036CandSerial Number4104E13255.Theunitislocatedontheleftsideofthehome.Thisunitisapproximately12years old.Periodicpreventivemaintenanceisrecommendedtokeepthisunitingoodworkingcondition,and HomeTeamstronglyrecommendspartneringwithareputableHVACcompanyforroutinemaintenancefor theheatingandcoolingsystemsinthefallandspring.Theairconditioningsystemwastestedandfoundto befunctional.Asareminder,thisisfunctionalitytestandvisualinspectiononly;wedonotchecksuction pressures,contactoramps,orrefrigerantlevels.Ifamoredetailedinspectionisrequired,pleaseconsult withanHVACcompany. Page26of30 MasterInspector:Bill Sample AddressofInspection:123 Sample Drive, Louisville, KY Photo27 Thetemperaturesplitfortheairconditionerwasmeasuredatseverallocationsandwasapproximately10 degreesF,whichisnormal. Therewillbenormaltemperaturevariationsfromroomtoroomandleveltolevel,mostnoticeablebetween levels.Airflowthroughoutthehousemaybebalancedbyadjustinganydampersinthesupplyducts,orby adjustingthesupplyregisters.Inspectionofairandductsupplysystemforadequacy,efficiency,capacity oruniformityoftheconditionedairtothevariouspartsofthestructureisbeyondthescopeofthehome inspection. Theairfiltershouldbereplacedorcleaned,asappropriate,onaregularbasistomaintaintheefficiencyof thesystem. Theairfilterisextremelydirtyandshouldbereplaced.ProlongedoperationofanHVACsystemwitha dirtyfiltercancauseinternaldamagetothecompressorvalvesthatmaynotbeobservableduringthe homeinspection;operatingwithadirtyfiltermayalsodamagetheairhandler.HomeTeamrecommends havingtheHVACsystemcleanedandservicedforthisreason. PESTINSPECTION Thepurposeofapestinspectionistodetermineifthereareactivewooddestroyinginsects(WDI)present inthehomeandwhetheranydamagehasoccurredfromtheseinsects.Thepestinspectiondoesnot includedeterminingthepresenceofcommonhouseholdinsectssuchasspiders,ants,etc. ThepestinspectionwasperformedbyBlackDiamond.Theircompletedreportissentunderseparate cover Page27of30 MasterInspector:Bill Sample AddressofInspection:123 Sample Drive, Louisville, KY RADONTEST AradontestwasperformedaccordingtoEPAguidelinesandtestingprotocol.Thetestisascreening measurementtodeterminetheaverageradonconcentrationinthehomeduringthetestingperiod.The testwasaccomplishedwithaContinuousRadonMonitor(CRM),asophisticatedEPA-approvedtesting device. Radon,thesecondleadingcauseoflungcancer,isaradioactivegasthatcomesfromthenatural breakdownofuraniuminsoilandrockandgetsintotheairyoubreathe.Itmovesthroughthegroundand intoyourhomethroughcracksandotherholesinthefoundationwhereitcanaccumulatetounsafelevels. Becauseitisodorless,colorless,andtasteless,testingistheonlywaytoknowifyouandyourfamilyareat riskfromradon. Theradoninspectionreportwillfollowunderseparatecoveruponcompletionofthetestperiod.Radon levelsvaryovertimebasedonmanydifferentfactors,andtheaverageconcentrationforthehomewill change.HomeTeamrecommendsperformingperiodic,long-termradontestingoncethehomeis occupied. Theradontestwasnotcompleteatthetimeoftheinspection.Thetestmustrunforaminimumof48 hours.Theradontestresultswillbesentunderseparatecover. Page28of30 MasterInspector:Bill Sample AddressofInspection:123 Sample Drive, Louisville, KY REASONABLEEXPECTATIONSREGARDINGAPROFESSIONALHOMEINSPECTION: Theremaycomeatimewhenyoudiscoversomethingwrongwiththehouse,andyoumaybeupsetordisappointed withyourhomeinspection.Therearesomethingswe'dlikeyoutokeepinmind. Intermittentorconcealedproblems:Someproblemscanonlybediscoveredbylivinginahouse.Theycannotbe discoveredduringthefewhoursofahomeinspection.Forexample,someshowerstallsleakwhenpeopleareinthe shower,butdonotleakwhenyousimplyturnonthetap.Someroofsandbasementsonlyleakwhenspecific conditionsexist.Someproblemswillonlybediscoveredwhencarpetsarelifted,furnitureismovedorfinishesare removed. Noclues:Theseproblemsmayhaveexistedatthetimeoftheinspection,buttherewerenocluesastotheir existence.Ourinspectionsarebasedonthepastperformanceofthehouse.Iftherearenocluesofapastproblem, itisunfairtoassumeweshouldforeseeafutureproblem. Wealwaysmisssomeminorthings:Somesayweareinconsistentbecauseourreportsidentifysomeminor problemsbutnotothers.Theminorproblemsthatareidentifiedwerediscoveredwhilelookingformoresignificant problems.Wenotethemsimplyasacourtesy.Theintentoftheinspectionisnottofindthe$200problems;itisto findthe$1000problems.Thesearethethingsthataffectpeople'sdecisionstopurchase. Contractor'sadvice:Acommonsourceofdissatisfactionwithhomeinspectorscomesfromcommentsmadeby contractors.Contractors'opinionsoftendifferfromours.Don'tbesurprisedwhenthreeroofersallsaytheroofneeds replacement,whenwesaidthattheroofwouldlastafewmoreyearswithsomeminorrepairs. "Lastmanin"theory:Whileouradvicerepresentsthemostprudentthingtodo,manycontractorsarereluctantto undertaketheserepairs.Thisisbecauseofthe"lastmanin"theory.Thecontractorfearsthatifheisthelastperson toworkontheroof,hewillgetblamediftheroofleaks,regardlessofwhetherornottheroofleakishisfault. Consequently,hewon'twanttodoaminorrepairwithhighliability,whenhecouldre-rooftheentirehouseformore moneyandreducethelikelihoodofacallback.Thisisunderstandable. Mostrecentadviceisbest:Thereismoretothe"lastmanin"theory.Itsuggeststhatitishumannaturefor homeownerstobelievethelastbitofexpertadvicetheyreceive,evenifitiscontrarytopreviousadvice.Ashome inspectors,weunfortunatelyfindourselvesinthepositionof"firstmanin"andconsequentlyitisouradvicethatis oftendisbelieved. Whydidn'tweseeit?:Contractorsmaysay,"Ican'tbelieveyouhadthishouseinspected,andtheydidn'tfindthis problem." Thereareseveralreasonsfortheseapparentoversights: Conditionsduringinspection:Itisdifficultforhomeownerstorememberthecircumstancesinthehouseat thetimeoftheinspection.Homeownersseldomrememberthatitwassnowing,therewasstorageeverywhere orthatthefurnacecouldnotbeturnedonbecausetheairconditioningwasoperating,etc.It'simpossiblefor contractorstoknowwhatthecircumstanceswerewhentheinspectionwasperformed. Thiswisdomofhindsight:Whentheproblemmanifestsitself,itisveryeasytohave20/20hindsight. Anybodycansaythatthebasementiswetwhenthereis2"ofwateronthefloor.Predictingtheproblemisa differentstory. Alonglook;Ifwespenthalfanhourunderthekitchensinkor45minutesdisassemblingthefurnace,we'd findmoreproblems,too.Unfortunately,theinspectionwouldtakeseveraldaysandwouldcostconsiderably more. We'regeneralists:Wearegeneralists;wearenotspecialists.Theheatingcontractormayindeedhavemore heatingexpertisethanwedo.Thisisbecauseweareexpectedtohaveheatingexpertiseandplumbing expertise,structuralexpertise,electricalexpertise,etc. Page29of30 MasterInspector:Bill Sample AddressofInspection:123 Sample Drive, Louisville, KY Aninvasivelook:Problemsoftenbecomeapparentwhencarpetsorplasterareremoved,whenfixturesor cabinetsarepulledout,andsoon.Ahomeinspectionisavisualexamination.Wedon'tperforminvasiveor destructivetests. Notinsurance:Inconclusion,ahomeinspectionisdesignedtobetteryourodds.Itisnotdesignedtoeliminateall risk.Forthatreason,ahomeinspectionshouldnotbeconsideredaninsurancepolicy.Thepremiumthatan insurancecompanywouldhavetochargeforapolicywithnodeductible,nolimitandanindefinitepolicyperiod wouldbeconsiderablymorethanthefeewecharge.Itwouldalsonotincludethevalueaddedbytheinspection. ReprintedfromASHIReporter,ByPermissionofAlanCarson,CarsonDunlop&Assoc. Page30of30
© Copyright 2026 Paperzz