Attachment B Ratings for Major Sites Investigated Site Specific Areas Rating Primary Issues 701 Ocean Street Roof, main building A Roof, fl eet building B Carports 1-10 B Some potential shading, roof was determined to be adequate for installation, though this should be confi rmed by a structural engineer. Roof was not examined and would need more detailed structural analysis, some potential shading Removal of trees and/or removal or relocation of light poles Emeline Campus Roof, 1400 building A&B Roof, 1080 building A&B Roof, 1060 building B The entire roof was not examined and would need more detailed structural analysis The entire roof was not examined and would need more detailed structural analysis Roof was not examined and would need more detailed structural analysis. Roof, 1040 building B Roof was not examined and would need more detailed structural analysis. Roof, 1020 building B Roof was not examined and would need more detailed structural analysis. Roof, warehouse building B Roof was not examined and would need more detailed structural analysis Roof, outbuilding B Roof was not examined and would need more detailed structural analysis. Roof, 415 Brookside B Roof was not examined and would need more detailed structural analysis. Carports 7, 13, 14 A Some potential evening shading, removal or relocation of light poles Carports 1-6, 9-12, 15-17 B Removal of trees and/or removal or relocation of light poles Carport 8 C Shading, telephone poles and light poles make this a problematic site Animal Shelter Roof, western section B Roof, eastern section B Roof, southeastern section B Carport, western section B Carport, central section A Roof was not examined and would need more detailed structural analysis. Some small roof obstacles. Roof was not examined and would need more detailed structural analysis. Some small roof obstacles. Roof was not examined and would need more detailed structural analysis. Potential evening shade from building, removal of trees and/or removal or relocation of light poles Removal of trees and/or removal or relocation of light poles Carport, eastern section A Removal of trees and/or removal or relocation of light poles Roof, western section B Roof was not examined and would need more detailed structural analysis. Roof, central section B Roof was not examined and would need more detailed structural analysis. Roof, eastern section B Roof was not examined and would need more detailed structural analysis. Carports 1-7 B Removal of trees and/or removal or relocation of light poles Roof, offices & fl eet area C Roof would need replacement to support solar panel weight. Roof, offices C Roof would need replacement to support solar panel weight. Roof, large vehicle parking C Roof would need replacement to support solar panel weight. Roof, outbuilding A Only viable rooftop on site. Roof, sign shop C Roof would need replacement to support solar panel weight. A&B Removal of trees and/or removal or relocation of light poles Si mpkins Swim Center Brommer Yard Carports 1-4 Rountree Detention Center Roof, outbuilding B Roof was not examined and would need more detailed structural analysis. Roof, "X" building (partial) B Roof was not examined and would need more detailed structural analysis. Due to the new planned construction, solar should be included for the roof at the design/build bid process. Roof, main building B Roof was not examined and would need more detailed structural analysis. Roof, jail area B Roof was not examined and would need more detailed structural analysis. Carports 1-2 B Removal of trees and/or removal or relocation of light poles Roof, Sciences building B Roof was not examined and would need more detailed structural analysis. Some roof obstacles. Roof, Investig. Building B Roof was not examined, however, a solar panels are already on this roof, but not functioning, which could reduce the size of the needed array. Roof, Admin. building B Carports 1-4 B Center for Public Safety Building was inadvertently left out of the investigation. Removal of trees and/or removal or relocation of light poles, carport 4 has the potential to add solar panels to existing structures in place. Ben Lomond Transfer Station Ground mounts 1-4 B Steepness of slopes will require soils and geotechnical assessments.
© Copyright 2026 Paperzz