Odessa First Fix Installation Guide

Odessa First Fix Installation Guide
The Majestic Shower Company Limited
One North Place, Edinburgh Way, Harlow, Essex
CM20 2SL England
Telephone +44 (0) 8448 001 500
Facsimile +44 (0) 1279 635 074 [email protected]
www.majesticshowers.com
Odessa First Fix Installation Guide
Page 1
Thank you for purchasing this Odessa shower screen. Please study these instructions carefully before assembly and
installation and check all supplied parts immediately upon receipt.
These instructions illustrate an enclosure with the door on the left and a fixed panel on the right. However, all parts are
reversible and the door may optionally be positioned to the right of the fixed panel provided the recessed wall channels
have been installed accordingly.
These instructions also illustrate an enclosure with the door sliding on the inside (shower side) of the fixed panel. This is
the most common configuration.
First Fix Installation
These instructions cover First Fix installation only. Separate instructions are available for the Second Fix installation.
First fix comprises:
- installation of recessed track RS17 to ceiling
- installation of recessed 24mm wall channel to panel side wall
- installation of recessed door closure channel RS1 to door side wall
- installation of 17mm surface channel recessed into floor.
Tolerances on Finished Walls, Floor and Ceiling
The parts supplied for first fix installation are supplied precisely pre-cut to fit the finished wall to wall and finished floor to
ceiling dimensions that you have specified.
Finished floor to finished ceiling dimensions should be within 3-4mm of specified height. Finished wall to wall dimensions
should be within 5-6mm of specified width.
The finished floor and ceiling surfaces should be plumb horizontal. Walls should be plumb vertical. Some lean-in or lean-out
can be accommodated on the panel side wall (up to 5-6mm) but the door side wall has to be very close to vertical to ensure
adequate sealing of the door into the wall channel (2-3mm maximum deviation).
Floor and wall channels should be free of debris or obstructions.
Parts Supplied
The following parts are supplied for First Fix installation. Please check them and contact Majestic in the event of
missing or damaged parts.
1 x RS17 Recessed Track for ceiling, pre-fitted with end plates
1 x 24mm recessed wall channel for panel side wall
1 x RS1 Door Closure channel for door side wall
1 x 17mm surface channel for recessing into floor
1 x Channel Positioning Block
The Majestic Shower Company Limited
One North Place, Edinburgh Way, Harlow, Essex
CM20 2SL England
Telephone +44 (0) 8448 001 500
Facsimile +44 (0) 1279 635 074 [email protected]
www.majesticshowers.com
Odessa First Fix Installation Guide
Page 2
89.0
80.0
Structural Beam
Fixed Panel slot
CL Fixings
CL Fixed Panel
CL Door
INSIDE OF
SHOWER
1
OUTSIDE OF
SHOWER
The ceiling should be prepared with a recess to accept
the RS17 aluminium track. The recess should be 89.0
mm wide by 80.0 mm deep and extend the full width of
the alcove from structural wall to structural wall.
31.0
2
Note that the Fixed Panel slot on the track is to face the
outside of the shower.
Immediately above the ceiling recess, there
should be a structural beam adequate to support
the weight of the track, rollerheads and door and
to which the track can be screwed.
The track is supplied with 6 mm diameter
countersunk holes for attachment to the beam at
approximately 300 mm centres on the centreline
shown.
Finished Wall to Wall dimension + 30mm
Finished Wall to Wall dimension + 30mm
CL
Track
Finished Wall to Wall dimension
Finished Wall to Wall dimension
CL
The track is supplied pre-prepared with a small
rebate machined at each end. The distance
between these rebates equals the specified finished
wall to wall dimension.
Floor channel
Finished Wall to Wall dimension + 46mm
rebate
3
Track
4
The 17mm surface channel is to be recessed into the
floor and is supplied at the specified finished wall to
wall dimension + 46mm.
It is to be positioned centred below the track as
Once the wall finish is in place, the track should
extend about 15 mm beyond it at each end (that is,
the track is supplied at an overall length of the
specified wall to wall dimension + 30 mm).
The Majestic Shower Company Limited
One North Place, Edinburgh Way, Harlow, Essex
CM20 2SL England
shown above.
Telephone +44 (0) 8448 001 500
Facsimile +44 (0) 1279 635 074 [email protected]
www.majesticshowers.com
Page 3
Odessa First Fix Installation Guide
Fixed Panel slot
Finished ceiling
Finished floor
17.0
13.5
Finished
Floor
CL Fixed Panel
Floor
channel
Silicone bead (2 Places)
5
The floor channel will accept the fixed glass panel
and is to be centred directly below the fixed panel
slot of the ceiling track.
6
The floor channel has an overall width of
13.5 mm and the recess depth is 17 mm.
Apply a thin bead of silicone to both sides of the
recess and fit the aluminium profile.
Finished ceiling
CL Fixed Panel
Recessed 24mm
wall channel
Finished floor
7
Floor
channel
The recessed channel on the panel side wall
links the floor channel and the fixed panel slot in
the ceiling track, forming a continuous slot for
the Fixed Panel.
The Majestic Shower Company Limited
One North Place, Edinburgh Way, Harlow, Essex
CM20 2SL England
8
Alignment of the 24mm recessed wall channel
and the fixed panel slot on the Track can be
checked using the Channel Positioning block
provided, as shown above.
Telephone +44 (0) 8448 001 500
Facsimile +44 (0) 1279 635 074 [email protected]
www.majesticshowers.com
Odessa First Fix Installation Guide
Page 4
24.0
14.5
Silicone bead
Alignment of the 24mm recessed wall channel
with the floor channel can similarly be checked
using the Channel Positioning block provided, as
shown above.
9
10
Silicone bead
The wall channel has an overall width of
14.5 mm and the recess depth is 24 mm.
Apply a thin bead of silicone to both sides of the
recess and fit the aluminium profile.
Fixed Panel
slot
CL Fixed Panel
CL Door Closure channel
20.0
Floor
channel
11
22.5
Door Closure
channel
The Door Closure channel on the door side wall
is offset from the other channels by 20 mm as
shown above.
12
Alignment of the Door Closure channel with the
Fixed panel slot in the Track can be checked
using the Channel Positioning block provided
as shown above.
Although it is to be fitted to a recess that runs from
floor to ceiling, the channel is not to occupy the
bottom 22.5mm of recess (a component is fitted
into this space during second fix installation).
The Majestic Shower Company Limited
One North Place, Edinburgh Way, Harlow, Essex
CM20 2SL England
Telephone +44 (0) 8448 001 500
Facsimile +44 (0) 1279 635 074 [email protected]
www.majesticshowers.com
Odessa First Fix Installation Guide
Page 5
10.0
16.5
Silicone bead
13
Alignment of the Door Closure channel with the
Floor channel can similarly be checked using the
Channel Positioning block provided, as shown
above.
The Majestic Shower Company Limited
One North Place, Edinburgh Way, Harlow, Essex
CM20 2SL England
14
Silicone bead
The Door Closure channel has an overall width of
16.5 mm and the recess depth is 10.0 mm.
Apply a thin bead of silicone to both sides of the
recess and fit the aluminium profile.
Telephone +44 (0) 8448 001 500
Facsimile +44 (0) 1279 635 074 [email protected]
www.majesticshowers.com