Why the LC-100 is the best choice for rig applications The LevelCom LC-100 is one of the most accurate, reliable and long lasting tank level indicators available, averaging over 18 years of service. The LC-100 is a microprocessor based pulsed bubbler that replaces submersible pressure transducers , floats and older style continuous flow machines. Local bar graph and digital display provide redundancy to monitoring console or HMI. NEW! Dual communication mode (ANALOG and MODBUS together) provides redundant data stream to BCS or VMS. (Profibus and Ethernet modules available) • Monitors without electronics in tank • Programmable Specific Gravity, works for all liquids, (water, fuel, brine, drill mud) • Eliminates replacement costs due to failed transducers and cables Ballast • Alarms — high-high to low-low Pre Load • 10 point tank configuration table for accurate volume & weight in irregular tanks • Automatic sensor zero • On board self diagnostics • Long service life, low maintenance Fuel / Lube Service Tanks Drill Mud Vessel Draft KEEP THE INTEGRITY OF RIG’S LEVEL MONITORING SYSTEMS INTACT ! Bring tanks back into service on station within hours. All electronics are above the tank eliminating the need for costly, time consuming tank cleaning, venting and certification. Maintenance and service are quicker, safer and more economical. Plug and Play. If replacement is ever necessary, new units will can be installed in minutes, quickly bringing the tank back online. Eliminates the need for manual soundings. Brine Corrosives www.levelcom.net LC-100 FEATURES LevelCom’s “Advanced Bubbler Technology” • Measures liquid levels without the need for a electronic sensor, cable or transducer in the tank • Built in Redundancy, Local display and dual communication mode, 4 -20mA with Modbus provides redundancy for VMS, BCS • Designed to monitor a single tank. If a fault occurs, it only impacts one single tank rather than a group of tanks • Low cost of ownership and system maintenance • Eliminates the most common failure points • Accurate and Dependable level readings Installation requires only a connection to air supply, electrical power source and bubbler tube. Only the stationary bubbler tube and the purge air come in contact with the liquid, making this system ideal for applications involving seawater, brine, hazardous, corrosive liquids and slurries. In normal mode the LC-100 automatically zeroes its sensor to atmosphere every 30 minutes. The bubbler tube is purged at regular intervals to keep the line clear. Self-diagnostics check the system for both pneumatic and electronic faults. If a problem is found, the LC-100 will display the appropriate error message or activate an alarm to alert the operator. All values and alarm set points are displayed in either English or Metric units of measure, (depth, volume or weight) on the digital display. For hazardous area installation, the LC-100 controls can be located up to 600 feet away from the tank or classed area. Lengths of pneumatic tubing isolate the hazardous area from the safe area. “All submersible transducers will fail, the issue is never if but when the failure will occur.” OPTIONS Depth Range — Ft. Meters 0—32 0-62 0-92 0-180 9.45 18.9 27.43 54.86 Modbus Profibus Modbus TCP/IP Dual Communication Communication RS 232 / 422 / 485 Alarm & Control Relays 4 programmable internal set points, Control 1 & 2, On / Off; 2 — SPDT Form C relays (“rated “Pilot Duty”) Analog Output 4 to 20 mA Automatic Specific Gravity Requires 2nd bubbler tube installation Differential Pressure Requires 2nd bubbler tube installation Digital Communication For Use with LC101 for Secondary Remote Readout Panel / Cabinet Fabrication Per customer specifications, complete with tubing, regulator and wiring SPECIFICATIONS Approvals ABS Type Approval , UL Listed, ISO 9001 certified manufacturer Power 120VAC / 100mA / Fuse — 2A; 24 VDC / 500mA / Fuse—2A Supply Air Regulated pressure varies with input sensor range (see below). Filtered to 40 microns Temperature Operating range: -20° F to +140° F (-28.88° C to +60° C) Enclosure UL listed NEMA 3R - Powder coated aluminum alloy with 304 stainless steel fasteners Fittings Material Brass or 316 Series Stainless Steel Dimensions 14.5” (37cm) H x 5.5” (14cm) W x 3.8” (9.6cm) D Alarm Set Points Four (4) programmable internal set points (Relay option required for remote alarm activation) Control Set Points Four (4) programmable set points (Control 1 & 2 On/Off) (Relay option required) Security User defined 1 - 9 character password protection Tank Sensing Range (H2O) 0 – 31 ft. (9.45m) 0 – 62 ft. (18.9m) 0 – 90 ft. (27.43m) 0 – 180 ft. (54.86m) Accuracy (Full Scale) +/-0.2% FS (+/-0.75”) +/-0.2% FS (+/-1.5”) +/-0.2% FS (+/-2.2”) +/-0.1% FS (+/-2.2”) Resolution (Full Scale) 0.1” (2.54mm) 0.2” (5.08mm) 0.3” (7.62mm) 0.1” (7.62mm) 20 – 35 psi 30 – 50 psi 45 – 60 psi 85 – 100 psi Supply Air Pressure THE LEVELCOM ADVANTAGE DIMENSIONS One Levelcom LC-100 replaces: • Pressure Transducer, Cable & Filter • Intrinsic Barrier/ Galvanic Isolator • Signal Amplifier • Panel Meter /Display Represented by: TMS is the leader in developing and refining pulsed bubbler technology for the past 18 years. LevelCom products have earned a reputation for being very accurate, dependable monitoring systems with long trouble free service life. A division of 6040 N. Cutter Circle Suite # 302 Portland, OR 97217 Phone: 503-285-8947 Fax: 503-285-1379 Email: [email protected] # LC100-10-2014
© Copyright 2025 Paperzz