Boiler Manual GAS-FIRED BOILER M. BOILER PIPING DETAILS Piping Symbol Legend circulator (w/ isolation flanges) pressure reducing valve circulator w/ integral flow check) diff. pressure bypass gate valve globe valve anti-scald rated mixing valve ball valve pressure gauge swing-check valve flow-check valve spring-loaded check valve 4-way motorized mixing valve 3-way motorized mixing valve Munchkin heater hose bib / boiler drain pressure relief valve thermostatic radiator valve TRV (straight) thermostatic radiator valve TRV (angle) circuit setter backflow preventer float -type air vent union manual 3-way valve heat exchanger zone valve air separator vacuum breaker diaphragm-type expansion tank radiant manifold 21 Super Stor indirect DHW tank Boiler Manual GAS-FIRED BOILER Standard Munchkin boiler Preferred piping (zoning with valves) Space heating mode Drawing 2A zone valves make-up water P2 closely spaced tees differential pressure bypass valve purging valves V1 OFF anti-scald mixing valve cold water P1 T/P Munchkin boiler Super Stor indirect DHW tank NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. This drawing is meant to show system piping concept only. Installer is responsible for all equipment & detailing required by local codes. Adjust differential pressure bypass valve to eliminate any flow velocity noise when zone with highest pressure drop operates by itself. The minimum pipe size for connecting a Super Stor water heater is 1 inch. The minimum pipe size for connecting a Munchkin boiler is 1.25 inches and 2 inches for the 399M. All pumps are shown with isolation flanges. The alternative is standard flanges with full port ball valves. The anti-scald mixing valve is recommended if the DHW temperature is set above the factory setting of 119˚F. Install a minimum of 12 diameters of straight pipe upstream of all circulators. A purging valve may be used in lieu of the ball valve / hose bib combination shown. A minimum of 6 pipe diameters of straight pipe shall be installed upstream and downstream of all closely spaced tees. NOTE: For Vision piping applications, refer to the Vision Installation Piping Diagrams. 22 Boiler Manual GAS-FIRED BOILER Standard Munchkin boiler Preferred piping (zoning with valves) Domestic water heating mode Drawing 2B OFF OFF make-up water OFF OFF zone valves P2 closely spaced tees differential pressure bypass valve V1 purging valves anti-scald mixing valve cold water P1 T/P Munchkin boiler Super Stor indirect DHW tank NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. This drawing is meant to show system piping concept only. Installer is responsible for all equipment & detailing required by local codes. Adjust differential pressure bypass valve to eliminate any flow velocity noise when zone with highest pressure drop operates by itself. The minimum pipe size for connecting a Super Stor water heater is 1 inch. The minimum pipe size for connecting a Munchkin boiler is 1.25 inches and 2 inches for the 399M. All pumps are shown with isolation flanges. The alternative is standard flanges with full port ball valves. The anti-scald mixing valve is recommended if the DHW temperature is set above the factory setting of 119˚F. Install a minimum of 12 diameters of straight pipe upstream of all circulators. A purging valve may be used in lieu of the ball valve / hose bib combination shown. A minimum of 6 pipe diameters of straight pipe shall be installed upstream and downstream of all closely spaced tees. NOTE: For Vision piping applications, refer to the Vision Installation Piping Diagrams. 23 Boiler Manual GAS-FIRED BOILER Standard Munchkin boiler Preferred piping (zoning with circulators) Space heating mode Drawing 2C space heating zone circuit zone circulators make-up water closely spaced tees purging valves anti-scald mixing valve P2 cold water P1 T/P Munchkin boiler Super Stor indirect DHW tank NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. This drawing is meant to show system piping concept only. Installer is responsible for all equipment & detailing required by local codes. All closely spaced tees shall be within 4 pipe diameter center to center spacing. A minimum of 6 pipe diameters of straight pipe shall be installed upstream and downstream of all closely spaced tees. The minimum pipe size for connecting a Super Stor water heater is 1 inch. The minimum pipe size for connecting a Munchkin boiler shall be 1.25 inches and 2 inches for the 399M. All pumps are shown with isolation flanges. The alternative is standard flanges with full port ball valves. The anti-scald mixing valve is recommended if the DHW temperature is set above the factory setting of 119˚F. Install a minimum of 12 diameters of straight pipe upstream of all circulators. A purging valve may be used in lieu of the ball valve / hose bib combination shown. NOTE: For Vision piping applications, refer to the Vision Installation Piping Diagrams. 24 Boiler Manual GAS-FIRED BOILER Standard Munchkin boiler Preferred piping (zoning with circulators) Domestic water heating mode Drawing 2D space heating zone circuit zone circulators make-up water closely spaced tees purging valves anti-scald mixing valve P2 cold water P1 T/P Munchkin boiler Super Stor indirect DHW tank NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. This drawing is meant to show system piping concept only. Installer is responsible for all equipment & detailing required by local codes. All closely spaced tees shall be within 4 pipe diameter center to center spacing. A minimum of 6 pipe diameters of straight pipe shall be installed upstream and downstream of all closely spaced tees. The minimum pipe size for connecting a Super Stor water heater is 1 inch. The minimum pipe size for connecting a Munchkin boiler shall be 1.25 inches and 2 inches for the 399M. All pumps are shown with isolation flanges. The alternative is standard flanges with full port ball valves. The anti-scald mixing valve is recommended if the DHW temperature is set above the factory setting of 119˚F. Install a minimum of 12 diameters of straight pipe upstream of all circulators. A purging valve may be used in lieu of the ball valve / hose bib combination shown. NOTE: For Vision piping applications, refer to the Vision Installation Piping Diagrams. 25 Boiler Manual GAS-FIRED BOILER Standard Munchkin boiler Preferred piping (multiple boilers / zoning with circulators) Space heating mode Drawing 2E space heating zone circuit zone circulators make-up water closely spaced tees purging valves anti-scald mixing valve cold water P2 PB1 T/P PB2 T/P Munchkin boiler Munchkin boiler Super Stor indirect DHW tank NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. This drawing is meant to show system piping concept only. Installer is responsible for all equipment & detailing required by local codes. All closely spaced tees shall be within 4 pipe diameter center to center spacing. A minimum of 6 pipe diameters of straight pipe shall be installed upstream and downstream of all closely spaced tees. The minimum pipe size for connecting a Super Stor water heater is 1 inch. The minimum pipe size for connecting a Munchkin boiler shall be 1.25 inches and 2 inches for the 399M. All pumps are shown with isolation flanges. The alternative is standard flanges with full port ball valves. The anti-scald mixing valve is recommended if the DHW temperature is set above the factory setting of 119˚F. Install a minimum of 12 diameters of straight pipe upstream of all circulators. A purging valve may be used in lieu of the ball valve / hose bib combination shown. NOTE: For Vision piping applications, refer to the Vision Installation Piping Diagrams. 26 Boiler Manual GAS-FIRED BOILER Standard Munchkin boiler Preferred piping (multiple boilers / zoning with circulators) Domestic water heating mode Drawing 2F space heating zone circuit zone circulators make-up water closely spaced tees purging valves anti-scald mixing valve cold water P2 PB1 T/P PB2 T/P Munchkin boiler Munchkin boiler Super Stor indirect DHW tank NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. This drawing is meant to show system piping concept only. Installer is responsible for all equipment & detailing required by local codes. All closely spaced tees shall be within 4 pipe diameter center to center spacing. A minimum of 6 pipe diameters of straight pipe shall be installed upstream and downstream of all closely spaced tees. The minimum pipe size for connecting a Super Stor water heater is 1 inch. The minimum pipe size for connecting a Munchkin boiler shall be 1.25 inches and 2 inches for the 399M. All pumps are shown with isolation flanges. The alternative is standard flanges with full port ball valves. The anti-scald mixing valve is recommended if the DHW temperature is set above the factory setting of 119˚F. Install a minimum of 12 diameters of straight pipe upstream of all circulators. A purging valve may be used in lieu of the ball valve / hose bib combination shown. NOTE: For Vision piping applications, refer to the Vision Installation Piping Diagrams. 27 Boiler Manual GAS-FIRED BOILER D. BOILER PIPING DETAILS WITH THE VISION I SYSTEM Munchkin VISION 1 system (zoning with valves) Space heating mode Drawing 3A zone valves high limit safety make-up water purge purge differential pressure bypass valve anti-scald mixing valve cold water P1 DHW temperature sensor outdoor temperature sensor OFF T/P P2 purge Super Stor indirect DHW tank thermal trap (w/ drain plug) Munchkin boiler NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 29 This drawing is meant to show system piping concept only. Installer is responsible for all equipment & detailing required by local codes. All closely spaced tees shall be within 4 pipe diameter center to center spacing. A minimum of 6 pipe diameters of straight pipe shall be installed upstream and downstream of all closely spaced tees. The minimum pipe size for connecting a Super Stor water heater is 1 inch. The minimum pipe size for connecting a Munchkin boiler shall be 1.25 inches and 2 inches for the 399M. All pumps are shown with isolation flanges and integral flow check valves. The alternative is standard flanges with full port ball valves and a separate flow check valve. The anti-scald mixing valve is recommended if the DHW temperature is set above the factory setting of 119˚F. Install a minimum of 12 diameters of straight pipe upstream of all circulators. A purging valve may be used in lieu of the ball valve / hose bib combination shown. Adjust differential pressure bypass valve to eliminate any flow velocity noise when zone with highest pressure drop operates by itself. Boiler Manual GAS-FIRED BOILER Munchkin VISION 1 system (zoning with valves) Domestic water heating mode Drawing 3B zone valves high limit safety OFF make-up water purge purge differential pressure bypass valve anti-scald mixing valve cold water OFF DHW temperature sensor P1 outdoor temperature sensor T/P P2 purge Super Stor indirect DHW tank thermal trap (w/ drain plug) Munchkin boiler NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. This drawing is meant to show system piping concept only. Installer is responsible for all equipment & detailing required by local codes. All closely spaced tees shall be within 4 pipe diameter center to center spacing. A minimum of 6 pipe diameters of straight pipe shall be installed upstream and downstream of all closely spaced tees. The minimum pipe size for connecting a Super Stor water heater is 1 inch. The minimum pipe size for connecting a Munchkin boiler shall be 1.25 inches and 2 inches for the 399M. All pumps are shown with isolation flanges and integral flow check valves. The alternative is standard flanges with full port ball valves and a separate flow check valve. The anti-scald mixing valve is recommended if the DHW temperature is set above the factory setting of 119˚F. Install a minimum of 12 diameters of straight pipe upstream of all circulators. A purging valve may be used in lieu of the ball valve / hose bib combination shown. Adjust differential pressure bypass valve to eliminate any flow velocity noise when zone with highest pressure drop operates by itself. 30 Boiler Manual GAS-FIRED BOILER Munchkin VISION 1 system (zoning with valves) Space heating mode (w/ submixing) Drawing 3C 3-way (manually-set) mixing valve vent low temperature manifold station air handler high limit safety make-up water purge purge differential pressure bypass valve balancing valve anti-scald mixing valve cold water DHW temperature sensor P1 outdoor temperature sensor OFF T/P P2 purge Super Stor indirect DHW tank thermal trap (w/ drain plug) Munchkin boiler NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 31 This drawing is meant to show system piping concept only. Installer is responsible for all equipment & detailing required by local codes. All closely spaced tees shall be within 4 pipe diameter center to center spacing. A minimum of 6 pipe diameters of straight pipe shall be installed upstream and downstream of all closely spaced tees. The minimum pipe size for connecting a Super Stor water heater is 1 inch. The minimum pipe size for connecting a Munchkin boiler shall be 1.25 inches and 2 inches for the 399M. All pumps are shown with isolation flanges and integral flow check valves. The alternative is standard flanges with full port ball valves and a separate flow check valve. The anti-scald mixing valve is recommended if the DHW temperature is set above the factory setting of 119˚F. Install a minimum of 12 diameters of straight pipe upstream of all circulators. A purging valve may be used in lieu of the ball valve / hose bib combination shown. Adjust differential pressure bypass valve to eliminate any flow velocity noise when zone with highest pressure drop operates by itself. Adjust 3-way manually-set mixing valve to yield proper supply temperature to lower temperature load. Boiler Manual GAS-FIRED BOILER Munchkin VISION 1 system (zoning with circulators) Space heating mode Drawing 4A make-up water zone circulators high limit safety make-up water purge purge closely spaced tees anti-scald mixing valve cold water DHW temperature sensor P1 outdoor temperature sensor OFF T/P P2 purge Super Stor indirect DHW tank thermal trap (w/ drain plug) Munchkin boiler NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. This drawing is meant to show system piping concept only. Installer is responsible for all equipment & detailing required by local codes. All closely spaced tees shall be within 4 pipe diameter center to center spacing. A minimum of 6 pipe diameters of straight pipe shall be installed upstream and downstream of all closely spaced tees. The minimum pipe size for connecting a Super Stor water heater is 1 inch. The minimum pipe size for connecting a Munchkin boiler shall be 1.25 inches and 2 inches for the 399M. All pumps are shown with isolation flanges and integral flow check valves. The alternative is standard flanges with full port ball valves and a separate flow check valve. The anti-scald mixing valve is recommended if the DHW temperature is set above the factory setting of 119˚F. Install a minimum of 12 diameters of straight pipe upstream of all circulators. A purging valve may be used in lieu of the ball valve / hose bib combination shown. 32 Boiler Manual GAS-FIRED BOILER Munchkin VISION 1 system (zoning with circulators) Domestic water heating mode OFF OFF OFF Drawing 4B zone circulators high limit safety make-up water closely spaced tees purge purge anti-scald mixing valve cold water OFF DHW temperature sensor P1 outdoor temperature sensor T/P P2 purge Super Stor indirect DHW tank thermal trap (w/ drain plug) Munchkin boiler NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. 33 This drawing is meant to show system piping concept only. Installer is responsible for all equipment & detailing required by local codes. All closely spaced tees shall be within 4 pipe diameter center to center spacing. A minimum of 6 pipe diameters of straight pipe shall be installed upstream and downstream of all closely spaced tees. The minimum pipe size for connecting a Super Stor water heater is 1 inch. The minimum pipe size for connecting a Munchkin boiler shall be 1.25 inches and 2 inches for the 399M. All pumps are shown with isolation flanges and integral flow check valves. The alternative is standard flanges with full port ball valves and a separate flow check valve. The anti-scald mixing valve is recommended if the DHW temperature is set above the factory setting of 119˚F. Install a minimum of 12 diameters of straight pipe upstream of all circulators. A purging valve may be used in lieu of the ball valve / hose bib combination shown. Boiler Manual GAS-FIRED BOILER Munchkin VISION 1 system (zoning with circulators) Space heating mode (w/ submixing) Drawing 4C 3-way (manually-set) mixing valve vent air handler low temperature manifold station high limit safety make-up water balancing valve purge purge anti-scald mixing valve cold water DHW temperature sensor P1 outdoor temperature sensor OFF T/P P2 purge Super Stor indirect DHW tank thermal trap (w/ drain plug) Munchkin boiler NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. This drawing is meant to show system piping concept only. Installer is responsible for all equipment & detailing required by local codes. All closely spaced tees shall be within 4 pipe diameter center to center spacing. A minimum of 6 pipe diameters of straight pipe shall be installed upstream and downstream of all closely spaced tees. The minimum pipe size for connecting a Super Stor water heater is 1 inch. The minimum pipe size for connecting a Munchkin boiler shall be 1.25 inches and 2 inches for the 399M. All pumps are shown with isolation flanges and integral flow check valves. The alternative is standard flanges with full port ball valves and a separate flow check valve. The anti-scald mixing valve is recommended if the DHW temperature is set above the factory setting of 119˚F. Install a minimum of 12 diameters of straight pipe upstream of all circulators. A purging valve may be used in lieu of the ball valve / hose bib combination shown. Adjust 3-way manually-set mixing valve to yield proper supply temperature to lower temperature load. 34 Boiler Manual GAS-FIRED BOILER Munchkin VISION 1 system Drawing 4E (zoning with circulators) Space heating mode (3 fully reset supply temperatures) medium temperature manifold station vent air handler (higher temp.) vent high limit safety make-up water low temperature manifold station purge purge balancing valves 3-way (manually-set) mixing valve anti-scald mixing valve cold water P1 DHW temp. sensor outdoor temperature sensor OFF T/P P2 purge Super Stor indirect DHW tank thermal trap (w/ drain plug) Munchkin boiler NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 35 This drawing is meant to show system piping concept only. Installer is responsible for all equipment & detailing required by local codes. All closely spaced tees shall be within 4 pipe diameter center to center spacing. A minimum of 6 pipe diameters of straight pipe shall be installed upstream and downstream of all closely spaced tees. The minimum pipe size for connecting a Super Stor water heater is 1 inch. The minimum pipe size for connecting a Munchkin boiler shall be 1.25 inches and 2 inches for the 399M. All pumps are shown with isolation flanges and integral flow check valves. The alternative is standard flanges with full port ball valves and a separate flow check valve. The anti-scald mixing valve is recommended if the DHW temperature is set above the factory setting of 119˚F. Do not use valve actuators on manifolds supplied by manually-set 3-way mixing valves. A purging valve may be used in lieu of the ball valve / hose bib combination shown. Adjust 3-way manually-set mixing valve to yield proper supply temperature to lower temperature load. Boiler Manual GAS-FIRED BOILER Munchkin VISION 1 system Drawing 4F (zoning with circulators) Space heating mode (3 different supply temperatures) 3-way manually-set mixing valve vent air handler (higher temp.) vent low temperature manifold station high limit safety variable speed injection mixing make-up water purge purge balancing valves medium temperature manifold station anti-scald mixing valve cold water purge P1 DHW temp. sensor outdoor temperature sensor OFF T/P P2 purge Super Stor indirect DHW tank thermal trap (w/ drain plug) Munchkin boiler NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. This drawing is meant to show system piping concept only. Installer is responsible for all equipment & detailing required by local codes. All closely spaced tees shall be within 4 pipe diameter center to center spacing. A minimum of 6 pipe diameters of straight pipe shall be installed upstream and downstream of all closely spaced tees. The minimum pipe size for connecting a Super Stor water heater is 1 inch. The minimum pipe size for connecting a Munchkin boiler shall be 1.25 inches and 2 inches for the 399M. All pumps are shown with isolation flanges and integral flow check valves. The alternative is standard flanges with full port ball valves and a separate flow check valve. The anti-scald mixing valve is recommended if the DHW temperature is set above the factory setting of 119˚F. Follow all instructions for installation of injection mixing system. A purging valve may be used in lieu of the ball valve / hose bib combination shown. Adjust 3-way manually-set mixing valve to yield proper supply temperature to lower temperature load. 36 Boiler Manual GAS-FIRED BOILER Drawing 4G Munchkin VISION 1 system Multiple high temperature priority loads controlled with zone valves high temperature loads low temperature loads high limit safety air handler purge multi-zone relay center purge closely spaced tees anti-scald mixing valve OFF P1 outdoor temperature sensor T/P P2 purge differential pressure bypass valve Super Stor indirect DHW tank thermal trap (w/ drain plug) Munchkin heater NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 37 This drawing is meant to show system piping concept only. Installer is responsible for all equipment & detailing required by local codes. All closely spaced tees shall be within 4 pipe diameter center to center spacing. A minimum of 6 pipe diameters of straight pipe shall be installed upstream and downstream of all closely spaced tees. The minimum pipe size for connecting a Super Stor water heater is 1 inch. The minimum pipe size for connecting a Munchkin boiler shall be 1.25 inches and 2 inches for the 399M. All pumps are shown with isolation flanges and integral flow check valves. The alternative is standard flanges with full port ball valves and a separate flow check valve. The anti-scald mixing valve is recommended if the DHW temperature is set above the factory setting of 119˚F. Install a minimum of 12 diameters of straight pipe upstream of all circulators. A purging valve may be used in lieu of the ball valve / hose bib combination shown. High temperature loads cannot operate simultaneously with low temperature loads. Supply water temperature to high temperature loads is not reset based on outdoor temperature. Domestic water heating is highest priority load, and controlled through priority zone of multi-zone relay center OFF OFF make-up water OFF air handler zone circulators Boiler Manual GAS-FIRED BOILER Drawing 4H Munchkin VISION 1 system Multiple high temperature priority loads controlled with zone circulators Multiple low temperature load controls with zone circulators high temperature loads low temperature loads OFF make-up water OFF OFF air handler zone circulators high limit safety air handler purge multi-zone relay center purge closely spaced tees anti-scald mixing valve OFF P1 outdoor temperature sensor T/P P2 purge Super Stor indirect DHW tank thermal trap (w/ drain plug) Munchkin heater NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. This drawing is meant to show system piping concept only. Installer is responsible for all equipment & detailing required by local codes. All closely spaced tees shall be within 4 pipe diameter center to center spacing. A minimum of 6 pipe diameters of straight pipe shall be installed upstream and downstream of all closely spaced tees. The minimum pipe size for connecting a Super Stor water heater is 1 inch. The minimum pipe size for connecting a Munchkin boiler shall be 1.25 inches and 2 inches for the 399M. All pumps are shown with isolation flanges and integral flow check valves. The alternative is standard flanges with full port ball valves and a separate flow check valve. The anti-scald mixing valve is recommended if the DHW temperature is set above the factory setting of 119˚F. Install a minimum of 12 diameters of straight pipe upstream of all circulators. A purging valve may be used in lieu of the ball valve / hose bib combination shown. High temperature loads cannot operate simultaneously with low temperature loads. Supply water temperature to high temperature loads is not reset based on outdoor temperature. Domestic water heating is highest priority load, and controlled through priority zone of multi-zone relay center 38
© Copyright 2026 Paperzz