JPR-THES Installation Instructions 1 GENERAL

JPR-THES Installation Instructions
1
GENERAL INFORMATION
Your THIN Suspension consists of a combination of Light Segments and Sleeves. It can be a single
Light Segment with one Power Sleeve and one End Sleeve at either end,
Or multiple Light Segments connected by Pass-Through Sleeves, with one Power Sleeve and one End
Sleeve at either end.
Installation Type
Description
Power Supply/Driver
LOCAL DRIVER
Driver is pre-installed in 6.5in dia
x 2.4in canopy, canopy mounts to
standard octagon fixture box.
Class 2 - 24VDC remote driver dimmable via compatible wall
switch, refer to driver specifications
pages 2-4, 8
Juniper recommends Lutron
DVCL-253P dimmers
REMOTE DRIVER WITH
JUNCTION BOX COVER
pages 2, 6-8
Separately located near fixture in
accessible location, connected via
low-voltage Class 2 wiring supplied
by electrician. 5in x 0.5in junction box
cover mounts to standard octagon
fixture box.
Class 2 - 24VDC remote driver dimmable via compatible wall
switch, refer to driver specifications
Juniper recommends Lutron
DVCL-253P dimmers
IMPORTANT:
TO PREVENT ELECTRIC SHOCK, ALWAYS DISCONNECT THE POWER BEFORE INSTALLING
FIXTURE AND BEFORE CLEANING OR OTHER MAINTENANCE
HARDWIRED FIXTURES SHOULD BE INSTALLED BY A LICENSED ELECTRICIAN - INSTALL
ACCORDING TO NATIONAL ELECTRIC CODE AND LOCAL REGULATIONS
CLASS 2 POWER SUPPLY REQUIRED
12.20.2016
[email protected]
+1 347 799-2915
68 33rd Street, Unit 11 Brooklyn, NY 11232
JPR-THES Installation Instructions
2
PART GLOSSARY
24 Inch Light Segment (a1)
36 Inch Light Segment (a2)
Power Sleeve (c1)
Pass-through Sleeve (c2)
End Sleeve (c3)
6.5 Inch Canopy (k1)
#8 Pan Head (d)
Mounting Post (b1)
with Cable Gripper (b2)
6.5 Inch Canopy Plate
with 24VDC Driver(k2)
1/8” IP Nut (i)
Wire Nuts (m)
Canopy Strain Relief (e)
5 Inch Canopy (j1)
Canopy Hole Cap (f)
5 Inch Canopy Plate (j2)
8-32 Countersunk (g)
8-32 Pan Head (h)
MOUNTING DIAGRAM
Mark the locations of the Mounting Posts (or Canopy, if is as serving as a mounting point) for your chosen Light
Segment length.
24 inches (609.6mm)
36 inches (914.4mm)
12.20.2016
[email protected]
+1 347 799-2915
68 33rd Street, Unit 11 Brooklyn, NY 11232
3
JPR-THES Installation Instructions
LOCAL DRIVER INSTALLATION
LOCAL DRIVER STEP 1
LOCAL DRIVER STEP 2
Fix the Mounting Posts (b1) to the ceiling using
Screws (d) and appropriate anchors, depending on
the installation location.
If using the canopy as a mounting point, thread the
power cable and aircraft cable through the canopy
cover (k1)(slip strain relief (e) over power cable
before inserting into canopy cover), and making
electrical and physical connections. Remove cable
gripper (b2) from extra provided mounting post (b1),
and fasten with provided nut (i) to canopy cover.
Attach canopy cover to mounting plate (k2) with
screws (h). Trim excess cable from grippers once
fixture has been leveled.
Note: top hole in the Mounting Posts can be used to
secure the cable along the ceiling.
b1
d
120VAC Line
b2
h
HOT
NEUTRAL
k2
m
i
24VDC Driver
LOCAL DRIVER STEP 2 ALT.
Red(+)
Black(-)
If not using the canopy as a mounting point,
plug both top canopy holes and use strain relief
(slip strain relief (e) over power cable before
inserting into canopy cover) for cord exit from
side hole. Attach canopy cover to mounting
plate.
b2
e
f
e
k1
f
CONTINUE TO PAGE 5
12.20.2016
[email protected]
+1 347 799-2915
68 33rd Street, Unit 11 Brooklyn, NY 11232
4
JPR-THES Installation Instructions
REMOTE DRIVER INSTALLATION
REMOTE DRIVER STEP 1
REMOTE DRIVER STEP 2
Fix the Mounting Posts (b1) to the ceiling using
either supplied Screws (d) and appropriate anchors,
depending on the installation location.
If using the canopy as a mounting point, thread the
power cable and aircraft cable through the canopy
cover (j1)(slip strain relief (e) over power cable
before inserting into canopy cover), and making
electrical and physical connections. Remove cable
gripper (b2) from extra provided mounting post (b1),
and fasten with provided nut (i) to canopy cover.
Attach canopy cover to mounting plate (j2) with
screws (g). Trim excess cable from grippers once
fixture has been leveled.
Note: top hole in the Mounting Posts can be used to
secure the cable along the ceiling.
b1
24VDC Supply from
Remote Driver
d
m
Red(+)
b2
g
Black(-)
j2
i
REMOTE DRIVER STEP 2 ALT.
If not using the canopy as a mounting point,
plug one canopy hole and use strain relief
(slip strain relief (e) over power cable before
inserting into canopy cover) for cord exit from
the other hole. Attach canopy cover to mouning
plate.
f
h
j1
b2
e
NOTE: POWER MUST
BE 24VDC CLASS 2,
DO NOT CONNECT TO
AC POWER/HOUSE
WIRING
CONTINUE TO PAGE 5
12.20.2016
[email protected]
+1 347 799-2915
68 33rd Street, Unit 11 Brooklyn, NY 11232
JPR-THES Installation Instructions
5
FINAL INSTALLATION
FINAL INSTALLATION STEP
Slide the Light Segment (c2 or c3, depending on number of length) into the Power Sleeve (c1) until magnetic
contaact is made. Repeat for additional Light Segments.
Note: you may gently rotate the Light Segment into the desired orientation (uplight or downlight)
a1 or a2
c1
12.20.2016
c2 or c3
[email protected]
+1 347 799-2915
68 33rd Street, Unit 11 Brooklyn, NY 11232