Clarity User Training Installation and configuration Code P010 Date: 20.2.2007 1 Installation Software protection Software installation HW installation Software configuration Code P010 Date: 20.2.2007 2 Software Protection Software protection by hardware key Hardware key (dongle) required for each station USB standard (LPT optional on request) The software is independent of hardware (A/D boards) User code (16 position alfanumeric code) combined with the apropriate dongle (S/N yyyy) is necessary to operate the Clarity Datastation (S/N xx-zyyyy) 30 day trial version available IMPORTANT !! Please note that a loss of a dongle (hardware key) is considered as a loss of the license right to use Clarity SW. Code P010 Date: 20.2.2007 3 Software Installation Install the software first before any hardware! Insert the CD Start install.exe (if not started automatically) Follow the dialog screens Set the installation directory Code P010 Date: 20.2.2007 4 Software Installation Select type of installation Typical should be used in most cases Set the program folder Code P010 Date: 20.2.2007 5 Software Installation Enter the User code corresponding to the HW key used Leave blank for 30 day Trial mode Chose acquisition device which would you like to set as default Code P010 Date: 20.2.2007 6 Software Installation Wait for next screen, the installation is in progress Code P010 Date: 20.2.2007 7 Software Installation Start the Hardware installation Wait for next screen, the installation is in progress Code P010 Date: 20.2.2007 8 Software Installation Finish the Hardware installation Wait for the installation to finish Code P010 Date: 20.2.2007 9 Software Installation Finish the software installation Show readme.txt file Run Clarity (do not check with hardware not yet installed!) Run IQ utility Code P010 Date: 20.2.2007 10 Hardware Installation Switch off the computer Insert the INT7 A/D board to a free PCI slot Switch on the computer Follow the New Hardware Found dialogs Code P010 Date: 20.2.2007 11 Hardware Installation Select „No, not this time“ for updates search Select Install Automatically (first time installation on a new computer) Code P010 Date: 20.2.2007 12 Hardware Installation Wait, Installation is in progress This warning may appear under some circumstances. It is safe to ignore it, use „Continue Anyway“ to proceed Code P010 Date: 20.2.2007 13 Hardware Installation Finish the hardware installation Insert the HW key New hardware found notice will shortly appear, the installation is automatic Code P010 Date: 20.2.2007 14 Electric connections Inputs IN1-IN4 Symmetric inputs – the shield cable must be connected Digital output (Relay) Starting cable Red Shielding Signal cable Red White START (REMOTE, …) 1V (100mV, Hi, +, …) 0 (COM, AGND, …) Shielding NONSYMMETRICAL CONNECTION Digital output (Relay) Starting cable Red Shielding Signal cable Red White Shielding SYMMETRICAL CONNECTION Code P010 Date: 20.2.2007 START (REMOTE, …) + (+1V, Hi, …) - (-1V, Lo, …) COM (0, GND) 15 Clarity First Start Start Clarity using the desktop icon Registration Dialog Needed for on-line updates Click here to open instrument Login Dialog Enter your name Code P010 Date: 20.2.2007 16 Configuration User Accounts user access privileges Configuration configuration of the datastation Directories working directories for individual instruments Digital Outputs setting and assignment of digital outputs System/Configuration Code P010 Date: 20.2.2007 17 User Accounts window To define users When several Code P010 Date: 20.2.2007 operators use the station for different analyses The desktop file (user profile) stores information about last used project, table and graph settings, last opened files, etc. 18 User Accounts Leave blank for unprotected mode. (All users will share common desktop file) Leave zeros for empty passwords or not restricted password life time. Fill in accordance with your company rules for GLP and 21CFRpart11 compliance User can change his/her password in the User Account Details dialog Code P010 Date: 20.2.2007 19 System Configuration window Setting of displayed instruments (data acquisition allowed only on instruments with purchased licence) Instrument type selection Installed devices Available Control modules Selected instrument configuration (add devices) Code P010 Date: 20.2.2007 Select the digital input and output for synchronisation 20 System Configuration window Available Control Modules list Device configuration (doubleclick the device icon) Code P010 Date: 20.2.2007 21 Directories window Working directories enables working with data over network Directory = where the available projects are searched for Useful for connecting of Eval version from other computer Blank = Clarity instalation directory Blank = LOG subdirectory of Clarity instalation directory Code P010 Date: 20.2.2007 22 Projects Chromatography data storage according to user analysis type sample type time Code P010 Date: 20.2.2007 23 File and Folders structure Main Clarity directory program files, configuration, user settings COMMON Subdirectory report styles (*.sty), default method templates, other files shared between projects Projects Subdirectory project files info (*.prj) Project Directory methods (met.*), sequences (seq.*) Project CALIB subdirectory calibration files (cal.*) and standard chromatograms (*.prm) Project DATA subdirectory sample chromatograms (*.prm) Code P010 Date: 20.2.2007 24 Chromatogram files RAW raw data file data as received from A/D converter created at run start and incremented during analysis actual and last processed stored in TMP subdirectory PRM primary data integrated data created when analysis is finished contains RAW data, history and copy of calibration file CAL calibration file contains data for calibrated results calculations referenced from method and chromatograms actual copies stored in saved chromatogram Code P010 Date: 20.2.2007 25 Functionality Check 1) Open Data Acquisition window. The signal will drift if the signal cable wires are free and should be within a few µV from 0 mV if the are interconnected. You can also compare the detector display reading and reaction to autozero. 2) Upon the injection (closing the marker contact) the analysis will start. Data Acquisition window will change in appearance. Note: The optional Validator can be used to check the system correct function Code P010 Date: 20.2.2007 26
© Copyright 2025 Paperzz