ELEKTRAL A.S. You need 15 minutes for assembling!... ASSEMBLING & MOUNTING ThruScan Get User’s Manual PLS. Download from our web-site: www.elektral.com.tr 1 You receive 2 boxes for each metal detector: • Main Control & Display Unit • Side Panels (Left&Right) ELEKTRAL A.S. You need 15 minutes for assembling!... ASSEMBLING & MOUNTING ThruScan Get User’s Manual PLS. Download from our web-site: www.elektral.com.tr When you open the boxes: • Main Control & Display Unit • Back Fixing Unit • Left Side Panel • Right Side Panel 2 ELEKTRAL A.S. You need 15 minutes for assembling!... ASSEMBLING & MOUNTING ThruScan Get User’s Manual PLS. Download from our web-site: www.elektral.com.tr 3 Assembling Back Fixing Unit 4 Other side ELEKTRAL A.S. You need 15 minutes for assembling!... ASSEMBLING & MOUNTING ThruScan Get User’s Manual PLS. Download from our web-site: www.elektral.com.tr Screw up the rear cover of the Main Control & Display Unit. 5 ELEKTRAL A.S. You need 15 minutes for assembling!... ASSEMBLING & MOUNTING ThruScan Get User’s Manual PLS. Download from our web-site: www.elektral.com.tr 7 For the sockets: ThruScan is designed to prevent false connector/socket connection. Left Panel – female D-Sub 25 Mains Socket - SRC- D-Sub 9 Right Panel – male D-Sub 25 6 ELEKTRAL A.S. You need 15 minutes for assembling!... ASSEMBLING & MOUNTING ThruScan Get User’s Manual PLS. Download from our web-site: www.elektral.com.tr Screw down the Main Control & Display Unit. Fix strongly to the side panels. 8 9 ELEKTRAL A.S. You need 15 minutes for assembling!... ASSEMBLING & MOUNTING ThruScan Get User’s Manual PLS. Download from our web-site: www.elektral.com.tr 11 10 Lift up your ThruScan Fasten the black blind taps ELEKTRAL A.S. You need 15 minutes for assembling!... ASSEMBLING & MOUNTING ThruScan Get User’s Manual PLS. Download from our web-site: www.elektral.com.tr 12 Plug in the connectors. ELEKTRAL A.S. You need 15 minutes for assembling!... ASSEMBLING & MOUNTING ThruScan Get User’s Manual PLS. Download from our web-site: www.elektral.com.tr Right Side Panel Connector Mains Connector (from left side panel) 13 Left Side Panel Connectors 14 Impossible to make mistake… ELEKTRAL A.S. You need 15 minutes for assembling!... ASSEMBLING & MOUNTING ThruScan Get User’s Manual PLS. Download from our web-site: www.elektral.com.tr 15 Close the rear cover of Main Display & Control Unit. ELEKTRAL A.S. You need 15 minutes for assembling!... ASSEMBLING & MOUNTING ThruScan Get User’s Manual PLS. Download from our web-site: www.elektral.com.tr Adjust the distance between side panels to 76 cms. 16 ELEKTRAL A.S. You need 15 minutes for assembling!... ASSEMBLING & MOUNTING ThruScan Get User’s Manual PLS. Download from our web-site: www.elektral.com.tr 17 18 Mark the positions of side panel holders. ELEKTRAL A.S. You need 15 minutes for assembling!... ASSEMBLING & MOUNTING ThruScan Get User’s Manual PLS. Download from our web-site: www.elektral.com.tr 20 19 Drill & Fix the side panel holders to the ground – stable conditions. 21 22 ELEKTRAL A.S. You need 15 minutes for assembling!... ASSEMBLING & MOUNTING ThruScan Get User’s Manual PLS. Download from our web-site: www.elektral.com.tr 23 Put your ThruScan into the side panel holders inside and screw the bolts. 25 24 ELEKTRAL A.S. CONTROL PANEL OF ThruScan Metal Detectors OFF BUTTON ON BUTTON BATTERY INDICATOR LCD DISPLAY 4*20 RUN BUTTON SEL UP DOWN TOUCH PADS ALARM LOCATOR PACING LIGHT INDICATOR LED VU DISPLAY ELEKTRAL A.S. MULTI POINT INDICATOR LIGHTS ENTRANCE- Traffic Lights Led illuminated Warning Displays on Zones ELEKTRAL A.S. RELAY CONTACT OUTPUTS RELAY CONTACT OUTPUTS Provides to control CCTV Cameras, Turnstiles, Gates…etc. SYNC & REMOTE CONTROL OUTPUTS For tandem operation or SRC- Scada Remote Control ELEKTRAL A.S. PROGRAMMING & SETUP Normal Operating Screen (When you swich on – the screen) To enter the program menu Press If the correct password is entered display will change to: If the password is incorrect: IN 01978 OUT 00027 SECURITY LEVEL 03 ENTER PASSWORD [0---] SECURITY LEVEL LEVEL 02 SECURITY LEVEL PASSWORD ERROR ELEKTRAL A.S. SECURITY LEVEL & SENSITIVITY LEVEL ADJUSTMENTS ThruScan s9 has 10 seperate SECURITY LEVELS SECURITY LEVEL ThruScan sX has 20 seperate SECURITY LEVELS LEVEL 02 It is possible to adjust a total of 246 sensitivity levels from security level 000 (highest sensitivity) to 245 (lowest sensitivity) SECURITY LEVEL ThruScan s9 LEVEL [02]=20 SECURITY LEVEL SENSITIVITY ADJUSTMENT Security Level (NC) NILECJ – Level 2 (factory fixed) Security Level 1 010 Security Level 2 Security Level 3 Security Level 4 Security Level 5 Security Level 6 Security Level 7 Security Level 8 Security Level 9 020 030 050 100 140 180 220 230 ELEKTRAL A.S. SECURITY LEVEL & SENSITIVITY LEVEL ADJUSTMENTS ThruScan sX SECURITY LEVEL SENSITIVITY ADJUSTMENT Security Level (NC) NILECJ – Level 2 (factory fixed) Security Level 1 010 Security Security Security Security Security Security Security Security Security Security Level Level Level Level Level Level Level Level Level Level 2 3 4 5 6 7 8 9 10 11 020 030 040 050 060 070 080 090 100 110 Security Security Security Security Security Security Security Security Level Level Level Level Level Level Level Level 12 13 14 15 16 17 18 AD 120 140 160 180 200 220 240 030 – Auto Designation/AD SECURITY LEVEL LEVEL 02 SECURITY LEVEL LEVEL [02]=20 SECURITY LEVEL LEVEL [15]=180 ELEKTRAL A.S. SECURITY LEVEL You can make fine tunning here: 185 LEVEL [15]=180 Between 000(highest sebsitivity) – 245(lowest sensitivity) IN 01978 OUT 00027 ENTER PASSWORD [0---] SECURITY LEVEL 03 SECURITY LEVEL SECURITY LEVEL LEVEL [02] LEVEL 02 SECURITY LEVEL LEVEL [15] ELEKTRAL A.S. SECURITY LEVEL SECURITY LEVEL LEVEL [15]=180 LEVEL [15]=181 SECURITY LEVEL LEVEL [15]=185 Normal Operating Mode Other Menus ELEKTRAL A.S. SECURITY LEVEL & SENSITIVITY LEVEL, ZONE ADJUSTMENTS for ThruScan sX The sensitivity levels of zones can be adjusted separately. The sensitivity level of zone 2 in which there would more likely be keys, cell phones, belts etc. can be decreased while the other zones’ can be increased. IN 01978 OUT 00027 *5 LEVEL [02]=20 SECURITY LEVEL 03 SECURITY LEVEL INDIVIDUAL ZONE SENS LEVEL [02] SECURITY LEVEL INDIVIDUAL ZONE SENS LEVEL [02] ZONE=[01] SECURITY LEVEL SECURITY LEVEL INDIVIDUAL ZONE SENS LEVEL 02 ZONE=2 ZONE=3 ZONE [01]=20 *1 Other Menus Normal Operating Mode ELEKTRAL A.S. AUTO DESIGNATION AND AUTOMATIC SENSITIVITY ASSIGN for ThruScan sX This menu is to help the user to decide and to assign the required sensitivity level very rapidly. IN 01978 OUT 00027 *5 SECURITY LEVEL 03 WHEN TRAFFIC LED IS GREEN, ENTER METAL OBJECT THEN PRESS SEL 3/2 WHEN TRAFFIC LED IS GREEN, ENTER METAL OBJECT THEN PRESS SEL 3/3 SECURITY LEVEL *2 AUTO DESIGNATE MODE LEVEL [02]=20 USED FOR AUTO DESIGNATE OF SECURITY LEVEL TO CONTINUE PRESS SEL WHEN TRAFFIC LED IS GREEN, ENTER METAL OBJECT THEN PRESS SEL 3/1 DESIGNATE-DETECTMOD ALL ZONES 00 ZONE 01 01 [00] 00 ELEKTRAL A.S. AUTO DESIGNATION MODE - continue DESIGNATE-DETECTMOD ALL ZONES 00 ZONE 01 01 AUTO DESIGNATE MODE TO DESIGNATE PRESS SEL ZONE [01] [53] SELECT THE ZONE AUTO DESIGNATE MODE TO DESIGNATE PRESS SEL ZONE [01]=53 AUTO DESIGNATE MODE TO DESIGNATE PRESS SEL LEVEL [AD]=53 AUTO DESIGNATE MODE IN 01978 OUT 00027 SECURITY LEVEL 03 ELEKTRAL A.S. ALARM VOLUME ADJUSTMENT ThruScan s9-sX has 10 separate alarm volume levels, 1 quietest – 10 loudest – 00 Mute If you want different tones, pls mention with your order. It has 10 different tones in the menu. IN 01978 OUT 00027 SECURITY LEVEL 03 *5 SECURITY LEVEL *3 ALARM VOLUME 0<=>10 LEVEL [02]=20 ALARM VOLUME 0<=>10 VOLUME=10 ALARM VOLUME 0<=>10 VOLUME=05 ELEKTRAL A.S. ALARM COUNTER IN 01978 OUT 00027 SECURITY LEVEL 03 *5 SECURITY LEVEL ALARM COUNTER 00012 LEVEL [02]=20 NORMAL OPERATING MODE MENU ALARM COUNTER 00000 *4 ALARM COUNTER 00012 RESET Y <=> N Y ALARM COUNTER 00012 RESET Y <=> N N ELEKTRAL A.S. IN – OUT COUNTER (TRAFFIC COUNT) IN 01978 OUT 00027 SECURITY LEVEL 03 *5 SECURITY LEVEL *5 IN>-COUNTER-<OUT 99999………………….…01977 LEVEL [02]=20 NORMAL OPERATING MODE IN>-COUNTER-<OUT 99999………………….…01977 ACTIVE =00 MENU 00 – Do not reset 01 – Reset In Count 02 – Reset Out Count 03 – Reset Both Counters ELEKTRAL A.S. FACTORY SETTINGS ThruScan s9-sX can be returned to factory setting by this menu. IN 01978 OUT 00027 SECURITY LEVEL 03 *5 SECURITY LEVEL *6 FACTORY SETTINGS Y<==>N LEVEL [02]=20 NORMAL OPERATING MODE FACTORY SETTINGS Y<==>N ACTIVE =N Y – FACTORY RESET N – DO NOT RESET MENU ELEKTRAL A.S. LANGUAGE SELECTION ThruScan s9-sX can be operated in 4 languages- EN-DE-SPA-TR IN 01978 OUT 00027 SECURITY LEVEL 03 *5 SECURITY LEVEL *7 LANGUAGE ENGLISH LEVEL [02]=20 NORMAL OPERATING MODE LANGUAGE ENGLISH <===================> MENU ENGLISH DEUTSCH TURKCE ESPANOL ELEKTRAL A.S. COUNTER VISIBILITY ThruScan s9-sx’ Normal Operating Mode-Menu Displaycan be inhibited. IN 01978 OUT 00027 SECURITY LEVEL 03 *5 SECURITY LEVEL *8 COUNTER VISIBILITY Y<==>N LEVEL [02]=20 NORMAL OPERATING MODE COUNTER VISIBILITY Y<==>N ACTIVE =Y MENU N – DISPLAY OFF Y – DISPLAY ON IN ***** OUT ***** SECURITY LEVEL 03 ELEKTRAL A.S. ENVIRONMENT NOISE LEVEL This menu is prepared to measure the electromagnetic noise level in the environment in which the ThruScan was placed and help the user with the sensitivity level assignment. IN 01978 OUT 00027 SECURITY LEVEL 03 NORMAL OPERATING MODE MENU *5 SECURITY LEVEL *9 ENVIRONMENTAL NOISE LEVEL LEVEL [02]=20 ENVIRONMENTAL NOISE LEVEL NOISE = 003 ELEKTRAL A.S. NEW PASSWORD You can change your 4 digit pin-code as follows: Let’s make password 1978 IN 01978 OUT 00027 SECURITY LEVEL 03 NEW PASSWORD [1978 ] *5 SECURITY LEVEL * 10 NEW PASSWORD [ ] LEVEL [02]=20 NEW PASSWORD [1*** ] 1 2 3 … … …. 8 9 NORMAL OPERATING MODE MENU NEW PASSWORD [0*** ] 1 2 3 … … …. 8 9
© Copyright 2026 Paperzz