Data Sheet P1 Series On/Off/Jog Control Proportional Control The P1 series quarter turn actuators are used on OEM applications such as filter and pump skids as well as process control, water treatment, and heating & cooling. Key features include: Actuator Specifications Comparison Actuator Torque “lb/Nm Supply Voltage Max Inrush Current Running Current Motor Runtime (90°@60Hz/vdc) Runtime (90°@50Hz) Duty Cycle Starts Per Hour Weight Mechanical Connections Manual Override Control SD15_P1A-C_LVHV_Ver N_100915 Actuator Torque “lb/Nm Supply Voltage Max Inrush Current Running Current Motor Runtime (90°@60Hz/vdc) Runtime (90°@50Hz) Duty Cycle Starts Per Hour Weight Mechanical Connections Manual Override Control P1.A P1 12vac/dc 24vac/dc 120vac 445”lbs/50Nm 230vac 2.0A 1.1A 0.6 0.4 1.9A 1.1A 0.6 0.3 DC Brush Type Split Phase Capacitor 15 sec 12 sec 15 sec 13 sec 75% 25%* 1200 per hour 5lbs/3kg ISO5211 F03/F05 8pt 14mm 8mm Socket Drive - Bottom Access On/Off/Jog or Proportional 24vac/dc 135”lbs/15Nm 12vac/dc 24vac/dc 120vac 120vac 230vac 1.5A 0.9A 0.6 0.4 1.3A 0.8A 0.6 0.3 DC Brush Type Split Phase Capacitor 20 sec 20 sec 20 sec 24 sec 75% 25%* 1200 per hour 7lbs/4kg ISO5211 F05/F07 8pt 17mm 5mm Hex Drive (XOV has no Override) On/Off/Jog or Proportional P1.C 135”lbs/15Nm 12vdc 5.1A 1.7A 230vac 2.0A 1.1A 0.6 0.4 1.9A 1.1A 0.6 0.3 DC Brush Type Split Phase Capacitor 8 sec 8 sec 8 sec 10 sec 75% 25% 1200 per hour 5lbs/3kg ISO5211 F03/F05 8pt 14mm 8mm Socket Drive - Bottom Access On/Off/Jog ONLY (2) 1/2” NPT 14-18ga (12-16ga P1.C only) Environmental Rating Actuator Case material NEMA 4/4X Aluminum Alloy, Powder coated 230°F/110°C Thermal F* Class *Totally Enclosed Non-Ventilated Motors -22°F to +125°F -30°C to +52°C Ambient Temperature Operating Range 12vac/dc P1.B Electrical Terminations Motor Protection (On/Off) Compact size A variety of run times Quick to install, easy to service Industrial grade components Override options for all 300”lbs/35Nm Common to all P1 Series Electrical Entry •• •• •• •• •• Page 1 of 4 P1 Series Overview 24vdc 5.4A 1.8A DC Brush Type 3 sec 3 sec 75% only 1200 per hour 5lbs/3kg ISO5211 F03/F05 8pt 14mm 8mm Socket Drive - Bottom Access On/Off ONLY * Duty Cycle for proportional actuators is 75% maximum. ProMation Engineering has an extensive stock of electric actuators and can ship product very rapidly, worldwide. Wiring Diagram On/Off/Jog Control SAMPLE DIAGRAM Refer to the proper IOM for your actuator for the correct wiring diagram or visit www.promationei.com. NOT CLOSED* F CLOSED* * CONNECTIONS OPTIONAL E NOT OPEN* C OPEN* B AUX SW COM* SW3 FIELD CONTROL DEVICE CLP OPEN PILOT* RUN CLOSED WD-850-12101E RUN OPEN AC Hot or DC+ NEG 24VAC or 24VDC AC Neu24VDC or DC-+ ALL SWITCHES SHOWN WITH ACTUATOR IN FULL CLOSED POSITION 408-30040 2 5 OPP CL 6 4 3 SW2 4 5 3 SW1 1 5 M 6 THERMAL SWITCH GND Screw Wire Gage E Use For: 18 150 P1(.B)(.C)-24N4-DC 16 236 Heavy Duty Drive Motor 14 12 10 8 381 583 992 1480 Switch Card Anti-Condensation Heater Aluminum Casting NEMA 4X Protection MAX distance between Wire Gage Actuator and Supply (feet) P1.A P1.B P1.C P1, P1.A, P1.B P1, P1.A, P1.B 0.9A 1.1A 5.4A 0.6A 0.4A 184 289 466 713 1212 1809 150 236 381 583 992 1480 48 78 119 202 302 1377 2165 3497 5348 9091 13569 3960 6223 10052 15374 26136 39009 24V 24V ships 24VDC in fully120VAC 230VAC Actuator closed position! 18 16 14 12 10 8 Wire sizing data is provided to assist in the selection of the proper wire size for ProMation P1 series actuators using various wire sizes over distance. Please make sure to reference the correct voltage and do not exceed the indicated length of the wire run for each model. Contact ProMation for 12 volt data or proportional data. Application Notes: Spacer 7 Items within dotted line located inside actuator housing MAX distance between Actuator and Supply (feet) P1 24V 1.1A Easily distinguishable yellow/red position indicator DC DRIVE MOTOR Wire Sizing Charts Aluminum Casting NEMA 4X Protection Easily accessible switch & cam stacks open AUXILIARY SWITCH (STANDARD) + (P1-120PN4 shown) NEMA 4X Cover Seal SW1 6 OP P Series Exploded View Proportional Control Card close 1 GND Position indicator viewport open aux SW2 HEATER 7 CLOSED PILOT* close aux SW3 Switch Stack Detail A - SW4 1.These actuators are designed to be used in either a horizontal or upright position. Do NOT mount the actuator with the top below a horizontal position. 2.When installing conduit, use proper techniques for entry into the actuator. Use drip loops to prevent conduit condensate from entering the actuator. 3.Both NPT conduit ports MUST use proper equipment to protect the NEMA 4X integrity of the housing. 4.The internal heater is to be used in ALL applications. 5.Do NOT install or store the actuator outdoors or in humid environments unless it is powered up and the heater is functioning. 6.Use proper wire size to prevent actuator failure. 7.Do not parallel wire on/off/jog actuators without utilizing isolation relays. Page 2 of 4 P1 Series Overview SD15_P1A-C_LVHV_Ver N_100915 Field Control Device may be relay contact, Switch or Triac type. Pilot device 3A MAX. Auxiliary switches are rated 3A @ 250vac MAX. Terminals A-F are dry type Form C. Terminals accept 14-18ga solid/stranded wire. SW4 AUXILIARY SWITCH (STANDARD) 1 Engineering Change Notice 1 Name Engineering Chang Description 2 2 Engineering Change Notice REV Change Date A Description KHL 08.21.2013 New Document B 04.15.2014 A 08.21.2013 New Document KHL C 10.07.2014 B 04.15.2014 Added tolerance on drive coupling data KHL D 04.08.2015 C 10.07.2014 Added tolerance on drive coupling data08.21.2013 A New Document Pushed square dimension to three decimal places B 04.15.2014 Added tolerance on drive coupling data for clarity Added Isometric view of Drive and "Depth" tag C Coupling Pushed square dimension to three decimal places 10.07.2014 D 04.08.2015 REV Change Date Name Description P1 Series Dimensional Data: E F 2 Added Isometric view of Drive Coupling and "Depth" tag for clarity Engineering Change Notice KHL Pushed square dimension to three decimal places KHL P1 Series Views REV Change Date C D 127 mm 5.0 in KHL Added tolerance on drive coupling data KHL KHL KHL Added Isometric view of Drive Coupling and "Depth" tag for clarit E KHL 66 mm 57 mm Pushed square dimension to three decimal places 10.07.2014 2.2andin"Depth" tag for clarity inIsometric view of Drive Coupling 04.08.20152.6 Added 04.15.2014 D (Typical, some views rotated for04.08.2015 clarity) F Name Description (P1-120VN4 shown, some views rotated for clarity) 08.21.2013 New Document B REV Change Date P1.A Series Views E A KHL F 127 mm 5.0 in KHL E F 1 66 mm 2.6 in 2 2 Engineering Change Notice 57 mm 2.2 in REV Change Date 114 mm 4.5 in B 08.21.2013 New Document KHL B 04.15.2014 Added tolerance on drive coupling data KHL C 10.07.2014 Pushed square dimension to three decimal places KHL D 04.08.2015 Added Isometric view of Drive Coupling and "Depth" tag for clarity KHL A A 66 mm 2.6 in 57 mm 2.2 in 70 mm 2.8 in 106 mm 4.2 in (2) 1/2" NPT EMT Entry (2) 1/2" NPT EMT Entry 5 mm 0.2 in Hex Key 35 mm 1.4 in 35 mm mm 1.4 in (2) 1/2” NPT EMT Entry Proportional On/Off Control Control B 150mm 183 mm 5.9 in 7.2 in Add 115mm [4.5"]183 to allow mm 7.2 in for cover removal Add 115mm [4.5"] to allow for cover removal 5 mm 0.2 in Hex KeyNPT (2) 1/2" 106 mm 4.2 in View A-A 352-544-8436 Mation Engineering, 52-544-8439 ithout the written forbidden. ty for Damages. ne: 352-544-8436 : 352-544-8439 A A Proportional On/Off Control Control 229 mm 196mm 9.0 in 7.7 in Add 115mm [4.5"] to allow for cover removal. (2) 1/2" NPT EMT Entr 183 mm 8EMT mm Entry 14.00 mm 0.3 in 7.2 in 0.551 in Square Add 115mm 50 mm 8mm 102 mm A [4.5"] to17.00 allowmm 14.00 mm4.0 0.32.0 in in 5mm 0.669 in 102(0.2 mmin) in for cover BHC 0.551 in Hex4.0 Keyin Override Square removal Square M6x1 50 mm Data Drive Coupling (4) Fabrication 50 mmData 5 mm Fabrication 2.0 inDrive Coupling 10mm 0.2 in 50 mm +.00Bmm BHC 2.0 in 0.4" 17.00 - .13 +.00 Hex Key 36 mm 1.4 in BHC 66 2.6 70 mm 2.8 in 114 mm 4.5 in (2) 1/2" NPT EMT Entry (2) 1/2" NPT EMT Entry 00 Data 36 mm (4) M5x0.8 05 in 1.4 8mm in 00 mm BHC 13 0.3" 000 +0.000 (4) M6x1 (4) M5x0.8 005 in 0.669 - 0.005 in 10mm 8mm +.00 mm B A .13 A 0.3" 8 mm 0.4" +0.000 0.3 in in F03/F05 ISO Flange 0.005 79 mm 35 mm +.00 0 - .13 mm 3.1 in 1.4 in +.00 8 mm 17.00 mm 17.00 - .13 mm 8mm (0.3 in) +0.000 1 - 0.005 in F03/F05 0.669 in Data 0.3 in 17.00 mm + Dwg. Name ISO Flange P1 F05 8P14 DimData.idw on Engineering, Drive Coupling Fabrication 0.000 Socket Drive Override ut the written bidden. or Damages. 66 mm 2.6 in F 114 mm 4.5 in 57 2.2 Name A E B 57 mm 2.2 in Description 106 mm 4.2 in SD15_P1A-C_LVHV_Ver N_100915 ta 2 BHC 17.00 - .13 mm +0.000 0.669 - 0.005 in (4) M6x1 2.0 in BHC 17.00 mm 0.669 in Square 70 mm 2.8 in BHC (4) M8x1.25 12mm (4) M6x1 0.5" 8 mm 102 mm 14.00 mm 0.3 in 10mm 4.0 in 0.4" +.00 0.551 in 0.4" 17.00 - .13 mm Square F05/F07 ISO Drive Coupling Fabrication DataFlange 50 mm 0.669 in mm 0.669 Depth Rev. 36 +0.000 - 0.005 in F05/F07 50 mmI 0.669 - 0.005 in Depth 2.0 in D1.4 in +.00 + Drawn By Part No. .00 Created: Drive Coupling Fabrication Data 2.0 in mm mm 14.00 17.00 BHC KHL P1 Dimensional4/25/2013 BHC Part No. - .13 Drawn for By Proportional Created: .13 Data Units Dwg. Name BHC P1 F05 8P14 DimData.idw 4/25/2013 KHL +0.000 Checked By Last Checked: +0.000 Dwg. Name 0.551 in in 0.669 4/8/2015 Sheet Number: 2 P1A F07 8P17 DimData.idw Checked By KHL This Document is the property of ProMation Engineering, (4) M6x1 Rev. NO SCALE Last Checked: (4) M5x0.8 0.005Inc. Distribution of this document without the written - 0.005 Dwg. Name 4/8/2015 D Finish KHL Material P1A F07 8P17 DimData.idw This A Document is the property of ProMation Engineering, 2 10mm consent of the owner is Strictly forbidden. 8mm Rev. B Inc. Distribution of this document without the written Finish Material Failure to comply will incur a liability for Damages. consent of the owner is Strictly forbidden. P1 Dimensional Data for Proportional Units D (4) M6x1 0.4" 0.3" Failure to comply will incur a liability for Damages. Dimensional Tolerances (Unless Otherwise Noted): X ± 2.5mm [X.X ± .1] Dimensional Tolerances (Unless Otherwise Noted): Promation Engineering Inc. Sheet Number: 2 Dimensional Data for P1.A Proportional Actuators 10mm NO SCALE X.X ± .3mm [X.XX ± .01"] Phone: 352-544-8436 ± .1] X ± 2.5mm 16138[X.X Flight Path Drive Promation Engineering Inc. X.XX ± .13mm [X.XXX ± .005"] Dimensional Data for P1.A Proportion Fax: 352-544-8439 [X.XX ± .01"] Brooksville, Fl 34604 Phone: 352-544-8436 2 X.X ± .3mm 16138 Flight Path Drive ALL TOLERANCE FEATURES IN mm +.00 mm Number: 20.4" X.XX ± .13mm ± .005"] NO Fax: SCALE +.00[X.XXX 352-544-8439 17.00 mm 17.00 Sheet Brooksville, Fl 34604 mm IN mm 15.00 mm 14.00 ALL TOLERANCE FEATURES - .13 NO SCALE .13 2 1 0.669 in 8 mm 0.591 in +0.000 +0.000 2 0.669 - 0.005 in 1 Depth 0.3 in 0.551 - 0.005 in F03/F05 ISO Flange Depth Page 3 of 4 P1 Series Overview ProMation Engineering, Inc. 10mm ProMation Engineering, Inc. Created: 4/24/2013 Part No. ProMation Engineering, Inc. ProMation Engineer Drawn By Created: Checked By Last Checked: KHL 4/25/2013 Part No. ProMation Engineering, Inc. Dwg. Na Product Ordering Example Product Family P1- 1 1.A 1.B 1.C 300”lbs/35Nm 445”lbs/50Nm 135”lbs/15Nm 135”lbs/15Nm Control Options Voltage Options 24 12 12VAC/DC610% 24 24VAC/DC610% 120 120VAC610% 230 230VAC610% 12 12VAC/DC610% 24 24VAC/DC610% 120 120VAC610% 230 230VAC610% 12 12VAC/DC610% 24 24VAC/DC610% 120 120VAC610% 230 230VAC610% On/Off or V only 12VDC610% 24 24VDC610% N 4 - AC On/Off P Standard Proportional N Non-Spring Return 4 NEMA 4X On/Off On/Off or V only 12 Special Designations P Standard Proportional N Non-Spring Return 4 NEMA 4X On/Off N Non-Spring Return 4 NEMA 4X On/Off N Non-Spring Return 4 NEMA 4X AC 12 or 24VAC DC 12 or 24VDC ED Extended Duty Motor RO Relay Open RC Relay Close XOV (2 pos) (2 pos) No Override (P1.A Only) Note: Not all combinations are possible. Please consult factory. ISO F03/05 Mounting Detail, 8 point 14mm female drive, and 8mm socket override on P1, P1.B, and P1.C Series actuators. Simplified wiring under the cover makes field connections easier and less prone to loose connections and wiring errors. ProMation Engineering follows a policy of continual product updates and enhancements. Our website is the best place to obtain the latest product documentation, including the wiring diagrams for these controllers. www.promationei.com or use this code to visit the site. 16138 Flight Path Drive Brooksville, FL 34604 Phone (352) 544-8436 Fax (352) 544-8439 email: [email protected] Page 4 of 4 P1 Series Overview Use your smart phone barcode scanner app here.
© Copyright 2026 Paperzz