Insulated Roof & Wall Panels Kingspan K-Dek Product Guide Kingspan K-Dek (KS1000 KD) High Performance Insulated Membrane Roofdeck System Kingspan K-Dek Insulated Membrane Roofdeck Kingspan K-Dek is an energy efficient, high performance insulated single-ply membrane roofdeck system, suitable for flat, pitched and curved roofing applications. A factory-manufactured single component system, Kingspan K-Dek delivers continuity of insulation and low air leakage certainty that can reduce operational energy consumption and costs by up to 40%, when compared to conventional roof construction methods. The factory-adhered, high performance membrane is BBA certified and has a lifetime durability of 30 years. Note: All photos in this brochure are of the UK manufactured Kingspan Topdek. Kingspan K-Dek is the Australian equivalent product. 2 Contents Features & Benefits 5 System Overview 6 Kingspan EnvelopeFirst™ 8 Product Data 10 Technical Construction Details 13 Side / End Lap & Fastener Locations Parapet Eaves Eaves Boundary Gutter Verge Start Verge End Verge Parapet Ridge Valley with Rainwater Outlet Valley Gutter Concrete Parapet Barrel Vault Rooflights Kerb Penetration Roof Aperture Natural Daylighting Systems Ventilation & Extraction Expansion Joint M&E Services Support Platform 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 Kingspan K-Dek Fabrications 30 Height Safety Solutions 32 Kingspan Safepro2 Fall Protection System 32 Model Specification 34 Installation Overview 36 Case Studies 38 Insulated Roof & Wall Panels 42 Product Range at a Glance 42 3 4 Features & Benefits Featuring Kingspan’s unique FIREsafe insulation, Kingspan K-Dek is fully compliant with Australian and New Zealand building regulations, codes and standards and is suitable for new build and refurbishment applications. Kingspan K-Dek provides fast build, single-fix installation and is compatible with a range of integrated drainage, daylighting, HVAC plant support, flashings, trims, lightning protection and safety systems. Site installation is supported by a network of trained contractors. The thermal and structural performance of Kingspan K-Dek panels is guaranteed for up to 20 years, covered by the Kingspan TOTAL warranty. Features & Benefits ■ ■ ■ Accelerated build speed – factory-manufactured, single component system. Roofing membrane from Sika is BBA tested and certified with 30 year lifetime durability. White, highly reflective Sikaplan SGK AU available for cool roof applications. ■ Décor aesthetic standing seam option is available. ■ High thermal performance in meeting local building codes. ■ ■ Part of Kingspan’s EnvelopeFirst™ energy efficiency strategy – can reduce energy consumption by up to 40%. Available in lengths of 2.0 to 13.7 metres, subject to transport limitations. ■ Pre-finished bright white internal surface as standard. ■ Can eliminate the need for valley, boundary wall and hip gutters. ■ Building Sectors Compatible with drainage systems, daylighting solutions, HVAC plant supports, flashings, trims, lightning protection and safety systems. ■ Industrial and Manufacturing ■ Distribution, Logistics and Transport Suitable for flat, pitched or curved roof applications. ■ Commercial, Office and Retail Thermal and structural performance covered by the Kingspan TOTAL warranty. ■ Leisure, Sport & Hotels ■ ■ Student Accommodation, Education and Healthcare Fibre-free – No threat of loose fibres into internal environment. ■ ■ Residential & Social Housing Manufacturing site quality approved to ISO 9001: 2008. ■ Utilities ■ Refurbishment ■ ■ Kingspan provide a project specific customer service that includes model specifications, construction details and load span calculations. For further information, please contact Kingspan. 5 Joint Details Rooflights and Penetrations Sealing Décor Standing Seam Kingspan K-Dek offers the Décor profile – a weld on aesthetic standing seam that can be used to produce a lead roof effect on visible roof areas. Penetrations Kingspan K-Dek easily accommodates a range of penetrations such as roof platforms, ventilation units and rooflight systems. Drainage Options Kingspan K-Dek is compatible with standard gravity and syphonic drainage systems. 6 Connectivity to Structure System Overview Roof Shape & Form Options Curved (40m radius) Mono-pitch Low Pitch (0.72°) Roof Platforms Drainage Options 7 Kingspan EnvelopeFirst™ Today, the demand for energy efficient buildings is greater than ever before, driven by mandatory legislation and escalating energy costs – forecast to double by 2030. Kingspan offers a wide range of building envelope systems that can provide significant performance benefits towards the overall energy efficiency of a building and the optimum specification, size and amount of HVAC equipment – the largest end use of energy and source of GHG emissions in commercial buildings. With EnvelopeFirst™, heating and cooling energy demand can be reduced by up to 40% with smaller, less-costly more energy efficient HVAC systems. Rising to these challenges, Kingspan has developed EnvelopeFirst™. EnvelopeFirst™ is a design strategy for optimising a building’s energy efficiency and the first step on the route to Carbon Neutral Buildings, providing property investors, owners, landlords and tenants with affordable, energy efficient buildings. The next step, once the building envelope is as efficient as possible, is the implementation of optimised HVAC and building services. Finally, the integration of renewable technologies enables a building to achieve carbon neutral targets, and even become a net-energy producer. The most effective, and affordable, energy saving measure available to a building is the integration of a high performance building envelope system that provides guaranteed insulation continuity and thermal and airtightness performance. Leisure Commercial Office Hotel Industrial BCA BCA Compliant EnvelopeFirst™ Kingspan insulated panels to BCA plus standard efficiency HVAC. Kingspan insulated panels to BCA plus optimised HVAC. 8 “Building insulation is the most cost-effective solution to reduce energy and greenhouse gases.”* Whole Building Design A building’s envelope, services and renewables must be considered on a ‘whole building design’ basis in order to optimise energy performance to achieve efficiency and sustainability targets. The design, construction and/or retrofitting of high-performance low- and carbon neutral buildings demands an integrated, ‘whole building design’ (WBD) approach. In comparison to an elemental design and construction processes, WBD examines the integration of all building components, systems and equipment to determine how they work together to save energy and reduce the buildings overall impact on the environment. WBD considers all impacts and influences associated with a building: site, orientation, energy, materials, acoustics, indoor air quality, and natural resources. Education Residential Distribution Retail “Energy efficient buildings start with Kingspan EnvelopeFirst™ ” -CO2 Insulate & Generate Carbon Neutral Buildings Kingspan insulated panels to BCA, optimised HVAC plus integrated solar PV solutions. ‘Insulate & Generate’ specification plus additional carbon offsets to achieve operational carbon neutrality. * Source: McKinsey Global Institute 9 Product Data Application Panel Properties and Thermal Performance Kingspan K-Dek can be used on building applications with a minimum finished roof pitch after deflection of 1:80 (0.72˚) to avoid ponding. It is suitable for all building applications except where there are low temperature controlled or high humidity environments. A - Core Thickness (mm) 100 B - Overall Dimension (mm) 135 R Value (m2K/W) 5.27 U Value (W/m2K) 0.19 Weight kg/m2 0.5 steel 9.00 Product Dimensions 60 External single-ply membrane A B Internal liner sheet 27 30.4 30.4 333.3 30.9 333.3 333.3 1000mm cover width Note: Above dimensions are nominal. Actual dimensions will vary due to manufacturing tolerances. Precise dimensions must always be measured from actual samples. All dimensions in millimetres. Product Tolerances Acoustic Performance Cut to Length -0.05% +0.1% Liner Sheet Length -0.1% +0.1% Cover Width -0mm +3mm Thickness -2mm +2mm End Square -3mm +3mm Kingspan K-Dek has a single figure weighted sound reduction index (SRI) of Rw = 23dB. For specific acoustic solutions, please contact Kingspan Technical Services. Sound Reduction Index (SRI) Fire Performance When tested to AS/NZS 1530.3, Kingspan panels achieved the following fire hazard results: Ignitability index 0 Spread of flame index (SFI) 0 Heat involved index 0 Smoke development index (SDI) 2 Kingspan K-Dek (KS1000 KD) insulant core is an FM Global certified formulation. Steel liner has a Class 1 surface spread of flame to BS 476-7. 10 Frequency (Hz) 125 250 500 1k 2k 4k SRI (dB) 17.9 18.1 17.4 23.2 30.4 40.3 Product Data Materials and Coatings Quality and Durability Exterior Weather Sheet Sikaplan SGK AU is a high performance single ply membrane. Kingspan K-Dek roof panels are manufactured from the highest quality materials, using state-of-the-art production equipment to rigorous quality control standards. Accredited to ISO 9001: 2008 ensuring long-term reliability and service life. Standard colours are white or light grey. A wide range of Sika membranes are available, please contact Kingspan for further details. Warranty Kingspan K-Dek roof panels are available with up to 20 years thermal and structural performance warranty. For information relating to coating warranties contact Kingspan. Internal Liner Sheet The standard steel is 0.50mm thick Aluzinc G300S coated steel to AS1397. Other substrates are available. ■ ■ Finished paint coating is a standard white liner. Packing Other colours available are subject to minimum order quantities / surcharges and extended lead times. Standard Packing Kingspan K-Dek panels are stacked horizontally, liner sheet to liner sheet, to minimise pack height. The top, bottom and sides are protected with polythene foam or core flute and the pack is covered in shrink wrapping for added protection during transport. Insulation Core The core of the Kingspan K-Dek roof panel range is an environmentally sustainable Kingspan polyisocyanurate (PIR) insulation which is non-deleterious with zero Ozone Depletion Potential. The rigid PIR insulation is closed cell and CFC/HCFC-free. The number of panels in each pack depends on panel length and weight. Typical pack height is 1200mm (8 sheets). The auto adhesive properties of the core bond to the external and internal faces, providing strength and rigidity to the panels. Sea Freight Steel containers are used, with panel lengths up to 11.8m. Special loading charges apply. Available Lengths Delivery Standard lengths are from 2m to 13.7m, longer lengths can be supplied on request. Maximum length for panels transported by rail is 12m. For orders supplied outside of Australia, maximum length is 11.8m. All deliveries (unless indicated otherwise) are by flatbed road transport to project site. Off-loading is the responsibility of the client. 75mm Panel length 11 Product Data Structural – Load/Span Tables Single Span Condition Uniformly Distributed Loads (kN/m2) Span L in metres Load Type Ultimate Limit State 0.6 0.8 1.0 1.2 1.4 1.6 1.8 Pressure 14.96 8.36 5.31 3.65 2.64 2.00 1.55 One Fastener 6.22 4.69 3.78 3.16 2.48 1.92 1.53 Two Fasteners 12.34 7.37 4.74 3.33 2.48 1.92 1.53 Three Fasteners 13.01 7.37 4.74 3.33 2.48 1.92 1.53 Suction Servicability Limit State Pressure - 6.72 3.39 1.92 1.17 0.75 0.49 Suction - - 6.34 3.71 2.38 1.63 1.18 Double Span Condition Uniformly Distributed Loads (kN/m2) Span L in metres Load Type Ultimate Limit State 0.6 0.8 1.0 1.2 1.4 1.6 1.8 Pressure 8.70 5.48 3.75 2.73 2.06 1.61 1.28 One Fastener 2.55 1.94 1.57 1.33 1.16 1.02 0.92 Two Fasteners 5.00 3.78 3.04 2.55 2.20 1.94 1.74 Three Fasteners 7.45 5.61 4.51 3.78 2.87 2.22 1.77 Pressure - - 8.31 4.76 2.96 1.95 1.34 Suction - - - 8.79 5.58 3.77 2.68 Suction Servicability Limit State Notes: 1. Values have been calculated in accordance with AS/NZS 1170.0 accounting for imposed loads and creep. 2. Fastener calculations based upon minimum 1.2mm thick steel purlins, grade not less than G380. 3. The following deflection limits have been used: Downward loading L/250 L/ Suction loading 150 4. The table is based on a support width of 50mm. 5. The allowable steelwork tolerance between bearing planes of adjacent supports is +/- 5mm or L/600, whichever is greater. 6. Load /span tables for panel specifications not shown are available from Kingspn Technical Services. 12 Construction Details Side / End Lap & Fastener Locations Detail 1 - Side Lap Detail 2 - End Lap Site weld membrane overlap 75mm Path of self-coring single-fix fastener 200mm site welded membrane strip Main fixing Self-coring Fasteners ■ ■ ■ 30 Reduces installation time by up to 65%. Single operation – no coring out holes, no debris left on roof. Spiral washer on head cuts a helical path through insulation without removing core. ■ Washer automatically flattens when screw is driven home. ■ Light or heavy gauge available. ■ Fully tested and approved by Kingspan. Detail 3 - Fastener Locations Membrane disc 90mm Ø Note: The number of fasteners required is dependent on project specific wind loadings. Refer to load span tables for further information. 13 Construction Details Parapet Eaves PIR board insulation with gun applied fire rated canister insulation to fill any gaps if required to maintain continuity of insulation Membrane lined steel flashing Membrane disc Galvanised steel strip required if greater than 15mm gaps between panels Drip flashing Kingspan Trapezoidal insulated wall panel – vertically laid Membrane strip Membrane disc Air seal - 6x4 butyl tape Rainwater outlet Membrane lined steel flashing Canister insulation Kingspan K-Dek insulated roofdeck panel Internal upstand flashing with 75mm sealed overlaps PIR insulation board Galvanised steel ledger Fasteners at 330mm centres Main fixing Kingspan insulated Architectural Wall Panel – vertically laid Profile filler bedded gun grade sealant 0.7mm galvanised plate Fasteners 14 Membrane flashing Construction Details Eaves Boundary Gutter Drip flashing Membrane strip Membrane lined steel flashing Air seal – 6x4 butyl tape Parapet flashing with 150mm butt straps sealed with 6x4 butyl tape PIR insulation board or timber packer Kingspan insulated Architectural Wall Panel – vertically laid Air seal – 6x4 butyl tape Kingspan K-Dek insulated roofdeck panel Membrane strip Fasteners at 330mm centres Membrane lined steel flashing Membrane strip Drip flashing Membrane coated insulated boundary wall gutter Profile filler bedded gun grade sealant Main fixing Membrane disc 15 Construction Details Verge Start Kingspan verge flashing with 150mm sealed butt straps Membrane strip Membrane lined steel flashing Cleader angle by steel sub-contractor with air seal Membrane lined steel flashing 6x4 butyl tape Fasteners @ 330mm centres PIR insulation board or timber Membrane strip Site applied fire-rated canister insulation Kingspan K-Dek insulated roofdeck panel Continuous run of 6x4 butyl tape Galvanised cleader angle by steel sub-contractor Air seal - 6x4 butyl tape Kingspan K-Dek verge flashing or membrane lined steel flashing 6x4 butyl tape AWP filler sealed top and bottom with gun grade sealant Kingspan insulated Architectural Wall Panel – vertically laid 16 Construction Details Verge End Membrane lined steel flashing 6x4 butyl tape Fasteners @ 330mm centres PIR insulation board or timber Membrane strip Main fixing Kingspan K-Dek insulated roofdeck panel Continuous run of 6x4 butyl tape Galvanised cleader angle by steel sub-contractor Air seal - 6x4 butyl tape Kingspan K-Dek verge flashing or membrane lined steel flashing AWP filler sealed top and bottom with gun grade sealant Kingspan insulated Architectural Wall Panel – vertically laid 17 Construction Details Verge Parapet Standard termination flashing Membrane lined steel flashing Membrane strip Section A-A 5˚ min 6x4 butyl tape sealant prior to panel installation 0.5mm coil coated parapet flashing with 150mm sealed overlap Kingspan Trapezoidal insulated wall panel vertically laid with joint fully sealed prior to installation and backsealed once installed. Contact Kingspan Technical for further info. A A Continuous bead of silicone sealant Standard termination flashing Overseal once panel is installed Membrane lined steel flashing Site applied fire-rated canister insulation Main fixing Fasteners at 330mm centres Minimum extent of sealant required to panel joint - see section A-A Membrane strip Kingspan K-Dek insulated roofdeck panel Cantilever distance varies. Contact Kingspan Technical for further information Air seal - 6x4 butyl tape Galvanised steel cleader angle 18 Construction Details Ridge Membrane flashing Galvanised flashing Site applied fire-rated canister insulation to fill any gaps if required Membrane flashing 0.7mm galvanised plate with welted edges Fasteners @ 330mm centres Kingspan K-Dek insulated roofdeck panel Site applied fire-rated canister insulation Profile filler bedded on gun grade sealant Internal liner flashing with 75mm overlaps sealed with 6x4 butyl tape Main fixing 19 Construction Details Valley with Rainwater Outlet Membrane flashing Galvanised steel strip required if greater than 15mm gaps between panels Air seal - profile filler sealed top and bottom with gun-grade sealant Rainwater outlet Canister insulation Membrane disc Membrane flashing over 0.7mm galvanised plate Profile filler bedded on gun grade sealant Kingspan K-Dek insulated roofdeck panel Galvanised steel ledger Main Fixing Note: Depth of verge flashing with this detail to be designed to suit calculated water depth. 20 Construction Details Valley Gutter Membrane strip Air seal - Profile filler sealed top and bottom with gun-grade sealant Kingspan K-Dek insulated roofdeck panel Membrane strip Main fixing Profile filler bedded gun grade sealant Fasteners at 330mm centres Membrane lined steel flashing Membrane strip Membrane lined insulated valley gutter Membrane disc 21 Construction Details Concrete Parapet Mono Pitch, Concrete Parapet Continuous bead of silicone sealant Standard termination flashing Membrane lined steel flashing Precast concrete wall Membrane strip Kingspan K-Dek insulated roofdeck panel Site applied fire-rated canister insulation Site applied expanding foam tape Internal liner flashing Fasteners @ 330mm centres Main fixing Profile filler bedded on gun grade sealant Verge, Concrete Parapet Continuous bead of silicone sealant Standard termination flashing Membrane lined steel flashing Precast concrete wall Membrane strip Kingspan K-Dek insulated roofdeck panel Site applied fire-rated canister insulation Site applied expanding foam tape Internal liner flashing Main fixing Fasteners @ 330mm centres Air seal - 6x4mm butyl tape 22 Construction Details Barrel Vault Rooflights 75 PIR insulation board or timber 74 100 Fitted end caps Galvanised support channel with acute angle of 15˚ 40mm membrane weld 15˚ springing angle Membrane lined steel flashing Membrane flashing Kingspan K-Dek insulated roofdeck panel 23 Construction Details Kerb Penetration Roof Aperture PIR insulation board or timber Membrane lined steel flashing Slope Slope Membrane flashing Hot air weld Membrane Slope direction Tapered insulation watershed Galvanised support channel Self coring fastener Fastener @ 330mm centres 24 Construction Details Natural Daylighting Systems UV stabilised polycarbonate diamond top dome (by others) Galvanised flashing plate Collar Rivets at 300mm centres Membrane flashing Kingspan K-Dek insulated roofdeck panel Additional supports if above 300mm Ø Roof light extension length Adjustable elbow 25 Construction Details Ventilation & Extraction Ridge Ventilator Ventilator to be supplied and installed by specialist contractor Internal galvanised support PIR insulation board or timber Membrane flashing Membrane lined steel flashing Profile filler bedded on gun grade sealant Membrane flashing Fasteners @ 330mm centres Main fixing Extractor Flue Extractor flue Waterstop mastic behind clamp Clamp applied around (1) Membrane sleeve for cold temperature Extractorflues flue (2) Metal sleeve for hot temperature flues Membrane flashing welded to panel and clamped to pipe Internal cover flashing Kingspan K-Dek insulated roofdeck panel Canister insulation Additional supports if above 300mm Ø Notes: Height of exhaust pipe to be sufficient to prevent membrane panel being exposed to hot gases. Surface temperature of extractor flue must not exceed 80°C (can withstand 110°C for a short period of time). Should extractor flue exhaust high temperature gases / pollutants a suitable fire rated / non-combustible barrier gasket should be installed by specialist contractor. 26 Construction Details Expansion Joint Polyethylene rod Single ply membrane formed around polyethylene rod to allow expansion Canister insulation 50mm weld Air seal - 6x4 butyl tape Membrane flashing Kingspan K-Dek insulated roofdeck panel Internal liner flashing Purlin Rafter 27 Construction Details M&E Services Support Platform Section B-B Steel platform Mastic sealant Stainless steel jubilee clip Waterstop mastic Proprietary pipe seal RHS Hot air weld Rafter Plan Section A-A Mastic sealant Waterstop mastic Kingspan K-Dek insulated roofdeck panel Purlin Stainless steel jubilee clip Proprietary pipe seal RHS Hot air weld Roof slope 28 29 Kingspan K-Dek Fabrications Kingspan Supplied Profile filler Double sided acrylic tape Profile Filler Supplied in single 1 metre units. Used where the panel needs to be closed off for air and weather sealing. Double Sided Acrylic Tape The use of a double sided acrylic tape under the membrane overlap will keep the lap flat and in position while the welding process is carried out. Sika Supplied Pipe / Vent Flashing Prefabricated flashing for pipe and vent penetrations from 77mm to 167mm diameter. Corner Flashings Corner flashings are used to seal up-stand flashings and penetrations. Décor Profile The Décor profile is used to emulate the appearance of a standing seam metal roof and is available in various colours to match specific design needs. Décor profile can be heat welded directly onto finished roof membrane. Walkway Pad The 7mm thick walkway is durable, trafficable and is heat welded directly to the Kingspan K-Dek roofdeck panel. 30 Kingspan K-Dek Fabrications Sika Supplied Vertical Rainwater Outlets Rainwater outlets are through fixed to the liner sheet of the Kingspan K-Dek roofdeck panel. Outlets are available up to 160mm diameter. Turbine Leaf Guard Turbine Leaf Guard is a metal guard for vertical outlets used with the Kingspan K-Dek roofdeck panel. Parapet Outlet Used as an outlet through the parapet, available in 40mm to 90mm diameter. Parapet Overflow Used as an emergency overflow through the parapet. Sika Australia 55 Elizabeth Street, Wetherill Park, NSW 2164 t: (02) 9725 1700 f: (02) 9756 5001 e: [email protected] www.aus.sika.com 31 Height Safety Solutions Kingspan Safepro2 Fall Protection System Kingspan Safepro2 Fall Protection System 8mm cable supplied to specific lengths required Safepro2 roof anchor intermediate guide Safepro2 roof anchor membrane cap Safepro2 slider Safepro2 roof anchor intermediate module Membrane ‘boot’ bonded to roof Safepro2 roof anchor baseplate Kingspan K-Dek insulated roofdeck panel 4 No. Safepro2 roof anchor toggle fixings 32 Height Safety Solutions Kingspan Safepro2 Fall Protection System Kingspan Safepro2 is a new innovative fall protection system, designed to protect both the worker and the roof to which it is fixed. Kingspan Safepro2 is the only horizontal life line approved by Kingspan for installation on Kingspan insulated panels. Features & Benefits ■ Safepro2 comprises a high-strength stainless steel cable, supported on energy-absorbing roof anchor posts. Safepro2 is certified to AS NZS 1891.2 & 1891.4, EN 795 and OHSA 1926. ■ Safepro2 roof anchors incorporate Force Minimisation Technology, which limits the load transferred to the roof, in a fall arrest event, to less than 6kN. This is a significant improvement over older types of force control posts which applied 10kN or more to the roof. ■ Safepro2 has fixing and sealing details specifically for Kingspan K-Dek, Trapezoidal, Foilback and Lo-Pitch insulated panels. Safepro2 is the only such system tested and proven with current Kingspan insulated panel specifications. ■ ■ Safepro2 can be installed during or after construction to most roof systems, without access to the underside of the roof. Safepro2 is highly suitable for providing safe access to roof-mounted PV and other solar systems. ■ ■ The Kingspan Safepro2 system is available globally including Australia, New Zealand, United Kingdom, Ireland, Europe, North America and Canada, the Middle East and Hong Kong. ■ ■ 33 Compliance with national and international standards – providing the highest levels of protection and compliance with regulatory requirements. Approved by Kingspan and an integral part of the Kingspan insulated panel system – ensuring compatibility with roof system and not affecting roof guarantees. High-grade stainless steel and aluminium components – offering superior corrosion resistance, durability and service life. Improved energy absorbency of anchor posts, reduces loads generated during fall arrest event – requiring fewer fixings and reducing potential damage to roof panels. Advanced fixings design – allowing efficient installation without access to underside of roof. All fixings and accessories are supplied by Kingspan – guaranteeing correct and compatible materials are used. Located anywhere on roof – ensuring most practicable solutions can be offered for each roof. Highly-evolved design – offering one of the simplest to design, most efficient to install and easiest to use systems available. Technical support is available directly from Kingspan – allowing designers, installers and users to maximise the potential of these systems. Model Specification Product: Kingspan K-Dek (KS1000 KD) Application The following specification is for the KS1000 KD insulated membrane roof panel used on buildings with a flat, pitched or curved roof construction. Finished pitch: minimum 1:80 (0.72°) or more after deflection to avoid ponding. Acoustics For sound transmission reduction, Kingspan K-Dek has a single figure weighted sound reduction index (SRI) of Rw = 23dB. For specific acoustic solutions contact Kingspan Technical Services. Materials and Coatings Sound Reduction Index (SRI) External Weather Sheet Sikaplan SGK AU membrane. Colour to be white. Frequency (Hz) 125 250 500 1k 2k 4k SRI (dB) 17.9 18.1 17.4 23.2 30.4 40.3 Insulation Core To consist of 100mm, closed cell, zero ozone depleting potential (ODP), Factory Mutual certified polyisocyanurate (PIR) insulation. Seals and Fillers End Lap 200mm membrane strip welded at lap. Nominal weld 40mm to each panel. The auto adhesive properties of the core bond to the external and internal sheets to provide strength and rigidity to the panels. Side Lap Double sided acrylic tape applied to side lap prior to welding (Kingspan reference KDSLTAPE). Overlap of membrane welded to membrane of adjacent panel at side laps, nominally 40mm. Internal Liner Sheet Substrate to be a minimum 0.5mm thick G300S AZ100 coated steel to AS1397. Colour to be Kingspan Bright White. Warranty Fillers Polyethylene profiled fillers should be used to seal perimeter of building (Kingspan reference 3RWFILL). Seal the top, bottom and sides of each profile filler with a single line of non-setting gun-grade sealant. Kingspan Insulated Panels will provide up to 20 year warranty on the project upon completion. The panel must be installed as per Kingspan’s recommended construction details and the contractor trained by Kingspan’s field service manager. Project is to be inspected prior to warranty being issued. Locate where shown on drawings and wherever necessary to close off corrugation cavities from the inside and outside of the building. Ensure a tight fit and leave no gaps. Performance Thermal Insulation Panels will have a Thermal Resistance of 5.27 m2K/W based on an aged thermal conductivity of 0.020 W/mK. Junctions Junctions between the roof panel system and walls / penetrations to be filled with a fire rated gun applied canister urethane insulation. Fire When tested to AS/NZS 1530.3, Kingspan panels achieved the following fire hazard results: Ignitability index 0 Spread of flame index (SFI) 0 Heat involved index 0 Smoke development index (SDI) 2 Fasteners Primary Self-coring carbon steel fasteners to be used incorporating a 19mm washer. Recommended fixing manufacturer SFS Intec (sourced from Powers Fasteners). SFS fastener codes:. Kingspan K-Dek (KS1000 KD) insulant core is an FM Global certified formulation. Steel liner has a Class 1 surface spread of flame to BS 476-7. ■ 1.2 – 3.0mm steel purlin ■ 3.0 – 12.0mm steel purlin SD14-D10-T19/C9-5.5x40 ■ Timber SW2-D10-T19/C9-5.5x55 SD3-D10-T19/C9-5.5x30 A minimum of three fasteners is required at panel ends and a minimum of one at intermediate support locations. The actual number of fasteners required is dependent on the project wind loads, see Kingspan K-Dek load/span table for further information. Intermediate fasteners covered with a 90mm welded membrane patch. 34 Model Specification Product: Kingspan K-Dek (KS1000 KD) Construction Requirements Secondary Fasteners for flashing installation to be flat head SFS IR2-C or similar at 330mm centres. Fastener length to be minimum 120mm for pan fixing and 155mm for crown fixing. Steelwork Tolerance The supporting frame must be made and assembled to an accuracy of +/- 5mm or L/600 (whichever is greater) between bearing planes of adjacent supports, where L is the purlin spacing. Construction Details Installation Panels to be laid with side lap joints away from prevailing wind unless otherwise shown on drawings. Flashings External flashings to be a combination of galvanised steel with membrane flashing overlay and membrane lined steel flashings, as per Kingspan standard construction details. Membrane lined steel flashings to be sealed at laps with a minimum 125mm welded membrane strip. All fasteners, seals and fillers to be of correct specification and installed as indicated on the project construction drawings. Site cut panels must provide accurate, true lines with no distortion. Internal flashings should be made to the same specification as the liner sheet. Flashings to be air sealed at laps and along the full length by an unbroken bead of 6x4mm butyl rubber sealant tape (Kingspan reference SEXT). Panels to be cut with a suitable metal cutting circular type saw and all exposed site steel to be treated with a suitable edge protection lacquer. Cut openings for outlets, vents, flues etc. to be the minimum size necessary. Penetrations larger than 300mm x 300m should have additional structural support. Rooflights Rooflights can be integrated into the membrane finish (refer to Kinspan details). Remove all swarf and any foreign matter immediately from the external surface of panels. Safety The contractor is to determine and use a safe method of working throughout the installation and construction period, which complies with OHS/WHS requirements. A safe work method template (although NOT project specific) is available from Kingspan. Drainage and Accessories A number of drainage and accessory options are available specifically designed to suit the Kingspan K-Dek roof system. These include pipe/vent flashings, drainage outlets incorporating leaf guards, overflow outlets, walkway systems and height safety solutions. Protection of Finished Roof Ensure that: Panel Lengths Standard lengths are from 2m to 13.7m, longer lengths can be supplied on request. Maximum length for panels transported by rail is 12m. For orders supplied outside of Australia maximum lengths are 11.8m. ■ ■ Exact lengths to be determined by the cladding contractor from the steelwork drawings. Finished roof areas are protected from damage by subsequent building operations. Paint, solvent, bitumen, oils, fat, grease or other substance harmful to the membrane do not come into contact with the roof surface. Do not: ■ Purlin Centres Purlin spacing determined from Kingspan load tables to project specific wind requirements, as specified by the structural engineer. ■ 35 Store building materials on the roof. Permit the use of the roof as a working platform without adequate protection of the roof surface. 90mm diameter patch cut from membrane roll to cover intermediate fastener (when required) Panel 4 Primary panel fasteners (hidden under membrane flap) Panel 2 Kingspan K-Dek panel Self-coring fasteners in each corrugation Kingspan K-Dek panel (left to right when viewed from eaves/valley) Note: Sequence of lay – Panel 1 to Panel 4 Self-coring fasteners in each corrugation Fully sealed filler at all panel ends (eaves, valley, ridge) Quality Assurance Kingspan is dedicated to maintaining its good reputation and is promoting this via their quality assurance of all membrane panels / products. By utilising EFVM® (Electric Field Vector Mapping) Technology provided by International Leak Detection, Kingspan recommends EFVM® testing of all Kingspan K-Dek installations. www.ild-australia.com.au / www.ildnz.co.nz 36 Installation Overview Installation Training Membrane end lap strip over end lap joints Kingspan Field Service Engineers offer full installation training however, prior to Kingspan K-Dek training, all attendees must have undergone welding training from the supplying membrane manufacturer and provide a copy of the certificate from the supplier. Panel 3 Double sided acrylic tape under membrane overlap 40mm min. welded seam Panel 1 Site applied air seal - 6mm diameter gun grade sealant at panel side joint in line with profiled filler block air seal Kingspan membrane lined insulated gutter 37 Case Studies Project Location Product Architect Building use Porsche Centre Porsche Centre Chester, UK Kingspan K-Dek KS1000 KD MDG Ltd Retail 38 Case Studies Project Location Product Architect Building use Captain’s Club Hotel Captain’s Club Hotel Christchurch, Dorset, UK Kingspan K-Dek KS1000 KD Cube Design Hotel & Leisure 39 Case Studies Project Location Product Architect Building use Matford Land Rover Land Rover Dealership Exeter, UK Kingspan K-Dek KS1000 KD Lilly Lewarne Practice Retail 40 Case Studies Project Location Product Building use Ibis Hotel Ibis Hotel Carlisle, UK Kingspan K-Dek KS1000 KD with Décor aesthetic standing seam option Hotel / Leisure 41 Insulated Roof & Wall Panels Product Range at a Glance Insulated Roof Panels Trapezoidal - KS1000 RW Roof pitches 4° and above. (For lower pitches contact Kingspan Technical Support). Lo-Pitch - KS1000 LP* Roof pitches 1.5° and above. Kingspan K-Dek - KS1000 KD Roof pitches 0.72° and above. Single-ply membrane roofdeck. Foilback - KS1000 FB Roof pitches 4° and above. With reflective foil liner. Polycarb Rooflight - KS1000 Polycarb Roof pitches 4° and above. (For lower pitches contact Kingspan Technical Support). Roof Mounted PV System Solar Photovoltaic Solution. * UK manufacture. 42 Insulated Roof & Wall Panels Product Range at a Glance Insulated Wall Panels (horizontally or vertically laid) Trapezoidal - KS1000 RW Euro-Box - KS1000 EB Architectural Wall Panel. Wave - KS1000 WV Architectural Wall Panel. Plank - KS1000 PL Architectural Wall Panel. Micro-Rib - KS1000 MR Architectural Wall Panel. Mini-Micro - KS1000 MM Architectural Wall Panel. Controlled Environment Panels Flat - KS1100 CS Wall & ceiling panel. Rib - KS1100 CS Wall & ceiling panel. All Kingspan panels are manufactured to order with varying core thicknesses depending on the spanning and thermal requirements of the project. Kingspan roof and wall panels are available in a wide range of colours. 43 Australia: Kingspan Insulated Panels Pty Ltd 38-52 Dunheved Circuit, St Marys, NSW 2760 Australia t: +61 (02) 8889 3000 f: +61 (02) 8889 3099 e: [email protected] www.kingspanpanels.com.au South East Asia: Kingspan Insulated Panels 1 Fullerton Road #02-01, One Fullerton, Singapore 049213, Singapore t: +65 6832 5021 f: +65 6408 3801 e: [email protected] www.kingspanpanels.asia Care has been taken to ensure that the contents of this publication are accurate, but Kingspan Insulated Panels Pty Ltd and its subsidiary companies do not accept responsibility for errors or for information that is found to be misleading. Suggestions for, or descriptions of, the end use or application of products or methods of working are for information only and Kingspan Insulated Panels Pty Ltd and its subsidiaries accept no liability in respect thereof. 04/2013
© Copyright 2026 Paperzz