Three-in-one beauty instrument Operating guidance Instruction manual before usage Caution This equipment is divided into four parts: ELectiric Light Synergy, Radio Frequency, IPL, and Laser Read carefully the instruction manual before using it, in order to get familiar with all of the security demands and operating steps. Any glare or radio frequency equipment can cause injure accidents if it is used improperly. Get familiar with the potential danger mentioned in this manual before operating, and adopt corresponding safety protection measures. Safety Protection Demands: This chapter mainly introduces safety protection of the equipment in the process of using and maintenance. System Safety Protection Demands: Only specialized training personnel can use this equipment. Operators and other personnel should get familiar with the safety protection demands when they are operating or maintaining the equipment. Above all, personnel should fully take the personnel safety of operators and customers into account in the treatment. Operators should ensure customers’ safety protection. First of all, operators should ensure the personnel safety of customers in the treatment. Operators should detailedly know customers’ past medical history before using this equipment for treatment, make sure whether customers can receive treatment, require customers to fill in treatment agreement completely and detailedly tell customers the relevant treatment methods and the side effect and risk may be occurred in the treatment. Customers should wear the specialized protection eye patches in the treatment. Safety Protection for Operators Do not operate the equipment without totally familiarity with the equipment before using it. System operators should wear the specialized protection eye patches in the treatment; there should be evident glare sign in the equipment treatment room. Safety Attentions There are no servicing components for users except changing water. Only professional technical personnel can overhaul this equipment, especially the internal parts of the equipment. Users should keep the delivery port of the treatment head clean. If any leaking of the equipment or treatment head is discovered, users should turn out the equipment at once and contact with the manufacturer. The action of disassembling the equipment is prohibited. The action of putting the treatment head contacts with some hard goods is prohibited, or it may damage the electrode delivery port of RF. Photology Safety Protection The glare may damage eye or cause amqsauq or burn, so you should take some necessary safety protection measures in the area that using this equipment. Over high power can cause thermal burn to the treatment area, so operators in the operating room must wear specialized protection glasses, and there must be evident glare caution sign in the treatment room when they are using this equipment. We should make sure all of the operators have already expertly commanded the emergency measures in the emergency situation. Using this equipment in the flammable and explosive environment is prohibited. Looking directly at the delivery port of treatment head is prohibited, even wearing protection glasses. The treatment head should be hung over the equipment when it is not used. The delivery port of treatment head should point at the treatment parts during the treatment. There should not have any jewelry or mirror or other light emission goods in the operating work field. Electric and Machine Safety All of the vision and panel should be kept closed, making bold to open the chassis can cause safety misadventure; hands should be kept away from treatment head during the process of starting outfit; the repairing work can only be done when the equipment is closed or the power is cut; as the equipment is quite heavy, it may cause personal injury accident if the displacement method is improperly, so you must displace the equipment carefully; this equipment contacts with earth through earth wire of power line, sound earth connection is of critical significance to safe operation. Fire Prevention The absorption of light energy can elevate the temperature of absorbing objects, so it is prohibited to use this equipment in flammable and explosive environment. Please do not use flammable materials when you are preparing skin treatment. If you clean and sterilize the equipment by the use of alcohol, you must use the equipment when it is completely dry. System Safety Protection Methods When all of the operators are operating this equipment, they should get familiar with the safety protection methods: only starting up key can open the equipment, and the key switch can only be taken down in OFF condition. The equipment is installed with a red emergency stop button. You can stop the equipment immediately by pressing the button no matter in which kind of condition. Only if the treatment head is connected with the equipment, the power source can be turned on. The eradiating treatment can be started when the standby condition of the equipment is turned into preparing condition. The equipment will self-check its system when it is started. Equipment Classification Electrical appliance protection: I type, BF type; Feed liquor protection: common equipment; This equipment is inappropriate to be used in the flammable and explosive environment. Operation model: succession Equipment Installation This equipment can be directly installed in the treatment room. Users can install the equipment according to the following steps. You should check whether there is any breakage in the equipment and all of the fittings. Then you should open the radiator cap up in counter-clockwise direction, put cooling water in, and screw on the radiator cap in clockwise direction. Next, you should connect the treatment head by inserting one side of the power line into the power jack of the mainframe, and another side into the external power. Then you should detect equipment and every operating function. Electric Demands The equipment has preset the rated voltage based on customers’ locus before it left the factory. The corresponding electric demands of this equipment are as follows: single-phase 110v±15% AC; 15A; 60 Hz or single-phase 110v±15% AC; 10A; 50 Hz. In order to prevent fire accidence, when you change protective tube, you must change the protective tube of the same type. It can ensure the function of self-protection. It is the basic guarantee of safety operation when the equipment fully connected with earth. There should not be any corrosive particle in the air of the operation equipment room. It is because the corrosive particle can cause the damage of all kinds of electric elements. The dust in the air of operation equipment room should be as fewer as possible. It is because the metallics in the dust can cause the damage of electric elements. Other dust mites can absorb the light energy and then be heated. However, the caloric dust which attaches to the optical crystalloid can cause damage to the optical crystalloid. The optimal environment temperature of the equipment working is 20℃-25℃, and the relative humidity cannot exceed 80%. In order to protect the cooling system from frozen damage, it is prohibited to put the equipment with water in the environment which the temperature is below 2℃. Equipment Displacement Displacement in the treatment room: ·power off ·disconnecting the power line ·hanging the treatment head in the equipment ·loosening the coaster brake ·pushing slowly the handle to displace the equipment Displacing the equipment to other places ·power off ·disconnecting the power line ·dismounting the treatment head and putting it in the treatment head box(this item is invalid to some instruments) ·blowing the cooling water of the equipment off ·loosening the coaster brake ·moving carefully the equipment to the conveyance and laying it properly When the equipment arrived at a new installation, users should assemble it according to the installation requirement. Equipment Operation Power on/ off Before operators turn on the equipment, they should make sure the power line has connected with the convenience receptacle of the mainframe and outside convenience receptacle. There are high voltage in the inner equipment, the treatment head should be connected in the equipment and hung over the pothook of the equipment during the turning on process. The treatment head will emit the high strength pulsed light during the treatment, so everyone in the treatment room should wear specialized protection glasses (people cannot look directly at the glare emitted from the treatment head even wearing glasses). Eradiating excessive glare to the treatment parts may cause skin temperature damage, and consequently cause abnormal pigmentation, atrophy or large. Operating Guidance [ELectiric Light Synergy Part] 1. Standby Interface You should turn on the power switch of the equipment. The starting up【Function Selection】interface is shown in figure 1. 【Figure 1: Function Selection】 Then you should choose the corresponding function【E-LIGHT】 to enter into the workspace of this function. This interface mainly shows the operating mode and frequency of the system, and the current temperature, energy, point, refrigerating capacity, model, pulse waveform of the system, etc. As shown in figure 2: Parameter adjustment Treatment mode Current treatment of points The current temperature 【Figure 2:Standby Interface】 Working state Now you should press【ready】to enter the preparation interface, close the operating switch under the preparation condition to process treatment. As shown in figure 3 【Figure 3: Preparation Interface】 【Radio Frequency Part】 You should press【RF】on the function selection interface to enter the workspace of this function: As shown in figure 4 Parameter adjustment Treatment mode Current treatment of points 【Standby Interface】 Working state Now you should press【ready】on the standby interface to enter the preparation condition, close the operating switch under the preparation condition to process treatment. 【The Photon Operation Part is Equal to E-light Synergy Part】 【Laser Part】 You should turn on the power of laser part to enter the system standby interface: as shown in figure 5. Energy intensity shows The mode The current frequency System Status Switch state current The current temperature 【Figure 5:Laser Standby Interface】 Now you should press【ENTER】on the standby condition to enter the preparation interface, as shown in figure 6. 【Figure 6:Laser Preparation Interface】 You should close the operating switch under preparation condition to start treatment. 1. Capacity regulator Firstly, you should press the substract key, then press add-substract key within three minutes to increase or decrease energy level. 2. Frequency adjustment Firstly, you should press the substract key, then press add-substract key within three minutes to increase or decrease the glaring frequency. 3. Preparation before treatment Operators should learn about whether customers are scar diathesis; operators should observe whether customers have removed eyebrow tattoo, made tattoo before in other means, and whether there are existing scars. Operators should explain to customers that after the tattoo removed, there may remain pigmentation. These pigmentations are caused by solarization after tattoon. Operators should explain to customers that the tattoo materials may be compound colorant. There may remain coffee or red colorant after the black blue was removed. Operators will use green light for treatment after two months interval treatment. Operators should illustrate the possible situation during the treatment and after the treatment to the customers. (The situation is as follows). In order to prevent the unnecessary disputes caused by customers’ unknowing of the surgery situation, after surgery reflection and recovery process. Before removing eyebrow tattoo, operators can shave the eyebrows off for better observation during the surgery. 4. The possible situation during surgery When operators are treating the tissues of rather deep color and layer, it may produce rather intense pigment burst with relative strong noises because of the intense absorption of melanin to the laser energy. The body tissues will produce swelling by reason of pigment being shattered. The relative exterior pigment will form exudation point by reason of absorbing energy and bursting out of scarfskin. The tissue color will become very light in the first laser treatment, but after a while (over ten minutes to several quarters), the tattoo color will recover to some extent. It is the normal reaction of the tissue. The phagolysis and transportation function of macrophage will sustain relative long time. During this period, the tissue color will gradually become light. We suggest that the second treatment should be processed two or three months after the first treatment. Particular stress: when operators are processing the surgery of removing eyeline, eyeball must be absolutely protected by the use of tarsi, or operators must be prohibited treatment!!! 5. The possible phenomena after surgery The hair may be decolored or shed, but it can outgrow new hair in about four weeks and it may be denser than before for a while, and it can tend to normal gradually. The extent of exudation and swelling in the treatment part varies from person to person. People may feel itch after detumescence. And people may have the situation of tissues becoming hard when you touch it. All of these situations belong to the normal reflection of tissues. All of the discomfort feelings will completely disappear in about one week to one month. The time varies from person to person. 6. medical advice after surgery The infection behavior of penciling the eyebrows, washing and others are prohibited in three to seven days; protecting oneself from solarization; one of more bleeding and severe swelling can take some antibiotic drug. Appendix 2: the attention items of applying 532nm laser for treating brown and red pigment The laser of 532nm wavelength is the green visible laser. The function of it to biological tissue has great distinction compared with laser of 1064nm wavelength. The hemoglobin in human body and the brown and red pigment tattooed in the tissues have rather strong absorption to 532nm laser. By reason of the color of normal skin tissue has certain absorption to 532nm laser; the epidermal tissue may produce vaporization in the surface layer through laser irradiation. The tissues of subcutaneous capillary vessel and others can become burst and form subcutaneous congestion after absorbing laser irradiation. It is called purpura medically. After brown and red pigments absorbed 532nm laser, they will become burst and be popped out of body or be shattered so that they can be metabolized and exhausted out of body by macrophage. The possible side effects may be caused by the use of 532nm laser to remove red pigment: ①. The surface of skin becomes pale, the scarfskin becomes putrescence, and it may cause characteristic pigment loss or pigmentation. ②. The treatment parts become red and swollen, subcutaneous tissues present purpura, and the over injury may cause scab. The recovery time is about 20 to 60 days varies from person to person according to individual distinction. When operators take the methods of 532nm laser to remove brownish red pigment, they should apply small energy density, namely large facula, close distance treatment, and adopt the methods of multiple treatments to deal with the relative deep pigment layer. The interval of each treatment is no less than two months. Before treatment, operators should explain these situations to customers. The treatment may have side effects. There may contain ferric ion in very few colorant, after ferric ion absorbed laser, it can transform into iron oxide, cause the tattoo color become black and darker, and result in treatment failure. After treatment, customers should avoid touching water, touching and others for fear of infection, protect themselves from solarization for fear of pigmentation. Human eyes are very sensitive to 532nm laser. The dispersion or projectivity of laser to human eyes can result in impaired vision or permanent blindness. So customers must wear laser goggles during the treatment to protect customers’ eyes. The irrelevant personnel should leave the treatment room. Special Prompt: Please put purified water or distilled water【no mineral water, tap water】into the equipment before using it, or it may cause the permanent damage to the equipment.
© Copyright 2026 Paperzz