Technical Product Specifications - Template

OMNIstar
Technical Product Specifications
Table of contents
1.
General Specifications ............................................................................................................. 3
2.
Photometry .............................................................................................................................. 4
3.
Mechanics ................................................................................................................................ 5
4.
Electrical Characteristics ......................................................................................................... 7
5.
Power Supply ........................................................................................................................... 7
6.
Environment ............................................................................................................................ 7
Page | 2
1.General Specifications
Product Description
The OMNIstar is a multi-purpose high power modular
LED luminaire solution designed to provide an unrivalled
combination of performance and flexibility for lighting
areas where high lumen packages are needed while
offering maximum savings in energy and maintenance
costs with a short payback time. This modular luminaire
can be installed on high masts with a bracket of one, two
or three luminaires to provide the lighting distribution
and lumen package needed to meet the specifications of
the area to be lit. Add flexibility with on-site photometric
adjustment, the OMNIstar guarantees the perfect
lighting to ensure safety and comfort. It offers a real
alternative to luminaires equipped with high-power
traditional light sources, with the added advantages of an
LED solution: low energy consumption, improved
visibility with white light, limited maintenance and longer
life. The OMNIstar can be fitted with the Owlet range of
control solutions to enable you to further maximize
energy savings by adapting the light levels according to
the real needs. A wide range of photometry is available.
The LensoFlex® photometric engine allows flexibility of
multiple light distributions to ensure that the specific
requirements of each application are met.
Other optics used are collimator for typical symmetrical
floodlight distributions and reflectors for asymmetrical or
symmetrical distributions.
ThermiX®: The OMNIstar offers an efficient thermal
management of both the LEDs and the power supply
thanks to the separation between the optical unit and
the gear box. The cooling fins on the optical unit optimize
the heat dissipation. This design enables the OMNIstar to
perfectly manage high ambient temperatures (Ta up to
55°C) and ensures reliability in the long term.
The luminaire housing is manufactured of high-pressure
die-cast aluminum.
It is designed for LED light sources between 322W and
470W


Main applications




Recommended mounting height
Page | 3
Industrial Areas - Highbay Industrial Warehouses
Indoor Sports: Swimming pools, Gymnasium,
Action Cricket, Soccer and Netball venues
Outdoor Sport : Tennis Courts, Hockey Fields
Transport hubs (airport aprons, harbours, bus
stations and train stations)
Streetlighting - large highway intersections, toll
plazas
Area Lighting
8 - 40m
Photometry
Light source
LED
LED
2mm2 or 4mm2 LED
Colour Temperature
Neutral White (4000K)
Colour rendering (Ra)
≥70
LEDs / Wattage
144 LED @ 700ma 322W
to
144LEDs @1000ma 461W
Lumen Package
40781lm
Optics
Collimators* : 5125, 5126, 5127 and 5128
Reflectors Asymmetrical : 2258, 2266, 2261, 2260 and 2259
Reflectors Symmetrical : 2261, 2260 and 2259
LensoFlex® : 5068, 5118, 5119*, 5120* and 5121*
to
61681lm
*Not available for high lumen output version
Photometry:
Page | 4
Lifetime residual flux Tq 250C
OVERVIEW
LAMP HOLDER
Number of LEDs
Neutral white (4000K)
Current 700mA (3)
Current 1000mA
(4)
Nominal Flux (lm) (1)
40781
Power Consumption (W)
100.000h
90%
322
Nominal Flux (lm) (1)
50688
Power Consumption (W)
Nominal Flux (lm)
Current 1000mA (4)
144 LEDs
470
(1)
61681(5)
60.000h
80%
461 (5)
Power Consumption (W)
(1) The nominal flux is an indicative LED flux @ Tj 25°C based on LED manufacturer’s data. The real flux output of the
luminaire depends on environmental conditions (e.g. temperature and pollution) and the optical efficiency of luminaire.
Nominal flux depends on the type of LED in use and likely to change in accordance with the continuous and rapid
developments in LED technology. To follow the progress of the luminous efficiency of the LEDs used, please visit our website.
(2) In accordance with IES LM-80 – TM-21
(3) Ta = 35˚C max outdoor and indoor
(4) Ta= 30˚C max outdoor, 25˚C indoor
(5) Refer to High Lumen Output section in the Ordering Data table.
2.Mechanics
Electronic control Gear
Constant Current Driver
Materials and finishing
Housing – High quality high-pressure die-cast aluminum
(EN 1706 AC-47100)
Protector – High Impact Clear Glass
Finish
Standard Pearl Light Grey (RAL 9022)Textured finish
Optional : Any other RAL colour available on request
Installation
Stirrup or Suspended versions
Fixing
2 x ø 8mm bolts (standard version)
4 x ø 6mm eyebolts (suspended version)
Dimensions in mm (L x W x H)
530 * 530 *80 (Optical Block)
Weight (with gear)
Up to 19.6kg (excludes gear)
Access
Yes
Aerodynamic resistance
0.168m2
Page | 5
Page | 6
3.Electrical Characteristics
Line Voltage
230VAC
Mains voltage Tolerance (AC)
108-305V
Line frequency
50Hz
Electrical Safety Class (IEC)
Class I or II
Surge protection
Yes
- 10kV/10kA
Optional
- 20kV/20kA
Optional
- OWLET Remote Management
Lighting control
4.Power Supply
Power Factor
≥0.95
Removable
Yes
Thermal Safety
Yes
5.Environment
Storage temperature
- 400C to +600C
Operating temperature (Ta)
- 400C to + 350C
Enclosure Tightness
IP 66
Enclosure Mechanical Withstand Impact
IK08

* Certified Test Standard SANS IEC 60598 -2-3 (available on request)
Page | 7
Updated By :
Approved by
Nadja Smith
Daniel Kasper
(1)
For specific Tq, Ta and life time data, contact BEKA Schréder
Page | 8
Document Revision / Date
28/02/2017