ME 437 – HW #6 Solutions Problem 6-1 15f6 = 14.973 – 14.984 Min Clearance = 0.016 15H7 = 15.000 – 15.018 Max clearance = 0.045 Problem 6-2 i. Sliding Fit H7/g6 ii. Locational interference fit H7/p6 iii. Locational interference fit H7/p6 iv. Close running fit H8/f7 v. Locational clearance fit H7/h6 vi. Locational clearance fit H7/h6 vii. Loose running fit H11/c11 Problem 6-3 FB= 15-0.05 = 14.95 Gage=14.95 Problem 6-5 For a free running fit: Pmin = 0.05 and Pmax = 0.136, therefore Pmin = Hmin – Fmax 0.05 = 12 – Fmax Fmax = 11.950 Pmax = Hmax – Fmin 0.136 = 12.013 - Fmin Fmin = 11.877 Shaft limits: 11.877 – 11.950 Problem 6-7 Problem 6-9 The primary application of metallic dowel pins is in jigs and fixtures Limits on Metric Dowel Pin Diameters are: 1.5mm to 3mm + .003 / +.008mm 4mm to 6mm + .004 / +.009mm (this corresponds to m5 limits) 8mm to 10mm + .006 / +.012mm (this corresponds to m5 limits) 12mm to 16mm + .007 / +.013mm 20mm to 25mm + .008 / +0.14mm Problem 6-10 Here is an example of 12 mm ground shafting. This shaft has 12h6 limits Problem 7-1