home inspection report Home. Safe. Home. Each office is independently owned and operated. | ©2013 The HomeTeam Inspection Service, Inc. All rights reserved. FileNumber:SAMPLEREPORT AddressofInspection:1234FifthStreet SAMPLEREPORT Throughoutthisreport,theterms"right"and"left"areusedtodescribethehomeasviewedfromthestreet. Theterm"majorvisualdefect"isdefinedintheHomeInspectionAgreement,thetermsofwhichare incorporatedintothisreport.TheHomeTeaminspectsforevidenceofstructuralfailureandsafetyconcerns only.Thecosmeticconditionofthepaint,wallcovering,carpeting,windowcoverings,etc.,arenotaddressed. Allconditionsarereportedastheyexistedatthetimeoftheinspection. Routinemaintenanceandsafetyitemsarenotwithinthescopeofthisinspectionunlesstheyotherwise constitutemajorvisualdefectsasdefinedintheHomeInspectionAgreement.Althoughsomemaintenance and/orsafetyitemsmaybedisclosed,thisreportdoesnotincludeallmaintenanceorsafetyitems,andshould notberelieduponforsuchitems. Theapproximatetemperatureatthetimeoftheinspectionwasapproximately87degreesFahrenheit,and theweatherwassunnyandclear.Theutilitieswereonatthetimeoftheinspection.Thebuyerwaspresent duringtheinspection.Thehomewasoccupiedatthetimeoftheinspection.Theageofthehome,as reportedbytheMLSsheet,wassaidtobe17yearsold. Thehomewassituatedonalevellot.Thegeneralgradearoundthehomeappearedtobeadequatetodirect rainwaterawayfromthefoundation. REVERSEGRADE:Areversegradeconditionexistsintherearofthehomeunderthebaywindow. Reversegradeisaconditionwherethegradeisloweratthefoundationthaninadjacentareas.This conditionwillcauserainwatertobedirectedtowardthefoundationwhichcan,overtimecause damagetothefoundationandstructure.Recommendthegradingbecorrectedsothatrainwateris directedawayfromthefoundation. Page3of16 FileNumber:SAMPLEREPORT AddressofInspection:1234FifthStreet Therewasaconcretedrivewayontherightsideofthehomewhichledtothegarage.Therewerenomajor visualdefectsobservedinthedriveway. Therewasaconcretewalkwayleadingtoaconcreteporchinthefrontofthehome.Therewerenomajor visualdefectsobservedinthewalkwayortheporch. Controljointsinwalkwayneedtobesealed. Therewasaconcretepatiolocatedinthebackofthehome.Therewerenomajorvisualdefectsobservedto thepatio. Thepationeedstobesealedwhereitmeetsthefoundation. Thestepsonthepatiotothehouseneedsahandrailforsafety. Page4of16 FileNumber:SAMPLEREPORT AddressofInspection:1234FifthStreet STRUCTURE&SIDING Theinspectedpropertyconsistedofatwostorywood-framedstructurewithBrickveneerandvinylsiding. Therewerenomajorvisualdefectsonthevisibleportionsofthesiding. Thedoortothepatiohaswoodrotontheframingaroundthebottomthatneedstoberepaired. TheareaofthesidingwheretheA/Clinesenterthehomeneedtobesealedtopreventwater intrusion. Page5of16 FileNumber:SAMPLEREPORT AddressofInspection:1234FifthStreet GARAGE Theattachedgaragewasdesignedforthreecarswithaccessprovidedbytwooverhead-styledoors.The concretegaragefloorwasingoodcondition.Therewerenomajorvisualdefectsobservedinthegarage structure. garageopener TheChamberlainandLiftmasterbrandelectricgaragedooropenersweretestedandfoundtobefunctional. Theautomaticsafetyreverseonthegaragedoorinneedofadjustment.Therewerenomajorvisualdefects observedinthedoormechanisms. ROOFSTRUCTURE Theroofwasagableandvalleydesigncoveredwithasphalt/fiberglassshingles.Observationoftheroof surfacesandflashingwasperformedfromthegroundlevelwiththeaidofbinoculars.Theageoftheroof covering,asreportedbytheseller,wasapproximately10+years.Thereweretwolayersofshinglesonthe roofatthetimeoftheinspection.Therewasminimalcurlingandlightsurfacewearobservedontheroof shinglesatthetimeoftheinspection.Theseconditionsindicatetheroofshingleswereinthesecondhalfof theirusefullife.Thisvisualroofinspectionisnotintendedasawarrantyoranestimateontheremaininglifeof theroof.Anyroofmetal,especiallytheflashingandvalleys,mustbekeptwellpaintedwithapaintspecially formulatedfortheuse.Therewerenomajorvisualdefectsdetectedontheexterioroftheroof. Theroofdrainagesystemconsistedofaluminumguttersanddownspoutswhichappearedtobefunctionalat thetimeoftheinspection.Guttersanddownspoutsshouldreceiveroutinemaintenancetopreventpremature failure.Therewerenomajorvisualdefectsobservedonthevisibleportionsoftheguttersordownspouts. Therewasonechimney.Observationofthechimneyexteriorwasmadefromgroundlevelwithbinoculars. Therewerenomajorvisualdefectsobservedontheexterior. Page6of16 FileNumber:SAMPLEREPORT AddressofInspection:1234FifthStreet ATTICSTRUCTURE Theatticwasaccessedthroughascuttleinthebedroomcloset.Theatticabovethelivingspacewas insulatedwithbattedandloose-fillinsulation,approximately12-inchesindepth.Ventilationthroughoutthe atticwasprovidedbygable,soffitandroofvents.Theroofstructureconsistedoftwo-inchbyfour-inchwood trussesspaced24inchesoncenterandOSB(waferboard)sheathing.Becauseoftheconfigurationofthe catwalkorlackthereof,whichlimitedaccess,itwasnotpossibletoinspectallareasoftheattic.Therewasno moisturevisibleintheatticspace.Theabsenceofvisibleindicationsofmoistureisnotnecessarilyconclusive evidencethattheroofisfreefromleaks.Theonlywaytobesurearoofdoesnotleakistoinspectthe undersideoftheroofduringaheavyrain.Therewerenomajorvisualdefectsobservedintheatticstructure. ELECTRICSERVICE Theundergroundelectricservicewireenteredthehomeontherearwall.Theelectricmeterwaslocatedon theexteriorwall. TheservicewireenteredaCutlerHammerservicepanel,locatedonthegaragewallwitha200ampand 120/240voltratedcapacity.Thebranchcircuitswithinthepanelwerecopper.Thesebranchcircuitsandthe circuitbreakerstowhichtheywereattachedappearedtobeappropriatelymatched. Page7of16 FileNumber:SAMPLEREPORT AddressofInspection:1234FifthStreet ThevisiblehousewiringconsistedprimarilyoftheRomextypeandappearedtobeingoodcondition. Arepresentativenumberofinstalledlightingfixtures,switches,andreceptacleslocatedthroughoutthehome wereinspectedandwerefoundtobefunctional.Thegroundingandpolarityofreceptacleswithinsixfeetof plumbingfixtures,andthoseattachedtogroundfaultcircuitinterrupters(GFCI),ifpresent,werealsotested. AllGFCIreceptaclesandGFCIcircuitbreakersshouldbetestedmonthly.TherewereGFCIprotectedcircuits locatedinthekitchenandbathroom(s).ThepresentandtestedGFCI'swerefunctional.Anon-functional GFCIshouldbereplacedwithfunctionalGFCI's. HOTNEUTRALREVERSE:Therewereonereceptacleinthesecondfloorhallwaybathroomwherethe presenceofhotandneutralwireswerereversed.Thisisasafetyconcernandshouldberepairedby alicensedelectrician. Thereceptaclerightofthelivingroomdoorislooseinthewallandneedstobeproperlysecuredfor safety. TheGFCIresetbuttoninthereceptaclerightofthekitchenstoveisbrokenandreceptacleneedsto bereplaced. Theelectricalserviceappearedtobeadequate.Alarms,electronickeypads,remotecontroldevices, landscapelighting,telephoneandtelevision,andallelectriccompanyequipmentwerebeyondthescopeof thisinspection.Therewerenomajorvisualdefectsobservedintheelectricalsystem. FOUNDATION Thefoundationwasconstructedofpouredconcrete.Asingleinspectioncannotdeterminewhethermovement ofafoundationhasceased.Anycracksshouldbemonitoredregularly.Therewerenomajorvisualdefects observedonthevisibleportionsofthefoundation. BASEMENT/LOWERLEVEL Thefullbasementwaspartiallyfinished,andcontainedthefollowingmechanicalsystems:furnace,water heaterandsumppump. Page8of16 FileNumber:SAMPLEREPORT AddressofInspection:1234FifthStreet FINISHEDBASEMENTWAIVER:Theinteriorwallsofthebasementwerefinished;therefore,acomplete inspectionofthepouredconcretefoundationwasnotpossible.Therewerenomajorvisualdefectsobserved onthevisibleportionsofthefoundation. Thebasementwasclutteredwithmanystoreditemsand/orshelvesatthetimeofinspection, thereforeseveralareaswereunabletobeinspected. FLOORSTRUCTURE ThevisiblefloorstructureconsistedofOSB(waferboard)subfloor,supportedbytwo-inchbyten-inchTJI joistsspacedsixteeninchesoncenter.Therewerenomajorvisualdefectsobservedinthevisibleportionsof thefloorstructure. PLUMBING Thevisiblewatersupplylinesthroughoutthehomewerecopperpipe.Thewaterwassuppliedbyapublic watersupply. ThevisiblewastelinesconsistedofPVCpipe.Thehomewasconnectedtoaseptictanksystem. Evaluationofthepresentconditionoftheentiresepticsystemwouldrequiretheservicesofaqualifiedseptic contractor.Thelocalhealthdepartmentmaybeabletoprovideadditionalinformationofthesepticsystem's previousinspections. Allplumbingfixturesnotpermanentlyattachedtoahouseholdappliancewereoperatedandinspectedfor visibleleaks.Waterflowthroughoutthehomewasaverage.Waterpressurewastestedhosebibandfoundto be40to50poundspersquareinch.Therewerenomajorvisualdefectsobservedinthevisibleportionsof theplumbingsystem. Thetoiletinthefirstfloorhalfbathroomislooseatthefloorandneedstobeproperlysecured. Recommendrepairbyaqualifiedcontractor., Thewatermeterwaslocatedinthefrontyard.Themainwatershutoffvalveforthehomewaslocated adjacenttothewaterserviceentrypointinthebasement. mainwatershutoff Page9of16 FileNumber:SAMPLEREPORT AddressofInspection:1234FifthStreet Thegasmeterwaslocatedontheexteriorwall.Althoughnoactualtestingwasperformedtodetectthe presenceofgasfumes,therewasnonoticeableodorofgasdetectedatthetimeoftheinspection. Therewasasumppumplocatedinthebasement.Thesumppumpwasfunctional.Therewasabattery backupsysteminthesumppit. WATERHEATER Therewasa50galloncapacity,naturalgaswaterheaterlocatedinthebasement.Thewaterheaterwas manufacturedbyRheem.SerialnumberRHLN0504500671.Informationonthewaterheaterindicatedthatitwas manufacturedapproximately 10yearsago. Atemperatureandpressurereliefvalve(T&P)waspresent.Becauseofthelimebuild-uptypicalofT&P valves,wedonottestthem.Anoverflowlegwaspresent.Itdidterminateclosetothefloor.Yoursafety dependsonthepresenceofaT&Pvalveandanoverflowlegterminatingclosetothefloor.Thewaterheater wasfunctional. Therewasalotofcorrosiononthecoldwatersupplylinetothewaterheater.Recommendfurther evaluationbyaqualifiedplumber. Page10of16 FileNumber:SAMPLEREPORT AddressofInspection:1234FifthStreet LIVINGAREA TheHomeTeaminspectsforevidenceofstructuralfailureandsafetyconcernsonly.Possibleproblemareas maynotbeidentifiediftheinteriorwallandceilingsurfaceshavebeenrecentlypainted.Theinteriorwalland ceilingsurfaceswerefinishedwithdrywall.Therewerenomajorvisualdefectsobservedintheinteriorwalls orceilings. Arepresentativenumberofaccessiblewindowsanddoorswereoperatedandfoundtobefunctional.Possible problemareasmaynotbeidentifiedifthewindowsordoorshavebeenrecentlypainted. Theprimarywindowswereconstructedofwood,doublehungstyle,withdoublepaneglass. Allexteriordoorswereoperatedandfoundtobefunctional.Theexteriordoorlocksshouldbechangedorrekeyeduponoccupancy. Therewerenomajordefectsobservedinthewindowsordoors. Therearrightbedroomwindowtopsashwouldnotstayintheopenpositionwithoutsupport.Thisconditionis usuallycausedbyadefectivebalancermechanism.Windowbalancerscanbearopeandweightinsidethe windowframeofolderwindows,oraspringandropesysteminnewerwindows.Repairorreplacementofthe balancersystemmayberequiredinorderforthewindowstostayopenwithoutadditionalsupport. Thegarageentrydoortothehomedoesnothaveselfclosinghingesandshouldhavetheminstalled forsafety. SMOKEALARMS:There weresmokealarmsfoundinthehouse.Forsafetyreasons,thesmokealarmsshouldbe testeduponoccupancy.Thebatteries(ifany)shouldbereplacedwithnewoneswhenyoumoveintothehouse,and testedonamonthlybasisthereafter. Thefirstlevelconsistedofanentry,livingroom,familyroom,breakfastnook,kitchen,laundry,diningroom andhalfbathroom.Thecosmeticconditionofthepaint,wallcovering,carpeting,windowcoverings,etc.are notaddressed.Therewerenomajorvisualdefectsobservedonthefirstlevel. Page11of16 FileNumber:SAMPLEREPORT AddressofInspection:1234FifthStreet SECONDLEVELThesecondlevelofthehomeconsistedoffourbedroomsandtwobathrooms.Therewere nomajorvisualdefectsobservedonthesecondlevel. FIREPLACE Thereweretwofireplacesinthehome.Thevisualconditionatthetimeoftheinspectionwasasfollows: Aventedgasfireplacewaslocatedinbasement.Theunitwasvisuallyinspectedanddidappeartobe functional.Manyoftheseunitsarecontrolledbyawallmountedswitch.Someoperatebyremotecontrol, whileothersarecontrolledfromthebaseoftheunit.Theseunitsusuallycomewithaninstructionplatethatis attachedtotheunitinsidethecontrolaccesspanel.Besuretoreadandunderstandtheoperatingprocedures priortooperatingtheunit.Therewerenomajorvisualdefectsobservedonthegasfireplace. Awoodburningfireplacewithamatchlightgaslogswaslocatedinthefamilyroom.Thedamperdidappear tobefunctional.Therewasnovisualevidenceofcreosotebuildupinthefireboxand/orchimney.Therewere nocracksobservedinthefireboxorvisibleportionsofthechimney. Aswithallelementsofthehomeinspection,thefireplaceinspectionisnottechnicallyexhaustive.The inspectionprovidesageneralconditionreportonly.Thefireplaceinspectiondoesnotincludetheinteriorof fluesorchimneys,draftcharacteristics,chimneyorfireboxintegrityortheadequacyofdraft,airflowor makeupair.Consultwithaqualified,reputablechimneyandfireplaceprofessionalforacompleteevaluation ofthefireplaceandchimney.Forsafetyreasons,afireplaceandthechimneyorpipetowhichitisvented shouldbecleanedandre-inspectedastheremaybehiddendefects,notfullyvisibleatthetimeofthe inspection.Thefireplacewasnottestedforoperationorfunction. KITCHENCABINETS&APPLIANCES Thelaminatecountertopsinthekitchenwereingoodcondition.Thekitchencabinetdoorsanddrawerswere inspectedandappeartobefunctional. TheGeneralElectricelectricfreestandingoven-rangecombinationwasinspectedanddidappeartobe functional.Theaccuracyoftheclock,timersandsettingsonovensarenotwithinthescopeofthisinspection. TheWhirlpoolrangehoodandmicrowavecombinationwasinspectedanddidappeartobefunctional.The exhaustcapacityisnotwithinthescopeofthisinspection.Cleaningthefanandfiltermayincreasethe exhaustcapability. TheFrigidairerefrigeratorwasinspectedanddidappeartobefunctional.Thetemperaturesettingandice maker,ifpresent,arenotwithinthescopeoftheinspection. TheKitchenAiddishwasherwasobservedthroughacompletecycleanddidappeartobefunctionalwhenset onthe"wash"and"drain"cycle. TheInsinkEratordisposalwasinspectedanddidappeartobefunctional.Theefficiencyratingisnotwithinthe scopeoftheinspection. Page12of16 FileNumber:SAMPLEREPORT AddressofInspection:1234FifthStreet HEATINGSYSTEM TheheatingsystemwasinspectedbyHomeTeam.Periodicpreventivemaintenanceisrecommendedtokeep thisunitingoodworkingcondition.Annualmaintenanceoftheheatingandcoolingequipmentisessentialfor safeandefficientperformance,whichwillmaximizethesystem'susefullife.Theresultsofourvisualand operationalinspectionoftheheatingsystemisdescribedbelow: ThehomewasheatedbyaGoodmannaturalgasforcedairfurnace,serialnumber0611638294,model numberGMH950904CXAVAwhichis8yearsold.Theunitwaslocatedinthebasementofthehome.Ithas anapproximatenetheatingcapacityof96,000BTUH. TheelectricoutdoorairconditionercondensingunitwasaGoodman,ModelNumberGSC140421ABand SerialNumber0702047626.Theunitislocatedinthebackofthehome.Thisunitisapproximately7years old.Periodicpreventivemaintenanceisrecommendedtokeepthisunitingoodworkingcondition.Theforced aircoolingsystemwastestedandfoundtobefunctional.Thehomeinspectiondoesnotincludeaheat-gain analysis,coolingdesignoradequacyevaluation,energyefficiencyassessment,installationcompliancecheck orrefrigerantevaluation. Page13of16 FileNumber:SAMPLEREPORT AddressofInspection:1234FifthStreet Therewillbenormaltemperaturevariationsfromroomtoroomandleveltolevel,mostnoticeablebetweenlevels. Airflowthroughoutthehousemaybebalancedbyadjustinganydampersinthesupplyducts,orbyadjustingthesupply registers.Inspectionofairandductsupplysystemforadequacy,efficiency,capacityoruniformityoftheconditionedair tothevariouspartsofthestructureisbeyondthescopeofthehomeinspection. Thedisposablefiltershouldbereplacedonaregularbasistomaintaintheefficiencyofthesystem.The efficiencyratingisnotwithinthescopeofthisinspection. Thecontrolfortheheatingandairconditioningsystemwasa24voltthermostatlocatedonthelivingroom wallofthehome.ThethermostatwasmanufacturedbyWhiteRodgersandwasfoundtobeinworkingorder. PESTINSPECTION ThepestinspectionwasperformedbyHomeTeam. Page14of16 FileNumber:SAMPLEREPORT AddressofInspection:1234FifthStreet SUMMARY Thepurposeofthissummaryistoprovidea"quickview"oftheresultsofthehomeinspection.Pleasebesure toreadthefullbodyoftheinspectionreport,asitcontainsmuchmoredetailaboutyournewhome.Any recommendationsforadditionalevaluationmustbeperformedpriortotheconclusionoftheinspection contingencyperiod.Thefollowingisasummaryoftheinspectionperformedat1234FifthStreet,HomeTown, OH67890: SafetyConcerns Thestepsonthepatiotothehouseneedsahandrailforsafety. Thegarageentrydoortothehomedoesnothaveselfclosinghingesandshouldhavethem installedforsafety. Exterior REVERSEGRADE:Areversegradeconditionexistsintherearofthehomeunderthebay window.Reversegradeisaconditionwherethegradeisloweratthefoundationthanin adjacentareas.Thisconditionwillcauserainwatertobedirectedtowardthefoundationwhich can,overtimecausedamagetothefoundationandstructure.Recommendthegradingbe correctedsothatrainwaterisdirectedawayfromthefoundation. TheareaofthesidingwheretheA/Clinesenterthehomeneedtobesealedtopreventwater intrusion. Thedoortothepatiohaswoodrotontheframingaroundthebottomthatneedstoberepaired. Electrical HOTNEUTRALREVERSE:Therewereonereceptacleinthesecondfloorhallwaybathroomwhere thepresenceofhotandneutralwireswerereversed.Thisisasafetyconcernandshouldbe repairedbyalicensedelectrician. TheGFCIresetbuttoninthereceptaclerightofthekitchenstoveisbrokenandreceptacle needstobereplaced. Electrical Thereceptaclerightofthelivingroomdoorislooseinthewallandneedstobeproperlysecured forsafety. Plumbing Thetoiletinthefirstfloorhalfbathroomislooseatthefloorandneedstobeproperlysecured. Recommendrepairbyaqualifiedcontractor., Therewasalotofcorrosiononthecoldwatersupplylinetothewaterheater.Recommend furtherevaluationbyaqualifiedplumber. Evaluationofthepresentconditionoftheentiresepticsystemwouldrequiretheservicesofaqualified septiccontractor.Thelocalhealthdepartmentmaybeabletoprovideadditionalinformationoftheseptic system'spreviousinspections. Exterior Controljointsinwalkwayneedtobesealed. Thepationeedstobesealedwhereitmeetsthefoundation. Page15of16 FileNumber:SAMPLEREPORT AddressofInspection:1234FifthStreet Interior FINISHEDBASEMENTWAIVER:Theinteriorwallsofthebasementwerefinished;therefore,acomplete inspectionofthepouredconcretefoundationwasnotpossible.Therewerenomajorvisualdefects observedonthevisibleportionsofthefoundation. Therearrightbedroomwindowtopsashwouldnotstayintheopenpositionwithoutsupport.This conditionisusuallycausedbyadefectivebalancermechanism.Windowbalancerscanbearopeand weightinsidethewindowframeofolderwindows,oraspringandropesysteminnewerwindows.Repair orreplacementofthebalancersystemmayberequiredinorderforthewindowstostayopenwithout additionalsupport. Thebasementwasclutteredwithmanystoreditemsand/orshelvesatthetimeofinspection, thereforeseveralareaswereunabletobeinspected. Page16of16
© Copyright 2026 Paperzz