Supplementary Material Energy transfer from pyridine molecules towards Europium cations contained in sub 5-nm Eu2O3 nanoparticles: can a particle be an efficient multiple donoracceptor system? I. Schematic representation (Fig. 1) of each step of the elaboration process of coreshell particles grafted with pyridine molecules (antenna). Figure 1. Schematic presentation of the synthesis process II. High-resolution transmission electron microscopy (HRTEM) images performed on core/shell particles a) b) Figure 2. a) High resolution TEM image of Eu2O3 core nanoparticles showed the crystallised phase. b) Fast Fourier Transform (FFT) of some crystallised oxide and their interreticular distances. The interreticular distances and the angles observed fit the bcc lattice parameters with a = 10.86 ± 0.01 Å. a) Number of cores (arb. units) b) TEM observations DLS measurements 1 10 Hydrodynamic diameter of the cores (nm) Figure 3. a) High resolution TEM image of Eu2O3 nanoparticles coated by polysiloxane. Polysiloxane shell is not visible on the images and reduces the visualization of the fringes related to the crystallised oxide. b) Comparison between the size distributions of cores by TEM analysis and by DLS measurements. III. Characteristic of synthesis steps: table 1, the amount of pyridine molecules (the donors) per particle is varied; table 2 the polysiloxane thickness of the particle is varied. Number of antenna grafted on the core/shell particles 2,6-Pyridinedicarboxylic acid Number of Antenna per europium atom Europium amount (µmoles) APTES (µL) TEOS (µL) DEG solution (µL) Antenna (µg) EDC (µg) NHS (µg) 1/250 1/100 1/20 1/10 0.2 0.4 0.6 0.8 1.2 60 16.8 10.8 40.8 40.0 92.0 55.2 60 16.8 10.8 40.8 100.0 230.0 138.1 60 16.8 10.8 40.8 500.0 1150.2 690.5 60 16.8 10.8 40.8 1000.0 2300.4 1381.1 60 16.8 10.8 40.8 2000.0 4600.8 2762.2 60 16.8 10.8 40.8 4000.0 9201.6 5524.3 60 16.8 10.8 40.8 6000.0 13802.4 8286.5 60 16.8 10.8 40.8 8000.0 18403.2 11048.6 60 16.8 10.8 40.8 12000.0 27604.8 16572.9 Table 1. Different amount of pyridine molecules for the same thickness of polysiloxane Number of silica shell coating the oxide core with the amount of antenna graft on the surface 2,6-Pyridinedicarboxylic acid Number of Silica per europium atom Europium amount (µmoles) APTES (µL) TEOS (µL) DEG solution (µL) Antenna (mg) EDC (mg) NHS (mg) 1 Si 2 Si 3 Si 4 Si 600 84 54 204 0.40 0.92 0.6 600 168 108 408 0.40 0.92 0.6 600 252 162 612 0.40 0.92 0.6 600 336 216 816 0.40 0.92 0.6 Table 2. Different amount of APTES/TEOS precursors for the number of Antenna ๐ท ๐ด ๐ ๐ท ๐ท = ๐ ๐๐ฆ๐๐๐๐๐๐/๐๐๐๐ก๐๐๐๐๐ โ ๐๐๐ฆ๐๐๐๐๐๐/๐๐๐๐ก๐๐๐๐๐ = ๐๐ธ๐ข/๐๐๐๐ก๐๐๐๐๐ ๐ด = 670 ๐ด. ๐ธ๐ข๐๐๐๐๐ข๐/๐๐๐๐ก๐๐๐๐๐ IV. Calculation of the silica thickness by ICP-AES analysis and comparison with the silica thickness measured by DLS analysis After ultrafiltration of the colloidal samples (3 kDa PES membrane), an ICP โ AES was performed in order to obtain the number of Silicon and Europium atoms amount for each sample. It is then possible to calculate the yield of oxide formation rEu and the polysiloxane coating rSi. The amount of Europium was found the same even after purification. Thus rEu was determined equal to 1. The volume ratio of the silica and Europium in each sample was calculated in function of r Si and rEu: ๐๐๐๐2 ๐๐๐ ๐๐๐๐2 โ๐๐๐๐2 = ๐ ๐๐ธ๐ข01.5 ๐๐ธ๐ข ๐๐ธ๐ข๐1.5 โ๐๐ธ๐ข๐1.5 with n the ratio of SiO2 and EuO1.5 introduced, ๐๐๐๐2 (60.1 g.mol-1) and ๐๐ธ๐ข๐1.5 (175.9 g.mol-1) the molecular mass of SiO2 and EuO1.5 respectively, ๐๐๐๐2 (2) and ๐๐ธ๐ข๐1.5 (7.5) the density of SiO2 and EuO1.5 respectively. Direct estimation of core size by TEM micrographs analysis (Rcore = 1.8 nm) and the knowledge of the polysiloxane to the Europium volume ratio, allows the calculation of polysiloxane thickness e of nanoparticles: ๐๐๐๐2 ๐๐ธ๐ข01.5 =๐ (๐ +๐)3 โ(๐ )3 (๐ )3 3 ๏ณ๐ = โ ๐๐๐๐ 2 ๐๐๐ ๐ ๐๐๐2 (๐ ๐๐๐๐ )3 +(๐ ๐๐๐๐ )3 ๐๐ธ๐ข ๐ ๐2๐ 2 3 ๐ธ๐ข2 ๐3 โ ๐ ๐๐๐๐ n rSi ๐๐๐๐2 ๐๐ธ๐ข01.5 Calculated Thickness (nm) Measured Thickness (nm) 1 0.41 0.52 0.27 0.28 2 0.36 0.92 0.43 0.44 3 0.35 1.34 0.59 0.6 4 0.33 1.69 0.70 0.71 Table SI: comparison between calculated thickness and measured thickness by DLS analysis 1.0 ThicknessSi shell (nm) Calculated from the yield of Si coating Measured from DLS 0.8 0.6 0.4 0.2 0.0 1 2 3 4 Number of polysiloxane addition The thickness of polysiloxane shell determined by ICP analysis or measured by DLS is almost the same. V. Luminescence spectra of, on one hand the core alone and, on the other hand, the four core/shells elaborated. 140 Eu2O3 Iemi @ ๏ฌexci = 395 nm (arb. units) 120 Eu(OH) Eu2O3@1Si 100 Eu2O3@2Si Eu2O3@3Si 80 Eu2O3@4Si 60 40 20 0 550 600 650 700 750 Wavelength (nm) Figure 4. Comparison of Europiumโs emission spectra for an excitation at 395 nm between on one hand the particles with the different thicknesses and the particles without polysiloxane shell, and the other hand, the hydroxide europium particles. 1- The comparison of the 5D0 ๏ฎ 7F1 magnetic and of the 5D0 ๏ฎ 7F2 forced electric dipole transition related to the spectrum of the core demonstrates that this latter effectively possesses the bcc oxide phase. Indeed, the hydroxide phase is characterized by an electric transition largely smaller than that of the magnetic one. 2- By polysiloxane coating the electric transition band increases. This is in agreement with the modification of the Eu cations at the vicinity of surface coating. 3- The increase in the electric transition is the same regardless of the quantity of polysiloxane deposited on the core. This indicates that, from the first shell growth, the surface of the core is entirely coated. This constitutes a major agreement for a uniform and homogeneous coating. VI. Emission spectra for an excitation at 340 nm of: free pyridine molecules, pyridine grafted on Eu2O3 + 0.44 nm SiOx, pyridine grafted on Eu2O3 + 0.28 nm SiOx. For each case, the pyridine concentration was 78 molecules per µm3 and the Europium concentration was 29 particles per µm3. There is an expected emission reduction of the pyridine luminescence due to the transfer. Pyridine alone [email protected] nm SiOx@pyridine Iem (arb.units) [email protected] nm SiOx@pyridine 375 400 425 450 475 Wavelength (nm) 500 525 Figure 5. Comparison of the emission spectra for an excitation at 340 nm between the free pyridine molecules, the pyridine grafted on the europium oxide core with 0.44 nm SiOx, and with 0.28 nm - SiOx.
© Copyright 2026 Paperzz