INDUCTIVE PROXIMITY SENSORS PS STANDARD LINE IEC standard. Compact size, manufactured with SMD components. AC / DC models. Protected against short-circuit or reverse polarity. Sensing distance (Sn) Connection Sn = 1; 1.5; 2; 4; 5; 8; 10 or 15 mm Tube length 25 mm - M8 or 6.5 mm Namur 45 mm - M8 or 6.5 mm E or E2 50 mm - M12; M18 or M30 (standard) 60 mm - M12; AC 70 mm - M12; M18 or M30 (long) PS Inductive proximity sensor -- standard - 2 m PVC cable 6 - 6 m PVC cable PU - 2 m polyurethane cable V8 - 3-pin connector M8 male V1 - 4-pin connector M12 male V13 - 3-pin connector M12 male PS 15 - 30 GI 50 - A2 -V1 Tube diameter Electrical connection Non-thread tube Φ 6.5. Φ 8 Threaded tube: M8x1; M12x1; M18x1; M30x1.5 N - 2-wire / DC / Namur (DIN-19234) N4- 2-wire / DC / NO N5 - 2-wire / DC / NC E - 3-wire / DC / NPN -NO A - 4-wire / DC/ NPN-NO+NC E2 - 3-wire / DC / PNP-NO A2 - 4-wire / DC / PNP-NO+NC UA - 2-wire / AC or DC / NO UF - 2-wire / AC or DC / NC UZA - 2-wire / AC or DC / NO with short-circuit protection UZF - 2-wire / AC or DC / NO with short-circuit protection WA - 2-wire / AC / NO WF - 2-wire / AC / NC Tube G - threaded tube Tube type I - nickel plated brass, backside led M - nickel plated brass, lateral led P - plastic, backside led X - stainless steel, backside led T - PTFE plated brass, backside led PS - INDUCTIVE STANDARD LINE Sensors and Instruments φ6.5 / φ8 DC NAMUR Cable NAMUR PS1-6,5-25-N PS2-6,5-25-N PS1-8-25-N PS2-8-25-N 1 2 3 4 1 mm 2 mm 1 mm 2mm 0.81 mm 1.62 mm 0.81 mm 1.62 mm Mounting flush non-flush flush non-flush Hysteresis 5% 5% 5% 5% < 0.01 mm < 0.01 mm < 0.01 mm < 0.01 mm 8 x 8 mm 8 x 8 mm 8 x 8 mm 8 x 8 mm ( DIN 19324 ) Drawing Nominal sensing distance Operating distance Repeatability Standard target Operating voltage range 7 to 12 Vdc 7 to 12 Vdc 7 to 12 Vdc 7 to 12 Vdc Nominal voltage 8 Vdc 8 Vdc 8 Vdc 8 Vdc Ripple ±5% ±5% ±5% ±5% Activated sensor current ≤1 mA ≤1 mA ≤1 mA ≤1 mA Deactivated sensor current ≥ 3 mA ≥ 3 mA ≥ 3 mA ≥ 3 mA Max. cable impedance 100 Ω 100 Ω 100 Ω 100 Ω Max. switching frequency 1 kHz 600 Hz 1 kHz 600 Hz --- --- --- --- - 25oC to + 100oC - 25oC to + 100oC - 25oC to + 100oC - 25oC to + 100oC IP 67 IP 67 IP 67 IP 67 50g 50g 50g 50g 2 m PVC cable,2 x 25 AWG 2 m PVC cable, 2 x 25 AWG 2 m PVC cable,2 x 25 AWG 2 m PVC cable,2 x 25 AWG Output indicator Operating temperature range Protection class Weight Connection Cable options 6 m PVC cable 6m PVC cable 6 m PVC cable 6 m PVC cable Tube length 25 mm 25 mm 25 mm 25 mm Ex Certified Cepel Ex-015 / 98 Cepel Ex-015 / 98 Cepel Ex-015 / 98 Cepel Ex-015 / 98 4 Electrical connections Code Housing ---- 4 nickel plated brass NAMUR SENSOR 25 AMPLIFIER 25 mm tube length (standard) (+) BN 8Vdc Cable Color Exi BN - brown - positive (-) BU BU - blue - negative NOTE : WITHOUT LED Ø Dimensions Ø8 25 25 25 25 4 4 Ø8 Inductive Line Ø8 .5 .5 Ø6 Ø6 1 2 3 4 1.1 PS - INDUCTIVE STANDARD LINE Sensors and Instruments φ6.5 / φ8 DC 3-Wire Cable NO - NPN PS1,5-6,5-45-E PS2-6,5-45-E PS1,5-8-45-E PS2-8-45-E NO - PNP PS1,5-6,5-45-E2 PS2-6,5-45-E2 PS1,5-8-45-E2 PS2-8-45-E2 5 6 7 8 Nominal sensing distance 1.5 mm 2 mm 1.5 mm 2 mm Operating distance 1.21mm 1.62 mm 1.21 mm 1.62 mm Mounting flush non-flush flush non-flush Hysteresis 5% 5% 5% 5% < 0.01 mm < 0.01 mm < 0.01 mm < 0.01 mm 8 x 8 mm 8 x 8 mm 8 x 8 mm 8 x 8 mm 10 to 30 Vdc 10 to 30 Vdc 10 to 30 Vdc 10 to 30 Vdc Ripple ± 10 % ± 10 % ± 10 % ± 10 % Max. switching current 100 mA 100 mA 100 mA 100 mA Drawing Repeatability Standard target Operating voltage range ≤ 10 mA ≤ 10 mA ≤ 10 mA ≤ 10 mA Output voltage drop <2V <2V <2V <2V Max. switching frequency Current consumption 1 kHz 600 Hz 1 kHz 600 Hz Protection circuit reversal and short-circuit reversal and short-circuit reversal and short-circuit reversal and short-circuit Output indicator lateral led lateral led lateral led lateral led Operating temperature range - Protection class Weight Connection Cable options Tube length 25oC to + 70oC - 25oC to + 70oC - BN BK BU NO PNP-E2 IP 67 IP 67 50g 50g 50g 50g 2 m PVC cable,3 x 25 AWG 2 m PVC cable,3 x 25 AWG 2 m PVC cable,3 x 25 AWG 2 m PVC cable,3 x 25 AWG 6m PVC, 2 m PU cable 6m PVC, 2 m PU cable 6m PVC, 2 m PU cable 6m PVC, 2 m PU cable 45, 60 mm(option) 45, 60 mm(option) 45, 60 mm(option) 45, 60 mm(option) Code 10 - 30Vdc - BN Housing --- nickel plated brass and lateral led 45 45 mm tube length (standard) 60 460 mm tube length (option) Cable Color + BK - 25oC to + 70oC IP 67 + 4 to + 70oC IP 67 Electrical connections NPN-E 25oC 10 - 30Vdc BU BN - brown / BU - blue BK - black - NO Dimensions Ø 13 .3 45 e lat d 4 .9 45 l era la t 13 .3 45 led ral e t la l ed 6 12 .9 4 l le era l at d Ø8 Ø8 .5 .5 Ø6 Ø6 5 1.2 le ra l 12 Ø8 Ø8 45 7 8 Inductive Line 1 PS - INDUCTIVE STANDARD LINE 3 φ6.5 DC 3-Wire Connector NO - NPN PS1,5-6,5-45-E-V8 PS2-6,5-45-E-V8 NO - PNP PS1,5-6,5-45-E2-V8 PS2-6,5-45-E2-V8 9 10 Nominal sensing distance 1.5 mm 2 mm Operating distance 1.21mm 1.62 mm Mounting flush non-flush Hysteresis 5% 5% < 0.01 mm < 0.01 mm 8 x 8 mm 8 x 8 mm Drawing 4 Repeatability Standard target Operating voltage range 10 to 30 Vdc 10 to 30 Vdc Ripple ± 10 % ± 10 % Max. switching current 100 mA 100 mA Current consumption ≤10 mA ≤ 10 mA Output voltage drop <2V <2V Max. Switching frequency 1 kHz 600 Hz reversal and short-circuit reversal and short-circuit 4-microled 4-microled - 25oC to + 70oC - 25oC to + 70oC IP 67 IP 67 15g 15g Connection 3-pin connector 3-pin connector Tube length 45, 60 mm(option) 45, 60 mm(option) Circuit protection Output indicator Operating temperature range Protection class Weight V8 Connector 2* Electrical connections NPN-E (1) (2*) (3) NO PNP-E2 (1) (2*) (3) + Code 10 - 30Vdc 1 - 3 Housing --- nickel plated brass and lateral led 45 45 mm tube length (standard) 60 60 mm tube length (option) + 10 - 30Vdc - NO Dimensions d l le e ra lat 10 d l le e ra l at 10 45 L 45 4 Ø Ø6 6.5 .5 9 Inductive Line 10 1.3 PS - INDUCTIVE STANDARD LINE M8 NAMUR DC Cable NAMUR PS1-8GM25-N PS2-8GM25-N 11 12 1 mm 2 mm 0.81mm 1.62 mm Mounting flush non-flush Hysteresis 5% 5% < 0.01 mm < 0.01 mm 8 x 8 mm 8 x 8 mm 7 to 12 Vdc 7 to 12 Vdc 8 Vdc ± 5 % 8 Vdc ± 5 % ±5% ±5% Activated sensor current ≤ 1 mA ≤ 1 mA Deactivated sensor current ≥ 3 mA ≥ 3 mA Max. cable impedance 100 Ω 100 Ω Max. switching frequency 1 kHz 600 Hz ( DIN 19324 ) Drawing Nominal sensing distance Operating distance Repeatability Standard target Operating voltage range Nominal voltage Ripple Output indicator Operating temperature range Protection class Weight Connection Cable options --- --- 25oC to + 100oC - 25oC to + 100oC IP 67 IP 67 55g 55g 2 m PVC cable,2 x 25 AWG 2 m PVC cable,2 x 25 AWG 6 m PVC cable 6 m PVC cable Tube length 25 mm 25 mm Ex Certified Cepel Ex-015 / 98 Cepel Ex-015 / 98 Electrical connections Code GM NAMUR SENSOR 25 AMPLIFIER BN (+) 8Vdc BU (-) Housing nickel plated brass 25 mm tube length (standard) Cable Color Exi BN - brown - positive BU - blue - negative NOTE : WITHOUT LED Dimensions 11 1.4 12 Inductive Line PS - INDUCTIVE STANDARD LINE M8 DC 3-Wire Cable NO - NPN PS1,5-8GM45-E PS2-8GM45-E NO - PNP PS1,5-8GM45-E2 PS2-8GM45-E2 13 14 Nominal sensing distance 1.5 mm 2 mm Operating distance 1.21mm 1.62 mm Mounting flush non-flush Hysteresis 5% 5% < 0.01 mm < 0.01 mm 8 x 8 mm 8 x 8 mm Drawing Repeatability Standard target Operating voltage range 10 to 30 Vdc 10 to 30 Vdc Ripple ± 10 % ± 10 % Max. switching current 100 mA 100 mA Current consumption ≤10 mA ≤ 10 mA Output voltage drop <2V <2V Max. switching frequency 1 kHz 600 Hz reversal and short-circuit reversal and short-circuit lateral led lateral led - 25oC to + 70 oC - 25oC to + 70oC IP 67 IP 67 55g 55g 2 m PVC cable 3 x 25AWG 2 m PVC cable 3 x 25AWG Circuit protection Output indicator Operating temperature range Protection class Weight Connection Cable option 6m PVC, 2 m PU cable Tube length 45, (30. 60 mm under consult) Housing options 6m PVC, 2 m PU cable 45, (30. 60 mm under consult) GX, GT GX, GT Code Electrical connections NPN-E BN BK BU NO PNP-E2 BN BK BU GM nickel plated brass and lateral led GX stainless steel and backside led GT PTFE plated brass and backside led 30 30 mm tube length (under consult) Cable Color 45 45 mm tube length (standard) BN - brown / BU - blue 60 60 mm tube length (option) + 10 - 30Vdc - + 10 - 30Vdc - Housing BK - black NO Dimensions 45 13 .3 45 d l le e ra la t x4 x1 M8 Inductive Line 6.6 13 .9 d l le e ra l at 4 Ø x1 M8 SW 13 12 SW 13 x4 14 1.5 1 3 PS - INDUCTIVE STANDARD LINE M8 3-Wire DC Connector NO - NPN PS1,5-8GI45-E-V1 PS2-8GI45-E-V1 PS1,5-8GM45-E-V8 PS2-8GM45-E-V8 NO - PNP PS1,5-8GI45-E2-V1 PS2-8GI45-E2-V1 PS1,5-8GM45-E2-V8 PS2-8GM45-E2-V8 15 16 17 18 Nominal sensing distance 1.5 mm 2 mm 1.5 mm 2 mm Operating distance 1.21mm 1.62 mm 1.21 mm 1.62 mm Mounting flush non-flush flush non-flush Hysteresis 5% 5% 5% 5% < 0.01 mm < 0.01 mm < 0.01 mm< 0.01 mm 8 x 8 mm 8 x 8 mm 8 x 8 mm 8 x 8 mm 10 to 30 Vdc 10 to 30 Vdc 10 to 30 Vdc 10 to 30 Vdc Drawing Repeatability Standard target Operating voltage range Ripple ± 10 % ± 10 % ± 10 % ± 10 % Max. switching current 100 mA 100 mA 100 mA 100 mA Current consumption ≤10 mA ≤ 10 mA ≤ 10 mA ≤ 10 mA Output voltage drop <2V <2V <2V <2V Max. switching frequency 1 kHz 600 Hz 1 kHz 600 Hz Protection circuit reversal and short-circuit reversal and short-circuit reversal and short-circuit reversal and short-circuit Output indicator 4 microled 4 microled 4 microled 4 microled Operating temperature range Protection class Weight - 25oC to + 70oC - 25oC to + 70oC - 25oC to + 70oC IP 67 IP 67 IP 67 IP 67 20g 20g 15g 15g 4-pin connector 4-pin connector 3-pin connector 3-pin connector Tube length 45, 60 mm(option) 45, 60 mm(option) 45, 60 mm(option) 45, 60 mm(option) GX, GT GX, GT GX, GT GX, GT Electrical connections (1) V1 Connector V8 Connector 2* + (4) (2*) 10 - 30Vdc (3) NO PNP-E2 - 25oC Connection Housing options NPN-E to + 70oC 1 - (1) 3 + (4) (2*) 10 - 30Vdc (3) - Code Housing GM nickel plated brass and lateral led GI nickel plated brass and backside led GX stainless steel and backside led GT PTFE plated brass and backside led 45 45 mm tube length (standard) 60 60 mm tube length (option) NO Dimensions D LE LE D 20 20 45 45 4 4 x1 M8 15 1.6 .6 Ø6 x1 M8 SW x4 13 SW 13 x4 16 17 18 Inductive Line PS - INDUCTIVE STANDARD LINE M12 NAMUR DC Cable NAMUR PS2-12GM50-N PS4-12GM50-N 19 20 2 mm 4 mm 1.62 mm 3.24 mm Mounting flush non-flush Hysteresis 5% 5% ( DIN 19324 ) Drawing Nominal sensing distance Operating distance < 0.01 mm < 0.01 mm Standard target Repeatability 12 x 12 mm 12 x 12 mm Operating voltage range 7 to 12 Vdc 7 to 12 Vdc 8 Vdc ± 5 % 8 Vdc ± 5 % ±5% ±5% Current consumption on state ≤ 1 mA ≤ 1 mA Current consumption off state ≥ 3 mA ≥ 3 mA Max. cable impedance 100 Ω 100 Ω Max. switching frequency 800 Hz 400 Hz --- --- - 25oC to + 100oC - 25oC to + 100oC Protection class IP 67 IP 67 Weight 110g 110g 2 m PVC cable,2 x 22 AWG 2 m PVC cable,2 x 22 AWG 6 m PVC cable 6 m PVC cable 50 mm 50 mm GP, GX, GT GP, GX, GT Cepel Ex-015 / 98 Cepel Ex-015 / 98 Nominal voltage Ripple Output indicator Operating temperature range Connection Cable options Tube length Housing options Ex Certified Code Electrical connections NAMUR SENSOR AMPLIFIER BN BU (-) Exi GM nickel plated brass and lateral led GP thermoplastic polyester with fiberglass and backside led GX stainless steel and backside led Cable Color GT PTFE plated brass and backside led BN - brown - positive 50 50 mm tube length (standard) (+) 8Vdc Housing BU - blue - negative NOTE : WITHOUT LED Dimensions 8 Ø 19 Inductive Line 20 1.7 PS - INDUCTIVE STANDARD LINE M12 3-Wire DC Cable or Connector NO - NPN PS2-12GI50-E PS4-12GI50-E PS2-12GI50-E-V1 PS4-12GI50-E-V1 NO - PNP PS2-12GI50-E2 PS4-12GI50-E2 PS2-12GI50-E2-V1 PS4-12GI50-E2-V1 21 22 23 24 2 mm 4 mm 2 mm 4 mm 1.62 mm 3.24 mm 1.62 mm 3.24 mm Mounting flush non-flush flush non-flush Hysteresis 5% 5% 5% 5% < 0.01 mm < 0.01 mm < 0.01 mm < 0.01 mm 12 x 12 mm 12 x 12 mm 12 x 12 mm 12 x 12 mm 10 to 30 Vdc 10 to 30 Vdc 10 to 30 Vdc 10 to 30 Vdc Drawing Nominal sensing distance Operating distance Repeatability Standard target Operating voltage range Ripple ± 10 % ± 10 % ± 10 % ± 10 % Max. switching current 200 mA 200 mA 200 mA 200 mA Current consumption ≤10 mA ≤10 mA ≤10 mA ≤10 mA <2V <2V <2V <2V 800 Hz 400 Hz 800 Hz 400 Hz reversal and short-circuit reversal and short-circuit reversal and short-circuit reversal and short-circuit backside led backside led 4 microled 4 microled Output voltage drop Max. switching frequency Circuit protection Output indicator Operating temperature range - 25oC to + 70oC - 25 oC to + 70 oC - 25 oC to + 70 oC IP 67 IP 67 IP 67 IP 67 Weight 110g 110g 25g 25g 2 m PVC cable,3 x 25 AWG 2 m PVC cable,3 x 25 AWG 4-pin connector 4-pin connector 6m PVC, 2 m PU cable 6m PVC, 2 m PU cable -- -- 50, 70 mm(option) 50, 70 mm(option) 50, 70 mm(option) 50, 70 mm(option) GX, GT, GP GX, GT, GP GX, GT, GP GX, GT, GP Cable options Tube length Housing options Electrical connections BN(1) BK(4) BU(3) NO PNP-E2 to + 70 oC Protection class Connection NPN-E - 25 oC BN(1) BK(4) BU(3) V1 Connector Code GI + 10 - 30Vdc - Cable Color + 10 - 30Vdc BN - brown / BU - blue BK - black - NO Housing nickel plated brass and backside led GX stainless steel and backside led GT PTFE plated brass and backside led GP thermoplastic polyester with fiberglass and backside led 50 50 mm tube length (standard) 70 70 mm tube length (option) Dimensions 8 Ø 21 1.8 22 23 24 Inductive Line PS - INDUCTIVE STANDARD LINE M12 4-Wire DC Cable or Connector NO + NC - NPN PS2-12GI60-A PS4-12GI60-A PS2-12GI60-A-V1 PS4-12GI60-A-V1 NO + NC - PNP PS2-12GI60-A2 PS4-12GI60-A2 PS2-12GI60-A2-V1 PS4-12GI60-A2-V1 25 26 27 28 2 mm 4 mm 2 mm 4 mm 1.62 mm 3.24 mm 1.62 mm 3.24 mm Mounting flush non-flush flush non-flush Hysteresis 5% 5% 5% 5% < 0.01 mm < 0.01 mm < 0.01 mm < 0.01 mm 12 x 12 mm 12 x 12 mm 12 x 12 mm 12 x 12 mm Drawing Nominal sensing distance Operating distance Repeatability Standard target Operating voltage range 10 to 30 Vdc 10 to 30 Vdc 10 to 30 Vdc 10 to 30 Vdc Ripple ± 10 % ± 10 % ± 10 % ± 10 % Max. output current 200 mA 200 mA 200 mA 200 mA Current consumption ≤15 mA ≤ 15 mA ≤ 15 mA ≤ 15 mA <2V <2V <2V <2V Output voltage drop Max. switching frequency 800 Hz 400 Hz 800 Hz 400 Hz Protection circuit reversal and short-circuit reversal and short-circuit reversal and short-circuit reversal and short-circuit Output indicator backside led backside led 4 microled 4 microled - 25oC to + 70 oC - 25 oC to + 70 oC - 25 oC to + 70 oC - 25 oC to + 70 oC Protection class IP 67 IP 67 IP 67 IP 67 Weight 110g 110g 25g 25g 2 m PVC cable 2 m PVC cable 4-pin connector 4-pin connector 6m PVC, 2 m PU cable 6m PVC, 2 m PU cable -- -- 60, 70 mm(option) 60, 70 mm(option) 60, 70 mm(option) 60, 70 mm(option) GX, GT, GP GX, GT, GP GX, GT, GP GX, GT, GP Operating temperature range Connection Cable options Tube length Housing options V1 Connector Electrical connections Code GI PNP-A2 BN(1) + WH(2) BU(3) stainless steel and backside led GT PTFE plated brass and backside led thermoplastic polyester with fiberglass and backside led Cable Color 60 60 mm tube length (standard) BN - brown / BU - blue 70 70 mm tube length (option) 10 - 30Vdc - nickel plated brass and backside led GX GP 8 BK(4) Housing BK - black / WH - white NO+NC Dimensions Ø 8 Ø 25 Inductive Line 26 27 28 1.9 PS - INDUCTIVE STANDARD LINE M12 2-Wire DC Cable or Connector NO PS2-12GI50-N4 PS4-12GI50-N4 PS2-12GI50-N4-V1 PS4-12GI50-N4-V1 NC PS2-12GI50-N5 PS4-12GI50-N5 PS2-12GI50-N5-V1 PS4-12GI50-N5-V1 29 30 31 32 2 mm 4 mm 2 mm 4 mm 1.62 mm 3.24 mm 1.62 mm 3.24 mm Mounting flush non-flush flush non-flush Hysteresis 5% 5% 5% 5% < 0.01 mm < 0.01 mm < 0.01 mm < 0.01 mm 12 x 12 mm 12 x 12 mm 12 x 12 mm 12 x 12 mm 10 to 60 Vdc 10 to 60 Vdc 10 to 60 Vdc 10 to 60 Vdc Drawing Nominal sensing distance Operating distance Repeatability Standard target Operating voltage range Ripple ± 10 % ± 10 % ± 10 % ± 10 % Max. switching current 100 mA 100 mA 100 mA 100 mA Residual load current < 2.5mA < 2.5mA < 2.5mA < 2.5mA Min. load current 5 mA 5 mA 5 mA 5 mA Output voltage drop <5V <5V <5V <5V 500 Hz 300 Hz 500 Hz 300 Hz Protection circuit reversal and short-circuit reversal and short-circuit reversal and short-circuit reversal and short-circuit Output indicator backside led backside led 4 microled 4 microled - 25oC to + 70 oC - 25oC to + 70oC - 25oC to + 70oC - 25oC to + 70oC Protection class IP 67 IP 67 IP 67 IP 67 Weight 110g 110g 25g 25g 2 m PVC cable,2 x 25 AWG 2 m PVC cable,2 x 25 AWG 4-pin connector 4-pin connector 6m PVC, 2 m PU cable 6m PVC, 2 m PU cable --- --- 50, 70 mm(option) 50, 70 mm(option) 50, 70 mm(option) 50, 70 mm(option) GX, GT, GP GX, GT, GP GX, GT, GP GX, GT, GP Max. switching frequency Operating temperature range Connection Cable options Tube length Housing options Electrical connections N4 BN(1) V1 Connector Code GI + 10 - 60Vdc BU(4) NO N5 BN(1) - Cable Color + 10 - 60Vdc BU(2) BN - brown / BU - blue - Housing nickel plated brass and backside led GX stainless steel and backside led GT PTFE plated brass and backside led GP thermoplastic polyester with fiberglass and backside led 50 50 mm tube length (standard) 70 70 mm tube length (option) NC Dimensions 29 1.10 30 31 32 Inductive Line PS - INDUCTIVE STANDARD LINE M12 2-Wire + GND AC Cable or Connector NO PS2-12GI60-WA PS4-12GI60-WA PS2-12GM60-WA-V13 PS4-12GM60-WA-V13 NC PS2-12GI60-WF PS4-12GI60-WF PS2-12GM60-WF-V13 PS4-12GM60-WF-V13 33 34 35 36 2 mm 4 mm 2 mm 4 mm 1.62 mm 3.24 mm 1.62 mm 3.24 mm Mounting flush non-flush flush non-flush Hysteresis 5% 5% 5% 5% < 0.01 mm < 0.01 mm < 0.01 mm < 0.01 mm 12 x 12 mm 12 x 12 mm 12 x 12 mm 12 x 12 mm 20 to 250 Vac 20 to 250 Vac 20 to 250 Vac 20 to 250 Vac 50 or 60 Hz 50 or 60 Hz 50 or 60 Hz 50 or 60 Hz 500 mA 500 mA 500 mA 500 mA 1A 1A 1A 1A < 3 mA < 3 mA < 3 mA < 3 mA Drawing Nominal sensing distance Operating distance Repeatability Standard target Operating voltage range Operating frenquency Max. switching current Inrush current( t<20ms/ f< 1Hz) Residual load current Min. load current 5 mA 5 mA 5 mA 5 mA Output voltage drop <5V <5V <5V <5V Max. switching frequency 10 Hz 10 Hz 10 Hz 10 Hz backside led backside led lateral led Output indicator Operating temperature range - 25oC 70oC to + - 25oC to + lateral led 70oC - 25oC to + 70oC IP 67 IP 67 IP 67 IP 67 Weight 110g 110g 25g 25g 2 m PVC cable,3 x 25 AWG 2 m PVC cable,3 x 25 AWG 3-pin connector 3-pin connector 6m PVC, 2 m PU cable 6m PVC, 2 m PU cable --- --- 60, 70 mm(option) 60, 70 mm(option) 60, 70 mm(option) 60, 70 mm(option) GX, GT, GP GX, GT, GP GX, GT, GP GX, GT, GP Connection Tube length Housing options V13 Connector Electrical connections GM GI 20 - 250 Vac 2 BU(3) BN(2) GN/YE(1) Code 1 BN(2) GN/YE(1) NO WF to + 70oC Protection class Cable options WA - 25oC 3 BU(3) nickel plated brass and lateral led nickel plated brass and backside led GX stainless steel and backside led GT PTFE plated brass and backside led Cable Color GP thermoplastic polyester with fiberglass and backside led BN - brown / BU - blue 60 60 mm tube length (standard) GN / YE - green / yellow 70 70 mm tube length (option) 20 - 250Vac NC Housing Dimensions 70 70 8 8 Ø Ø 33 Inductive Line 34 35 36 1.11 PS - INDUCTIVE STANDARD LINE M18 NAMUR DC Cable NAMUR PS5-18GM50-N PS8-18GM50-N 37 38 5 mm 8 mm 4.05 mm 6.48 mm Mounting flush non-flush Hysteresis 5% 5% < 0.01 mm < 0.01 mm Standard target 18 x 18 mm 24 x 24 mm Operating voltage range 7 to 12 Vdc 7 to 12 Vdc 8 Vdc ± 5 % 8 Vdc ± 5 % ±5% ±5% Activated sensor current ≤ 1 mA ≤ 1 mA Deactivated sensor current ≥ 3 mA ≥ 3 mA Max. cable impedance 100 Ω 100 Ω Max. switching frequency 500 Hz 200 Hz ( DIN 19324 ) Drawing Nominal sensing distance Operating distance Repeatability Nominal voltage Ripple Output indicator Operating temperature range --- --- 25oC to + 100oC - 25oC to + 100oC Protection class IP 67 IP 67 Weight 150g 150g 2 m PVC cable,2 x 20 AWG 2 m PVC cable,2 x 20 AWG 6 m PVC cable 6 m PVC cable 50 mm 50 mm GP, GX, GT GP, GX, GT Cepel Ex - 017 / 98X Cepel Ex - 017 / 98X Connection Cable options Tube length Housing options Ex Certified Electrical connections NAMUR SENSOR Code AMPLIFIER BN (+) 8Vdc BU (-) Cable Color Exi Housing GM nickel plated brass GP thermoplastic polyester with fiberglass 50 50 mm tube length (standard) BN - brown - positive BU - blue - negative NOTE : WITHOUT LED Dimensions Ø 37 1.12 38 Inductive Line PS - INDUCTIVE STANDARD LINE M18 3-Wire DC Cable or Connector NO - NPN PS5-18GI50-E PS8-18GI50-E PS5-18GI50-E-V1 PS8-18GI50-E-V1 NO - PNP PS5-18GI50-E2 PS8-18GI50-E2 PS5-18GI50-E2-V1 PS8-18GI50-E2-V1 39 40 41 42 5 mm 8 mm 5 mm 8 mm 4.05 mm 6.48 mm 4.05 mm 6.48 mm Mounting flush non-flush flush non-flush Hysteresis 5% 5% 5% 5% < 0.01 mm < 0.01 mm < 0.01 mm < 0.01 mm 18 x 18 mm 24 x 24 mm 18 x 18 mm 24 x 24 mm Drawing Nominal sensing distance Operating distance Repeatability Standard target Operating voltage range 10 to 30 Vdc 10 to 30 Vdc 10 to 30 Vdc 10 to 30 Vdc Ripple ± 10 % ± 10 % ± 10 % ± 10 % Max. switching current 200 mA 200 mA 200 mA 200 mA Current consumption ≤10 mA ≤10 mA ≤10 mA ≤10 mA <2V <2V <2V <2V 500 Hz 200 Hz 500 Hz 200 Hz reversal and short-circuit reversal and short-circuit reversal and short-circuit reversal and short-circuit backside led backside led 4 microled 4 microled - 25oC to + 70oC - 25oC to + 70oC - 25oC to + 70oC - 25oC to + 70oC Protection class IP 67 IP 67 IP 67 IP 67 Weight 150g 150g 55g 55g 2 m PVC cable,3 x 22 AWG 2 m PVC cable,3 x 22 AWG 4-pin connector 4-pin connector 6m PVC, 2 m PU cable 6m PVC, 2 m PU cable --- --- 50, 70 mm(option) 50, 70 mm(option) 50, 70 mm(option) 50, 70 mm(option) GX, GT, GP GX, GT, GP GX, GT, GP GX, GT, GP Output voltage drop Max. switching frequency Circuit protection Output indicator Operating temperature range Connection Cable options Tube length Housing options V1 Connector Electrical connections NPN-E BN(1) BK(4) BU(3) NO PNP-E2 BN(1) BK(4) BU(3) Code GI + 10 - 30Vdc stainless steel and backside led GT PTFE plated brass and backside led thermoplastic polyester with fiberglass and backside led Cable Color 50 50 mm tube length (standard) BN - brown / BU - blue 70 70 mm tube length (option) 10 - 30Vdc - nickel plated brass and backside led GX GP - + Housing BK - black NO Dimensions 39 Inductive Line 40 41 42 1.13 PS - INDUCTIVE STANDARD LINE M18 4-Wire DC Cable or Connector NO + NC - NPN PS5-18GI50-A PS8-18GI50-A PS5-18GI50-A-V1 PS8-18GI50-A-V1 NO + NC - PNP PS5-18GI50-A2 PS8-18GI50-A2 PS5-18GI50-A2-V1 PS8-18GI50-A2-V1 43 44 45 46 5 mm 8 mm 5 mm 8 mm 4.05 mm 6.48 mm 4.05 mm 6.48 mm Mounting flush non-flush flush non-flush Hysteresis 5% 5% 5% 5% < 0.01 mm < 0.01 mm < 0.01 mm < 0.01 mm 18 x 18 mm 24 x 24 mm 18 x 18 mm 24 x 24mm 10 to 30 Vdc 10 to 30 Vdc 10 to 30 Vdc 10 to 30 Vdc Drawing Nominal sensing distance Operating distance Repeatability Standard target Operating voltage range Ripple ± 10 % ± 10 % ± 10 % ± 10 % Max. switching current 200 mA 200 mA 200 mA 200 mA Current consumption ≤15 mA ≤15 mA ≤15 mA ≤15 mA <2V <2V <2V <2V 500 Hz 200 Hz 500 Hz 200 Hz reversal and short-circuit backside led reversal and short-circuit backside led reversal and short-circuit 4 microled reversal and short-circuit 4 microled - 25oC to + 70oC - 25oC to + 70oC - 25oC to + 70oC - 25oC to + 70oC Protection class IP 67 IP 67 IP 67 IP 67 Weight 150g 150g 55g 55g 2 m PVC cable,4 x 22 AWG 2 m PVC cable,4 x 22 AWG 4-pin connector 4-pin connector 6m PVC, 2m PU cable 6m PVC, 2 m PU cable --- --- 50, 70 mm(option) 50, 70 mm(option) 50, 70 mm(option) 50, 70 mm(option) GX, GT, GP GX, GT, GP GX, GT, GP GX, GT, GP Output voltage drop Max. switching frequency Circuit protection Output indicator Operating temperature range Connection Cable options Tube length Housing options Electrical connections V1 Connector Code GI PNP-A2 BN(1) Cable Color + BK(4) WH(2) BU(3) 10 - 30Vdc BN - brown / BU - blue - Housing nickel plated brass and backside led GX stainless steel and backside led GT PTFE plated brass and backside led GP thermoplastic polyester with fiberglass and backside led 50 50 mm tube length (standard) 70 70 mm tube length (option) BK - black / WH - white NO+NC Dimensions Ø Ø 43 1.14 44 45 46 Inductive Line PS - INDUCTIVE STANDARD LINE M18 2-Wire DC Cable or Connector NO PS5-18GI50-N4 PS8-18GI50-N4 PS5-18GI50-N4-V1 PS8-18GI50-N4-V1 NC PS5-18GI50-N5 PS8-18GI50-N5 PS5-18GI50-N5-V1 PS8-18GI50-N5-V1 47 48 49 50 5 mm 8 mm 5 mm 8 mm 4.05 mm 6.48 mm 4.05 mm 6.48 mm Mounting flush non-flush flush non-flush Hysteresis 5% 5% 5% 5% < 0.01 mm < 0.01 mm < 0.01 mm < 0.01 mm 18 x 18 mm 24 x 24 mm 18 x 18 mm 24 x 24 mm Drawing Nominal sensing distance Operating distance Repeatability Standard target Operating voltage range 10 to 60 Vdc 10 to 60 Vdc 10 to 60 Vdc 10 to 60 Vdc Ripple ± 10 % ± 10 % ± 10 % ± 10 % Max. switching current 100 mA 100 mA 100 mA 100 mA < 2.5mA < 2.5mA < 2.5mA < 2.5mA Min. load current 5 mA 5 mA 5 mA 5 mA Output voltage drop <5V <5V <5V <5V 500 Hz 300 Hz 500 Hz 300 Hz Protection circuit reversal and short-circuit reversal and short-circuit reversal and short-circuit reversal and short-circuit Output indicator backside led backside led 4 microled 4 microled Residual load current Max. switching frequency Operating temperature range - 25oC to + 70 - 25oC to + 70oC to + 70oC - 25oC to + 70oC IP 67 IP 67 IP 67 IP 67 Weight 150g 150g 55g 55g 2 m PVC cable,2 x 22 AWG 2 m PVC cable,2 x 22 AWG 4-pin connector 4-pin connector 6m PVC, 2 m PU cable 6m PVC, 2 m PU cable --- --- 50, 70 mm(option) 50, 70 mm(option) 50, 70 mm(option) 50, 70 mm(option) GX, GT, GP GX, GT, GP GX, GT, GP GX, GT, GP Connection Tube length Housing options V1 Connector Electrical connections BN(1) Code GI + 10 - 60Vdc BU(4) NO N5 - 25oC Protection class Cable options N4 oC BN(1) - stainless steel and backside led GT PTFE plated brass and backside led thermoplastic polyester with fiberglass and backside led Cable Color 50 50 mm tube length (standard) BN - brown / BU - blue 70 70 mm tube length (option) 10 - 60Vdc BU(2) nickel plated brass and backside led GX GP - + Housing NC Dimensions Ø Ø 47 Inductive Line 48 49 50 1.15 PS - INDUCTIVE STANDARD LINE M18 2-Wire + GND AC Cable or Connector NO PS5-18GI50-WA PS8-18GI50-WA PS5-18GM50-WA-V13 PS8-18GM50-WA-V13 NC PS5-18GI50-WF PS8-18GI50-WF PS5-18GM50-WF-V13 PS8-18GM50-WF-V13 51 52 53 54 5 mm 8 mm 5 mm 8 mm 4.05 mm 6.48 mm 4.05 mm 6.48 mm Mounting flush non-flush flush non-flush Hysteresis 5% 5% 5% 5% < 0.01 mm < 0.01 mm < 0.01 mm < 0.01 mm 18 x 18 mm 24 x 24 mm 18 x 18 mm 24 x 24 mm 20 to 250 Vac 20 to 250 Vac 20 to 250 Vac 20 to 250 Vac Drawing Nominal sensing distance Operating distance Repeatability Standard target Operating voltage range 50 or 60 Hz 50 or 60 Hz 50 or 60 Hz 50 or 60 Hz Max. switching current Operating frenquency 500 mA 500 mA 500 mA 500 mA Inrush current( t<20ms/ f< 1Hz) Residual load current 4A < 3 mA 4A < 3mA 4A < 3 mA 4A < 3 mA Min. load current 5 mA 5 mA 5 mA 5 mA Output voltage drop <5V <5V <5V <5V Max. switching frequency 10 Hz 10 Hz 10 Hz 10 Hz backside led backside led lateral led Output indicator Operating temperature range - 25oC to + 70oC - 25oC to + lateral led 70oC - 25oC to + 70oC IP 67 IP 67 IP 67 IP 67 Weight 150g 150g 55g 55g 2 m PVC cable,3 x 25 AWG 2 m PVC cable,3 x 25 AWG 3-pin connector 3-pin connector 6m PVC, 2 m PU cable 6m PVC, 2 m PU cable --- --- 50, 70 mm(option) 50, 70 mm(option) 50, 70 mm(option) 50, 70 mm(option) GX, GT, GP GX, GT, GP GX, GT, GP GX, GT, GP Cable options Tube length Housing options V13 Connector Electrical connections GM GI 20 - 250 Vac 2 BU(3) BN(2) GN/YE(1) Code 1 BN(2) GN/YE(1) NO WF to + 70oC Protection class Connection WA - 25oC 3 BU(3) nickel plated brass and lateral led nickel plated brass and backside led GX stainless steel and backside led GT PTFE plated brass and backside led Cable Color GP thermoplastic polyester with fiberglass and backside led BN - brown / BU - blue 50 50 mm tube length (standard) GN / YE - green / yellow 70 70 mm tube length (option) 20 - 250Vac NC Housing Dimensions Ø 6 Ø1 .5 51 1.16 52 53 54 Inductive Line PS - INDUCTIVE STANDARD LINE M18 2-Wire + GND AC/DC Cable or Connector NO PS5-18GI70-UA PS8-18GI70-UA PS5-18GM70-UA-V13 PS8-18GM70-UA-V13 NC PS5-18GI70-UF PS8-18GI70-UF PS5-18GM70-UF-V13 PS8-18GM70-UF-V13 55 56 57 58 5 mm 8 mm 5 mm 8 mm 4.05 mm 6.48 mm 4.05 mm 6.48 mm Mounting flush non-flush flush non-flush Hysteresis 5% 5% 5% 5% < 0.01 mm < 0.01 mm < 0.01 mm < 0.01 mm 18 x 18 mm 24 x 24 mm 18 x 18 mm 24 x 24 mm 20 to 250 Vac / Vdc 20 to 250 Vac / Vdc 20 to 250 Vac / Vdc 20 to 250 Vac / Vdc 50 or 60 Hz 50 or 60 Hz 50 or 60 Hz 50 or 60 Hz 500 mA 500 mA 500 mA 500 mA 4A 4A 4A 4A < 3 mA 5 mA < 3mA 5 mA < 3 mA 5 mA < 3 mA 5 mA Output voltage drop <5V <5V <5V <5V Max. switching frequency 25 Hz 25 Hz 25 Hz 25 Hz backside led backside led lateral led Drawing Nominal sensing distance Operating distance Repeatability Standard target Operating voltage range Operating frenquency Max. switching current Inrush current( t<20ms/ f< 1Hz) Residual load current Min. load current Output indicator Operating temperature range - 25oC to + 70 oC - 25oC to + 70oC - 25oC to + lateral led 70oC - 25oC to + 70oC Protection class IP 67 IP 67 IP 67 IP 67 Weight 150g 150g 55g 55g 2 m PVC cable,3 x 22 AWG 2 m PVC cable,3 x 22 AWG 3-pin connector 3-pin connector Connection Cable options 6m PVC, 2 m PU cable 6m PVC, 2 m PU cable -- -- Tube length 70 mm 70 mm 70 mm 70 mm( Housing options GX, GT GX, GT GX, GT GX, GT V13 Connector Electrical connections Code 1 GM GI 2 3 Cable Colors Housing nickel plated brass and lateral led nickel plated brass and backside led GX stainless steel and backside led GT PTFE plated brass and backside led 70 70 mm tube length (option) BN - brown / BU - blue GN / YE - green / yellow Dimensions 70 70 16 Ø 6 Ø1 .5 55 Inductive Line 56 57 58 1.17 PS - INDUCTIVE STANDARD LINE M18 3-Wire AC Cable NO PS5-18GI50-3WA PS8-18GI50-3WA NC PS5-18GI50-3WF PS8-18GI50-3WF 59 60 5 mm 8 mm 4.05 mm 6.48 mm Mounting flush non-flush Hysteresis 5% 5% < 0.01 mm < 0.01 mm 18 x 18 mm 24 x 24 mm 20 to 250 Vac 20 to 250 Vac Drawing Nominal sensing distance Operating distance Repeatability Standard target Operating voltage range 50 or 60 Hz 50 or 60 Hz Max. switching current Operating frenquency 500 mA 500 mA Inrush current( t<20ms/ f< 1Hz) Residual load current 4A < 3 mA 4A < 3mA Min. load current 5 mA 5 mA Output voltage drop <5V <5V Max. switching frequency 10 Hz 10 Hz Output indicator Operating temperature range backside led backside led 25oC - 25oC to + 70oC - to + 70oC Protection class IP 67 IP 67 Weight 150g 150g 2 m PVC cable,3 x 25 AWG 2 m PVC cable,3 x 25 AWG 6m PVC, 2 m PU cable 6m PVC, 2 m PU cable 50, 70 mm(option) 50, 70 mm(option) GX, GT, GP GX, GT, GP Connection Cable options Tube length Housing options Code Electrical connections W3A BN BK BU NO W3F BN BK BU GM + GI 20 - 250 Vac - 20 - 250 Vac nickel plated brass and lateral led nickel plated brass and backside led GX stainless steel and backside led GT PTFE plated brass and backside led BN - brown / BU - blue GP thermoplastic polyester with fiberglass and backside led BK - black 50 50 mm tube length (standard) 70 70 mm tube length (option) Cable Colors + Housing - NO Dimensions 70 70 16 Ø 59 1.18 60 Inductive Line PS - INDUCTIVE STANDARD LINE M30 NAMUR DC Cable NAMUR PS10-30GM50-N PS15-30GM50-N 61 62 10 mm 15 mm 8.01 mm 12.15 mm Mounting flush non-flush Hysteresis 5% 5% ( DIN 19324 ) Drawing Nominal sensing distance Operating distance < 0.01 mm < 0.01 mm Standard target Repeatability 30 x 30 mm 45 x 45 mm Operating voltage range 7 to 12 Vdc 7 to 12 Vdc 8 Vdc ± 5% 8 Vdc8 Vdc ± 5% ±5% ±5% Activated sensor current ≤ 1 mA ≤ 1 mA Deactivated sensor current ≥ 3 mA ≥ 3 mA Max. cable impedance 100 Ω 100 Ω Max. switching frequency 300 Hz 100 Hz --- --- - 25 oC to + 100 oC - 25 oC to + 100 oC Protection class IP 67 IP 67 Weight 205g 205g 2 m PVC cable,2x20 AWG 2 m PVC cable, 2 x 20 AWG 6 m PVC cable 6 m PVC cable 50 mm 50 mm GP,GX, GT GP,GX, GT Cepel Ex - 018 / 98X Cepel Ex - 018 / 98X Nominal voltage Ripple Output indicator Operating temperature range Connection Cable options Tube length Housing options Ex Certified Code Electrical connections NAMUR SENSOR AMPLIFIER BN BU Exi (-) GM nickel plated brass GP thermoplastic polyester with fiberglass GX stainless steel and backside led Cable Colors GT PTFE plated brass and backside led BN - brown - positive 50 50 mm tube length (standard) (+) 8Vdc Housing BU - blue - negative NOTE : WITHOUT LED Dimensions 50 18 Inductive Line 1.5 0x 61 Ø x5 M3 1.5 0x M3 SW 36 SW x5 36 62 1.19 PS - INDUCTIVE STANDARD LINE M30 3-Wire DC Cable or Connector NO - NPN PS10-30GI50-E PS15-30GI50-E PS10-30GI50-E-V1 PS15-30GI50-E-V1 NO - PNP PS10-30GI50-E2 PS15-30GI50-E2 PS10-30GI50-E2-V1 PS15-30GI50-E2-V1 63 64 65 66 Nominal sensing distance 10 mm 15 mm 10 mm 15 mm Operating distance 8.1 mm 12.15 mm 8.1 mm 12.15 mm Mounting flush non-flush flush non-flush Hysteresis 5% 5% 5% 5% < 0.01 mm < 0.01 mm < 0.01 mm < 0.01 mm 30 x 30 mm 45 x 45 mm 30 x 30 mm 45 x 45 mm 10 to 30 Vdc 10 to 30 Vdc 10 to 30 Vdc 10 to 30 Vdc Drawing Repeatability Standard target Operating voltage range Ripple ± 10 % ± 10 % ± 10 % ± 10 % Max. switching current 200 mA 200 mA 200 mA 200 mA Current consumption ≤10 mA ≤ 10 mA ≤ 10 mA ≤ 10 mA <2V <2V <2V <2V 300 Hz 100 Hz 300 Hz 100 Hz reversal and short-circuit reversal and short-circuit reversal and short-circuit reversal and short-circuit backside led backside led 4 microled 4 microled Output voltage drop Max. switching frequency Circuit protection Output indicator Operating temperature range - 25oC to + 70oC - 25 oC to + 70 oC - 25 oC to + 70 oC IP 67 IP 67 IP 67 IP 67 Weight 205g 205g 125g 125g 2 m PVC cable,3 x 20 AWG 2 m PVC cable,3 x 20 AWG 4-pin M12 connector 4-pin M12 connector 6m PVC, 2 m PU cable 6m PVC, 2 m PU cable --- --- 50, 70 mm(option) 50, 70 mm(option) 50, 70 mm(option) 50, 70 mm(option) GX, GT, GP GX, GT, GP GX, GT, GP GX, GT, GP Cable options Tube length Housing options Electrical connections BN(1) BK(4) BU(3) NO PNP-E2 to + 70 oC Protection class Connection NPN-E - 25oC BN(1) BK(4) BU(3) V1 Connector Code GI + 10 - 30Vdc - Cable Colors + 10 - 30Vdc BN - brown / BU - blue - Housing nickel plated brass and backside led GX stainless steel and backside led GT PTFE plated brass and backside led GP thermoplastic polyester with fiberglass and backside led 50 50 mm tube length (standard) 70 70 mm tube length (option) BK - black NO Dimensions Ø 63 1.20 64 65 66 Inductive Line PS - INDUCTIVE STANDARD LINE M30 4-Wire DC Cable or Connector NO + NC - NPN PS10-30GI50-A PS15-30GI50-A PS10-30GI50-A-V1 PS15-30GI50-A-V1 NO + NC - PNP PS10-30GI50-A2 PS15-30GI50-A2 PS10-30GI50-A2-V1 PS15-30GI50-A2-V1 67 68 69 70 Nominal sensing distance 10 mm 15 mm 10 mm 15 mm Operating distance 8.1 mm 12.15 mm 8.1 mm 12.15 mm Mounting flush non-flush flush non-flush Hysteresis 5% 5% 5% 5% < 0.01 mm < 0.01 mm < 0.01 mm < 0.01 mm 30 x 30 mm 45 x 45 mm 30 x 30 mm 45 x 45 mm Drawing Repeatability Standard target Operating voltage range 10 to 30 Vdc 10 to 30 Vdc 10 to 30 Vdc 10 to 30 Vdc Ripple ± 10 % ± 10 % ± 10 % ± 10 % Max. switching current 200 mA 200 mA 200 mA 200 mA Current consumption ≤15 mA ≤ 15 mA ≤ 15 mA ≤ 15 mA <2V <2V <2V <2V 300 Hz 100 Hz 300 Hz 100 Hz reversal and short-circuit reversal and short-circuit reversal and short-circuit reversal and short-circuit backside led backside led 4 microled 4 microled - 25oC to + 70 oC - 25oC to + 70oC - 25oC to + 70oC - 25oC to + 70oC Protection class IP 67 IP 67 IP 67 IP 67 Weight 205g 205g 125g 125g 2 m PVC cable,3 x 20 AWG 2 m PVC cable,3 x 20 AWG 4-pin M12 connector 4-pin M12 connector 6m PVC, 2 m PU cable 6m PVC, 2 m PU cable --- --- 50, 70 mm(option) 50, 70 mm(option) 50, 70 mm(option) 50, 70 mm(option) GX, GT, GP GX, GT, GP GX, GT, GP GX, GT, GP Output voltage drop Max. switching frequency Circuit protection Output indicator Operating temperature range Connection Cable options Tube length Housing options V1 Connector Electrical connections Code GI PNP-A2 BN(1) + BK(4) WH(2) BU(3) nickel plated brass and backside led GX stainless steel and backside led GT PTFE plated brass and backside led GP thermoplastic polyester with fiberglass and backside led Cable Colors 50 50 mm tube length (standard) BN - brown / BU - blue 70 70 mm tube length (option) 10 - 30Vdc - Housing BK - black / WH - white NO+NC Dimensions Ø 67 Inductive Line 68 69 70 1.21 PS - INDUCTIVE STANDARD LINE M30 2-Wire DC Cable or Connector NO PS10-30GI50-N4 PS15-30GI50-N4 PS10-30GI50-N4-V1 PS15-30GI50-N4-V1 NC PS10-30GI50-N5 PS15-30GI50-N5 PS10-30GI50-N5-V1 PS15-30GI50-N5-V1 71 72 73 74 Nominal sensing distance 10 mm 15 mm 10 mm 15 mm Operating distance 8.1 mm 12.15 mm 8.1 mm 12.15 mm Mounting flush non-flush flush non-flush Hysteresis 5% 5% 5% 5% < 0.01 mm < 0.01 mm < 0.01 mm < 0.01 mm 30 x 30 mm 45 x 45 mm 30 x 30 mm 45 x 45 mm 10 to 60 Vdc 10 to 60 Vdc 10 to 60 Vdc 10 to 60 Vdc Ripple ± 10 % ± 10 % ± 10 % ± 10 % Max. switching current 100 mA 100 mA 100 mA 100 mA Drawing Repeatability Standard target Operating voltage range < 2.5mA < 2.5mA < 2.5mA < 2.5mA Min. load current 5 mA 5 mA 5 mA 5 mA Output voltage drop <5V <5V <5V <5V 500 Hz 300 Hz 500 Hz 300 Hz reversal and short-circuit reversal and short-circuit reversal and short-circuit reversal and short-circuit backside led backside led 4 microled 4 microled - 25oC to + 70oC - 25oC to + 70oC - 25oC to + 70oC - 25oC to + 70oC Protection class IP 67 IP 67 IP 67 IP 67 Weight 205g 205g 125g 125g 2 m PVC cable,2 x 20 AWG 2 m PVC cable,2 x 20 AWG 4-pin connector 4-pin connector 6m PVC, 2 m PU cable 6m PVC, 2 m PU cable --- --- 50, 70 mm(option) 50, 70 mm(option) 50, 70 mm(option) 50, 70 mm(option) GX, GT, GP GX, GT, GP GX, GT, GP GX, GT, GP Residual load current Max. switching frequency Circuit protection Output indicator Operating temperature range Connection Cable options Tube length Housing options Electrical connections N4 BN(1) V1 Connector Code GI + 10 - 60Vdc BU(4) NO N5 BN(1) - Cable Colors + 10 - 60Vdc BU(2) BN - brown / BU - blue - Housing nickel plated brass and backside led GX stainless steel and backside led GT PTFE plated brass and backside led GP thermoplastic polyester with fiberglass and backside led 50 50 mm tube length (standard) 70 70 mm tube length (option) NC Dimensions Ø 71 1.22 72 73 74 Inductive Line PS - INDUCTIVE STANDARD LINE M30 2-Wire + GND AC Cable or Connector NO PS10-30GI50-WA PS15-30GI50-WA PS10-30GM50-WA-V13 PS15-30GM50-WA-V13 NC PS10-30GI50-WF PS15-30GI50-WF PS10-30GM50-WF-V13 PS15-30GM50-WF-V13 75 76 77 78 Nominal sensing distance 10 mm 15 mm 10 mm 15 mm Operating distance 8.1 mm 12.15 mm 8.1 mm 12.15 mm Mounting flush non-flush flush non-flush Hysteresis 5% 5% 5% 5% < 0.01 mm < 0.01 mm < 0.01 mm < 0.01 mm 30 x 30 mm 45 x 45 mm 30 x 30 mm 45 x 45 mm 20 to 250 Vac 20 to 250 Vac 20 to 250 Vac 20 to 250 Vac 50 or 60 Hz 50 or 60 Hz 50 or 60 Hz 50 or 60 Hz 500 mA 500 mA 500 mA 500 mA 4A 4A 4A 4A < 3 mA 5 mA < 3mA 5 mA < 3 mA 5 mA < 3 mA 5 mA Output voltage drop <5V <5V <5V <5V Max. switching frequency 10 Hz 10 Hz 10 Hz 10 Hz Drawing Repeatability Standard target Operating voltage range Operating frenquency Max. switching current Inrush current( t<20ms/ f< 1Hz) Residual load current Min. load current Output indicator Operating temperature range backside led - 25 oC to + 70 backside led oC - 25 oC to + 70 lateral led oC - 25 oC lateral led to + 70 oC - 25 oC to + 70 oC Protection class IP 67 IP 67 IP 67 IP 67 Weight 205g 205g 125g 125g 2 m PVC cable,2 x 20 AWG 2 m PVC cable,2 x 20 AWG 3-pin connector 3-pin connector Connection Cable options Tube length Housing options 6m PVC, 2 m PU cable 6m PVC, 2 m PU cable --- --- 50, 70 mm(option) 50, 70 mm(option) 50, 70 mm(option) 50, 70 mm(option) GX, GT, GP GX, GT, GP GX, GT, GP GX, GT, GP V13 Connector Electrical connections Code 1 GM GI 2 Housing nickel plated brass and lateral led nickel plated brass and backside led 3 GX stainless steel and backside led GT PTFE plated brass and backside led Cable Colors GP thermoplastic polyester with fiberglass and backside led BN - brown / BU - blue 50 50 mm tube length (standard) GN / YE - green / yellow 70 70 mm tube length (option) Dimensions 86 70 l era la t led 0 M3 Ø .5 x1 75 Inductive Line 76 5 6x .3 XT SE 77 78 1.23 PS - INDUCTIVE STANDARD LINE M30 2-Wire + GND AC/DC Cable or Connector NO PS10-30GI70-UA PS15-30GI70-UA PS10-30GM70-UA-V13 PS15-30GM70-UA-V13 NC PS10-30GI70-UF PS15-30GI70-UF PS10-30GM70-UF-V13 PS15-30GM70-UF-V13 79 80 81 82 Nominal sensing distance 10 mm 15 mm 10 mm 15 mm Operating distance 8.1 mm 12.15 mm 8.1 mm 12.15 mm Mounting flush non-flush flush non-flush Hysteresis 5% 5% 5% 5% < 0.01 mm < 0.01 mm < 0.01 mm < 0.01 mm 30 x 30 mm 45 x 45 mm 30 x 30 mm 45 x 45 mm 20 to 250 Vac / Vdc 20 to 250 Vac / Vdc 20 to 250 Vac / Vdc 20 to 250 Vac / Vdc 50 or 60 Hz 50 or 60 Hz 50 or 60 Hz 50 or 60 Hz 300 mA 300 mA 300 mA 300 mA 4A 4A 4A 4A < 3 mA 5 mA < 3mA 5 mA < 3 mA 5 mA < 3 mA 5 mA Output voltage drop <5V <5V <5V <5V Max. switching frequency 25 Hz 25 Hz 25 Hz 25 Hz backside led backside led lateral led Drawing Repeatability Standard target Operating voltage range Operating frenquency Max. switching current Inrush current( t<20ms/ f< 1Hz) Residual load current Min. load current Output indicator Operating temperature range - 25oC to + 70oC - 25oC to + 70 oC - 25oC lateral led to + 70 oC - 25 oC to + 70 oC Protection class IP 67 IP 67 IP 67 IP 67 Weight 205g 205g 125g 125g 2 m PVC cable,3 x 20 AWG 2 m PVC cable,3 x 20 AWG 4-pin connector 4-pin connector 6m PVC, 2 m PU cable 6m PVC, 2 m PU cable --- --- 70 mm 70 mm 70 mm 70 mm GX, GT, GP GX, GT, GP GX, GT, GP GX, GT, GP Connection Cable options Tube length Housing option V13 Connector Electrical connections Code 1 GM GI 2 3 Housing nickel plated brass and lateral led nickel plated brass and backside led GX stainless steel and backside led GT PTFE plated brass and back led Cable Colors GP thermoplastic polyester with fiberglass and backside led BN - brown / BU - blue 70 70 mm tube length (standard) GN / YE - green / yellow Dimensions le d i de s k c ba l ed id e s k c ba 18 36 x5 79 1.24 Ø x1.5 0 M3 1.5 0x M3 SW SW 36 x5 80 81 82 Inductive Line PS - INDUCTIVE STANDARD LINE M30 2-Wire + GND AC/DC Output protection Cable or Connector NO PS10-30GI70-UZA PS15-30GI70-UZA PS10-30GM70-UZA-V13 PS15-30GM70-UZA-V13 NC PS10-30GI70-UZF PS15-30GI70-UZF PS10-30GM70-UZF-V13 PS15-30GM70-UZF-V13 83 84 85 86 Nominal sensing distance 10 mm 15 mm 10 mm 15 mm Operating distance 8.1 mm 12.15 mm 8.1 mm 12.15 mm Mounting flush non-flush flush non-flush Hysteresis 5% 5% 5% 5% < 0.01 mm < 0.01 mm < 0.01 mm < 0.01 mm 30 x 30 mm 45 x 45 mm 30 x 30 mm 45 x 45 mm 20 to 250 Vac / Vdc 20 to 250 Vac / Vdc 20 to 250 Vac / dc 20 to 250 Vac / dc 50 or 60 Hz 50 or 60 Hz 50 or 60 Hz 50 or 60 Hz 300 mA 300 mA 300 mA 300 mA 4A 4A 4A 4A < 3 mA < 3mA < 3 mA < 3 mA Min. load current 5 mA 5 mA 5 mA 5 mA Output voltage drop Max. switching frequency <5V 25 Hz <5V 25 Hz <5V 25 Hz <5V 25 Hz short-circuit short-circuit short-circuit short-circuit Drawing Repeatability Standard target Operating voltage range Operating frenquency Max. switching current Inrush current( t<20ms/ f< 1Hz) Residual load current Circuit protection Output indicator backside led backside led lateral led lateral led - 25oC to + 70oC - 25oC to + 70oC - 25oC to + 70oC - 25oC to + 70oC Protection class IP 67 IP 67 IP 67 IP 67 Weight 205g 205g 125g 125g 2 m PVC cable,3 x 20 AWG 2 m PVC cable,3 x 20 AWG 4-pin connector 4-pin connector 6m PVC, 2 m PU cable 6m PVC, 2 m PU cable --- --- 70 mm 70 mm 70 mm GX, GT, GP GX, GT, GP GX, GT, GP Operating temperature range Connection Cable options Tube length70 mm Housing options V13 Connector Electrical connections Code 1 GM GI 2 3 GX, GT, GP Housing nickel plated brass and lateral led nickel plated brass and backside led GX stainless steel and backside led GT PTFE plated brass and backside led Cable Colors GP thermoplastic polyester with fiberglass BN - brown / BU - blue 70 70 mm tube length (standard) GN / YE - green / yellow Dimensions le d i de s k c ba l ed id e s k c ba 66 50 18 x5 Inductive Line 36 x5 .5 x1 83 SW 0 M3 36 Ø x1.5 0 M3 1.5 0x M3 SW 84 SW led ral e t la x5 36 85 86 1.25 PS - INDUCTIVE STANDARD LINE M30 3-Wire AC Cable NO PS10-30GI50-3WA PS15-30GI50-3WA NC PS10-30GI50-3WF PS15-30GI50-3WF 87 88 Nominal sensing distance 10 mm 15 mm Operating distance 8.1 mm 12.15 mm Mounting flush non-flush Hysteresis 5% 5% < 0.01 mm < 0.01 mm 30 x 30 mm 45 x 45 mm 20 to 250 Vac 20 to 250 Vac 50 or 60 Hz 50 or 60 Hz 500 mA 500 mA Drawing Repeatability Standard target Operating voltage range Operating frenquency Max. switching current Inrush current( t<20ms/ f< 1Hz) 4A 4A Output voltage drop <2V <2V Max. switching frequency 10 Hz 10 Hz Output indicator Operating temperature range backside led - 25 oC to + 70 backside led oC - 25 oC to + 70 oC Protection class IP 67 IP 67 Weight 205g 205g 2 m PVC cable,2 x 20 AWG 2 m PVC cable,2 x 20 AWG 6m PVC, 2 m PU cable 6m PVC, 2 m PU cable 50, 70 mm(option) 50, 70 mm(option) GX, GT, GP GX, GT, GP Connection Cable options Tube length Housing options Electrical connections W3A BN BK BU NO W3F BN BK BU Code GM + GI 20 - 250 Vac - + 20 - 250 Vac Housing nickel plated brass and lateral led nickel plated brass and backside led Cable Colors GX stainless steel and backside led BN - brown / BU - blue GT PTFE plated brass and backside led GN / YE - green / yellow GP thermoplastic polyester with fiberglass and backside led 50 50 mm tube length (standard) 70 70 mm tube length (option) - NO Dimensions Ø 87 1.26 88 Inductive Line
© Copyright 2025 Paperzz