DMC-300SC 100BASE-T to 100BASE-FX multi-mode Media Converter Rev. C1 Reliability Test Report APPROVED CHECKED DEPARTMENT 1 PREPARED Table of Contents: PASS or Fail 1. Storage Temperature Test ■ □ 2. Low Temperature Test ■ □ 3. High Temperature Test ■ □ 4. Temperature & Humidity Test ■ □ 5. Four Corner Test ■ □ Switch: DMC-300M Rev. C1 2 1 Storage Temperature Test 1.1 Sample Size : 2 pcs 1.2 Test Condition : The DUTs should be placed in the chamber to complete 6 cycles and subjected to the following conditions : * Non-Operating Temp. 70℃ 25℃ -20℃ 0 1 2 5 6 7 8 11 12 Hrs 1.3 Results : 1. Visual inspection was normal. 2. Data transmit & receive function was normal during the test. 3 2 Low Temperature Test 2.1 Sample Size : 2 pcs 2.2 Test Condition : The DUTs should be placed in the chamber to complete 1 cycle and subjected to the following conditions: * Operating * Ramp temperature down to 0 ℃ in 1 hour. * Hold Low temperature at 0 ℃ for 72 hours. * Ramp temperature up to 25 ℃in 1 hour. Temp. ℃. 25℃ 0℃ 0 1 73 74 Hrs 2.3 Results : 1. Visual inspection was normal. 2. Data transmit & receive function was normal during the test. 3. 0℃power on and TX/RX function was normal. 4 3 High Temperature Test 3.1 Sample Size : 2 pcs 3.2 Test Condition : The DUTs should be placed in the chamber to complete 1 cycle and subjected to the following conditions: * Operating * Ramp temperature up to 55 ℃ in 1 hour. * Hold High temperature at 55 ℃ for 72 hours. * Ramp temperature down to 25 ℃ in 1 hour. Temp. 55℃ Temp. 25℃ Temp. Temp. 0 1 73 74 Hrs 3.3 Result : 1. Visual inspection was normal. 2. Data transmit & receive function was normal during the test. 5 4 Temperature & Humidity Test 4.1 Sample Size : 2 pcs 4.2 Test Condition : The DUTs should be placed in the chamber to complete 6 cycle and subjected to the following conditions: * Operating Temp. 40℃ 25℃ 0℃ 0 1 5 7 11 12 Hrs Humidity 95 % 55% 0% 0 1 5 7 11 12 Hrs 4.3 Result : 1. Visual inspection was normal. 2. Data transmit & receive function was normal during the test. 6 5 Four Corner Test Report 5.1 Sample Size : 2 pcs 5.2 Test Condition : * Full Loading Operation * Chamber Temperature : 0℃ And 55 ℃ * AC Voltage : 95V And 120V * All test procedure as follow: 5.3 Result : Expectations : It should be no any CRC, Alignment and Oversize errors. AC 95V 120V -10 ℃ Pass Pass 55 ℃ Pass Pass Temp 7 6 TESTING/VERIFICATION REPORT 6.1 TEST & VERIFICATON RESULT No error found. 6.2 EVALUATION & CONCLUSION 6.3 SUGGESTION 8
© Copyright 2026 Paperzz