P1, P1.A, P1.B, P1.C Overview

Data Sheet
P1 Series
On/Off/Jog Control
Proportional Control
The P1 series quarter turn actuators are used on OEM
applications such as filter and pump skids as well as process
control, water treatment, and heating & cooling.
Key features include:
Actuator Specifications Comparison
Actuator
Torque “lb/Nm
Supply Voltage
Max Inrush Current
Running Current
Motor
Runtime (90°@60Hz/vdc)
Runtime (90°@50Hz)
Duty Cycle
Starts Per Hour
Weight
Mechanical Connections
Manual Override
Control
SD15_P1A-C_LVHV_Ver N_100915
Actuator
Torque “lb/Nm
Supply Voltage
Max Inrush Current
Running Current
Motor
Runtime (90°@60Hz/vdc)
Runtime (90°@50Hz)
Duty Cycle
Starts Per Hour
Weight
Mechanical Connections
Manual Override
Control
P1.A
P1
12vac/dc
24vac/dc
120vac
445”lbs/50Nm
230vac
2.0A
1.1A
0.6
0.4
1.9A
1.1A
0.6
0.3
DC Brush Type
Split Phase Capacitor
15 sec
12 sec
15 sec
13 sec
75%
25%*
1200 per hour
5lbs/3kg
ISO5211 F03/F05 8pt 14mm
8mm Socket Drive - Bottom Access
On/Off/Jog or Proportional
24vac/dc
135”lbs/15Nm
12vac/dc
24vac/dc
120vac
120vac
230vac
1.5A
0.9A
0.6
0.4
1.3A
0.8A
0.6
0.3
DC Brush Type
Split Phase Capacitor
20 sec
20 sec
20 sec
24 sec
75%
25%*
1200 per hour
7lbs/4kg
ISO5211 F05/F07 8pt 17mm
5mm Hex Drive (XOV has no Override)
On/Off/Jog or Proportional
P1.C
135”lbs/15Nm
12vdc
5.1A
1.7A
230vac
2.0A
1.1A
0.6
0.4
1.9A
1.1A
0.6
0.3
DC Brush Type
Split Phase Capacitor
8 sec
8 sec
8 sec
10 sec
75%
25%
1200 per hour
5lbs/3kg
ISO5211 F03/F05 8pt 14mm
8mm Socket Drive - Bottom Access
On/Off/Jog ONLY
(2) 1/2” NPT
14-18ga (12-16ga P1.C only)
Environmental Rating
Actuator Case material
NEMA 4/4X
Aluminum Alloy, Powder coated
230°F/110°C Thermal F* Class
*Totally Enclosed Non-Ventilated Motors
-22°F to +125°F
-30°C to +52°C
Ambient Temperature
Operating Range
12vac/dc
P1.B
Electrical Terminations
Motor Protection (On/Off)
Compact size
A variety of run times
Quick to install, easy to service
Industrial grade components
Override options for all
300”lbs/35Nm
Common to all P1 Series
Electrical Entry
••
••
••
••
••
Page 1 of 4 P1 Series Overview
24vdc
5.4A
1.8A
DC Brush Type
3 sec
3 sec
75% only
1200 per hour
5lbs/3kg
ISO5211 F03/F05 8pt 14mm
8mm Socket Drive - Bottom Access
On/Off ONLY
*
Duty Cycle for proportional
actuators is 75% maximum.
ProMation Engineering has an
extensive stock of electric actuators
and can ship product very rapidly,
worldwide.
Wiring Diagram
On/Off/Jog Control
SAMPLE DIAGRAM
Refer to the proper IOM for your actuator for the
correct wiring diagram or visit www.promationei.com.
NOT CLOSED*
F
CLOSED*
* CONNECTIONS
OPTIONAL
E
NOT OPEN*
C
OPEN*
B
AUX SW COM*
SW3
FIELD
CONTROL
DEVICE
CLP
OPEN PILOT*
RUN CLOSED
WD-850-12101E
RUN OPEN
AC Hot or DC+
NEG
24VAC or 24VDC
AC Neu24VDC
or DC-+
ALL SWITCHES
SHOWN WITH
ACTUATOR IN
FULL CLOSED
POSITION
408-30040
2
5
OPP
CL
6
4
3
SW2
4
5
3
SW1
1
5
M
6
THERMAL SWITCH
GND Screw
Wire
Gage
E
Use For:
18
150
P1(.B)(.C)-24N4-DC
16
236
Heavy Duty
Drive Motor
14
12
10
8
381
583
992
1480
Switch
Card
Anti-Condensation
Heater
Aluminum Casting
NEMA 4X Protection
MAX distance between
Wire
Gage Actuator and Supply (feet)
P1.A
P1.B
P1.C
P1, P1.A, P1.B
P1, P1.A, P1.B
0.9A
1.1A
5.4A
0.6A
0.4A
184
289
466
713
1212
1809
150
236
381
583
992
1480
48
78
119
202
302
1377
2165
3497
5348
9091
13569
3960
6223
10052
15374
26136
39009
24V
24V ships
24VDC in fully120VAC
230VAC
Actuator
closed position!
18
16
14
12
10
8
Wire sizing data is provided to assist in the selection of the proper wire size for
ProMation P1 series actuators using various wire sizes over distance. Please make
sure to reference the correct voltage and do not exceed the indicated length of the
wire run for each model. Contact ProMation for 12 volt data or proportional data.
Application Notes:
Spacer
7
Items within dotted line located inside actuator housing
MAX distance between
Actuator and Supply (feet)
P1
24V
1.1A
Easily distinguishable
yellow/red position
indicator
DC DRIVE
MOTOR
Wire Sizing Charts
Aluminum Casting
NEMA 4X Protection
Easily accessible
switch & cam stacks
open
AUXILIARY
SWITCH
(STANDARD)
+
(P1-120PN4 shown)
NEMA 4X Cover Seal
SW1
6
OP
P Series Exploded View
Proportional
Control Card
close
1
GND
Position indicator
viewport
open aux
SW2
HEATER
7
CLOSED PILOT*
close aux
SW3
Switch Stack
Detail
A
-
SW4
1.These actuators are designed to be used in either a horizontal or upright position.
Do NOT mount the actuator with the top below a horizontal position.
2.When installing conduit, use proper techniques for entry into the actuator. Use drip
loops to prevent conduit condensate from entering the actuator.
3.Both NPT conduit ports MUST use proper equipment to protect the NEMA 4X integrity
of the housing.
4.The internal heater is to be used in ALL applications.
5.Do NOT install or store the actuator outdoors or in humid environments unless it is
powered up and the heater is functioning.
6.Use proper wire size to prevent actuator failure.
7.Do not parallel wire on/off/jog actuators without utilizing isolation relays.
Page 2 of 4 P1 Series Overview
SD15_P1A-C_LVHV_Ver N_100915
Field Control Device may be relay
contact, Switch or Triac type.
Pilot device 3A MAX.
Auxiliary switches are rated 3A
@ 250vac MAX.
Terminals A-F are dry type
Form C.
Terminals accept
14-18ga solid/stranded wire.
SW4
AUXILIARY
SWITCH
(STANDARD)
1
Engineering Change Notice 1
Name
Engineering Chang
Description
2
2
Engineering Change Notice
REV Change Date
A
Description KHL
08.21.2013
New Document
B
04.15.2014
A
08.21.2013
New Document
KHL
C
10.07.2014
B
04.15.2014
Added tolerance on drive coupling data
KHL
D
04.08.2015
C
10.07.2014
Added tolerance on drive coupling
data08.21.2013
A
New Document
Pushed square dimension to three decimal places
B
04.15.2014
Added tolerance on drive coupling data
for clarity
Added Isometric view of Drive
and "Depth" tag
C Coupling
Pushed
square dimension to three decimal places
10.07.2014
D
04.08.2015
REV Change Date
Name
Description
P1 Series Dimensional Data:
E
F
2
Added Isometric view of Drive Coupling and "Depth" tag for clarity
Engineering Change Notice
KHL
Pushed square dimension to three decimal places
KHL
P1 Series Views
REV Change Date
C
D
127 mm
5.0 in
KHL
Added tolerance on drive coupling data
KHL
KHL
KHL
Added Isometric view of Drive Coupling and "Depth" tag for clarit
E
KHL
66 mm
57 mm
Pushed square dimension to three decimal places
10.07.2014
2.2andin"Depth" tag for clarity
inIsometric view of Drive Coupling
04.08.20152.6
Added
04.15.2014
D
(Typical, some views rotated
for04.08.2015
clarity)
F
Name
Description
(P1-120VN4
shown,
some views rotated for clarity)
08.21.2013
New Document
B
REV Change Date
P1.A Series Views
E
A
KHL
F
127 mm
5.0 in
KHL
E
F
1
66 mm
2.6 in
2
2
Engineering Change Notice
57 mm
2.2 in
REV Change Date
114 mm
4.5 in
B
08.21.2013
New Document
KHL
B
04.15.2014
Added tolerance on drive coupling data
KHL
C
10.07.2014
Pushed square dimension to three decimal places
KHL
D
04.08.2015
Added Isometric view of Drive Coupling and "Depth" tag for clarity
KHL
A
A
66 mm
2.6 in
57 mm
2.2 in
70 mm
2.8 in
106 mm
4.2 in
(2) 1/2" NPT
EMT Entry
(2) 1/2" NPT
EMT Entry
5 mm
0.2 in
Hex Key
35 mm
1.4 in
35 mm
mm 1.4 in
(2) 1/2” NPT
EMT Entry
Proportional On/Off
Control
Control
B
150mm
183 mm
5.9 in
7.2 in
Add 115mm
[4.5"]183
to allow
mm
7.2 in
for cover
removal
Add 115mm
[4.5"] to allow
for cover
removal
5 mm
0.2 in
Hex
KeyNPT
(2) 1/2"
106 mm
4.2 in
View A-A
352-544-8436
Mation
Engineering,
52-544-8439
ithout the written
forbidden.
ty for Damages.
ne: 352-544-8436
: 352-544-8439
A
A Proportional
On/Off Control
Control 229 mm
196mm 9.0 in
7.7 in
Add 115mm
[4.5"] to allow
for cover
removal.
(2) 1/2" NPT
EMT Entr
183 mm
8EMT
mm Entry
14.00 mm 0.3 in
7.2 in
0.551 in
Square
Add 115mm
50 mm
8mm
102
mm
A
[4.5"] to17.00
allowmm
14.00 mm4.0
0.32.0
in in
5mm
0.669 in
102(0.2
mmin)
in
for
cover
BHC
0.551 in
Hex4.0
Keyin
Override
Square
removal
Square
M6x1
50 mm Data
Drive Coupling (4)
Fabrication
50 mmData 5 mm
Fabrication
2.0 inDrive Coupling
10mm
0.2 in 50 mm
+.00Bmm
BHC
2.0 in
0.4" 17.00 - .13
+.00 Hex Key
36 mm
1.4 in
BHC
66
2.6
70 mm
2.8 in
114 mm
4.5 in
(2) 1/2" NPT
EMT Entry
(2) 1/2" NPT
EMT Entry
00
Data
36 mm
(4) M5x0.8
05 in
1.4
8mm
in
00 mm
BHC
13
0.3"
000
+0.000
(4) M6x1
(4) M5x0.8
005 in
0.669 - 0.005 in

10mm

8mm
+.00 mm
B
A
.13
A
0.3"
8 mm 0.4"
+0.000
0.3 in
in F03/F05 ISO Flange
0.005
79 mm
35 mm
+.00
0 - .13 mm
3.1 in
1.4 in
+.00
8 mm
17.00 mm
17.00 - .13 mm
8mm
(0.3
in)
+0.000
1 - 0.005 in F03/F05
0.669
in Data 0.3 in 17.00 mm +
Dwg. Name ISO Flange
P1 F05
8P14 DimData.idw
on Engineering,
Drive Coupling
Fabrication
0.000
Socket Drive Override
ut the written
bidden.
or Damages.
66 mm
2.6 in
F
114 mm
4.5 in
57
2.2
Name
A
E
B
57 mm
2.2 in
Description
106 mm
4.2 in
SD15_P1A-C_LVHV_Ver N_100915
ta
2
BHC
17.00 - .13 mm
+0.000
0.669 - 0.005 in
(4) M6x1
2.0 in
BHC
17.00 mm
0.669 in
Square
70 mm
2.8 in
BHC
(4) M8x1.25
12mm
(4) M6x1
0.5"
8 mm
102 mm
14.00 mm
0.3 in
10mm
4.0 in
0.4"
+.00 0.551 in 0.4"
17.00 - .13 mm
Square
F05/F07 ISO
Drive Coupling
Fabrication
DataFlange
50 mm
0.669
in mm
0.669
Depth
Rev.
36
+0.000
- 0.005 in
F05/F07
50 mmI
0.669 - 0.005 in
Depth
2.0
in
D1.4 in
+.00
+
Drawn By
Part No.
.00
Created:
Drive
Coupling
Fabrication
Data
2.0 in
mm
mm
14.00
17.00 BHC
KHL P1 Dimensional4/25/2013
BHC Part No.
- .13
Drawn for
By Proportional
Created:
.13
Data
Units
Dwg. Name
BHC
P1
F05
8P14
DimData.idw
4/25/2013
KHL +0.000
Checked By
Last Checked:
+0.000
Dwg. Name
0.551
in
in
0.669
4/8/2015
Sheet
Number:
2
P1A
F07
8P17
DimData.idw
Checked
By KHL
This
Document
is
the
property
of
ProMation
Engineering,
(4)
M6x1
Rev.
NO SCALE
Last
Checked:
(4)
M5x0.8
0.005Inc. Distribution of this document without the written
- 0.005
Dwg. Name
4/8/2015 D
Finish KHL
Material
P1A F07 8P17 DimData.idw
This A
Document is the property of ProMation Engineering,
2
10mm
consent of the owner
is Strictly forbidden.
8mm
Rev.
B
Inc. Distribution of this document without the written
Finish
Material
Failure to comply will incur a liability for Damages.
consent of the owner is Strictly forbidden.
P1 Dimensional Data for Proportional
Units
D
(4) M6x1
0.4"
0.3" Failure to comply will incur a liability for Damages.
Dimensional Tolerances (Unless Otherwise Noted):
X ± 2.5mm [X.X ± .1] Dimensional Tolerances
(Unless
Otherwise
Noted):
Promation
Engineering
Inc.
Sheet
Number:
2
Dimensional Data for P1.A Proportional Actuators 10mm
NO SCALE
X.X ± .3mm [X.XX ± .01"]
Phone: 352-544-8436
± .1]
X ± 2.5mm
16138[X.X
Flight
Path Drive
Promation
Engineering Inc.
X.XX ± .13mm [X.XXX ± .005"]
Dimensional Data for P1.A Proportion
Fax:
352-544-8439
[X.XX ± .01"]
Brooksville,
Fl 34604
Phone: 352-544-8436
2 X.X ± .3mm
16138 Flight Path Drive
ALL TOLERANCE FEATURES IN mm
+.00 mm
Number: 20.4"
X.XX ± .13mm
± .005"]
NO Fax:
SCALE
+.00[X.XXX
352-544-8439
17.00 mm
17.00 Sheet
Brooksville, Fl 34604
mm IN mm
15.00 mm
14.00
ALL
TOLERANCE FEATURES
- .13
NO
SCALE
.13
2
1
0.669 in
8 mm
0.591 in
+0.000
+0.000
2
0.669 - 0.005 in 1
Depth
0.3
in
0.551 - 0.005 in F03/F05
ISO
Flange
Depth
Page 3 of 4 P1 Series Overview
ProMation Engineering, Inc.
10mm
ProMation Engineering, Inc.
Created:
4/24/2013
Part No.
ProMation Engineering, Inc.
ProMation Engineer
Drawn By
Created:
Checked By
Last Checked:
KHL
4/25/2013
Part No.
ProMation Engineering, Inc.
Dwg. Na
Product Ordering Example
Product
Family
P1-
1
1.A
1.B
1.C
300”lbs/35Nm
445”lbs/50Nm
135”lbs/15Nm
135”lbs/15Nm
Control
Options
Voltage
Options
24
12
12VAC/DC610%
24
24VAC/DC610%
120
120VAC610%
230
230VAC610%
12
12VAC/DC610%
24
24VAC/DC610%
120
120VAC610%
230
230VAC610%
12
12VAC/DC610%
24
24VAC/DC610%
120
120VAC610%
230
230VAC610%
On/Off or V only
12VDC610%
24
24VDC610%
N
4 -
AC
On/Off
P
Standard
Proportional
N
Non-Spring
Return
4
NEMA
4X
On/Off
On/Off or V only
12
Special Designations
P
Standard
Proportional
N
Non-Spring
Return
4
NEMA
4X
On/Off
N
Non-Spring
Return
4
NEMA
4X
On/Off
N
Non-Spring
Return
4
NEMA
4X
AC
12 or 24VAC
DC
12 or 24VDC
ED
Extended Duty
Motor
RO
Relay Open
RC
Relay Close
XOV
(2 pos)
(2 pos)
No Override
(P1.A Only)
Note: Not all combinations are possible. Please consult factory.
ISO F03/05 Mounting Detail, 8 point 14mm
female drive, and 8mm socket override on
P1, P1.B, and P1.C Series actuators.
Simplified wiring under the cover makes
field connections easier and less prone to
loose connections and wiring errors.
ProMation Engineering follows a policy of continual product updates and enhancements. Our website is the best place to obtain the latest
product documentation, including the wiring diagrams for these controllers.
www.promationei.com or use this code to visit the site.
16138 Flight Path Drive
Brooksville, FL 34604
Phone (352) 544-8436 Fax (352) 544-8439
email: [email protected]
Page 4 of 4 P1 Series Overview
Use your smart phone barcode