Q-PLUS EVO The worldÕs most powerful tattoo removal laser with three PRIMARY wavelengths Q-Switched Nd:YAG & Ruby laser 532nm, 1064nm & 694nm Quanta System Q1 DNA DNA Laser Technology Q-PLUS EVO No other laser device removes more tattoo colours than the Q-PLUS EVO, delivering three powerful PRIMARY laser wavelengths to tackle all treatable inks. The Q-PLUS EVO can also be used to effectively treat a broad range of epidermal and dermal pigmented lesions. Unique and unprecedented laser technology combines three PRIMARY Q-switched Nd:YAG (1064/532nm) & Ruby (694nm) laser wavelengths (not using inefficent Dye handpieces) to ensure quick, comfortable treatment while removing all treatable tattoo pigments. Industry renowned, the Q-PLUS EVO can remove tattoos quickly and effectively thanks to the combination of super high peak powers, large spot sizes and an industry-leading repetition rate. Proven, clinical results for all treatable tattoo colours, including greens, blues & reds Unique Tri-wavelength laser with one of the fastest repetition rates on the market, variable up to 10Hz Patented OPTIBEAM® II technology delivers homogeneous energy distribution resulting in less skin trauma Award-winning ResurFACE® Pro Er:YAG fractional handpiece upgrade, available for ablative treatments with minimal downtime This is definitely the laser that you need for removal of all treatable tattoo colours. There is more power than you’ll ever actually require, and my clients who’ve had the misfortune to previously go to an amateur tattoo remover, always comment on the superior results they see after each treatment. I would always thoroughly recommend the Q-PLUS C.˝ Amy Pearson, Clinical Manager, Blink Laser Tattoo Removal 23 Unrivalled Power In active Q-switched systems, the very short individual pulse (6ns from the Nd:YAG, 30ns from the Ruby) delivers exceptionally high peak powers (hundreds of megawatts) to the target chromophore, resulting in an efficient photo-acoustic effect and no thermal interaction with the skin tissue. As a result, the unwanted pigment in the skin is fragmented into small particles which are then expelled through the body’s normal phagocytosis process. The Q-PLUS SERIES consists of two models: the Q-PLUS A & Q-PLUS C EVO. These are both unique systems manufactured to meet the needs and requirements of the practitioner: both delivering superior results for tattoo removal. For those looking to introduce a system that removes the majority of tattoos with excellent clinical efficacy - the Q-PLUS A is perfectly suited. Eliminates the toughest inks :- green & blue For effective removal of all treatable tattoo pigment, the Q-PLUS C EVO is the perfect choice. Its proven track-record of results cements its place as the premier system available, combining three high-powered PRIMARY lasers wavelengths in one, comprehensive system. Q-PLUS A This highly powerful Active Q-Switched model provides 1064nm and 532nm wavelengths; ideal for black, red and orange tattoos alongside dermal and epidermal pigmented lesions. Various Spot Sizes With the option to add ResurFACE® Pro Er:YAG fractional laser technology and to upgrade to a Q-PLUS C EVO at a later date, the Q-PLUS A model offers versatility as a flexible option for those looking to enter the tattoo removal market. Q-PLUS C The most advanced system in the Q-PLUS Series, the Q-PLUS C EVO incorporates both a Q-switched Nd:YAG Laser System operating at 1064/532nm and a Q-Switched Ruby Laser System operating at 694nm. The THREE output wavelengths give exceptional results on all treatable tattoo colours, alongside pigmented lesions. New ‘Gorilla Glass®’ 10’ inch touchscreen OPTIBEAM® II A unique characteristic of the Q-PLUS EVO is its utilisation of OPTIBEAM II® technology handpieces. The square spot profile delivers safer and more efficient treatments compared to round spot sizes due to its ability to deliver the laser energy homogeneously, helping you treat an entire area with no overlap. Voted Treatment of the Year - the award-winning ResurFACE® Pro fractional laser (2940nm) is the ultimate upgrade available on the laser market. The OPTIBEAM II® handpiece ensures a perfect FLAT TOP beam profile thanks to its advanced optical technology, which distributes the power of the laser homogeneously across the output beam profile. This results in less skin trauma and decreased incidence of side effects. Easier and more precise coverage of the entire treatment area is possible, which because it avoids unwanted overlapping which can result in up to 20% reduction in treatment downtime compared to traditional round spot shapes. By offering Er: YAG fractional resurfacing technology, our customers have seen dramatic results, helping their clients overcome the following aesthetic concerns: -- Lines and wrinkles -- Pigmentation -- Scarring -- Acne scarring -- Skin laxity -- Stretch Marks -- Age spots -- Sun damage -- Uneven texture -- Congestion -- Milia -- Freckles ® Conventional Laser OPTIBEAM® II Laser Q-PLUS EVO Results Tattoo Removal Before Tattoo Removal After After ResurFACE® Pro Anti-Ageing Pigmentation Before Before Tattoo Removal After Before After Before After ResurFACE® Pro Stretch Mark Before To learn more, or to arrange a demonstration, call Lynton on 01477 536 977 or visit lynton.co.uk After Call Lynton today on 01477 536 977 or visit lynton.co.uk System Specifications Q-PLUS A Laser Type Nd:YAG Nd:YAG Wavelength1064nm 532nm Pulse Width (ns)66 Repetition Rate (Hz) Up to 10 Up to 10 Spot Size (mm) 3x3/4x4/5x5 square 3x3/4x4/5x5 square Fluence Range (J/cm2) Up to 11 Up to 5.5 Electrical Info 220-230 V AC; 16 A; 50-60 Hz Dimensions & Weight 480 (W) x900 (L) x 930(H) mm - 80kg Manufacturer Quanta, Italy System Specifications Q-PLUS C EVO Laser Type Nd: YAG Nd: YAG Ruby Wavelength1064nm532nm 694nm Pulse Width (ns)6630 Repetition Rate (Hz)Up to 10Up to 103 Spot Size (mm) 3x3/4x4/5x5 square 3x3/4x4/5x5 square 3x3/4x4/5x5 square Fluence Range (J/cm2) Up to 16.5 Up to 6.7 Up to 13.3 Electrical Info 220-230 V AC; 16 A; 50-60 Hz Dimensions & Weight 480 (W) x900 (L) x 930(H) mm - 80kg Manufacturer Quanta, Italy System Specifications Fractional Handpiece - ResurFACE® Laser Type Wavelength Repetition rate Treatment zone Fractional output Energy per microspot Er: YAG 2940 nm Up to 1.5 Hz with Pulse Stacking 10 mm diameter 40 microspots per cm2 Up to 20 mJ Lynton Lasers Ltd Lynton House, Manor Lane, Holmes Chapel, Cheshire, CW4 8AF Tel: +44 (0)1477 536 977 Fax: +44 (0)1477 536 978 [email protected] Quanta System Q1 DNA DNA Laser Technology 0123 APRIL 17 - SK
© Copyright 2026 Paperzz