PIT es Set/1 Control and signal devices Operating Manual1002542EN05 Preface This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions and comments for improving this documentation will be gratefully received. Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS®, SafetyBUS p®, SafetyEYE®, SafetyNET p®, the spirit of safety® are registered and protected trademarks of Pilz GmbH & Co. KG in some countries. SD means Secure Digital Content Introduction Validity of documentation Using the documentation Definition of symbols 5 5 5 5 Safety Intended use Safety regulations Safety assessment Use of qualified personnel Warranty and liability Disposal For your safety 6 6 6 6 7 7 7 7 Unit features 7 Function description 8 Installation 8 Preparing for operation 10 Dimensions 13 Technical Details Order No. 400430400432 20 Technical Details Order No. 400433400435 21 Technical Details Order No. 400436400438 22 Technical Details Order No. 400439400442 23 Technical Details Order No. 400443400445 24 Technical Details Order No. 400446400448 25 Technical Details Order No. 400449400451 26 Technical Details Order No. 400452400454 27 Technical Details Order No. 400455400458 28 Technical Details Order No. 400459 29 Safety characteristic data 29 Order reference 30 Operating Manual PIT es Set/1 1002542EN05 3 Content Product Accessories 30 31 EC declaration of conformity 32 Operating Manual PIT es Set/1 1002542EN05 4 PIT es Set/1 Introduction Validity of documentation This documentation is valid for the product PIT es Set/1. It is valid until new documentation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product. Using the documentation This document is intended for instruction. Only install and commission the product if you have read and understood this document. The document should be retained for future ref erence. Definition of symbols Information that is particularly important is identified as follows: DANGER! This warning must be heeded! It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates preventive measures that can be taken. WARNING! This warning must be heeded! It warns of a hazardous situation that could lead to serious injury and death and indicates preventive measures that can be taken. CAUTION! This refers to a hazard that can lead to a less serious or minor injury plus material damage, and also provides information on preventive measures that can be taken. NOTICE This describes a situation in which the product or devices could be dam aged and also provides information on preventive measures that can be taken. It also highlights areas within the text that are of particular import ance. Operating Manual PIT es Set/1 1002542EN05 5 PIT es Set/1 INFORMATION This gives advice on applications and provides information on special fea tures. Safety Intended use The emergency stop device consists of an ESTOP pushbutton and a contact block. It is in tended for use in safety circuits in accordance with IEC/EN 6094751, IEC/EN 6094755, EN 602041, EN ISO 138491. Before using the device, a safety assessment of the overall system must be performed in accordance with the Machinery Directive. CAUTION! It must not be possible to defeat the ESTOP pushbuttons, otherwise mater ial damage and severe injuries may result, depending on the application. The ESTOP pushbutton may not be used in place of other safety meas ures. The following is deemed improper use in particular: } Any component, technical or electrical modification to the product } Use of the product outside the areas described in this manual } Use of the product outside the technical details (see chapter entitled "Technical De tails"). Safety regulations Safety assessment Before using a unit it is necessary to perform a safety assessment in accordance with the Machinery Directive. Functional safety is guaranteed for the product as a single component. However, this does not guarantee the functional safety of the overall plant/machine. In order to achieve the re quired safety level for the overall plant/machine, define the safety requirements for the plant/machine and then define how these must be implemented from a technical and organ isational standpoint. Operating Manual PIT es Set/1 1002542EN05 6 PIT es Set/1 Use of qualified personnel The products may only be assembled, installed, programmed, commissioned, operated, maintained and decommissioned by competent persons. A competent person is someone who, because of their training, experience and current pro fessional activity, has the specialist knowledge required to test, assess and operate the work equipment, devices, systems, plant and machinery in accordance with the general standards and guidelines for safety technology. It is the company’s responsibility only to employ personnel who: } Are familiar with the basic regulations concerning health and safety / accident preven tion } Have read and understood the information provided in this description under "Safety" } And have a good knowledge of the generic and specialist standards applicable to the specific application. Warranty and liability All claims to warranty and liability will be rendered invalid if } The product was used contrary to the purpose for which it is intended } Damage can be attributed to not having followed the guidelines in the manual } Operating personnel are not suitably qualified } Any type of modification has been made (e.g. exchanging components on the PCB boards, soldering work etc.). Disposal } In safetyrelated applications, please comply with the mission time TM in the safetyre lated characteristic data. } When decommissioning, please comply with local regulations regarding the disposal of electronic devices (e.g. Electrical and Electronic Equipment Act). For your safety The unit meets all the necessary conditions for safe operation. However, please note the following: } Check the function of the pushbutton before commissioning for the first time and then at regular intervals (at least annually). Unit features The emergency stop device consists of an ESTOP pushbutton PIT es/1 and a contact block PIT esc/1. Various types are available; these can be ordered as sets or can be put to gether as modular assemblies. Features: } Panel mount version or surface mount version with twopart surface mount housing } Turn in either direction to release or turn right for key release } Various mushroomtype pushbuttons – Operating Manual PIT es Set/1 1002542EN05 Standard mushroomtype pushbutton 7 PIT es Set/1 – Mushroomtype pushbutton with keyrelease – Illuminated mushroomtype pushbutton – Mushroomtype pushbutton for hygiene critical areas in accordance with DIN EN 16722 – Mushroomtype pushbutton with inscribed ESTOP symbol } Contact blocks for applications up to PL e of EN ISO 138491 and SIL CL 3 of EN IEC 62061 } Connected to contact blocks via springloaded terminal (quick connection), screw con nection or M12 connector Function description The emergency stop device is used to shut down plant and machine sections in order to re duce or avert imminent or existing hazards to persons and damage to machinery or materi als. Installation CAUTION! The emergency stop device should always be installed with the supply voltage switched off. Panel mount version NOTICE Particularly in hygiene areas, use mounting plates with a smooth surface to ensure a tight seal. } Prepare a cutout (Ø 22.3 mm) in the mounting plate. } With illuminated ESTOP pushbuttons: Prepare another opening in the mounting plate for the lighting connection } Guide the ESTOP pushbutton into the mounting plate opening and secure it using the plastic nut (size 24 spanner). Note the max. torque setting of 1.2 Nm. } Connect the contact block to the neck of the ESTOP pushbutton and secure it by turn ing it to the right. Operating Manual PIT es Set/1 1002542EN05 8 PIT es Set/1 9,0 19,50 2,20 22 22 ,3 0 ,3 0 2,20 0 Surface mount housing [3] [4] [1] [2] [5] Legend: [1]: ESTOP pushbutton [2]: Upper part of the surface mount housing [3]: Plastic nut [4]: Contact block [5]: Lower part of the surface mount housing } With illuminated ESTOP pushbuttons: – Drill through one of the holes indicated on the upper part of the surface mount housing. – Attach the contact block to the bracket. – Guide the cable through the opening in the upper part of the surface mount housing and connect it to the ESTOP pushbutton. } If an M12 connector is not fitted, break out the stuffing box connection on the lower part of the surface mount housing. } Use two screws to attach the lower part of the surface mount housing. Operating Manual PIT es Set/1 1002542EN05 9 PIT es Set/1 } After connecting the wiring to the contact block: Screw the upper part of the surface mount housing to the lower part. Preparing for operation Please note the following when connecting the wiring to the contact blocks: With PIT es Set/1, the contact blocks are supplied preassembled in a bracket. With illumin ated ESTOP pushbuttons, the contact block must be attached to the bracket. NOTICE Check the function of the emergency stop device before commissioning for the first time and then at regular intervals (at least annually). On devices with springloaded terminals, we recommend cables with crimp connections and a cable cross section of } Max. 0.5 mm² for devices with order no. 400451 and 400456 } Max. 2.5 mm² for all other devices. Wiring devices with surface mount housing: } With illuminated ESTOP pushbuttons: Break out one of the openings indicated on the upper part of the surface mount housing. } To route the cable, break out one of the preprepared openings on the lower part of the surface mount housing. } Use a plastic M20 stuffing box for sealing and strain relief (a stuffing box is included with PIT es Set6.5cr). Make sure that the contact blocks which are installed in the en closure are properly connected, so that when the unit is used correctly the require ments with regard to airgap creepage are satisfied for an enclosure with protective insu lation. NOTICE Please note the following when dismantling and reconnecting the individual contact blocks: The slides of the outer contact blocks must be pointing in wards, so that all of the slides are within the ring when the bracket is at tached (see Fig. 3). Operating Manual PIT es Set/1 1002542EN05 10 PIT es Set/1 Assignment of contact blocks PIT esc1, PIT esc1c PIT esc2, PIT esc2c PIT esc3, PIT esc3c PIT esc4 2 2 3 1 1 1 1 1 1 4 2 2 2 2 PIT es Set6.5cr Illuminated ESTOP PIT esc6c PIT esc8c 11 21 X1 2 3 2 3 1 12 22 X2 1 4 1 4 2 Operating Manual PIT es Set/1 1002542EN05 11 PIT es Set/1 Assignment of the 5pin M12 male connector 4 3 5 2 1 PIN Function 1 Input, channel 1 2 Output, channel1 3 0 V UB 4 Output, channel2 5 Input, channel 2 } Connection diagram with illumination 1 2 } 5 3 4 Connection diagram without illumination Operating Manual PIT es Set/1 1002542EN05 1 5 2 4 12 PIT es Set/1 Dimensions ESTOP pushbutton (PIT es1s, PIT es1u) 55,00 19,35 41,50 31,50 ESTOP pushbutton with keyrelease (PIT es8s, PIT es8u) 55,00 41,50 19,35 60,00 31,50 Operating Manual PIT es Set/1 1002542EN05 13 PIT es Set/1 Large ESTOP pushbutton (68 mm) (PIT es 2s, PIT es2u) ESTOP pushbutton with illumination (PIT es3s, PIT es3u) ESTOP pushbutton with illuminated protective collar (PIT es4s, PIT es4u) Cable approx. 10 cm black red red black Operating Manual PIT es Set/1 1002542EN05 Cable approx. 10 cm 14 PIT es Set/1 ESTOP pushbutton for hygiene critical areas (PIT es7u) 19,35 41,50 31,50 37,00 ESTOP pushbutton with protective collar (PIT es5s, PIT es5u) 67,00 Operating Manual PIT es Set/1 1002542EN05 19,35 1...7 42,50 31,55 15 PIT es Set/1 ESTOP pushbutton without protective collar (PIT es9u) 39,00 Operating Manual PIT es Set/1 1002542EN05 4,2 34,50 0 59,00 27,00 27,00 Surface mount version with ESTOP pushbutton 16 PIT es Set/1 Surface mount version, profile rail, with ESTOP pushbutton (PIT es Set6u5 nr, PIT es Set6u5 cr) PIT es6.12 Operating Manual PIT es Set/1 1002542EN05 17 PIT es Set/1 PIT es6.11 PIT esb6.7 PIT esb6.7 PCB Operating Manual PIT es Set/1 1002542EN05 18 PIT es Set/1 Panel mount version with ESTOP pushbutton 55,00 41,50 31,50 45,30 43,60 27,00 37,00 Operating Manual PIT es Set/1 1002542EN05 19 PIT es Set/1 Technical Details Order No. 400430400432 General Approvals Electrical data Volume resistance Min. contact current Relay outputs Utilisation category In accordance with the standard 400430 CE 400430 100 mOhm 1,00 mA 400430 400431 CE 400431 100 mOhm 5,00 mA 400431 400432 CE 400432 100 mOhm 1,00 mA 400432 EN 6094751 EN 6094751 EN 6094751 AC15 at Max. current DC13 (6 cycles/min) at Max. current Conventional thermal cur rent Contact material Times Bounce time Environmental data Ambient temperature Temperature range Storage temperature Temperature range Rated insulation voltage Protection type Housing Mechanical data Mounting position Mechanical life Connection type Dimensions Height Width Weight 250 V 3,0 A 24 V 2,0 A 250 V 3,0 A 24 V 2,0 A 250 V 3,0 A 24 V 2,0 A 16,0 A AgNi 400430 10 ms 400430 10,0 A AgNi 400431 10 ms 400431 16,0 A AgNi 400432 10 ms 400432 30 70 °C 25 55 °C 30 70 °C 50 85 °C 250 V 50 85 °C 250 V 50 85 °C 250 V IP65 400430 Any 20,000 cycles Screw terminal IP65 400431 Any 50,000 cycles Springloaded terminal IP65 400432 Any 20,000 cycles Screw terminal 100,0 mm 55,0 mm 54 g 92,0 mm 55,0 mm 51 g 100,0 mm 55,0 mm 66 g Where standards are undated, the 201305 latest editions shall apply. Operating Manual PIT es Set/1 1002542EN05 20 PIT es Set/1 Technical Details Order No. 400433400435 General Approvals Electrical data Volume resistance Min. contact current Relay outputs Utilisation category In accordance with the standard 400433 CE 400433 100 mOhm 5,00 mA 400433 400434 CE 400434 100 mOhm 1,00 mA 400434 400435 CE 400435 100 mOhm 5,00 mA 400435 EN 6094751 EN 6094751 EN 6094751 AC15 at Max. current DC13 (6 cycles/min) at Max. current Conventional thermal cur rent Contact material Times Bounce time Environmental data Ambient temperature Temperature range Storage temperature Temperature range Rated insulation voltage Protection type Housing Mechanical data Mounting position Mechanical life Connection type Dimensions Height Width Weight 250 V 3,0 A 24 V 2,0 A 250 V 3,0 A 24 V 2,0 A 250 V 3,0 A 24 V 2,0 A 10,0 A AgNi 400433 10 ms 400433 16,0 A AgNi 400434 10 ms 400434 10,0 A AgNi 400435 10 ms 400435 25 55 °C 30 70 °C 25 55 °C 50 85 °C 250 V 50 85 °C 250 V 50 85 °C 250 V IP65 400433 Any 50,000 cycles Springloaded terminal IP65 400434 Any 20,000 cycles Screw terminal IP65 400435 Any 50,000 cycles Springloaded terminal 92,0 mm 55,0 mm 60 g 87,0 mm 74,0 mm 74 g 92,0 mm 68,0 mm 67 g Where standards are undated, the 201305 latest editions shall apply. Operating Manual PIT es Set/1 1002542EN05 21 PIT es Set/1 Technical Details Order No. 400436400438 General Approvals Electrical data Supply voltage Voltage Kind Max. inrush current at UB Volume resistance Min. contact current Inputs Input current range Relay outputs Utilisation category In accordance with the standard 400436 CE 400436 400437 CE 400437 400438 CE 400438 12,0 30,0 V AC/DC 44,00 mA 100 mOhm 1,00 mA 400436 15,0 mA 400436 12,0 30,0 V AC/DC 44,00 mA 100 mOhm 5,00 mA 400437 15,0 mA 400437 – – – 100 mOhm 1,00 mA 400438 – 400438 EN 6094751 EN 6094751 EN 6094751 AC15 at Max. current DC13 (6 cycles/min) at Max. current Conventional thermal cur rent Contact material Times Bounce time Environmental data Ambient temperature Temperature range Storage temperature Temperature range Rated insulation voltage Protection type Housing Mechanical data Mounting position Mechanical life Connection type Dimensions Height Width Weight 250 V 3,0 A 24 V 2,0 A 250 V 3,0 A 24 V 2,0 A 250 V 3,0 A 24 V 2,0 A 16,0 A AgNi 400436 10 ms 400436 10,0 A AgNi 400437 10 ms 400437 16,0 A AgNi 400438 10 ms 400438 25 55 °C 25 55 °C 30 70 °C 25 80 °C 250 V 25 80 °C 250 V 50 85 °C 250 V IP65 400436 Any 20,000 cycles Screw terminal IP65 400437 Any 50,000 cycles Springloaded terminal IP65 400438 Any 20,000 cycles Screw terminal 100,0 mm 55,0 mm 83 g 92,0 mm 56,0 mm 75 g 100,0 mm 68,0 mm 83 g Where standards are undated, the 201305 latest editions shall apply. Operating Manual PIT es Set/1 1002542EN05 22 PIT es Set/1 Technical Details Order No. 400439400442 General Approvals Electrical data Volume resistance Min. contact current Relay outputs Utilisation category In accordance with the standard 400439 CE 400439 100 mOhm 5,00 mA 400439 400441 CE 400441 100 mOhm 1,00 mA 400441 400442 CE 400442 100 mOhm 5,00 mA 400442 EN 6094751 EN 6094751 EN 6094751 AC15 at Max. current DC13 (6 cycles/min) at Max. current Conventional thermal cur rent Contact material Times Bounce time Environmental data Ambient temperature Temperature range Storage temperature Temperature range Rated insulation voltage Protection type Housing Mechanical data Mounting position Mechanical life Connection type Dimensions Height Width Weight 250 V 3,0 A 24 V 2,0 A 250 V 3,0 A 24 V 2,0 A 250 V 3,0 A 24 V 2,0 A 10,0 A AgNi 400439 10 ms 400439 16,0 A AgNi 400441 10 ms 400441 10,0 A AgNi 400442 10 ms 400442 25 55 °C 30 70 °C 25 55 °C 50 85 °C 250 V 50 85 °C 250 V 50 85 °C 250 V IP65 400439 Any 50,000 cycles Springloaded terminal IP69K 400441 Any 6050 cycles Screw terminal IP69K 400442 Any 6050 cycles Springloaded terminal 92,0 mm 68,0 mm 77 g 100,0 mm 50,0 mm 62 g 92,0 mm 44,0 mm 56 g Where standards are undated, the 201305 latest editions shall apply. Operating Manual PIT es Set/1 1002542EN05 23 PIT es Set/1 Technical Details Order No. 400443400445 General Approvals Electrical data Volume resistance Min. contact current Relay outputs Utilisation category In accordance with the standard 400443 CE 400443 100 mOhm 1,00 mA 400443 400444 CE 400444 100 mOhm 5,00 mA 400444 400445 CE 400445 100 mOhm 1,00 mA 400445 EN 6094751 EN 6094751 EN 6094751 AC15 at Max. current DC13 (6 cycles/min) at Max. current Conventional thermal cur rent Contact material Times Bounce time Environmental data Ambient temperature Temperature range Storage temperature Temperature range Rated insulation voltage Protection type Housing Mechanical data Mounting position Mechanical life Connection type Dimensions Height Width Weight 250 V 3,0 A 24 V 2,0 A 250 V 3,0 A 24 V 2,0 A 250 V 3,0 A 24 V 2,0 A 16,0 A AgNi 400443 10 ms 400443 10,0 A AgNi 400444 10 ms 400444 16,0 A AgNi 400445 10 ms 400445 30 70 °C 25 55 °C 30 70 °C 50 85 °C 250 V 50 85 °C 250 V 50 85 °C 250 V IP65 400443 Any 20,000 cycles Screw terminal IP65 400444 Any 50,000 cycles Springloaded terminal IP65 400445 Any 20,000 cycles Screw terminal 100,0 mm 55,0 mm 78 g 93,0 mm 55,0 mm 72 g 100,0 mm 55,0 mm 77 g Where standards are undated, the 201305 latest editions shall apply. Operating Manual PIT es Set/1 1002542EN05 24 PIT es Set/1 Technical Details Order No. 400446400448 General Approvals Electrical data Volume resistance Min. contact current Relay outputs Utilisation category In accordance with the standard 400446 CE 400446 100 mOhm 5,00 mA 400446 400447 CE 400447 100 mOhm 1,00 mA 400447 400448 CE 400448 100 mOhm 5,00 mA 400448 EN 6094751 EN 6094751 EN 6094751 AC15 at Max. current DC13 (6 cycles/min) at Max. current Conventional thermal cur rent Contact material Times Bounce time Environmental data Ambient temperature Temperature range Storage temperature Temperature range Rated insulation voltage Protection type Housing Mechanical data Mounting position Mechanical life Connection type Dimensions Height Width Depth Weight 250 V 3,0 A 24 V 2,0 A 250 V 3,0 A 24 V 2,0 A 250 V 3,0 A 24 V 2,0 A 10,0 A AgNi 400446 10 ms 400446 16,0 A AgNi 400447 10 ms 400447 10,0 A AgNi 400448 10 ms 400448 25 55 °C 25 55 °C 25 55 °C 50 85 °C 250 V 50 85 °C 250 V 50 85 °C 250 V IP65 400446 Any 50,000 cycles Springloaded terminal IP65 400447 Any 20,000 cycles Screw terminal IP65 400448 Any 50,000 cycles Springloaded terminal 92,0 mm 55,0 mm – 69 g 72,0 mm 103,0 mm 72,0 mm 161 g 72,0 mm 103,0 mm 72,0 mm 155 g Where standards are undated, the 201305 latest editions shall apply. Operating Manual PIT es Set/1 1002542EN05 25 PIT es Set/1 Technical Details Order No. 400449400451 General Approvals Electrical data Supply voltage Voltage Kind Max. inrush current at UB Volume resistance Min. contact current Inputs Input current range Relay outputs Utilisation category In accordance with the standard 400449 CE 400449 400450 CE 400450 400451 CE, EAC (Eurasian) 400451 12,0 30,0 V AC/DC 44,00 mA 100 mOhm 1,00 mA 400449 15,0 mA 400449 – – – 100 mOhm 1,00 mA 400450 – 400450 – – – 100 mOhm 1,00 mA 400451 – 400451 EN 6094751 EN 6094751 EN 6094751 AC15 at Max. current DC13 (6 cycles/min) at Max. current Conventional thermal cur rent Contact material Times Bounce time Environmental data Ambient temperature Temperature range Storage temperature Temperature range Rated insulation voltage Protection type Housing Mechanical data Mounting position Mechanical life Connection type Dimensions Height Width Depth Weight 250 V 3,0 A 24 V 2,0 A 250 V 3,0 A 24 V 2,0 A 250 V 1,5 A 120 V 0,6 A 16,0 A AgNi 400449 10 ms 400449 16,0 A AgNi 400450 10 ms 400450 5,0 A AgNi 400451 10 ms 400451 25 55 °C 25 55 °C 25 55 °C 25 80 °C 250 V 50 85 °C 250 V 25 80 °C 250 V IP65 400449 Any 20,000 cycles Screw terminal IP65 400450 Any 20,000 cycles Screw terminal IP65 400451 Any 50,000 cycles Springloaded terminal 72,0 mm 103,0 mm 72,0 mm 178 g 103,0 mm 72,0 mm 72,0 mm 177 g 51,0 mm 42,0 mm 108,0 mm 122 g Where standards are undated, the 201305 latest editions shall apply. Operating Manual PIT es Set/1 1002542EN05 26 PIT es Set/1 Technical Details Order No. 400452400454 General Approvals Electrical data Supply voltage Voltage Kind Max. inrush current at UB Volume resistance Min. contact current Inputs Input current range Relay outputs Utilisation category In accordance with the standard 400452 CE 400452 400453 CE 400453 400454 CE 400454 – – – 100 mOhm 1,00 mA 400452 – 400452 – – – 100 mOhm 1,00 mA 400453 – 400453 12,0 30,0 V AC/DC 44,00 mA 100 mOhm 1,00 mA 400454 15,0 mA 400454 EN 6094751 EN 6094751 EN 6094751 AC15 at Max. current DC13 (6 cycles/min) at Max. current Conventional thermal cur rent Contact material Times Bounce time Environmental data Ambient temperature Temperature range Storage temperature Temperature range Rated insulation voltage Protection type Housing Mechanical data Mounting position Mechanical life Connection type Dimensions Height Width Depth Weight 250 V 3,0 A 24 V 2,0 A 250 V 3,0 A 24 V 2,0 A 250 V 3,0 A 24 V 2,0 A 16,0 A AgNi 400452 10 ms 400452 16,0 A AgNi 400453 10 ms 400453 16,0 A AgNi 400454 10 ms 400454 25 55 °C 25 55 °C 25 55 °C 50 85 °C 250 V 25 80 °C 250 V 25 80 °C 250 V IP65 400452 Any 20,000 cycles Screw terminal IP65 400453 Any 20,000 cycles M12 IP65 400454 Any 20,000 cycles M12 72,0 mm 103,0 mm 72,0 mm 172 g 103,0 mm 72,0 mm 85,0 mm 178 g 103,0 mm 72,0 mm 85,0 mm 212 g Where standards are undated, the 201305 latest editions shall apply. Operating Manual PIT es Set/1 1002542EN05 27 PIT es Set/1 Technical Details Order No. 400455400458 General Approvals Electrical data Volume resistance Min. contact current Relay outputs Utilisation category In accordance with the standard 400455 CE, EAC (Eurasian) 400455 100 mOhm 1,00 mA 400455 400457 CE 400457 100 mOhm 1,00 mA 400457 400458 CE, EAC (Eurasian) 400458 100 mOhm 1,00 mA 400458 EN 6094751 EN 6094751 EN 6094751 AC15 at Max. current DC13 (6 cycles/min) at Max. current Conventional thermal cur rent Contact material Times Bounce time Environmental data Ambient temperature Temperature range Storage temperature Temperature range Rated insulation voltage Protection type Housing Mechanical data Mounting position Mechanical life Connection type Dimensions Height Width Depth Weight – – – – 250 V 3,0 A 24 V 2,0 A 250 V 3,0 A 24 V 2,0 A – AgNi, vergoldet 400455 10 ms 400455 16,0 A AgNi 400457 10 ms 400457 16,0 A AgNi 400458 10 ms 400458 25 55 °C 30 70 °C 30 70 °C 25 80 °C 250 V 50 85 °C 250 V 50 85 °C 250 V IP65 400455 Any 50,000 cycles M12 IP65 400457 Any 20,000 cycles Screw terminal IP65 400458 Any 20,000 cycles Screw terminal 53,0 mm 42,0 mm 123,0 mm 113 g 100,0 mm 50,0 mm – 72 g 100,0 mm 52,0 mm – 60 g Where standards are undated, the 201305 latest editions shall apply. Operating Manual PIT es Set/1 1002542EN05 28 PIT es Set/1 Technical Details Order No. 400459 General Approvals Electrical data Volume resistance Min. contact current Relay outputs Utilisation category In accordance with the standard AC15 at Max. current DC13 (6 cycles/min) at Max. current Conventional thermal current Contact material Times Bounce time Environmental data Ambient temperature Temperature range Storage temperature Temperature range Rated insulation voltage Protection type Housing Mechanical data Mounting position Mechanical life Connection type Dimensions Height Width Weight CE, EAC (Eurasian) 100 mOhm 5,00 mA EN 6094751 250 V 3,0 A 24 V 2,0 A 10,0 A AgNi 10 ms 25 55 °C 50 85 °C 250 V IP65 Any 50,000 cycles Springloaded terminal 88,0 mm 44,0 mm 53 g Where standards are undated, the 201305 latest editions shall apply. Safety characteristic data Safety characteristic data B10d in accordance with EN ISO 138491 and EN IEC 62061 104.000 Lambdad/Lambda in accordance with EN IEC 62061 0,20 Operating Manual PIT es Set/1 1002542EN05 29 PIT es Set/1 Order reference Product Sets Product type Features Order no. PIT es Set1s1 PIT es1s + PIT esc1 + PIT MHR3 400 430 PIT es Set1s1c PIT es1s + PIT esc1c + PIT es holder 3c 400 431 PIT es Set1s5 PIT es1s + PIT esc1 + PIT esc2 + PIT MHR3 400 432 PIT es Set1s5c PIT es1s + PIT esc1c + PIT esc2c + PIT es holder 3c 400 433 PIT es Set2s5 PIT es2s + PIT esc1 + PIT esc2 + PIT MHR3 400 434 PIT es Set2s5c PIT es2s + PIT esc1c + PIT esc2c + PIT es holder 3c 400 435 PIT es Set3s5 PIT es3s + PIT esc1 + PIT esc2 + PIT MHR3 400 436 PIT es Set3s5c PIT es3s + PIT esc1c + PIT esc2c + PIT es holder 3c 400 437 PIT es Set5s5 PIT es5s + PIT esc1 + PIT esc2 + PIT MHR3 400 438 PIT es Set5s5c PIT es5s + PIT esc1c + PIT esc2c + PIT es holder 3c 400 439 PIT es Set7u5 PIT es7s + PIT esc1 + PIT esc2 + PIT MHR3 400 441 PIT es Set7u5c PIT es7s + PIT esc1c + PIT esc2c + PIT es holder 3c 400 442 PIT es Set8s5 PIT es8s + PIT esc1 + PIT esc2 + PIT MHR3 400 443 PIT es Set8s5c PIT es8s + PIT esc1c + PIT esc2c + PIT es holder 3c 400 444 PIT es Set1s6 PIT es1s + PIT esc1 + PIT esc2 + PIT MHR3 400 445 PIT es Set1s6c PIT es1s + PIT esc1c + PIT esc2c + PIT esc3c + PIT es holder 3c 400 446 PIT es Set1s5 s PIT es1s + PIT es box + PIT esc1 + PIT esc2 + PIT MHR3 400 447 PIT es Set1s5cs PIT es1s + PIT es box + PIT esc1c + PIT esc2c + PIT es holder3c 400 448 PIT es Set3s5 s PIT es3s + PIT es box + PIT esc1 + PIT esc2 + PIT MHR3 400 449 PIT es Set5s5 s PIT es5s + PIT es box + PIT esc1 + PIT esc2 + PIT MHR3 400 450 PIT es Set6u5cr Nonmodular set for rail mounting 400 451 PIT es Set1s6 s PIT es1s + PIT es box + PIT esc1 + PIT esc2 + PIT esc3 + PIT MHR3 400 452 PIT es Set1s5ns PIT es1s + PIT es box with M12 connector 400 453 PIT es Set3s5ns PIT es3s + PIT es box with M12 connector 400 454 PIT es Set6u5nr Nonmodular set with M12 connection for rail mounting 400 455 PIT es Set9u7 PIT es9u + PIT esc1 + PIT esc2 + PIT esc2 + PIT MHR3 400 457 PIT es Set9u5 PIT es9u + PIT esc1 + PIT esc2 + PIT MHR3 400 458 PIT es Set9u5c PIT es9u + PIT esc1c + PIT esc2c + PIT es holder3c 400 459 Operating Manual PIT es Set/1 1002542EN05 30 PIT es Set/1 ESTOP pushbutton Product type Features Order no. PIT es1s Inscription: ESTOP symbol 400 131 PIT es1u Uninscribed 400 531 PIT es2s Large (60 mm), inscription: ESTOP symbol 400 132 PIT es2u Large (60 mm), uninscribed 400 532 PIT es3s Illuminated, inscription: ESTOP symbol 400 133 PIT es3sc Illuminated, inscription: ESTOP symbol, with springloaded terminals 400 143 PIT es3u Illuminated, uninscribed 400 533 PIT es3uc Illuminated, uninscribed, with springloaded terminals 400 543 PIT es4s Illuminated, inscription: ESTOP symbol, protective collar 400 134 PIT es4u Illuminated, uninscribed, protective collar 400 534 PIT es5s Inscription: ESTOP symbol, protective collar 400 135 PIT es5u Uninscribed, protective collar 400 535 PIT es7u Uninscribed, IP69K 400 537 PIT es8s Inscription: ESTOP symbol, keyrelease 400 138 PIT es8u Uninscribed, keyrelease 400 538 PIT es9u Uninscribed 400 539 Contact blocks Product type Features Order no. PIT esc1 1 monitored N/C, screw terminal 400 315 PIT esc1c 1 monitored N/C, springloaded terminal 400 316 PIT esc2 1 N/C, screw terminal 400 320 PIT esc2c 1 N/C, springloaded terminal 400 321 PIT esc3 1 N/O, screw terminal 400 310 PIT esc3c 1 N/O, springloaded terminal 400 311 PIT esc4 4 N/C, screw terminal 400 324 PIT esc6c 1 N/C with monitoring, 1 N/O, 1 N/C, springloaded terminal 400 308 PIT esc8c 1 N/C, 1 N/O, springloaded terminal 400 309 Accessories Product type Features Order no. PIT MHR3 3 slots 400 330 PIT MHR5 5 slots 400 340 PIT es holder3c 3 slots, for springloaded terminals 400 331 Operating Manual PIT es Set/1 1002542EN05 31 PIT es Set/1 EC declaration of conformity This product/these products meet the requirements of the directive 2006/42/EC for ma chinery of the European Parliament and of the Council. The complete EC Declaration of Conformity is available on the Internet at www.pilz.com/downloads. Representative: Norbert Fröhlich, Pilz GmbH & Co. KG, FelixWankelStr. 2, 73760 Ost fildern, Germany Operating Manual PIT es Set/1 1002542EN05 32 Americas Australia Scandinavia Brazil +61 3 95446300 +45 74436332 Spain +55 11 97569-2804 Europe +34 938497433 +1 888-315-PILZ (315-7459) Austria Switzerland Mexico +43 1 7986263-0 +41 62 88979-30 +52 55 5572 1300 Belgium, Luxembourg The Netherlands USA (toll-free) +32 9 3217575 +31 347 320477 +1 877-PILZUSA (745-9872) France Turkey +33 3 88104000 +90 216 5775552 Asia Germany United Kingdom China +49 711 3409-444 +44 1536 462203 +86 21 60880878-216 Ireland Japan +353 21 4804983 You can reach our +81 45 471-2281 Italy international hotline on: South Korea +39 0362 1826711 +49 711 3409-444 +82 31 450 0680 [email protected] Pilz develops environmentally-friendly products using ecological materials and energy-saving technologies. products and environmentally-friendly solutions. Partner of: The Best of German En gineering Pilz GmbH & Co. KG Felix-Wankel-Straße 2 73760 Ostfildern, Germany Tel.: +49 711 3409-0 Fax: +49 711 3409-133 [email protected] www.pilz.com CMSE ® , InduraNET p ® , PAS4000 ® , PAScal ® , PASconfig ® , Pilz ® , PIT ® , PLID ® , PMCprimo ® , PMCprotego ® , PMCtendo ® , PMD ® , PMI ® , PNOZ ® , Primo ® , PSEN ® , PSS ® , PVIS ® , SafetyBUS p SafetyEYE ® , SafetyNET p ® , the spirit of safety ® are registered and protected trademarks of Pilz GmbH & Co. KG in some countries. We would point out that product features may vary from the details stated in this document, depending on the status at the time of publication and the scope of the equipment. We accept no responsibility for the validity, accuracy and entirety of the text and graphics presented in this information. Please contact our Technical Support if you have any questions. ® Canada © Pilz GmbH & Co. KG, 2011 Technical support is available from Pilz round the clock. , Support 100XXXX-DE-0X 0-0-2-3-000, 2014-00 Printed in Germany © Pilz GmbH & Co. KG, 2014 1002542EN05, 201409 Printed in Germany Back cover
© Copyright 2026 Paperzz