Viento Area Light Instructions

VIENTO SITE AND AREA
LUMINAIRE
IMPORTANT SAFETY INSTRUCTIONS
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A
PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS
INVOLVED.
CE PRODUIT DOIT ÊTRE INSTALLÉ SELON LE CODE D’INSTALLATION PERTINENT, PAR UNE PERSONNE QUI
CONNAÎT BIEN LE PRODUIT ET SON FONCTIONNEMENT AINSI QUE LES RISQUES INHÉRENTS.
5. DO NOT MAKE OR ALTER ANY OPEN HOLES
IN AN ENCLOSURE OF WIRING OR
ELECTRICAL COMPONENTS DURING
INSTALLATION.
1. READ AND FOLLOW ALL SAFETY
INSTRUCTIONS.
2. DANGER-RISK OF FIRE OR ELECTRICAL
SHOCK-DISCONNECT POWER BEFORE
BEGINNING INSTALLATION.
DANGER RISQUE D'INCENDIE OU DE CHOC
ÉLECTRIQUE - déconnecter l'alimentation avant
COMMENCER L'INSTALLATION.
6. DO NOT EXPOSE WIRING TO EDGE OF SHEET
METAL OR OTHER SHARP OBJECTS IN ORDER
TO PREVENT WIRING DAMAGE OR ABRASION.
3. WARNING – RISK OF FIRE OR ELECTRICAL
SHOCK. INSTALL THIS KIT ONLY IN LUMINAIRES
THAT HAVE THE CONSTRUCTION FEATURES
AND DIMENSIONS SHOWN IN THE
PHOTOGRAPHS AND/OR DRAWINGS AND
WHERE THE INPUT RATING OF THE RETROFIT
KIT DOES NOT EXCEED THE INPUT RATING OF
THE LUMINAIRE.
AVERTISSEMENT - Risque d'incendie ou
d'électrocution. INSTALLER CE KIT dans des
luminaires qui ont les CARACTERISTIQUES DE
CONSTRUCTION ET DIMENSIONS le montrent
les photographies et / ou dessins ET Lorsque la
notation d'entrée de la trousse de réparation NE
DEPASSE PAS la capacité d'entrée du luminaire
4. INSTALLATION REQUIRES KNOWLEDGE OF
LED LIGHTING AND ELECTRICAL SYSTEMS.
RISK OF FIRE OR ELECTRICAL SHOCK EXISTS.
08/30/2016
MS4691
7. THE LED LUMINAIRE MUST BE WIRED IN
ACCORDANCE WITH THE NATIONAL
ELECTRICAL CODE AND APPLICABLE LOCAL
CODES.
8. PROPER GROUNDING IS REQUIRED FOR
SAFETY.
9. THIS LED LUMINAIRE MUST BE INSTALLED
PER THE APPLICABLE INSTALLATION CODE
BY A PERSON FAMILIAR WITH THE
CONSTRUCTION AND OPERATION OF THE
PRODUCT. DO NOT ATTEMPT INSTALLATION
IF THIS CONDITION IS NOT MET. CONTACT A
QUALIFIED ELECTRICIAN.
10. DO NOT USE THIS LUMINAIRE FOR ANYTHING
OTHER THAN ITS INTENDED USE.
11. REPLACE ONLY WITH XtraLight Manufacturing,
Ltd., Catalogue Number:
VNTLEDXXXXXXXXXXXXXXXXXXX
Page 1 of 4
VIENTO SITE AND AREA
LUMINAIRE
Specifications
Weight:
EPA:
IP Rating:
UL Rating:
Medium: 29 lbs.
Large: 39 lbs.
Medium: 1.1 sq. ft.
Large: 1.3 sq. ft.
IP66
Suitable for wet locations
Tools Required
9/16” socket wrench
Straight Blade screwdriver
Wiring Diagram
Supply – Line
Supply – Neutral
Supply – Ground
Fixture – Black
Fixture - White
Fixture - Green
Installation Instructions
Square Pole, Direct Arm Mount (included with fixture)
1.
2.
3.
4.
Machine pole for fixture. (See Figure 4)
Make sure power is off before wiring fixture.
Open fixture door by loosening (2) thumb screws. (See Figure 1)
Attach fixture to pole with hardware provided.
• (2) 3/8-16 x 2” Hex bolts
Thumb
• (2) 3/8” Flat washers
Screw
• (2) 3/8” Lock washers
• Nut plate
a. Thread top bolt with (1) lock washer and (1) flat washer
through arm gasket (included with fixture) and pole into top
nut in nut plate. (See Figures 2 & 3) Make sure bolt threads
fully through nut plate, but leave enough space outside pole
to hang fixture.
b. Insert keyhole slot in fixture over top bolt and slide down into
place, making sure both flat washer and lock washer are
inside the fixture.
c. Tighten top bolt hand tight.
d. Thread bottom bolt with (1) lock washer and (1) flat washer
through fixture, gasket, and pole into nut plate.
e. Push wires into pole.
f. Tighten both bolts to 25-30 ft.-lbs.
08/30/2016
MS4691
Arm
Gasket
Figure 1
Page 2 of 4
VIENTO SITE AND AREA
LUMINAIRE
5. Connect supply wires to fixture wires inside pole using liquid tight wire nuts (not provided). See wiring diagram
on previous page.
6. Close door, making sure that door gasket properly seats against housing.
7. Tighten (2) thumb screws sufficiently to ensure a water-tight seal.
8. Turn power on and ensure proper operation of fixture.
Figure 2
Figure 3
Optional Accessories (sold separately)
Round Pole Adaptor (VNT-RPA)
1. Rounded side is placed against pole
2. Arm gasket is placed between fixture arm and flat side of
adaptor.
3. Allows up to 4 Veinto fixtures to mount to a 3” dia. minimum
pole. (Compatible with a 3” to 5” dia. pole)
Adjustable Slip Fitter (VNT-ASF)
1. Arm gasket is placed between slip fitter and fixture.
2. Veinto may not be angled more than 40⁰ above
horizontal.
08/30/2016
MS4691
Page 3 of 4
VIENTO SITE AND AREA
LUMINAIRE
Figure 4
Pole drill pattern – Full size