Page 1 of 27 Effective from 01.07.2007 RDSO / SPN / TC / 049 / 2003 Ver 3.0 GOVERNMENT OF INDIA MINISTRY OF RAILWAYS DRAFT TECHNICAL SPECIFICATION For LEVEL CROSSING GATE CONTROL EQUIPMENT Using Wired / Wireless Data Communication with Private Number Exchange & Voice Logging Facilities SPECIFICATION No RDSO / SPN / TC / 049 / 2003 Version 3.0 Issued by Telecom Directorate RESEARCH DESIGNS & STANDARDS ORGANISATION LUCKNOW – 226 011 This specification is the property of RDSO. No reproduction shall be done without the permission from DG (Telecom)/ RDSO / Lucknow. Page 2 of 27 Effective from 01.07.2007 RDSO / SPN / TC / 049 / 2003 Ver 3.0 Document Data Sheet Specification Revision Title of Document DRAFT TECHNICAL SPECIFICATION For LEVEL CROSSING GATE CONTROL EQUIPMENT Using Wired / Wireless Data Communication with Private Number Exchange & Voice Logging Facilities Prepared By Shri M. K. Yadav Director / Tele / WL / RDSO Approved By Shri M. Alam Executive Director / Telecom / RDSO Abstract This document specifies technical specifications for LEVEL CROSSING GATE CONTROL EQUIPMENT Using Wired / Wireless Data Communication with Private Number Exchange & Voice Logging Facilities This specification is the property of RDSO. No reproduction shall be done without the permission from DG (Telecom)/ RDSO / Lucknow. Page 3 of 27 Effective from 01.07.2007 RDSO / SPN / TC / 049 / 2003 Ver 3.0 Document Control Sheet Serial Number Date of Amendment Amendment / Revision Reasons for Amendment 1 10 / 10 / 2003 First Draft Mission No 13: Improving safety at Level Crossings 2 12 / 05 / 2005 Second Draft 3 12 / 03 / 2007 Third Draft For implementation of suggestion given by Traffic & Track Directorate as well as feedback from field trial. i. To incorporate Voice Logging feature in the ASM Unit ii. Standardization of Connectors and Terminals iii. Power Supply input range COPY NUMBER ISSUED BY _________________ SIGNATURE ________________ DATE _________ ISSUED TO _____________________________________________________________ This specification is the property of RDSO. No reproduction shall be done without the permission from DG (Telecom)/ RDSO / Lucknow. Page 4 of 27 Effective from 01.07.2007 RDSO / SPN / TC / 049 / 2003 Ver 3.0 INDEX SECTION No. 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 REQUIREMENTS GENERAL GENERAL SYSTEM / TECHNICAL REQUIREMENT SYSTEM DIAGRAM SYSTEM FEATURE SYSTEM OPERATION SYSTEM SPECIFICATION ENVIORNMENTAL CONDITIONS WARRANTY TYPE APPROVAL INSPECTION SAMPLING REJECTION MARKING & PACKING ANNEXURE – A ANNEXURE – B PAGE No 6 7 11 13 17 19 22 22 22 24 25 25 25 26 27 This specification is the property of RDSO. No reproduction shall be done without the permission from DG (Telecom)/ RDSO / Lucknow. Page 5 of 27 Effective from 01.07.2007 RDSO / SPN / TC / 049 / 2003 Ver 3.0 ABBREVIATIONS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 dB DC AC DTMF Hz kHz MHz LED MOV PCB Rx Tx S/N Ratio AF SWR mW uW STN SM ASM LC VHF UHF EMI DGS&D DCPW TEC EUT SMF UL CSA Decibel Direct Current Alternate Current Dual Tone Multi Frequency Hertz Kilo Hertz Mega Hertz Light Emitting Diode Metal Oxide Varistor Printed Circuit Board Receive Transmit Signal to Noise Ratio Audio Frequency Standing Wave Ratio milli Watt micro Watt Station Station Master Assistant Station Master Level Crossing Very High Frequency Ultra High Frequency Electro-magnetic Interference Directorate General of Supplies & Disposals Directorate of Coordination, Police Wireless Telecommunication Engineering Center Equipment under Test Sealed Maintenance Free Underwriters Laboratories Canadian Standards Association This specification is the property of RDSO. No reproduction shall be done without the permission from DG (Telecom)/ RDSO / Lucknow. Page 6 of 27 Effective from 01.07.2007 1. GENERAL 1.0 INTRODUCTION: RDSO / SPN / TC / 049 / 2003 Ver 3.0 This document covers the technical requirements, system features, characteristics and provisions of tests and inspection of LEVEL CROSSING GATE CONTROL EQUIPMENT using wired and wireless Data Communication with Private Number exchange & Voice Logging facilities for use over Indian Railways and is issued under specification no. STT/SPN/TC/049/2003 1.1 This specification complies with the requirements of Railway Board’s Safety Circular No. 2000/ Safety (A&R) / 19 / 39 dated 08.05.2002 1.2 The specification is intended to cover the technical provision and does not include the provisions of a contract. 1.3 LOT: A lot is constituted by “Level Crossing Gate Control Equipment using Wired and Wireless Data Communication” of the same type manufactured in the same factory during the same period, using the same process and materials. This specification is the property of RDSO. No reproduction shall be done without the permission from DG (Telecom)/ RDSO / Lucknow. Page 7 of 27 Effective from 01.07.2007 RDSO / SPN / TC / 049 / 2003 2. GENERAL SYSTEM REQUIREMENT: 2.1 System Requirement Ver 3.0 The objective of the equipment is to establish reliable Communication between ASM and LC gates, which will control closing / opening of the gates before and after passing the train with recoding of data, voice & exchange of private number. 2.2 The ASM & LC Gate Control equipment should perform as follows:2.2.1 The system shall be designed in such a way that ASM shall be able to control at least 8 gates each on either side of the Station / Cabin from his ASM control equipment (in total 16 gates). However this can be increased or decreased depending upon the user’s requirement. 2.2.2 The message sent by ASM meant for a particular LC gate shall go to that gate only. 2.2.3 The message shall be initiated by pressing certain keys (push buttons) provided on the equipment. On operation of keys by ASM from his equipment, electronically recorded messages shall play in voice form in LC Gate Equipment and ASM should get its acknowledgment automatically and vice-versa. 2.2.4 The message shall be in Hindi, English or any regional language. Any two languages depending upon the requirement of the Railway can be selected while placing order to the RDSO approved manufacturer. 2.2.5 The System shall be compatible to work with all types of manned level crossing gates as defined in Para 4.20 2.2.6 The System shall follow the method of exchanging private number between ASM and LC gate man as per Railway board Safety circular No. 2000/Safety(A&R)/19/39 dated 08.05.2002 or latest. 2.2.7 ASM control equipment shall have keys like ADVISE, CLOSE, OPEN etc., so that ASM shall be able to give information to the Gate man by pressing appropriate keys. LCD panel provided on the equipment shall indicate the keys, pressed by ASM, private number inserted by ASM etc. SEND key must be there to send the information to the respective gates. LCD panel shall be of 16 Characters x 2 Lines 2.2.8 LC gate equipment shall have similar types of keys like CLOSE, PROBLEM, OPEN etc., so that LC gate man shall be able to send his request or information to the ASM. LCD panel provided on the equipment shall indicate the key pressed, private number inserted by LC gate man etc. LCD panel shall be of 16 Characters x 2 Lines 2.2.9 In case LC gate man is unable to execute the order of ASM for Closing the gate, he will immediately press the PROBLEM key with private number, which will intimate ASM about his inability. In Addition to that gateman should be able to promptly communicate with ASM with the help of Telephone provided with the equipment. 2.2.10 All the events like gate CLOSING, OPENING, PROBLEM, MESSAGES etc must be stored in the data-logger of ASM and LC gate Control Equipment with Date, Time, Train Number, Gate Number and Exchanged Private Number of ASM and gateman, which can be retrieved directly by connecting a DOT matrix printer to a port provided on either equipment. 2.2.11 ASM Control Equipment and LC gate equipment should be protected suitably by assigning password. Without correct password it shall not be possible to change the settings of parameters of the equipment. Settings of parameters mean programming of Gate ID, Controller (ASM) ID, Date, Time etc. Provision shall be made on the equipment itself for setting the parameters with the help of assigned keys by authorized Railway person. This specification is the property of RDSO. No reproduction shall be done without the permission from DG (Telecom)/ RDSO / Lucknow. Page 8 of 27 Effective from 01.07.2007 RDSO / SPN / TC / 049 / 2003 Ver 3.0 2.2.12 When stationmaster/ASM or LC gate man wishes to have voice communication, the same shall be possible by using telephone instrument provided on the equipment. Voice Communication should be recorded with Date & Time stamping on it. Voice Storage Device shall be part of ASM Control Equipment as described in para 4.22 2.2.13 The ASM Control equipment and LC Gate equipment shall be provided with mechanical Locking arrangement to prevent unauthorized operation of the System. However System Power shall remain in ‘ON’ condition to receive incoming messages and information. 2.2.14 Surge protection devices 2.2.14.1 Control line Protection : This device is to be connected before the equipment. The protection is to be provided in series with the control line. The device should be able to discharge a total surge current of 20 KA of 8/20 µs, DC breakdown voltage should be 300-400 Volts, and AC breakdown voltage at 50Hz should be 300-400 Volts. The arrester Rated voltage of the device should be > 18Volt. The protection level between core-core/ core-gnd should be <25V/<450V The device should be pluggable with a make before break feature. The device should be isolated from the ground with a G.D. tube. The device should be as per the IEC 61643-21 or in compliance with UL specification. 2.2.14.2 Power line protection Power line protection is to be provided at the power supply Input. The device should be connected in parallel to the supply. Class C type Stage II protection should be connected.The arrestor should be connected as per TT system of the wiring. The device should be pluggable & should have the potential free contact for remote monitoring of the health status of the device. The device should be able to handle a surge current of 20 KA of 8/20 µs. The device should be tested as per the IEC 61643-1. The connection scheme is provided in the Annexure-B 2.2.15 Lightning Arrestor for Antenna: The provision of lightning arrestor for stacked dipole omni-directional antenna shall be made to protect the radio set from lightning or EMI. The protection system as described shall be earthed with the equipment earth. The earth value shall be less than 5 ohm. 2.2.16 An External arrangement will have to be made for light so that the keyboard and LCD Panel can be seen during night, where there is no provision of electricity at the GATE LODGE / GOOMTI. The LED / Bulb of 12V DC/15- 35 mA current consumption along with ON/OFF switch shall be provided for illumination and the same shall be connected with the battery and shall be used only in the night at the time of use of LC Gate equipment. 2.2.17 The cabinet of the equipment shall be powder coated with light colour like Off-white, Grey etc 2.3 System should consist of following 2.3.15 Communication Link between ASM control and LC Gate equipment. The system shall be capable of working both on wired (2-wire overhead line or underground 4 Quad PET cable) or wireless (25 watts VHF radio set). When system is working on physical line, the Radio set shall be in hot standby mode so that in case of any failure of Physical Line, the system should automatically switch over to wireless This specification is the property of RDSO. No reproduction shall be done without the permission from DG (Telecom)/ RDSO / Lucknow. Page 9 of 27 Effective from 01.07.2007 RDSO / SPN / TC / 049 / 2003 Ver 3.0 communication with an indication on LCD panel as well as glow of RED LED provided on the equipment. 2.3.16 ASM Control Equipment: The system must be designed using 16-bit or higher data bus micro-controller of reputed make like Hitachi, Philips, Motorola etc and shall consist of following items 2.3.2.1 DGS&D/DCPW approved, MIL Grade 810C/D/E complaint, 25 W VHF radio set 2.3.2.2 DGS&D/DCPW approved Omni Directional Stacked Dipole antenna having SWR less than 1.5 2.3.2.3 DGS&D/DCPW approved RG 217 coaxial cable 2.3.2.4 DGS&D/DCPW approved Wireless Power Supply (12 V/10 amps) of reputed make like AXIOM etc. 2.3.2.5 DGS&D/DCPW approved Wireless Battery (12V, 65 AH) of reputed make like EXIDE, S/F, Hitachi, Amar Raja etc 2.3.2.6 DGS&D/DCPW approved Solar panel (70 Watt, 19.2 V nominal) of reputed make like Tata BP, CEL etc. 2.3.2.7 Telephone Instruments TEC/ CACT approved. 2.3.2.8 80 column DOT matrix printer of reputed make like EPSON. WIPRO, TVS etc. (OPTIONAL) This specification is the property of RDSO. No reproduction shall be done without the permission from DG (Telecom)/ RDSO / Lucknow. Page 10 of 27 Effective from 01.07.2007 RDSO / SPN / TC / 049 / 2003 Ver 3.0 2.3.17 LC Gate Equipment: The system shall be designed using 16-bit micro-controller of Reputed make like Hitachi, Philips, Motorola etc and shall consists of following items: 2.3.17.1 DGS&D/DCPW approved, MIL Grade 810C/D/E complaint, 25 W VHF radio. 2.3.17.2 DGS&D/DCPW approved Omni Directional Stacked Dipole antenna SWR less than 1.5 2.3.17.3 DGS&D/DCPW approved RG 217 coaxial cable 2.3.17.4 DGS&D/DCPW approved Wireless Power Supply (12 V/10 amps) of Reputed make like AXIOM etc. 2.3.17.5 DGS&D/DCPW approved Wireless Battery (12V, 65 AH) of reputed make like EXIDE, S/F, Hitachi, Amar Raja etc 2.3.17.6 DGS&D/DCPW approved Solar panel (70 Watt, 19.2 V nominal) of reputed make like Tata BP, CEL etc. 2.3.17.7 Telephone Instrument TEC /CACT approved This specification is the property of RDSO. No reproduction shall be done without the permission from DG (Telecom)/ RDSO / Lucknow. Page 11 of 27 3. Effective from 01.07.2007 RDSO / SPN / TC / 049 / 2003 Ver 3.0 SYSTEM DIAGRAM Railway Station/Cabin LC Gate 2 Wire Medium ASM Control Equipment LC Gate Equipment LCD Panel RADIO 16 x 2 line LCD Panel RADIO 16 x 2 line ADVISE 1 2 3 SEND CLOSE 1 2 3 SEND CLOSE 4 5 6 CONFIG PROB 4 5 6 CONFIG OPEN 7 8 9 PRINT OPEN 7 8 9 <- 0 -> <- 0 -> MSG ACK MSG SM key PRINT ACK Gateman key Power Supply 230VAC,50HZ-i/p Power Supply 230vAC,50 Hz-i/p 12V DC,10 A- o/p 12 V DC, 10 A- o/p Battrery 12 V , 65 AH Battery 12 V, 65 AH Solar panel 70 W Solar Panel 70 w Figure 3.1 This specification is the property of RDSO. No reproduction shall be done without the permission from DG (Telecom)/ RDSO / Lucknow. Page 12 of 27 Effective from 01.07.2007 RDSO / SPN / TC / 049 / 2003 Ver 3.0 2 – Wire Physical Line DN Gate No 8 . . . . . . DN Gate No 1 ASM Control Equipment UP Gate No 1 . . . . . . UP Gate No 8 Figure 3.2 Network Of LC GATE Control Equipment Using Wired / Wireless Data Communication This specification is the property of RDSO. No reproduction shall be done without the permission from DG (Telecom)/ RDSO / Lucknow. Page 13 of 27 Effective from 01.07.2007 RDSO / SPN / TC / 049 / 2003 Ver 3.0 4. SYSTEM FEATURES 4.1 The system shall be designed using micro-controller with a data and voice storage and retrieval facilities. It shall meet all the technical requirements as described in Para 2.0 4.2 ASM shall have facility to instruct the gateman for Opening or closing of the gate with scheme of exchanging private number as per Railway board directives for different types of manned level crossing gates. Selected train number, gate number, private number shall be visible on LCD panel of ASM control unit before SEND button is pressed by ASM. 4.3 At the selected LC gate the message in the local language for expected arrival time of train, its number and direction with private number shall be communicated and remain in repeat mode. Acknowledgment of commencement of playing of message on LC gate equipment should be provided on ASM control unit by automatic glow of ACK LED 4.4 Gate man shall inform the Opening of LC Gate to the ASM by pressing OPEN Switch. Local voice message for requesting to open gate shall be repeated at ASM control unit. 4.5 ASM control unit shall have capability to instruct the gate man to OPEN the gate. Voice message of opening the gate should be played through speaker in the LC gate unit. 4.6 Similarly ASM control unit shall have capability to instruct the gate man not to open the gate. Voice message shall be played through speaker in the LC gate unit advising not to open the gate. 4.7 Inability for closing the gate for any unforeseen reason can also be informed by the gate man to the ASM by pressing PROBLEM button with private number. Local voice message of LC gate problem with private number shall be played through speaker in the ASM control unit. In addition to that, Gateman shall immediately talk to ASM / SM on duty by using Telephone provided on the equipment. Whenever voice communication takes place, it will be recorded in Voice Storage Device of ASM Control Equipment with Date and Time stamping on it. 4.8 Priority of Emergency Call over On-going Call Whenever ASM is having communication with any of the Gatemen, then another Gateman shall not be able to listen the ongoing conversation. However if any other gate man shall have an urgent message to be conveyed to the ASM, then he shall be able to send the message to the ASM by pressing PROBLEM Button with private No. The same shall be displayed on the LCD of ASM Unit with RED LED indication. The emergency message also be played / reproduced on the ASM unit. In that case ASM shall promptly attend the emergency call by terminating the On-Going Voice Communication 4.9 Announcement of voice message shall continue in the ASM control unit, unless and until ‘ACK’ button of ASM control unit is pressed by ASM/SM on duty. 4.10 Announcement of voice message shall continue in the LC gate unit, unless and until ‘ACK’ button of LC gate unit is pressed by Gateman on duty. 4.11 Voice communication shall be possible through telephone between ASM and gateman. Voice communication shall be duplex when system is working on 2-wire Physical Line. Similarly voice communication shall be semi duplex/ simplex when system is working through wireless on VHF radio set. All Voice Communication shall be recorded in Voice Storage Device of ASM Control Equipment. 4.12 (Optional): The system software can be modified to have communication between one gateman to another gateman depending upon the requirement with the intervention of ASM/SM on duty. However ASM / SM on duty will have overriding facility to send messages to the gates even if he is engaged with Telephone communication. 4.13 The ASM Control Equipment and LC Gate equipment shall be provided with mechanical locking arrangement to prevent unauthorized operation of the System. However System Power will remain in ‘ON’ condition to receive incoming messages and information. In that case it is not possible to operate the equipment, even receipt of on-going voice messages cannot be stopped. This specification is the property of RDSO. No reproduction shall be done without the permission from DG (Telecom)/ RDSO / Lucknow. Page 14 of 27 Effective from 01.07.2007 RDSO / SPN / TC / 049 / 2003 Ver 3.0 4.14 On either side, there may be a number of level crossing gates which are required to be CLOSED / OPENED, there shall be a facility of “Group Messaging” to all the gates to facilitate quick transfer of same information to all the gates on either side depending on the requirement (Upside or Downside). However information received from the LC Gate shall be in serial mode and same shall be recorded with time and date. 4.15 It shall be possible to know the Gate status (CLOSED or OPENED) by using the potential free input contact available in the gate equipment. This facility can be used to relay the Gate closure / open condition by using suitable signaling arrangement as per rule. 4.16 Some limited solution shall be made for train details where train number is of alpha-numeric like goods train, Saloon, Railway engine, Trolley etc. The same shall be informed by the manufacturer to the Railway user. 4.17 Normally voice as well as data communication between ASM Control unit and LC gate unit will be through 2-wire physical media. Incase of LINE failure, alternate wireless medium shall work. There shall be dynamic switching to select first available working medium. 4.18 ‘LINE’ or ‘RADIO’ indication shall appear on ASM control unit as well as LC gate unit so that advise to the maintenance staff shall be made without delay in case of LINE failure. 4.19 System must have a provision to operate from any of the two available sources of power supply i.e. Electricity and battery. However Solar Panel must be another source to charge the battery and this shall not be part of the equipment. 4.20 System shall have facility to exchange Private Number for different type of gates as described in Railway board safety circular no 2000/safety(A&R)/19/39 whose description is as given below. 4.20.1 Traffic level crossing gate, interlocked with stop signals of station, provided with telephone, with normal position ‘ Open to road traffic’ Gate closing instruction with private number, from ASM to Gateman Gateman gives private number to ASM as acknowledgement. 4.20.2 Traffic level crossing gate, Non - interlocked with stop signals, provided with telephone, with normal position ‘ Closed to road traffic’. Gate open request, from gateman to ASM. Gate open instruction with private number, from ASM to gateman. Gate close information with private number, from gate-man to ASM. Confirmation of Gate closure from ASM as acknowledgement to gate man with private number. 4.20.3 Engineering Level crossing gate, Non-interlocked , provided telephone, with normal position ‘Open to road Traffic’ Train arrival information from ASM to gateman with Private number. Gateman acknowledges ASM with private number. Gate closing instruction from ASM to gateman with private number. Gateman acknowledges ASM with private number. Gate open instruction from ASM to gateman with private number. with 4.20.4 Engineering level crossing gate, Non interlocked , provided with telephone, with normal position ‘ Closed to road Traffic’ Gate open permission from gateman to ASM. Gate open instruction from ASM to gateman with private number. Gate close information with private number, from gateman to ASM. Confirmation of gate closure from ASM as acknowledgement to gateman with private number 4.20.5 Engineering level crossing gate, interlocked with gate signals, provided with telephone, with normal position ‘Open to road traffic’ Gate closing instruction with private number, from ASM to Gateman. Gateman gives private number to ASM as acknowledgement. This specification is the property of RDSO. No reproduction shall be done without the permission from DG (Telecom)/ RDSO / Lucknow. Page 15 of 27 4.21 Effective from 01.07.2007 RDSO / SPN / TC / 049 / 2003 Ver 3.0 Data logger: 4.21.1 The system shall have Data Logger to record all the events automatically with Date, Time, Train Number, Direction, Gate Number and exchanged Private Number between ASM and LC gateman, which can be retrieved by connecting it to a DOT Matrix printer. The provision of simultaneous data logging shall be made in both ASM and LC Control Equipment. 4.21.2 ASM Control equipment and LC gate equipment shall have facility to record all the events related to their operation including event of Voice communication. 4.21.3 Data Storage Capacity: ASM Control equipment and LC gate equipment shall have facility to store a minimum one-lakh events as explained in Clause no 4.21.1. 4.21.4 The data shall be stored in the FLASH EEPROM memory so that the stored events can not be erased in case of power failure or fluctuations. 4.21.5 When the Flash EEPROM memory will be full with the logged data , then ‘FIRST IN ‘ information will be ‘FIRST OUT’ from the memory i.e. The system will follow FIFO architecture. 4.21.6 Printout format of retrieved data shall be as follows ========================================================= ========================================================= Sl No DATE TIME MODE FROM GATE PVTN ACTIVITY ========================================================= ========================================================= 000 16/08/2003 11:33 LINE GATE 23 -- GATE OPEN REQUEST 001 16/08/2003 11:34 LINE STN 23 56 CLOSE FOR 5698 UP TRAIN 002 16/08/2003 11:41 LINE GATE 23 45 EXCHANGE FOR ASM PVT NO. 003 16/08/2003 11:42 LINE GATE 23 -- 004 16/08/2003 11:44 LINE STN 23 47 CLOSE FOR 5698 DN TRAIN 005 16/08/2003 12:10 LINE GATE 23 45 EXCHANGE FOR ASM PVT NO 006 17/08/2003 14:54 RADIO GATE 25 -- GATE OPEN REQUEST 007 17/08/2003 14:55 RADIO STN 25 56 OPEN GATE 008 17/08/2003 14:55 LINE STN 23 -- DON'T OPEN GATE VOICE CALL ========================================================= ========================================================= This specification is the property of RDSO. No reproduction shall be done without the permission from DG (Telecom)/ RDSO / Lucknow. Page 16 of 27 4.22 Effective from 01.07.2007 RDSO / SPN / TC / 049 / 2003 Ver 3.0 Voice Logging: 4.22.1 The system should be designed in such a way that it should have built-in arrangement to process, record and store any ongoing voice communication from ASM Unit to LC Gate Units and Vice Versa 4.22.2 The recording and storage of voice communication should start as soon as call is established between ASM Unit and LC Gate Units and the same should be terminated with the replacement of handset of the telephone instrument provided with LC Gate and ASM Units. The recorded voice data shall be stored with date and time stamping 4.22.3 The storage of voice data should be arranged in FIFO architecture and in no way it should get corrupted once it is stored 4.22.4 The voice communication file storage device should have provision of its removal in case of emergency but it has to be interfaced in such a way that removal should not be possible by an unauthorized or unwanted person 4.22.5 There shall not be any compression of the input voice signal to retain the originality of the recorded voice communication. The storage device recording capacity shall be 70 Hrs minimum 4.22.6 Retrieval of Voice Communication Data: There shall be an Ethernet interface port through which stored voice data can be transferred from ASM Unit to any PC / Laptop for listening and taking backup on CD / DVD media. If required, voice can be retrieved, played and listened through the speaker provided in the ASM Unit by simple operation using keyboard of the unit. Facility shall also be available for selection of any voice/ data for playing by entering desired date and time for specified duration. 4.22.7 In case of any problem in voice recoding, there shall be visual alarm to draw the attention of the ASM on duty, the same shall keep on glowing till such time acknowledged by the ASM. 4.22.8 The distortion of the recorded voice input signal when reproduced through speaker shall not be more than 5% w. r. t. original input signal This specification is the property of RDSO. No reproduction shall be done without the permission from DG (Telecom)/ RDSO / Lucknow. Page 17 of 27 5.0 Effective from 01.07.2007 RDSO / SPN / TC / 049 / 2003 Ver 3.0 SYSTEM OPERATION: The system shall have capability to search automatically the available medium of communication, that is 2 - wire and wireless. Preference of working shall be given to 2-wire. Incase 2 - wire is defective or not available, system will automatically select wireless as medium of communication. The system shall be capable to work either on 2-wire physical line or Wireless or on both mediums. 5.1 ASM Control Equipment 5.1.1 On Pressing "ADVISE" button, the word "ADVISE” will be displayed on the LCD panel. Thereafter the Gate Number (GATE:--), Private number(PVTN:--), Expected Time(ET:--),Direction of arrival train(UPDN:--) and Train number (TRN:---) can be inserted by keyboard and sent the information to the respective gate by pressing SEND button. 5.1.2 On Pressing "CLOSE" button, the word "CLOSE” will be displayed on the LCD panel. Thereafter the Gate Number(GATE:--), Private number(PVTN:--), Direction of arrival train(UPDN:--) and Train number (TRN:---) can be inserted by keyboard and sent the information to the respective gate by pressing SEND button. 5.1.3 On Pressing "OPEN" button, the word “OPEN” will be displayed on the LCD panel. Thereafter the Gate number(GATE:--), Private number(PVTN:--) can be inserted by keyboard and sent the information to the respective gate by pressing SEND button. 5.1.4 Whenever ASM control equipment sends the information by pressing SEND button, ‘ACK’ LED will glow. After confirm reception of the message at appropriate gate, ‘ACK’ LED will go-off. 5.1.5 After closing the gate, gate man shall press CLOSE button and enter the private No and press the SEND Button to transfer the information from LC Gate Equipment to ASM Control Equipment The received message will be displayed on LCD panel as well as playing of Voice message on speaker. In addition to that, ‘CLOSE’ LED will glow on ASM control Equipment. 5.1.6 In case of nay problem with the LC Gate or any untoward incident, the Gateman shall send the information to the ASM by pressing PROBLEM button from his equipment with Private Number. ASM control equipment will get visual indication on LCD Panel, Voice message on speaker with a Glow of ‘PROBLEM’ Red LED 5.1.7 On receipt of ‘Gate Opening’ request from Gateman, on ASM control equipment there will be Voice message as well as Glow of ‘OPEN’ LED. 5.1.8 Incase of 2-w physical line fault, the message will automatically transmitted through Wireless with an indication ‘RADIO MODE’ glow of LED as well as Display on LCD Panel. 5.1.9 ‘PTT’ LED shall glow incase of Voice Communication through Telephone on Wireless between ASM and LC Gate man. The PTT( Press to Talk ) switch and LED shall be energized with VOX ( Voice Operated Switch ) 5.1.10 This equipment shall have built-in Voice Logging facility as described in para 4.22. This specification is the property of RDSO. No reproduction shall be done without the permission from DG (Telecom)/ RDSO / Lucknow. Page 18 of 27 5.2 Effective from 01.07.2007 Ver 3.0 LC Gate Equipment 5.2.1 5.2.2 5.2.3 5.2.4 5.2.5 5.2.6 5.2.7 5.2.8 5.2.9 5.3 RDSO / SPN / TC / 049 / 2003 On pressing ‘CLOSE’ button the word ‘GATE CLOSE’ will appear in the LCD panel Thereafter by inserting Private No, the message can be sent to ASM Control Equipment by pressing ‘SEND’ button. On Pressing ‘PROB’ button the word ‘GATE PROBLEM’ will appear in the LCD panel Thereafter by inserting Private No, the message can be sent to ASM Control Equipment by pressing ‘SEND’ button. On pressing ‘OPEN’ button the word ‘GATE OPEN’ shall appear in the LCD panel and message can be sent to the ASM control equipment by pressing ‘SEND’ button. When the LC Gate equipment receives any message from ASM control equipment, voice message will play in the LC gate equipment. On pressing ‘ACK’ button the voice message can be muted. Whenever LC gate equipment sends the information by pressing SEND button, ‘ACK’ LED will glow. After confirm reception of the message at ASM Control Equipment, ‘ACK’ LED will glow OFF. On receipt of ‘Gate Open Message’ from ASM control equipment, there will be voice message on the speaker with an indication of ‘OPEN’ LED. On receipt of ‘Gate Close Message’ from ASM control equipment, there will be playing of voice message on a speaker with a glow off ‘CLOSE’ LED Incase 2-wire physical line fault, the message will be automatically transmitted through wireless with an indication of ‘RADIO MODE’ LED glow as well as display on LCD panel. ‘PTT’ LED shall glow in case of voice communication through telephone on wireless between LC gate man and ASM. The PTT ( Press to Talk) LED and switch shall be energized with VOX (Voice Operated Switch). Print-out: 5.3.1 All the events recorded by the Data-logger as explained in Para 4.21 can be downloaded / printed by connecting Dot Matrix Printer on the assigned port of the ASM Control equipment and LC Gate equipment by pressing ‘PRINT’ button and entering the date. 5.3.2. Provision shall be made to take printout from LC gate equipment. 5.3.3. ASM on duty can take print out on daily basis as per his requirement or as defined by the user of the equipment. This specification is the property of RDSO. No reproduction shall be done without the permission from DG (Telecom)/ RDSO / Lucknow. Page 19 of 27 Effective from 01.07.2007 RDSO / SPN / TC / 049 / 2003 Ver 3.0 6.0 SYSTEM SPECIFICATION: 6.1 Electrical Parameters For ASM Control Equipment and LC Gate Equipment 6.1.1 Power Supply 6.1.2 Current Consumption SMPS Power plant with battery charger Input: 165 V to 260 V AC, 50Hz Output: 12 V DC +/- 10 %, 10 Amp 6 Amp max. on wireless 800mA max. on 2–wire physical line 6.1.3 Event Logging i Number of Data events ii Real Time Clock iii Print-out iv Voice Data Storage Capacity Min 1 lac Year, Month, Date, Hour and Minute By connecting a DOT Matrix printer Min 70 Hours 6.1.4 6.1.5 6.1.6 6.1.7 3 Watts Two digits 16 x 2 alphanumeric, with back-lit LED. Min one year Speaker Output Level Gate Identification number LCD display RTC Battery backup 6.2 6.2.1 25 Watt Radio: VHF radio set of 25 watt for wireless communication shall be procured from DGS&D approved source. The radio shall be MIL Grade, 810C/D/E compliant. 6.2.2 Spec of the radio Sl No Parameters Characteristics A. A1. A2. A3. A4. A5. A6. A7. A8. GENERAL Frequency Range Channel Spacing Emission Frequency Spread Frequency Stability Type of Operation Operating Temperature Range Speaker Impedance 146 to 174 MHz 12.5 kHz or 25 kHz 8K50F3E or 16KOF3E 28 MHz 5 PPM Simplex / Semi - duplex, Press to talk -300 C to 550 C 8 B. B1. B2. B3. B4. B5. B6. B7. TRANSMITTER RF Power Output Frequency Deviation Modulation Sensitivity Modulation distortion Modulation fidelity Spurious and Harmonics Output Impedance 10 to 25 Watt +/- 5 kHz (W type), +/- 2.5 kHz (N type) 80mV for 60% max. deviation at 1000Hz. Better than 5% Within +1, -3 dB of 6 dB / Octave -36 dBm (.25uW) 50 C. C1. C2. C3. C4. C5. RECEIVER Sensitivity Selectivity Image and Spurious rejection AF distortion Audio output C6. C7. Squelch Sensitivity AF Response 0.3v / -118 dbm at 12 dB SINAD Better than 60 dB Better than 65 dB Better than 5% Better than 250 mw with less than 5% distortion at 1 kHz ref. measured at specified AF output. Better than –119 dbm Within +1 , -3 dB of 6 dB / Octave This specification is the property of RDSO. No reproduction shall be done without the permission from DG (Telecom)/ RDSO / Lucknow. Page 20 of 27 Effective from 01.07.2007 RDSO / SPN / TC / 049 / 2003 6.3 Specs of Telephone Instrument 6.4 Specs of Stacked Dipole Omni Directional Antenna Sl No Ver 3.0 CACT approved Parameters A A01 A02 A03 A04 A06 A08 A09 ELECTRICAL SPECIFICATIONS Frequency Range – MHz Bandwidth – MHz Impedance – Ohms VSWR – less than RF Power handling capacity – Watt Termination Lightening Protection B B01 B02 B03 B04 B05 B06 B07 B08 B11 MECHANICAL SPECIFICATIONS Support Pipe Material Support Pipe Length – feet Support Pipe O D – mm Support Pipe Wall Thickness – mm Radiating Elements Material Radiating Elements Material O D – mm Radiating Elements Mounting Clamp Mounting Clamp for Antenna Shipping Length - Feet Characteristics 146 - 174 10 50 unbalanced 1.5 100 N – female Direct Ground Aluminum 12 50 2.5 Aluminum 12 Cast Iron / Aluminum Cast Iron / Aluminum 6.5 6.5 Specs of Antenna Cable Sl No Parameters A1 Length A2 Size A3 Jacket A4 Outer Diameter A5 Characteristic Impedance A6 Average Power Rating A7 Attenuation Characteristics As per site requirement RG 217 Low Loss Cable Polyethylene Black 14 mm 50 + / - 1 ohm 1.00 kW at 100 MHz 0.05 dB / Mt at 100 MHz 6.6 Specs of 12 Volts Battery (SMF battery) Sl No Parameters A1 Voltage A2 Backup Capacity A3 Can work with Radio A4 Maintenance Characteristics 12 V Min 65 AH 25 W Free Maintenance This specification is the property of RDSO. No reproduction shall be done without the permission from DG (Telecom)/ RDSO / Lucknow. Page 21 of 27 Effective from 01.07.2007 RDSO / SPN / TC / 049 / 2003 6.7 Specs of Solar Panel Sl No Parameters A1 A2 A3 A4 A6 Current at Pm Solar Panel Open Circuit Voltage Voltage at Pm Charging Type Short Circuit Current Ver 3.0 Characteristics Max 1.17 Amps to 2.5 Amp 19.2 V max Max 17 Volt Constant Current & Constant Voltage 1.34 Amps 6.8 Terminals / Connectors: 6.8.2 D Link or similar make RJ11 & RJ45 connectors shall be used to connect the 2W telephone sets / lines / PC to eliminate any inadvertent disconnection of the input / output lines. 6.8.3 All other connectors like antenna, power and solar panel shall be lockable so that it can not get disconnected inadvertently 6.8.1 It is necessary to terminate the 2W / 4W input lines through screw terminals / connectors to achieve lowest contact resistance & to avoid possibility of corrosion due to different climatic conditions, all metallic parts of the connectors / terminals should be non ferrous. The terminals & connectors should have locking arrangement so that input lines to the equipment should not get disconnected inadvertently. Terminals / Connectors to be used shall be in compliance with DIN VDE 0627, 993 – 05 and UL / CSA similar to phoenix contact MSTB 2.5 (2 to 24 positions ) – GF 5.08 & MSTB 2.5 (2 to 24 positions ) – STF 5.08 6.9 The Earthing arrangement shall be provided by the Railways & is not the part of the equipment This specification is the property of RDSO. No reproduction shall be done without the permission from DG (Telecom)/ RDSO / Lucknow. Page 22 of 27 7.0 Effective from 01.07.2007 RDSO / SPN / TC / 049 / 2003 Ver 3.0 Environmental Conditions The equipment shall be designed to comply environmental conditions as envisaged in Department of Telecommunication quality management document QM 333 in category B - 2. 8.0 Warranty The equipment shall have a minimum warranty of 1 year with a liability of technical support like stores, AMC and technical guidance for another 5 years or as per the tender requirements of the Railway 9.0 Type Approval The ASM / LC gate control equipment should have type approval from RDSO. The type approval test shall include factory test and climatic test to check the compliance of the specified parameters. The test shall be conducted as per test procedure to be prepared and submitted by the manufacture, RDSO may modify the test procedure, if required. The type approval test shall be conducted preferably at RDSO / Lucknow. However, in case of any difficulty of infrastructure or any other facility at RDSO, Lucknow, the type approval test may be conducted either at Manufacturer factory or in any other mutually agreed test Laboratory. All instrumentation and set up required for the test shall be provided by the manufacturer. Note: A complete set of items as per clause 2.3.2 and 2.3.3 will be submitted for Type approval. However Type Tests will be carried out on items 2.3.2 and 2.3.3 only. Other items will be from DGS&D/DCPW approved source. The certificate of the same shall be submitted at the time of approval. 9.1 Type Tests Number of samples for type test shall consists of one ASM control equipment and one LC gate equipment with all accessories The type approval of the equipment shall consist of following tests. 9.1.1 ‘BURN-IN’ Test: The equipment shall be ‘BURN-IN’ for a period of one day at 50o C prior to the actual measurement of parameters. During the burn - in the equipment shall be kept in ‘ON’ condition. 9.1.2 Bench Tests: After ‘BURN – IN’ Test, full functional tests shall be conducted as per specifications. 9.1.3 Environmental Testing The ranges of ambient temperature and humidity within which the equipment performance will be tested as per QM-333, Table 4.3, Category- B as given below a) Ambient temp. range over 0 C to 50 which specification are guaranteed ( 50% RH at max. temp.) b) Ambient temp. range over -5 C to 55C which equipment is to remain operational without causing irreversible damage (50% RH at max. temp) c) Storage temperature (50% RH at max. temp) without causing irreversible damage. -5 C to 60C d) Max. temp. for which specification are guaranteed at 95% humidity 35 C e) Maximum temp. range at which Equipment shall survive at 95% RH 40 C Applicable for thermal cycle only Applicable for damp heat steady state This specification is the property of RDSO. No reproduction shall be done without the permission from DG (Telecom)/ RDSO / Lucknow. Page 23 of 27 Effective from 01.07.2007 RDSO / SPN / TC / 049 / 2003 Ver 3.0 The environmental testing shall be conducted at per specification No. QM 333 for environmental testing of electronic equipment for transmission and switching use issued by DOT in Sept. 1990 (with latest amendment). The testing shall be as per category ‘B2’ and following tests shall be carried out. 9.1.3.1 9.1.3.2 9.1.3.3 9.1.3.4 9.1.3.5 Dry Heat : 55 + 20 C, Duration : 12 hours Damp heat (cyclic) Duration : 12 hours First Cycle of two cycles Upper temperature : 400 C Variant : 1 Rapid temp. cycling Low Temperature : -00 C + 3 0 C High Temperature : 550 C + 2 0 C Rate of change of temperature over a period of not more than 5 minutes shall be + 0.2 0 C per minute. Duration of Exposure : 3 hours Damp heat steady state Duration : 4 days Temperature : 35 + 2 0 C Relative Humidity : 95 + 0 or 95 –2% in the temperature range Vibration Frequency : 5 to 350 Hz Vibration Amplitude : +/- 6 mm constant displacement Duration at Resonance : 2 hours at each axis Magnitude of “g”: 1.5 9.1.4 Surge / Transit Testing Manufacture and assembly of this equipment shall be made according to the standard practices adopted by International Electro - Technical Commission (IEC61000-4-5). The equipment shall undergo testing on Surge / Transient as per latest guidelines as follows. Pulse : 1.2/50 uSec. Amplitude : 0.5 KV (DM) 1.0 KV (CM) No. of Pulse : 5 in each polarity Positive and Negative. EUT : Energised condition Test method : IEC61000-4-5 9.1.5 Final Test: After competition of all above said tests as explained in Para 9.1 , final functional test and measurement of electrical parameter shall be conducted. 9.1.6 Field Trial On competition of all the tests mentioned in Para 9.1.1, 9.1.2, 9.1.3, 9.1.4, field trial for four to six weeks will have to be conducted by installing complete equipment in a selected station and gates to judge the performance of the system. 9.2 After successful completion of all tests and field trail, as per Para 9.1, Type Approval Certificate may be issued. This specification is the property of RDSO. No reproduction shall be done without the permission from DG (Telecom)/ RDSO / Lucknow. Page 24 of 27 10.0 10.1 10.2 10.3 Effective from 01.07.2007 RDSO / SPN / TC / 049 / 2003 Ver 3.0 Inspection The inspection and test shall be carried out to the satisfaction of inspecting authority. The purchaser or his nominee shall have the right to be present during all stages of manufacture and shall be accorded all reasonable/complete facilities to satisfy himself that LC gate Control Equipment are being manufactured in accordance with the terms and conditions of the specification. The purchaser or his nominee shall have the right to reject any material that fails to confirm to the specification. Test certificates incorporating the results of the routine test and other manufacturing tests must be furnished in duplicate prior to the inspection for the use of purchaser/his nominee. 10.4 Burn – In Test The equipment shall be burn – in for a period of one day at 50 o C prior to the actual measurement of the parameters. During the burn-in, the equipment shall be kept in ‘ON’ condition. 10.5 Visual Inspection 10.5.1 The equipment shall be visually inspected to ensure that it is free from any cracks or any other imperfection including marking and painting etc 10.5.2 The equipment shall be checked to satisfy general requirement as per Para 11 & 14 10.6 Tests After burn - in and visual inspection, full functional tests shall be conducted as per Para 5.1 and Para 5.2. 10.7 Acceptance Tests Acceptance Test shall comprise of the following tests taken in sequential order as follows 10.7.1 Visual Inspection ( Para 10.5 ) 10.7.2 Electrical Characteristics Tests ( Para 6.1.1 & 6.1.2 ) 10.7.3 Performance Test ( Para 5.1 & 5.2 ) 10.8 Routine Tests Following routine tests shall be conducted by the manufacturer on all the LC Gate Control Equipments 10.8.1 Visual Inspection ( Para 10.5 ) 10.8.2 Electrical Characteristics Tests ( Para 6.1.1 & 6.1.2 ) 10.8.3 Performance Test ( Para 5.1 & 5.2 ) 10.9 Technical Literature Technical literature consisting of principles of working, circuit / block diagram maintenance and trouble shooting procedures, assembly drawing, spares parts catalogue, printed card layout diagram, along with the position of the components as per circuit diagram, shall be supplied along with equipment unless otherwise not desired by the user Railway. This specification is the property of RDSO. No reproduction shall be done without the permission from DG (Telecom)/ RDSO / Lucknow. Page 25 of 27 Effective from 01.07.2007 RDSO / SPN / TC / 049 / 2003 Ver 3.0 11.0 MARKING 11.1 The following information shall be clearly embossed / engraved / screen-printed at a conspicuous places. a) Item Name b) RDSO Specification Number c) Name or Monogram of the Manufacturer d) Year of manufacture e) Serial Number 11.2 Any other information specially requested and required by Purchaser. 12.0 SAMPLING: 12.1 Unless otherwise agreed to the purchaser and the supplier, the double sample plan given as below shall be adopted: Lot consisting LC Gate Control Equipment 1 Under 25 25 to 50 51 to 100 101 to 200 201 to 300 301 to 500 1st Sample size (NI) 2 3 7 10 13 20 25 2nd Sample size (N2) 3 6 14 20 26 40 50 Combined Sample size (N1 + N2) 5 9 21 30 39 60 75 Acceptance Number (C1) 5 0 0 0 0 1 1 Rejection Number (C2) 0 2 3 3 5 5 6 12.2 The number of Level Crossing gate control equipment (NI) as given in Col.2 shall first be selected and subjected to the acceptance test. If in the first sample, the number if defective LC Gate Control Equipment, that is those failing in one or more acceptance test is less than or equal to the corresponding number (C1) given in Col.5, that lot shall be considered as conforming to the requirement of the acceptance test. If the number of defective level crossing gate control equipment in the first sample is greater than or equal to the rejection number in Col.6, the lot shall be considered as not conforming to the requirements of the acceptance test. If number of defective level crossing gate control equipment in the first sample lies between C1 and C2 a second sample of size N2 as given in Col.3 shall be selected and subjected to the acceptance test. If in the combined sample, the number of defective level crossing gate control equipment is less than C2, the lot shall be considered as conforming to the requirement of acceptance test. 12.3 The Sample shall be selected at random from at least 10% of the Packages. For random selection of packages, all the packages in the lot shall be arranged in a serial order and every ‘r’ the package shall be selected until the requisite number of Packages is obtained. ‘r’ being the integral part of : 13. Total number of packages in the lot -------------------------------------------------Total number of Packages to be selected REJECTION Any of the materials, which do not comply with the requirements of this specification, may be rejected. 14. PACKING Equipment shall be suitably packed so as to avoid any damage or loss during storage and transit. This specification is the property of RDSO. No reproduction shall be done without the permission from DG (Telecom)/ RDSO / Lucknow. Page 26 of 27 Effective from 01.07.2007 RDSO / SPN / TC / 049 / 2003 Ver 3.0 Annexure - A SEQUENCE OF TYPE TEST Two Samples ( Para 9.1 ) Visual Inspection ( Para 10.5 ) Performance Test ( Para 5.1 & 5.2 ) Electrical Characteristics ( Para 6.1.1 & 6.1.2 ) One Sample Environmental Test ( As per Para 9.1.3.1, 9.1.3.2, 9.1.3.3, 9.1.3.4 ) Vibration Test ( As per Para 9.1.3.5 ) One Sample Surge / Transit Testing ( As per Para 9.1.4 ) This specification is the property of RDSO. No reproduction shall be done without the permission from DG (Telecom)/ RDSO / Lucknow. Page 27 of 27 Effective from 01.07.2007 RDSO / SPN / TC / 049 / 2003 Ver 3.0 Annexure - B *****END***** This specification is the property of RDSO. No reproduction shall be done without the permission from DG (Telecom)/ RDSO / Lucknow.
© Copyright 2026 Paperzz