FA N C O I L U N I T S SETTING EXCEPTIONAL NEW STANDARDS FALSE CEILING - 42EM ATMOSPHERA TM A WORLD OF NEEDS In order to satisfy the requirements of professional people Carrier offers a wide range of air conditioning solutions, for all application and system types. An in-depth market study precedes each solution in the Carrier range, followed by a technical review that is validated by a panel of installers and users. All Carrier products are Eurovent certified. Carrier is the world leader in air conditioning and considers the global impact of all functions for each proposed solution (chilled-water unit + fan coil + duct + diffusers + controls): ease-ofinstallation and use, environmental comfort, aesthetics, quality of the supplied air, energy savings. The expectations of each project participant are considered: investors, specifiers, installers, managers and users. The test laboratory is another unique Carrier feature: here we can simulate the environment and the individual requirements of each project and ensure that the proposed solution meets the expected results and is optimised as much as possible. The project designer saves time and enjoys complete peace-of-mind. CONCENTRATED PERFORMANCE MORE EFFICIENT FILTRATION Standard G3 type filters ensure highest indoor air quality. Optional higher efficiency filters are available to meet special requirements. ENHANCED THERMAL PERFORMANCE PERMANENTLY CONTROLLED AIR QUALITY - With a sloping coil* Carrier optimises and increases the heat exchange surface. This coil type has more pipes than a straight coil and this means higher efficiency. Carrier fan coil units are equipped with a CO2 detection sensor* and continuously analyse the air quality and control the fresh air intake, based on the occupancy level. This optimised control results in real energy savings. - A six-speed fan - three speeds pre-wired in the factory - allows precise matching of site requirements. * Coil 3 only * CO2 detection sensor optional TOTAL FLEXIBILITY FOR A SIMPLIFIED INSTALLATION To respond to the requirements and constraints of each site, Carrier now offers an extended range: IN-LINE CONFIGURATION • Compact version (version with optimised length from 810 mm) 810 mm MODULAR CONFIGURATION • Modular versions (S, U and I configuration) Duct connection flexibility 770 mm Side connection spigots possible (200 mm diameter) Configuration changeable on site 1050 mm AVAILABLE CONFIGURATIONS I S* U* *For modular configuration only INTELLIGENT CONTROL The Carrier fan coil units can be equipped with various controllers to suit all requirements and meet all expectations for air quality, comfort and planned profitability. From the simplest version (wall thermostat) to the most sophisticated design (connection to a communications bus), Carrier always offers the right solution. MODUBOOT: PERFORMANCE PLUS The Moduboot ceiling diffuser directs the air flow along the ceiling at high velocity, encouraging rapid mixing of supply air and ambient air. No “cold shower” effects and no air that is too warm for the occupants, just quiet and discreet integration into the ceiling design. Carrier thinks of every small detail to guarantee the well-being of your customers. The Moduboot ceiling diffuser can be matched to various installation configurations. MAXIMISED SOUND LEVEL REDUCTION Each element of the Carrier fan coils is designed for optimal acoustic results: - The fan has been generously sized to ensure the air volume is delivered with ease, ensuring low noise levels and offering long life. - Unit design and choice of insulation materials limit vibrations. A RANGE WITH OPTIMISED UNIFORM DIMENSIONS The Carrier fan coil concept facilitates installation and simplifies on-site operations. All product sizes have the same height (250 mm), and the compact design permits reduced ceiling void height. This uniform range design allows rationalisation of the work required on site, with fewer measurements - eliminating a potential error source. Captions: 35 mm gained (250 - 215 = 35) The condensate pan always has the same height, and condensate removal is ensured without loss of space. TECHNICAL DATA 42EM Nominal air flow at medium speed l/s Number of supply and return air spigots*** 1.0 2.0 2.1 2.2 2.3 3.0 3.1 3.2 3.3 120 140 150 195 264 140 150 195 264 2+2 3+3 3+3 3+3 3+3 3+3 3+3 3+3 3+3 Available static pressure at nominal air flow Pa 50 50 50 50 50 50 50 50 50 Total cooling capacity, chilled-water coil* kW 2.86 3.56 3.75 4.72 5.97 4.22 4.48 5.69 7.28 Sensible cooling capacity kW 2.17 2.64 2.81 3.56 4.65 2.95 3.14 3.99 5.23 Heating capacity, hot water coil** kW 2.43 3.28 3 3.6 4.46 2.88 3.04 3.74 4.75 Electric resistance heater Available capacity excluding fan heat (+5/-10%) W 500 1000 1000 2000 2000 1000 1000 2000 2000 Motor power input at 230 V W 119 110 128 182 229 110 128 182 229 Speed (LS/MS/HS) Discharge air sound power level (LS/MS/HS) Return air and radiated sound power level (LS/MS/HS) dB(A) dB(A) Unit dimensions H x L x D mm Operating weight kg Power supply (± 15%)**** V-ph-Hz V6/V2/V1 V6/V2/V1 V5/V2/V1 V6/V3/V1 V6/V3/V1 V6/V2/V1 V5/V2/V1 V6/V3/V1 V6/V3/V1 36/47/51 39/50/54 30/47/51 33/50/54 34/44/47 35/44/47 35/49/54 36/50/55 43/56/58 44/56/58 30/47/51 33/50/54 34/44/47 35/44/47 35/49/54 36/50/55 43/56/58 44/56/58 250x810x620 225x810x1020 33 47 250 x 810 x 1020 49 49 225 x 990 x 1020 49 68 250 x 990 x 1020 70 70 70 230-1-50 Carrier actively participates in the Eurovent certification programmes. Eurovent is an independent organisation that tests products and verifies the conformance between test results and data published by the manufacturer. Eurovent certification is an important guarantee for consultants and installers. They can be sure that a product with Eurovent certification will operate in conformance with the specifications and satisfy customer requirements. All indoor units come with Eurovent certification. Dixit JM - RCS Lyon B 353 000 870 - Printed in France T E C H N I C A L D AT A 4 2 E M * Based on: entering water temperature 7°C, air temperature 27°C db, 47% relative humidity, water temperature rise 5 K, nominal air flow and 50 Pa static pressure. ** Based on: entering water temperature 70°C, air temperature 20°C db, water temperature rise 10 K, nominal air flow and 50 Pa static pressure. *** In accordance with Eurovent conditions. **** Refer to the electrical data table in the Product Selection Data for more details. Order NO.: 14418-20-06/2005 Supersedes order NO.: New Manufacturer reserves the right to change any product specifications without notice A member of the United Technologies Corporation family
© Copyright 2026 Paperzz